Product Data. 58PHA/PHX PERFORMANCE BOOST WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 135,000 Btuh

Similar documents
Product Data. S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

Product Data STANDARD FEATURES

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

Product Data. 58STA/STX 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh THE CARRIER 58STA/STX GAS FURNACE

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. 58CVA/CVX INFINITY 80 VARIABLE SPEED 4---WAY MULTIPOISE GAS FURNACE Input Capacities: 70,000 thru 155,000 Btuh Series 160

310AAV/310JAV Sizes 045 thru 155 Series A

ama 311AAV/311JAV Sizes 045 thru 155 Series A 4-Way Multipoise Induced Combustion Gas Furnace Form No. PDS 311A.45.3

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. 58DLA/DLX COMFORT 80 DELUXE 4-WAY MULTIPOISE INDUCED-COMBUSION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Product Data. 58DLA/DLX WeatherMaker 8000 Deluxe 4-Way Multipoise Induced-Combustion Gas Furnace. Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58CTA/CTX PERFORMANCE 80 TWO-STAGE 4-WAY MULTIPOISE INDUCED-COMBUSTION FURNACE Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

395CAV Sizes 045 thru 155 Series H and J

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. Comfort Heatt technology, the ultimate in heating comfort...

352AAV 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE. Sizes 060 thru 120. Catalog No. PDS 352A.60.1

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Installation, Start-up, Operating, and Service and Maintenance Instructions -Series 120

Product Data. 352AAV 4-Way Multipoise Two-Stage Condensing Gas Furnace. Sizes 060 thru 120

Installation, Start---up, Operating and Service and Maintenance Instructions Series 120/C

Installation, Start-up, Operating, and Service and Maintenance Instructions Series 120/C

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Installation, Start---up, Operating and Service and Maintenance Instructions Series 120/C

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Product Data. IdealComfortt technology, the ultimate in heating comfort...

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Installation, Start-up, Operating, and Service and Maintenance Instructions -Series A

Installation, Start-up, Operating, and Service and Maintenance Instructions -Series 100

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

PLUS 95st MODEL 355CAV DELUXE 4 -WAY MULTIPOISE VARIABLE -SPEED MULTI -STAGE CONDENSING GAS FURNACE Series 100 Input Rates: 60,000 thru 120,000 Btuh

Product Data. 58MCB 4-WAY MULTIPOISE FIXED-CAPACITY CONDENSING GAS FURNACE Input Rates: 40,000 thru 138,000 Btuh

Single-Stage Deluxe Induced-Combustion 4-Way Multipoise Furnace

Product Data. Infinity 96 Model 58MVB Deluxe 4-Way Multipoise Variable-Speed Condensing Gas Furnace. Series 100 Input Rates: 40,000 thru 120,000 Btuh

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 59TN6A InfinityR Two---Stage, Variable Speed Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

Product Data 987MA EVOLUTIONR MODULATING 4 -WAY MULTIPOSE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

CONDENSING GAS FURNACE

Product Data. 59MN7A Infinityr Modulating Way Multipoise Condensing Gas Furnace Series 100

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

Product Data. 59SC2A Comfort Series Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. Perfect Heatt technology, the ultimate in heating comfort...

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

Product Data. 58MTA Highly-Efficient 4-Way Multipoise Two-Stage Direct-Vent Deluxe Condensing Gas Furnace. Input Capacities: 60,000 thru 120,000 Btuh

311AAV Series 100. Installation, Start-up, and Operating Instructions SINGLE-STAGE INDUCED COMBUSTION DELUXE 4-WAY MULTIPOISE FURNACE

Product Data. 58VLR LOW --- BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES VLR FEATURES/BENEFITS

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT DELUXE CONDENSING GAS FURNACE. Sizes 040 thru 140. Form No. PDS 350M.40.

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

8+* Bulletin No November 1997

FG7T (C and L Series)

Wt. Lbs Model Number (BTUH) Hz

Product Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

MERIT SERIES Downflow

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

355MAV Sizes 040 thru 120 Series E

TECHNICAL SPECIFICATIONS

Product Data PERFECT HEATT TECHNOLOGY, THE ULTIMATE IN HEATING COMFORT...

Product Data 369AAN FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40.

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

ELITE SERIES Downflow - High Efficiency Blower Motor

Installation, Start-Up, and Operating Instructions For Sizes , Series 180

Product Data A {Jurisdictions where warranty benefits cannot be conditioned on registration

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

Product Data PG95XAT CONDENSING GAS FURNACE SERIES B STANDARD FEATURES

RG7D 1-Stage Heat Series

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Installation, Start-Up, and Operating Instructions For Sizes , Series 100

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Product Data. 925TA PREFERREDt SERIES TWO -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES B

Transcription:

/PH PERFORMANCE BOOST 80 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 135,000 Btuh Product Data A04040 THE CARRIER Comfortt 80 GAS FURNACE The /PH 4 -way Multipoise Gas Furnaces offer deluxe features not found in other single-stage 80% gas furnaces. The ECM motor and Carrier s control logic combine to provide a SEER BOOST to your condensing unit of up to 1.5 points as compared to coil only ratings. Carrier s QuieTecht noise reduction system makes the Comfortt 80 an incredibly quiet induced -draft gas furnace. The exclusive Carrier Media Cabinet provides an economic way to add high performance air filtration to homes. The gas furnace control system provides a dehumidification mode, a motor speed selection for continuous fan operation selectable at the thermostat, and fault code storage in the event of power Comfort outages. Applications are easy with 4 -way multipoise design, through -the-furnace downflow venting, 13 different venting options, and a door designed for easy service access. An inner blower door is provided for tighter sealing in sensitive applications. The /PH furnaces are approved for use with natural or propane gas, and the 58PH is approved for use in Low NOx Air Quality Management Districts. STANDARD FEATURES S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control S ComfortFant adjustable constant fan speed from the thermostat S High -Efficiency Media Filtration Cabinet included S Microprocessor based control center S LED diagnostics and self test feature S Stores fault codes during power outages S Adjustable heating air temperature rise S Adjustable cooling airflow S Dehumidification selection for summer -time cooling S 4 -way Multipoise furnace, 13 vent applications S Compact design - only 33-1/3 in. (847 mm) tall S Power Heat SiNt Igniter S Draft safeguard switch to ensure proper furnace venting S Insulated blower compartment S Inner door for tighter sealing S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit S Residential installations eligible for consumer financing through the Retail Credit Program LIMITED WARRANTY S 20 -year warranty on Super St heat exchanger S 5 -year parts warranty on all other components 1

FURNACE COMPONENTS INDUCER MOTOR ASSEMBLY PRESSURE SWITCH FLUE COLLECTOR BO GAS VALVE MANUAL RESET LIMIT SWITCHES VENT ELBOW MAIN LIMIT SWITCH (BEHIND GAS VALVE) DRAFT SAFEGUARD SWITCH FLAME SENSOR GAS MANIFOLD GAS BURNER HOT SURFACE IGNITER CONTROL RATING PLATE NOT SHOWN (LOCATED ON BLOWER DOOR) BLOWER DOOR SAFETY SWITCH BLOWER AND MOTOR CAPACITOR/POWER CHOKE (WHERE USED) A02259 NOTE: The /PH Furnaces are factory shipped for use with natural gas. These furnaces can be field -converted for propane gas with a factory -authorized and listed accessory conversion kit. 58DLA/DL A02169 HEAT ECHANGER A02169 CONTROL BOARD A08063 INDUCER BLOWER A02170 MODEL NUMBER NOMENCLATURE 045 F 100 08 Nominal Cooling Size (Airflow at.5 e.s.p.) 400 CFM per 12,000 Btuh) 08 --- 800 CFM 12 --- 1200 CFM 20---2000 CFM Deluxe 4---Way Multipoise 58PH Low NOx Version Series Number Media Filter Cabinet included Input Rates 045 --- 44,000 Btuh 070 --- 66,000 Btuh 090 --- 88,000 Btuh 110 --- 110,000 Btuh 135 --- 132,000 Btuh 2

ON OFF Cell Energized Tur to prevent e! Electronic High Efficiency Air Filtration System Input Power JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ly CARRIER ACCESSORIES 58DLA/DL A97432 CONTROLS: THERMOSTATS AND ZONING Available in programmable and non-programmable models, Carrier thermostats maintain a constant, comfortable temperature level in the home. For the ultimate in home comfort, Carrier s 2, 4, and 8-zone systems allow temperature control of individual zones of the home. This is accomplished through a series of electronic dampers and remote room sensors. The 4-zone system is shown. WARNING Electric Shock Hazard n OFF remote powerbefore removing any panel More thanone powersupply may be present Thisequipmentshould be inpected frequentlyandcollecteddirt removedregular xcessive accumulation thatmayresult in flashoverorfiredamage C04008 MECHANICAL OR ELECTRONIC AIR CLEANER Cleans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner. Electronic air cleaner is shown. A01484 MODEL HUMCCLFP HUMIDIFIER By adding moisture to winter-dry air, a Carrier humidifier can often improve comfort and keep furniture, rugs, and draperies in better condition. Moisturizing household air also helps to retain normal body heat and provides comfort at lowertemperatures. A08152 ACCESSORIES ELECTRONIC AIR CLEANER Model EACB (EAC) AIR PURIFIER Models GAPAACC1625, GAPAACC2025 MECHANICAL AIR CLEANER Models EZCAB, FILCAB HUMIDIFIER Model HUM HEAT RECOVERY Model HRV VENTILATOR ENERGY RECOVERY Model ERV VENTILATOR UV LIGHTS Model UVL For use with 1 ---speed Air Conditioner --- deg. F/C, Auto Changeover --- TP ---NAC, TC ---NAC For use with 1 ---speed Air Conditioner --- deg. F/C, Auto Changeover --- TP ---NHP ---TC ---NHP* THERMOSTAT --- For use with 2 ---speed Air Conditioner --- deg. F/C, Auto Changeover --- TP ---NRH* NON --- PROGRAMMABLE For use with multi---use / stage configurations --- deg. F/C, Auto Changeover/Temperature and Humidity Control --- TP ---PRH{ For use with 1 ---speed Air Conditioner --- deg. F/C, Auto Changeover, 7 ---Day Programmable --- TP --- PAC For use with 1 ---speed Air Conditioner --- deg. F/C, Auto Changeover, 7 ---Day Programmable --- TTP---PHP* For use with 2 ---speed Air Conditioner --- deg. F/C, Auto Changeover, 7 ---Day Programmable --- THERMOSTAT --- TP --- PRH* PROGRAMMABLE For use with 1 ---speed Air Conditioner --- deg. F/C, 5 ---2 Day Programmable --- TP ---PAC For use with multi ---stage applications --- deg. F/C, Auto Changeover, 7 ---Day Programmable --- TC --- PHP} For multi ---use / stage configurations --- deg. F/C, Auto Changeover, 7 ---Day Programmable/Temperature and Humidity Control ---TP---PRH{ 2 ---Zone kit --- ZONEKIT2ZCAR 2 ---Zone kit/temperature and Humidity Control --- ZONECC2KIT01 ---B ZONING CONTROL 4 ---Zone kit/temperature and Humidity Control --- ZONECC4KIT01 ---B 8 ---Zone kit/temperature and Humidity Control --- ZONECC8KIT01 ---B *Model HP and 2S thermostat must be field converted to air conditioner operation. {Thermidistatt Control control can be configured for multiple use and staging. It must be configured for each specific application. }Dual Fuel thermostat is used with furnace and heat pump application. 3

CARRIER ACCESSORIES DESCRIPTION /PH PART NO. 045---08 070---16 090---16 110---20 135---20 FILCCCAR0016 Cartridge Media Filter FILCCCAR0020 FILCCCAR0024 EPUNV0016 EPUNV0020 EZ Flex Media Filter with End Caps EPUNV0024 EPFIL0016 Replacement EZ Flex Filter Media EPFIL0020 EPFIL0024 External Bottom Return KGAFR0401B14 KGAFR0501B17 Filter Rack KGAFR0601B21 KGAFR0701B24 External Side Return Filter Rack KGAFR0801SRE KGAWF1306UFR S{ S { S { Unframed Filter 1 in. (25mm) KGAWF1406UFR KGAWF1506UFR Flue Extension KGAFE0112UPH Combustible Floor Base KGASB0201ALL Downflow Vent Guard KGAVG0101DFG Vent Extension Kit KGAVE0101DNH Chimney Adapter Kit KGACA02014FC Chimney Adapter Kit KGACA02015FC Natural --- to --- Propane Conversion Kit* KGANP4601ALL Propane --- to --- Natural Conversion Kit* KGAPN3901ALL Label Kit KGALB0101KIT Air Leakage Kit (Qty 10) KGBAC0110DGK KGAHA0150N42 KGAHA0250N43 (factory supplied) KGAHA0350N44 KGAHA0450N45 Gas Orifice Kit (Qty 50) KGAHA0550N46 KGAHA1550N47 KGAHA1650N48 KGAHA0650P54 KGAHA0750P55 See Installation Instructions for model, altitude, and heat value usages. *Factory---authorized and field---installed. Gas conversion kits are CSA (AGA/CGA) recognized. {Suitable for side return. Available accessory 4

PHYSICAL DATA UNIT SIZE 045---08 070---16 090---16 110---20 135---20 OUTPUT CAPACITY 58PH Upflow; all 36,000 53,000 72,000 90,000 107,000 BTUH (Nonweatherized ICS) 58PH Downflow/Horizontal 34,000 51,000 69,000 86,000 102,000 INPUT BTUH 58PH Upflow; all 44,000 66,000 88,000 110,000 132,000 58PH Downflow/Horizontal 42,000 63,000 84,000 105,000 126,000 AFUE% Nonweatherized ICS 80.0 80.0 80.0 80.0 80.0 SHIPPING WEIGHT LB. (KG) 104 (47) 126 (57) 140 (64) 152 (69) 163 (74) CERTIFIED TEMP RISE RANGE F (C) 30---60 25---55 35---65 30---60 40---70 (17 --- 33) (14 --- 31) (19 --- 36) (17 --- 33) (22 --- 39) CERTIFIED ET STATIC Heating 0.10 0.12 0.15 0.20 0.20 PRESSURE Cooling 0.50 0.50 0.50 0.80 0.50 AIRFLOW CFM Heating 735 1230 1345 1890 1865 Cooling 1035 1460 1665 2040 2070 LIMIT CONTROL SPST HEATING BLOWER CONTROL Solid--- State Time Operation BURNERS (Monoport) 2 3 4 5 6 GAS CONNECTION SIZE 1/2 --- in. NPT GAS VALVE(Redundant) Manufacturer White --- Rodgers Minimum Inlet Pressure (in. wc) 4.5 (Natural Gas) Maximum Inlet Pressure (in. wc) 13.6 (Natural Gas) IGNITION DEVICE Hot Surface *Gas input ratings are certified for elevations to 2000 ft. (610 M)*. For elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft. (305 M) above sea level. Refer to National Fuel Gas code Table F4 or furnace Installation Instructions. In Canada, derate the unit 10 percent for elevations 2000 to 4500 ft. (610 --- 1372 M) above sea level. {Capacity in accordance with U.S. Government DOE test procedures. }Airflow shown is for bottom only return---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for each return---air supply. An airflow reduction of up to 7 percent may occur when using a Carrier 4---5/15 in. (110 mm) high efficiency media filter. ICS --- Isolated Combustion System BLOWER PERFORMANCE DATA UNIT SIZE 045---08 070---16 090---16 110---20 135---20 DIRECT---DRIVE MOTOR Hp (ECM --- 5 Speed) 1/2 3/4 3/4 1 1 MOTOR FULL LOAD AMPS 6.8 8.4 8.4 10.9 10.9 RPM (Nominal) --- SPEEDS 1050---5 1050---5 1050---5 1050---5 1050---5 10 x 6 11 x 8 1010 11 x 11 11 x 11 BLOWER WHEEL DIAMETER x WIDTHS --- IN (MM) (254 x 152) (279 x 203) (254 x 254) (279 x 279) (279 x 279) 5

SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,3,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 UPFLOW UPFLOW DOWNFLOW A02058 A02059 A02061 SEE NOTES:1,2,3,4,5,7,8,9 SEE NOTES: 1,2,3,4,7,8,9 SEE NOTES: 1,2,4,5,6,7,8,9 DOWNFLOW DOWNFLOW DOWNFLOW A02060 A02063 A02062 Venting Notes 1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC), NFPA54/ANSI Z223.1. In Canada, latest edition of the National Standards of Canada, Natural Gas and Propane Installation Code (NSCNGPIC), CSA B149.1-00. 2. Immediately increase to 5 -in. vent connector outside furnace casing when 5 -in. vent connector required, refer to Note 1. 3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when KGAVG0101DFG is used in downflow position. 4. Type B vent where required, refer to Note 1. 5. 4 in. single wall vent must be used inside furnace casing and the KGAVG0101DFG Downflow Vent Guard Kit. 6. Accessory Downflow Vent Guard Kit, KGAVG0101DFG required in downflow installations with bottom vent configuration. 7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kit, KGACA02014FC and KGACA02015FC for sizing and complete application details. 8. Secure vent connector to furnace elbow with (2) corrosion -resistant sheet metal screws, space approximately 180_ apart. 9. Secure all other single wall vent connector joints with (3) corrosion -resistant screws spaced approximately 120_ apart. Secure Type B vent connectors per vent connector manufacturer s recommendations. 6

SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL RIGHT A02068 HORIZONTAL RIGHT A02070 SEE NOTES: 1,2,4,7,8,9 HORIZONTAL RIGHT A02069 SEE NOTES: 1,2,4,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT A02064 HORIZONTAL LEFT A02065 SEE NOTES: 1,2,4,5,7,8,9 SEE NOTES: 1,2,4,5,7,8,9 HORIZONTAL LEFT A02066 HORIZONTAL LEFT A02067 7

Air Delivery --- CFM (With Filter)* UNIT SIZE 045---08 070---16 090---16 110---20 135---20 RETURN---AIR SUPPLY Bottom or Side(s) Bottom or Side(s) Bottom or Side(s) Bottom or Side(s) Bottom or Side(s) SPEED ETERNAL STATIC PRESSURE (in. wc) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 5 1185 1145 1115 1075 1035 980 905 820 720 580 4 920 880 835 800 755 720 680 645 605 540 3 735 685 625 585 530 490 435 395 345 295 2 820 765 725 670 630 580 545 490 455 405 1 650 595 535 490 430 390 330 280 235 --- --- 5 1625 1585 1535 1495 1460 1415 1365 1295 1220 1125 4 1405 1360 1320 1280 1240 1195 1155 1115 1070 1030 3 1240 1200 1155 1110 1065 1020 975 935 895 850 2 1190 1140 1095 1050 1000 955 915 870 830 790 1 1035 985 930 885 835 785 745 695 650 600 5 1845 1800 1755 1710 1665 1595 1500 1400 1275 1105 4 1590 1545 1500 1455 1410 1365 1315 1270 1180 1000 3 1365 1320 1270 1215 1170 1125 1070 1025 955 900 2 1225 1160 1110 1060 1010 950 895 830 770 710 1 1100 1030 960 875 805 730 645 570 505 425 5 2255 2205 2150 2100 2040 1985 1920 1835 1735 1615 4 1600 1525 1465 1400 1335 1275 1210 1150 1080 1015 3 1945 1890 1830 1770 1715 1655 1600 1545 1480 1430 2 1420 1340 1280 1200 1140 1065 1005 925 865 790 1 1280 1205 1140 1055 990 910 840 760 695 630 5 2295 2240 2185 2125 2070 2005 1925 1805 1670 1545 4 1725 1660 1605 1545 1460 1395 1340 1285 1230 1170 3 1910 1865 1800 1745 1685 1610 1545 1485 1435 1380 2 1630 1575 1510 1435 1365 1300 1245 1185 1130 1065 1 1430 1355 1285 1200 1125 1075 1015 945 855 800 *A filter is required for each return ---air inlet. Airflow performance included 1---in. (25 mm) washable filter media such as contained in factory---authorized accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 in. wc available external static pressure. --- --- Indicates unstable operating conditions. ELECTRICAL DATA /P H UNIT SIZE VOLTS --- HERTZ --- PHASE OPERATING VOLTAGE RANGE* Maximum Minimum MAIMUM UNIT AMPS MAIMUM WIRE LENGTH FT (M)} MAIMUM FUSE OR CKT BKR AMPS{ MINIMUM WIRE GAGE 045--- 08 115 --- 60 --- 1 127 104 8.1 34 (10) 15 14 070--- 16 115 --- 60 --- 1 127 104 9.5 29 (9) 15 14 090--- 16 115 --- 60 --- 1 127 104 10.3 27 (8) 15 14 110--- 20 115 --- 60 --- 1 127 104 13.1 34 (10) 20 12 135--- 20 115 --- 60 --- 1 127 104 13.1 34 (10) 20 12 * Permissible limits of the voltage range at which the unit operates satisfactorily. { Time---delay type is recommended. }Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop. 8

DIMENSIONS (664mm) 26-1/8" (FLUE COLLAR) (22mm) 7/8" DI A ACCESSORY 5-15/16" (733mm) 28-7/8" (641mm) 25-1/4" 22-9/16" (573mm) JUNCTION BO LOCATION 1/2" DIA THERMOSTAT WIRE ENTRY A D F 13/16" (21mm) 4-13/16" (122mm) 8-9/16" (217mm) 2-7/16" (62mm) 1-5/16" (33mm) 1-1/8" (29mm) AIRFLOW 19" (483mm) OUTLE T 1/2" DIA. K.O.THERMOSTAT WIRE ENTRY (13mm) 1-3/4" DIA.RIGHT HAND GAS ENTRY (44mm) 13/16" (21mm) 9-5/8" 11/16" 7-3/4" (17mm)(197mm) (244mm) 11-1/2" (292mm) 3-15/16" LEFT HAND GAS ENTRY 33-5/16" 24-7/8" (846mm) (632mm) ALTERNAT E JUNCTION BO LOCATIONS (TYP) 7/8" DIA. K.O. WIRE ENTRY (22mm) 11/16" (17mm) 7/8" DIA. ACCESSORY (549mm) 21-5/8" BOTTOM INLE T 24" CASING (610mm) 1-11/16" (43mm) 5-1/2" (140mm) E 11/16" (17mm) VENT OUTLE T 5 PLACES (TYP) 5-1/2" (140mm) 3-3/4" (95mm) 7/8" DIA. ACCESSORY (22mm) 1-1/2" (38mm) (560mm) 22-1/16" SIDE INLE T 14-7/8" (378mm) 1-1/4" (32mm) 1" (25mm) A04037 1. Two additional 7/8 -in. (22 mm) dia. knockouts are located in the top plate. 2. Minimum return -air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer s recommendations for equivalent diameters. 3. Minimum return -air opening at furnace. a. For 800 CFM -16 -in. (406 mm) round or 14-1/2 x 12 -in. (368 x 305 mm) rectangle. b. For 1200 CFM -20 -in. (508 mm) round or 14-1/2 x 19-1/3 in. (368 x 491 mm)rectangle. c. For 1600 CFM -22 -in. (559 mm) round or 14-1/2 x 22-1/16 -in. (368 x 560 mm) rectangle. d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom of single side inlets. The use of both side inlets, a combination of one side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM. /PH UNIT SIZE A CABINET WIDTH IN (MM) D SUPPLY WIDTH IN (MM) E BOTTOM RETURN WIDTH IN (MM) F TOP VENT OUTLET IN (MM) VENT CONNECTION SIZE (see Notes 1 & 2) MEDIA CABINET SIZE IN (MM) 045--- 08 14--- 3/16 (360) 12--- 9/16 (319) 12--- 11/16 (322) 9--- 5/16 (237) 4 16 (406) 070--- 16 17--- 1/2 (445) 15--- 7/8 (403) 16--- 1/8 (410) 11--- 9/16 (294) 4 16 (406) 090--- 16 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13--- 5/16 (338) 4 20 (508) 110--- 20 21 (533) 19--- 3/8 (492) 19--- 1/2 (495) 13--- 5/16 (338) 4 20 (508) 135--- 20 24--- 1/2 (622) 22--- 7/8 (581) 23 (584) 15--- 1/16 (383) 4(Note1) 24 (610) 1. 135 size furnaces require 5---in. (127 mm) vents. Use a 4---5 in. (102---127 mm) vent adaptor between furnace and vent stack. 2. See installation instructions for complete installation requirements. 9

Ø * INSTALLATION MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION DISTANCE MINIMALE EN POUCES AU CONSTRUCTIONS COMBUSTIBLES This forced air furnace is equipped for use with natural gas at altitudes 0-10,000 ft (0-3,050m). An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications. This furnace is for indoor installation in a building constructed on site. This furnace may be installed on combustible flooring in alcove or closet at minimum clearance as indicated by the diagram from combusitble material. This furnace may be used with a Type B-1 Vent and may be vented in common with other gas fired appliances. Cette fournaise à air pulsé est équipée pour utilisation avec gaz naturel et altitudes comprises entre 0-3,050m (0-10,000 pi). Utiliser une trousse de conversion, fournie par le fabricant, pour passer au gaz propane ou pour certaines installations au gaz naturel. Cette fournaise est prévue pour être installée dans un bâtiment construit sur place. Cette fournaise peut être installée sur un plancher combustible dans une alcôve ou dans un garde-robe en respectant le minimum d'espace libre des matériaux combustibles, tel qu indiqué sur le diagramme. Cette fournaise peut être utilisée avec un conduit d évacuation de Type B-1 ou connectée au conduit ommun d 'autres appareils à gaz. This furnace is approved for UPFLOW, DOWNFLOW, and HORIZONTAL installations. Cette fournaise est approuvée pour l 'installation HORIZONTALE et la circulation d 'air VERS LE HAUT et VERS LE BAS. Clearance arrows do not change with furnace orientation. 0" * B A A R C R K I È R E 0" S I DE C Ô T É 1" TOP / PLENUM DESSUS / CHAMBRED'AIR BOTTOM DESSOUS 0" F URNACE FOURNAISE Les fléches de dégagement ne change pas avec l 'orientation de la fournaise. FRONT AVANT F R A O V N A T N T 3" Ø S I DE C Ô T È S E E NTRR VI MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION DOWNFLOW POSITIONS: Installation on non-combusibible floors only. For Installation on combustible flooring only when installed on special base, Part No. KGASB0201ALL, Coil Assembly, Part No. CD5 or CK5, or Coil Casing, Part No. KCAKC. Ø 18 inches front clearance required for alcove. Indicates supply or return sides when furnace is in the horizontal position. Line contact only permissible * between lines formed by intersections of the Top and two Sides of the furnace jacket, and building joists, studs or framing. DÉGAGEMENT MINIMUM EN POUCES AVEC ÉLÉMENTS DE CONSTRUCTION COMBUSTIBLES POUR LA POSITION COURANT DESCENDANT: Pour l installation sur plancher non combustible seulement. Pour l installation sur un plancher combustible seulement quand on utilise la base spéciale, pièce nº KGASB0201ALL, l ensemble serpentin, pièce nº CD5 ou CK5, ou le carter de serpentin, pièce nº KCAKC. Dans une alcôve, on doit maintenir un dégagement à l avant de 18 po (450mm). La poistion indiquée concerne le côté d entrée ou de retour quand la fournaise est dans la position horizontale. Le contact n est permis qu entre les lignes formées par les intersections du dessus et des deux côtés de la cherrise de la fournaise et les solives, montant sous cadre de charpente. MIN E T C E E N 0" 24" MIN 327590-101 REV. C I * Clearance in inches Dégagement (po). Vent Clearance to combustibles: For Single Wall vents 6 inches (6 po). For Type B-1 vent type 1 inch (1 po). Dégagement de l évent avec combustibles: Pour conduit d évacuation à paroi simple 6 po (6 inches). Pour conduit d évacuation de Type B-1 1 po (1 inch). A04123 C E DE S R T I I GN I F E D EFFICIENCY RATING CERTIFIED CERTIFIED Car r i er Cor por ation R EGIS TER ED ISO ISO 9001:2000 9001 FIR M REGISTERED #A2883 REGISTERED QUALITY SYSTEM MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. 25 5 /8" (651mm) 23 5 /8" (600mm) 23 3 /8" (600mm) 24 1 /2" (651mm) With Flanges Bent Out 23 1 /8" (587mm) Opening A B C Opening with Flanges Bent In Furnace Side Duct Side 23 3 /4" Centerline Screw Slots (603mm) 5 3 /4" (146mm) Media/ Filter Cabinet A B C 16"/ 17"/ 16 1 / (406mm) 4"/ 15"/ (432mm) (413mm) (381mm) 20"/ 21"/ 20 1 / 4"/ 19"/ (508mm) (533mm) (514mm) (483mm) 24"/ 25"/ 24 1 / (610mm) 4"/ 23"/ (635mm) (616mm) (584mm) A00444 10

TYPICAL WIRING SCHEMATIC FIELD 24-V WIRING FIELD 115-, 208/230-, 460-V WIRING FACTORY 24-V WIRING FACTORY 115-V WIRING THREE-WIRE HEATING-ONLY BLOWER DOOR SWITCH BLK WHT GND BLK WHT 115-V FIELD- SUPPLIED DISCONNECT FIVE WIRE GND AUILIARY J-BO NOTE 2 C O NT R O L W R G COM Y/Y2 24-V TERMINAL BLOCK FURNACE W C R G Y NOTE 1 NOTES: 1. 2. 3. THERMOSTAT TERMINALS CONDENSING UNIT TWO WIRE FIELD-SUPPLIED DISCONNECT GND 208/230- OR 460-V THREE PHASE 208/230-V SINGLE PHASE Connect Y-terminal in furnace as shown for proper blower operation. Some thermostats require a "C" terminal connection as shown. If any of the original wire, as supplied, must be replaced, use same type or equivalent wire. A99440 TYPICAL INSTALLATION CONDENSING UNIT HUMIDIFIER ELECTRONIC AIR CLEANER GAS-FIRED WATER HEATER AIRFLOW A02184 11

GUIDE SPECIFICATIONS Gas Furnace /PH GENERAL System Description Furnish a fixed capacity gas-fired furnace for use with natural gas or propane (factory authorized conversion kit required for propane); furnish cold air return plenum; furnish external medial cabinet for use with accessory media filter or standard filter. Quality Assurance Unit will be designed, tested and constructed to the current ANSI Z 21.47/CSA 2.3 design standard for gas -fired central furnaces. Unit will be 3rd party certified by CSA to the current ANSI Z 21.47/CSA 2.3 design standard for gas -fired central furnaces. Unit will carry the CSA Blue Star and Blue Flame labels. Unit efficiency testing will be performed per the current DOE test procedure as listed in the Federal Register. Unit will be certified for capacity and efficiency and listed in the latest GAMA Consumer s Directory of Certified Efficiency Ratings. Unit will carry the current Federal Trade Commission Energy Guide efficiency label. Delivery, Storage and Handling Unit shall be shipped as single package only and is stored and handled per unit manufacturer s recommendations. Warranty (for inclusion by specifying engineer) U.S. and Canada only. Warranty certificate available upon request. PRODUCTS Equipment Components shall include: slow -opening gas valve to reduce ignition noise, regulate gas flow, with electric switch gas shut -off; flame proving sensor, hot surface igniter, pressure switch assembly; flame rollout switch, blower and inducer assembly, 40va transformer; low -voltage (heating) (heating/ cooling) thermostat. Blower Wheel and Blower Motor Galvanized blower wheel shall be centrifugal type, statically and dynamically balanced. Blower motor of ECM type shall be permanently lubricated with sealed bearings, of hp, and shall be multiple -speed direct drive. Blower motor shall be soft mounted to the blower scroll to reduce vibration transmission. Filters Furnace shall have reusable -type filters. Filter shall be in (x) in. An accessory high efficiency Media Filter is available as an option. Media Filter. Casing Casing shall be of.030 in. thickness minimum, pre-painted galvanized steel. Inducer Motor Inducer motor shall be soft mounted to reduce vibration transmission. Draft Safeguard Switch Draft Safeguard Switch (blocked vent safeguard) shall be factory installed to reduce the possibility of vent gas infiltration due to a blocked or restricted vent pipe. Heat Exchangers Heat exchangers shall be a 4 -Pass 20 gage aluminized steel of fold -and -crimp sectional design when applied operating under negative pressure. Controls Control shall include a micro -processor based integrated electronic control board with at least 11 service troubleshooting codes displayed via diagnostic flashing LED light on the control, a self-test feature that checks all major functions of the furnace within one minute, and a replaceable automotive -type circuit protection fuse. Multiple operational settings available including, separate blower speeds for heating, cooling and continuous fan. Continuous fan speed may be adjusted from the thermostat. Features will also include temporary reduced airflow in the cooling mode for improved dehumidification when a Thermidistatt Control is selected as the thermostat. Operating Characteristics Heating Capacity shall be Btuh input; Btuh output capacity. Fuel Gas Efficiency shall be 80% AFUE. Air delivery shall be CFM minimum at 0.50 in. wg external static pressure. Dimensions shall be: depth in.; width in; height in. (casing only). Height shall be in. with A/C coil and in. overall with plenum. Electrical Requirements Electrical supply shall be 115 volts, 60 Hz, single-phase (nominal). Minimum wire size shall be AWG; maximum fuse size or HACR -type designated circuit breaker shall be Amps. Special Features Refer to section of the product data sheet identifying accessories and descriptions for specific features and available enhancements. Copyright 2008 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 03/08 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: ---01PD Replaces: NEW 12