苏州虹淦贸易有限公司. Suzhou Honggan Imp&Exp Co.,Ltd

Similar documents
HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

MODULAR CHILLER. R410a R22

Air Cooled Scroll Chiller

GENERAL INFORMATIONS

DAIKIN Huizhou Factory Profile

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

AIRSYS-P-SC-MOBILECOOL-OUTDOOR-E1509V01.5 MOBILECOOL-OUTDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.5kW-13.

.2 Section Waste Management and Disposal.

500 EX Fusion Compressor Series

Modular Air Cooled Scroll Chillers

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

Ultimate energy saving technology

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

ULTIMATE ENERGY SAVING TECHNOLOGY

Ultimate energy saving technology

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Industrial cooling solutions

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

MODELS LIST. Nominal Capacity RT

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Capacity kw G SERIES. Value range of general-purpose industrial chillers

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

OACS Outdoor Air-Cooled Central Chillers

3 0 H X C A - H P 2

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

How To Make Lando Water Chillers? Leading the way of innovation. Here is the instruction to know more us how to

KELVIN Clim F497. Kelvin air conditioning

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

Daikin LXE10E Technical Information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Air cooled industrial chillers

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Bench-Top Type Temperature (& Humidity) Chamber

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

SCA 620C AIR COOLED SCREW CHILLER

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)

The High-efficiency Water-cooled Chiller "H series"

GLIDER EVO GLIDER EVO. rcgroupairconditioning

Air Cooled Chillers & Heat Pumps WinPACK HE-A

PURESTREAM CHILL-CUBE TM BY FRIULAIR

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS

Hi-Pres Cooling Products Catalogue. Product Catalogue

AQUASNAP JUNIOR 30RHV

30RH B Nominal cooling capacity kw Nominal heating capacity kw

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

ACMVTECH HIGH EFFICIENCY UNITARY AHU

SECTION AIR COOLED WATER CHILLERS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

RAK THE OPTIMUM RANGE FROM REFCOOL THE ENERGY REVOLUTION. Industrial chillers - 0 to 200 kw

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Water-cooled Centrifugal Chiller

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

DRYTEC REFRIGERANT DRYERS

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future!

H4T R410A. refrigerant

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

COLDPACK_. water cooled chillers / heat pumps and condenserless chillers

pyxis u pyxis ua NEW rcgroupairconditioning

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

ARV.

Scroll Water Cooled Chiller

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

SECTION CHILLERS

Precise Temperature Control; Compact Footprint

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Transcription:

1 苏州虹淦贸易有限公司 Suzhou Honggan Imp&Exp Co.,Ltd Industrial water chiller Supplier: Suzhou AOTC Machinery Co., Ltd. Address: No.218 Jiyang middle road, Zhangjiagang City, Jiangsu Province, China. Fax: 0086-512-55379103 Contact person: Peter Mobile phone: 0086-18751167225 MSN:maomao201101@hotmail.com E-mail: hongganmy@yahoo.cn

2 Contents Part 1. Company Introduction. 3 Part 2. Introductions of AOTC industrial chiller.4 Part 3. Features of AOTC industrial chiller..4 Part 4. Specification...5-16 4.1. Water-cooled chiller series.....5-6 4.2. Air-cooled chiller series.......7-8 4.3. Water-cooled screw chiller.....9-12 4.4. Air-cooled screw chiller series..13-16 Part 5. After-sales service...17 Part 6. Photos Show..18 Part 7. Process Cooling Chiller Selection Table 19

3 Part 1. Company Introduction AOTC Machinery CO.,Ltd.is a company under AODE Machinery(Hong Kong)CO.,Ltd.,engaging in temperature control system for more than 10 years. AODE has set up 3 manufacturing facilities in Shenzhen, Kunshan and Tianjin,and Aulank Pump Manufacturing CO.,Ltd.for the matching water pumps,to cope with the requirements of customers.in recent years,we have always maintained the good partnership with manufacturers in Austria,US,France,Japan and Germany for providing the OEM services.we learned from the high standard design and quality requirements in foreign countries through the cooperation,and won the high praise from counterparts and customers. AOTC has established the practical and efficient quality management system,to effectively ensure the product development,design,manufacture,etc.;and adopted the high quality materials and introduced the state-of-art production technologies and processing equipment,to improve the product quality and the market competitiveness.our products are sold to all over China,Southeast Asia,Europe,US and other areas. "Good faith and high integrity"is the perpetual pursuit of the personnel of AOTC and AODE."Hot or cold in industry,aotc cares".let's hope OTC will provide customers with the most satisfactory products and most considerate services in the 21century,and join hands with customers to create a better future of the manufacturing industry! Factory in Shenzhen Factory in Tianjin Factory in Suzhou

4 Part 2. Introductions of AOTC industrial chiller In the modern industrial processes, the accurate temperature control is a key factor for improving the productivity and the product quality, and the competitive edage of manufacturing companies relies on the chiller for reducing temperature, improving product quality and production efficiency, and increasing the profit. To meet the requirements of customers, we offer a series of new design industrial chillers and supporting equipment for plastic machinery and perfect services aiming to minimize the productions costs. The industrial chillers are used widely in various industries, e.g. the cast blank and suction molding for the plastic production, to shorten the production cycle and improving the surface finish and transparency; and stabilizing the metallic ions and making it quickly adhering to the companents in the electroplating process; and also used in the chemical, hardware, food, blanching and dyeing, fishery, sauna, central air conditioning and other industries with the need of refrigerating! Part 3. Features of AOTC industrial chiller 1. High/low pressure protection for the compressor and overheating protection inside the machine. 2. Low water level alarm and low water temperature alarm. 3. Imported compressor from Europe, US and Japan. 4. Refrigerating system welded with oxygen free method,to reduce oxides and ensure the smooth surface. 5. Throttle components from Danfoss(Denmark) and Alco(US). 6. SUS304 stainless steel water tank, to avoid corrosion or water leak. 7. Stainless plate, coil, shell and tube or fin type efficient heat exchanger 8. RS485 communication function, to realize automatic management(optional). 9. Electrical devices supplied from OMRON, FUJI, TE, LG.MOELLER and SCHNEIDER. 10.Control mode: imported micro-computer of PLC(optional). 11. Perfect safety protection, failure display, and not requiring professional personnel for maintenance. 12. Highly efficient evaporator and condenser, to save over 30% energy. Part 4. Specification

5 4.1 Water-cooled chiller series Specification A Parameter AC-03W AC-04W AC-05W AC-06W AC-08WD AC-10WD AC-12WD AC-15WD KW 50HZ 9.59 12.43 15.91 19.18 24.85 31.83 38.37 50.14 Cooling Capacity Kcal/h 50HZ 8251 10682 13690 16503 21375 27370 32994 43120 Total Input KW 2.8 3.55 4.5 5.4 6.8 8.4 10.1 13.1 Maximum Running current A 6.7 8.4 10.4 12.6 16.5 20.4 24.6 31.8 Refrigerant Power Supply 3N~380V 50HZ Name Charge Kg 1.7 2.2 2.8 3.4 2.2*2 2.8*2 3.4*2 4.2*2 Control Capillary Tube External Balanced Thermostatic Expansion Valve Hermetic Scroll or Piston Compressor Motor KW 2.25 3 3.75 4.5 3*2 3.75*2 4.5*2 5.5*2 Flow M 3 /h 2.06 2.67 3.42 4.13 5.34 6.85 8.24 10.78 Cooling Water In/Out Pipe G3/4'' G3/4'' G1'' G1-1/2'' G1-1/2'' G1-1/2'' G2'' G2'' Chilled Water Flow M 3 /h 1.65 2.14 2.74 3.30 4.27 5.47 6.59 8.62 Tank M 3 0.038 0.038 0.065 0.08 0.11 0.188 0.188 0.285 In/Out Pipe G3/4'' G3/4'' G1'' G1'' G1-1/2'' G2'' G2'' G2'' Motor KW 0.375 0.375 0.75 0.75 0.75 1.5 1.5 1.5 Water Pump Pressure Kpa 242 242 290 290 290 205 205 205 Length MM 830 830 1080 1080 1300 1300 1600 1675 Width MM 460 460 580 580 610 610 750 750 Height MM 1020 1020 1230 1230 1445 1445 1445 1608 Weight Kg 120 140 150 200 210 290 310 400 Remark: 1.Cooling capacity reference, Inlet 15 cold water, Outlet 10 cold water, amiet temperature 35 2.We reserve the right to make changes to the above specification without notification 3.Besides above standard models, some special models could be custom-made as your requirements.

6 Specification B Parameter AC-20WD AC-25WD AC-30WT AC-35WT AC-40WF AC-45WF AC-50WE AC-60WE KW 50HZ 67.14 81.53 99.19 117.28 129.06 148.68 153.91 198.12 Cooling Capacity Kca/h 50HZ 57748 70120 85303 100869 110984 127868 132359 170383 Total Input KW 17.3 21.3 25.6 29.4 33.1 38.6 42.5 59 Maximum Running current A 42.1 48.5 58.3 65.4 75.4 80.6 88.4 101.92 Power Supply 3N~380V 50HZ Name Refrigerant Charge Kg 5*2 6.3*2 5*3 6.2*3 5*4 5.6*4 5*5 6.24*5 Control External Balanced Thermostatic Expansion Valve Hermetic Scroll or Piston Compressor Motor KW 7.5*2 9.4*2 7.5*3 9*3 7.5*4 9*4 7.5*5 9*5 Flow M 3 /h 14.44 17.54 21.32 25.22 27.74 31.98 33.09 41.6 Cooling Water P.D. Kpa 38 30 36 37 35 40 42 45 In/Out Pipe G2'' G2'' G2-1/2'' G2-1/2'' G3'' G3'' G3'' G3'' Flow M 3 /h 11.55 14.03 17.06 20.18 22.19 25.58 26.48 33.28 Chilled Water Tank M 3 0.285 0.405 0.405 0.405 0.61 0.61 0.61 0.61 In/Out Pipe G2-1/2'' G2-1/2'' G2-1/2'' G3'' G3'' G3'' G3'' G3'' Motor KW 2.2 2.2 4 4 4 4 4 4 Water Pump Pressure Kpa 220 220 250 250 250 250 250 250 Length MM 1880 1880 2130 2100 2200 2200 2200 2400 Width MM 914 914 940 1020 1000 1070 1070 1150 Height MM 1785 1790 1785 2000 1940 2100 2100 2200 Weight Kg 440 620 690 760 850 950 1000 1100

7 4.2 Air-cooled chiller series Specification A Parameter AC-1/2A AC-01A AC-02A AC-03A AC-04A AC-05A AC-06A AC-08AD KW 50HZ 1.53 2.94 5.67 8.39 10.90 13.95 16.90 21.80 Cooling Capacity Kca/h 50HZ 1316 2528 4872 7216 9374 11990 14530 18748 Total Input KW 0.68 1.31 2.6 3.6 4.5 5.5 6.6 8.6 Maximum Running current A 4.1 8 15.8 8.8 10.9 13.4 16 20.9 Refrigerant Power Supply 1N~220V 50HZ 3N~380V 50HZ Name Charge Kg 0.6 0.8 1.8 2.7 3.5 4.6 5 3.5*2 Control Capillary Tube Hermetic Rotary Hermetic Scroll or Piston Compressor Motor KW 0.55 0.75 1.5 2.25 3 3.75 4.5 3*2 Chilled Water Air Flow M 3 /h 800 1000 2000 3000 4000 5000 6000 8000 Flow M 3 /h 0.26 0.51 0.97 1.44 1.87 2.40 2.91 3.75 Tank M 3 0.022 0.028 0.038 0.06 0.06 0.07 0.11 0.11 In/Out Pipe G1/2'' G1/2'' G3/4'' G3/4'' G3/4'' G1'' G1'' G1''-1/2'' Motor KW 0.375 0.375 0.375 0.375 0.375 0.75 0.75 0.75 Water Pump Pressure Kpa 180 180 250 242 242 290 290 290 Length MM 600 600 820 945 945 1035 1200 1470 Width MM 400 400 460 550 550 610 650 710 Height MM 940 940 1170 1370 1370 1385 1480 1700 Weight Kg 45 60 120 130 160 170 250 270 Remark: 1.Cooling capacity reference, Inlet 15 cold water, Outlet 10 cold water, amiet temperature 35 2.We reserve the right to make changes to the above specification without notification 3.Besides above standard models, some special models could be custom-made as your requirements.

8 Specification B Parameter AC-10AD AC-12AD AC-15AD AC-20AD AC-25AD AC-30AT AC-40AF AC-50AE AC-60AE KW 50HZ 28.01 33.79 44.15 59.08 71.72 87.20 113.58 135.49 181.68 Cooling Capacity Kca/h 50HZ 24089 29059 37965 50805 61683 74992 97675 116521 156249 Total Input KW 11 13.3 17 22.8 27.7 33.7 42.8 51.1 68.8 Maximum Running current A 26.7 32.3 41.3 55.4 63.1 76.8 97.5 116.5 143.1 Power Supply 3N~380V 50HZ Name Charge Kg 4.3*2 5*2 6.5*2 8.5*2 10.5*2 8.3*3 8.5*4 8.2*5 9.96*5 Refrigerant Capillary Control Tube External Balanced Thermostatic Expansion Valve Hermetic Scroll or Piston Compressor Motor KW 3.75*2 4.5*2 5.5*2 7.5*2 9.4*2 7.5*3 7.5*4 7.5*5 9*5 Air Flow M 3 /h 10000 12000 15000 20000 25000 30000 40000 48000 66000 Flow M 3 /h 4.82 5.81 7.60 10.16 12.34 15.00 19.53 23.3 30.52 Chilled Water Tank M 3 0.188 0.188 0.285 0.285 0.405 0.405 0.61 0.61 0.7 In/Out Pipe G2'' G2'' G2'' G2'' G2-1/2'' G2-1/2'' G3'' G3'' G3-1/2'' Motor KW 1.5 1.5 1.5 2.2 2.2 4 4 4 4 Water Pump Pressure Kpa 205 205 205 220 220 250 250 250 250 Length MM 1470 1470 1680 1955 2080 2080 2565 3556 3556 Width MM 710 800 890 940 1000 1000 1220 2200 2200 Height MM 1700 1780 1900 1960 2055 2055 2310 2210 2210 Weight Kg 350 370 520 590 790 880 1100 1280 1420

9 4.3 Water-cooled Screw chiller series Specification A Item Cooling Capacity AC-100WS AC-130WS AC-170WS AC-190WS AC-255WS AC-300WS Kca/h 86,000 111,800 146,200 163,400 219,300 258,000 KW 100 130 170 190 255 300 Total Input KW 22 30 36 45 56 61 Maximum Running current A 38 51 61 76 95 103 Capacity Control % 100-75-50-25-0 Power Supply 3N-50HZ-380V Charge Kg 17 22 28 35 42.5 50 Refrigerant Control Thermostatic Expansion Valve Screw Semi-hermetic Compressor Motor KW 22 30 36 45 56 61 Evaporator Condenser Safety Device Flow Rate M 3 /h 17.2 22.4 29.3 36.6 43.9 51.6 Pressure Drop Kpa 33 33 38 42 45 42 In/Out Pipe DN 65.0 65.0 65.0 80.0 80.0 100.0 Flow Rate M 3 22.4 29.2 35.2 46.1 57.1 37.1 Pressure Drop Kpa 38 43 43 48 48 45 In/Out Pipe DN 65.0 65.0 65.0 80.0 80.0 100.0 High/Low Pressure Switch,Anti-frost Protector,Fusible Plug,Overload Protector,Motor Overheat Protector,Automatic Temperature Sensitive Switch, Anti-phase Protector. Length MM 2500 2600 2650 2800 3000 3000 Width MM 750 750 750 750 750 900 Height MM 1800 1800 1800 1800 1800 1900 Net Weight Kg 800 880 1000 1000 1500 1800 Operating Weight Kg 900 1110 1200 1200 1650 1960

10 Specification B Item Cooling Capacity AC-330WS AC-400WS AC-490WS AC-630WS AC-770WS AC-855WS Kca/h 283,800 344,000 421,400 541,800 662,200 735,300 KW 330 400 490 630 770 855 Total Input KW 70 85 114 132 167 180 Maximum Running current A 119 145 170 225 285 307 Capacity Control % 100-75-50-25-0 Power Supply 3N-50HZ-380V Charge Kg 55 67 82 105 128 143 Refrigerant Control Thermostatic Expansion Valve Screw Semi-hermetic Compressor Motor KW 70 85 114 132 167 180 Evaporator Flow Rate M 3 /h 56.8 68.8 84.3 108.4 132.4 147.1 Pressure Drop KPa 42 45 40 44 44 44 In/Out Pipe DN 100.0 100.0 125.0 150.0 150.0 150.0 Condenser Safety Device Flow Rate M 3 74 89.4 110 141 172.2 191.2 Pressure Drop KPa 45 48 45 49 49 49 In/Out Pipe DN 100.0 100.0 125.0 150.0 150.0 150.0 High/Low Pressure Switch,Anti-frost Protector,Fusible Plug,Overload Protector,Motor Overheat Protector,Automatic Temperature Sensitive Switch, Anti-phase Protector. Length MM 3100 3200 3606 3900 4200 4400 Width MM 900 900 1280 1320 1320 1320 Height MM 1900 1900 1600 1650 1650 1650 Net Weight Kg 1900 2000 2490 3200 3400 3600 Operating Weight Kg 2050 2180 2650 3500 3700 3900

11 Specification C Item AC-200WD AC-260WD AC-340WD AC-510WD AC-600WD AC-660WD Cooling Capacity Kca/h 172,000 223,600 292,400 483,600 516,000 567,600 KW 200 260 340 510 600 660 Total Input KW 44 60 72 112 122 140 Maximum Running current A 76 102 122 190 206 238 Capacity Control % 100-75-50-25-0 Power Supply 3N-50HZ-380V Charge Kg 17*2 22*2 28*2 42.5*2 50*2 55*2 Refrigerant Control Thermostatic Expansion Valve Screw Semi-hermetic Compressor Motor KW 22*2 30*2 36*2 56*2 61*2 70*2 Evaporator Condenser Flow Rate M 3 /h 34.4 44.7 58.6 87.8 103.2 114.0 Pressure Drop KPa 39 39 43 45 46 38 In/Out Pipe DN 80.0 80.0 100.0 125.0 125.0 150.0 Flow Rate M 3 44.7 58.1 76 114.2 134.2 148.2 Pressure Drop KPa 45 45 49 49 49 44 In/Out Pipe DN 80 80 100 125 125 150 Safety Device High/Low Pressure Switch,Anti-frost Protector,Fusible Plug,Overload Protector,Motor Overheat Protector,Automatic Temperature Sensitive Switch, Anti-phase Protector. Length MM 2900 3000 3150 3300 3400 4185 Width MM 750 750 750 850 850 1290 Height MM 1900 1900 1900 2000 2000 2119 Net Weight Kg 2150 2250 2700 3150 3700 4060 Operating Weight Kg 2350 2750 2800 3400 3400 4030

12 Specification D Item AC-800WD AC-980WD AC-1260WD AC-1540WD AC-17100WD Cooling Capacity Kca/h 688,000 824,800 1083,600 1324,400 1470,600 KW 800 980 1260 1540 1710 Total Input KW 170 228 264 334 360 Maximum Running current A 290 340 450 570 614 Capacity Control % 100-75-50-25-0 Power Supply 3N-50HZ-380V Charge Kg 67*2 82*2 105*2 128*2 143*2 Refrigerant Control Thermostatic Expansion Valve Compressor Screw Semi-hermetic Motor KW 85*2 114*2 132*2 167*2 180*2 Evaporator Condenser Safety Device Flow Rate M 3 /h 137.6 168.6 216.7 264.9 294.1 Pressure Drop KPa 43 50 42 46 45 In/Out Pipe DN 150.0 150.0 200.0 200.0 200.0 Flow Rate M 3 178.9 219.2 281.7 344.3 382.4 Pressure Drop KPa 48 42 48 50 50 In/Out Pipe DN 150 200 200 200 200 High/Low Pressure Switch,Anti-frost Protector,Fusible Plug,Overload Protector,Motor Overheat Protector,Automatic Temperature Sensitive Switch, Anti-phase Protector. Length MM 4285 4100 4250 4500 4700 Width MM 1290 1290 1590 1590 1590 Height MM 2119 2119 2200 2200 2200 Net Weight Kg 4060 4280 5200 5540 5740 Operating Weight Kg 4420 4660 5660 6030 6230

13 4.5 Air-cooled Screw chiller series Specification A Item Cooling Capacity AC-80AS AC-100AS AC-140AS AC-210AS AC-240AS AC-260AS Kca/h 68,800 86,000 120,400 180,600 206,400 223,600 KW 80 100 140 210 240 260 Total Input KW 33.5 43.5 53 79 86 97 Maximum Running current A 56.6 73.4 89.5 133.4 145.2 163.8 Capacity Control % 100-75-50-25-0 Power Supply 3N-50HZ-380V Charge Kg 21 26 36 54.6 62.3 67.5 Refrigerant Control Thermostatic Expansion Valve Screw Semi-hermetic Compressor Motor KW 29 39 47 73 79 91 Condenser Copper Coil With Aluminium Fine Low Noise Aluminium Blade Axial Fa Fan Air Flow M 3 /h 30000 40000 50000 72000 82000 89000 Evaporator Safety Device Flow Rate M 3 /h 13.8 17.2 24.1 36.1 41.3 44.7 Pressure Drop KPa 33 33 38 43 47 42 In/Out Pipe DN 65.0 65.0 65.0 80.0 80.0 100.0 High/Low Pressure Switch,Anti-frost Protector,Fusible Plug,Overload Protector,Motor Overheat Protector,Automatic Temperature Sensitive Switch, Anti-phase Protector. Length MM 2100 2100 2100 1900 1900 2260 Width MM 1200 1200 1200 1900 1900 2260 Height MM 2230 2230 2230 2390 2390 2390 Net Weight Kg 1100 1200 1290 1800 1850 2350 Operating Weight Kg 1200 1280 1380 1910 1970 2480

14 Specification B Item AC-330AS AC-400AS AC-510AS AC-630AS AC-700AS Kca/h 283,800 344,000 438,600 541,800 602,000 Cooling Capacity KW 330 400 510 630 700 Total Input KW 117 137.2 183.7 235.8 254 Maximum Running current A 197.5 231.6 310.1 398.1 428.9 Capacity Control % 100-75-50-25-0 Power Supply 3N-50HZ-380V Charge Kg 86 104 132.5 163.6 181.8 Refrigerant Control Thermostatic Expansion Valve Compressor Fan Evaporator Condenser Safety Device Screw Semi-hermetic Motor KW 111 130 172 218 235 Copper Coil With Aluminium Fine Low Noise Aluminium Blade Axial Fa Air Flow M 3 /h 115000 140000 175000 220000 240000 Flow Rate M 3 /h 56.8 68.8 87.7 108.4 120.4 Pressure Drop KPa 45 50 45 47 50 In/Out Pipe DN 100.0 100.0 125.0 125.0 150.0 High/Low Pressure Switch,Anti-frost Protector,Fusible Plug,Overload Protector,Motor Overheat Protector,Automatic Temperature Sensitive Switch, Anti-phase Protector. Length MM 2260 4000 4000 4000 4000 Width MM 2260 2260 2260 2260 2260 Height MM 2390 2570 2570 2570 2570 Net Weight Kg 2500 3100 3660 3850 4000 Operating Weight Kg 2640 3250 3830 4030 4200

15 Specification C Item AC-160AD AC-200AD AC-280AD AC-420AD AC-480AD AC-520AD Kca/h 137,600 182,600 240,800 361,200 412,800 447,200 Cooling Capacity KW 160 200 280 420 480 520 Total Input KW 67 87 106 158 172 194 Maximum Running current A 113.2 146.8 179 266.8 290.4 327.6 Capacity Control % 100-75-50-25-0 Power Supply 3N-50HZ-380V Charge Kg 21*2 26*2 36*2 54.6*2 62.3*2 67.5*2 Refrigerant Control Thermostatic Expansion Valve Screw Semi-hermetic Compressor Motor KW 29*2 39*2 47*2 73*2 79*2 91*2 Condenser Copper Coil With Aluminium Fine Low Noise Aluminium Blade Axial Fa Fan Air Flow M 3 /h 60000 80000 100000 144000 164000 178000 Evaporator Flow Rate M 3 /h 27.6 34.4 48.2 72.2 82.6 89.4 Pressure Drop KPa 47 47 42 50 53 47 In/Out Pipe DN 80.0 80.0 100.0 100.0 100.0 125.0 Safety Device High/Low Pressure Switch,Anti-frost Protector,Fusible Plug,Overload Protector,Motor Overheat Protector,Automatic Temperature Sensitive Switch, Anti-phase Protector. Length MM 4200 4200 4200 3800 3800 4520 Width MM 1200 1200 1200 1900 1900 2260 Height MM 2230 2230 2230 2390 2390 2390 Net Weight Kg 2400 2500 2680 3600 3700 3850 Operating Weight Kg 2500 3660 3860 3280 3940 4030

16 Specification D Item AC-660AD AC-800AD AC-1020AD AC-1260AD AC-1400AD Cooling Capacity Kca/h 567,600 688,000 877,200 1083,600 1204,000 KW 660 800 1020 1260 1400 Total Input KW 234 274.4 367.4 471.6 508 Maximum Running current A 395 463.2 620.2 796.2 857.8 Capacity Control % 100-75-50-25-0 Power Supply 3N-50HZ-380V Charge Kg 86*2 104*2 132.5*2 163.6*2 181.8*2 Refrigerant Control Thermostatic Expansion Valve Screw Semi-hermetic Compressor Motor KW 111*2 130*2 172*2 218*2 235*2 Condenser Copper Coil With Aluminium Fine Low Noise Aluminium Blade Axial Fa Fan Air Flow M 3 /h 230000 280000 350000 440000 480000 Flow Rate M 3 /h 113.6 137.6 175.4 216.8 240.8 Evaporator Pressure Drop KPa 52 47 53 55 50 In/Out Pipe DN 125.0 150.0 150.0 150.0 200.0 Safety Device High/Low Pressure Switch,Anti-frost Protector,Fusible Plug,Overload Protector,Motor Overheat Protector,Automatic Temperature Sensitive Switch, Anti-phase Protector. Length MM 4520 8000 8000 8000 8800 Width MM 2260 2260 2260 2260 2260 Height MM 2570 2570 2570 2570 2570 Net Weight Kg 5000 5070 6920 7330 8000 Operating Weight Kg 5220 6310 7200 7630 8400

17 Part 5. After-sales service 1. Technical documents All labels on machines and lay-out drawings, Electrical diagram, User Manual, will be in English.HONGGAN should send all necessary files to the buyer since the third week since project execution. All documents in hard copies should be also shipped with machines together. 2. Arrangement for inspection, installation and testing work a. After all machines are delivered to customer s factory; Buyer is responsible for all preparation work, e.g. electricity supply, water supply, labors and cranes, etc. b. HONGGAN will prepare for visa application for their engineers, who are responsible for guide of machine installation and testing at the Buyer s factory. c. The Buyer will buy the round-trip air ticket for Engineer if visa application is approved. The buyer is also responsible to bear expenses generated, e.g. visa formalities, meals, accommodation and allowance of USD50 per day for each engineer. d. Engineer will give free training lessons to labors in buyer s factory. 3. Quantity and quality guarantee a.quantity/quality Discrepancy to destination port during transportation: In case of quality/quantity discrepancy to destination port in transportation, customer should file claim within 30 days after the arrival of the goods at port of destination. HONGGAN will be responsible for any discrepancy of the goods caused by shipping company and other transportation organization and/or post office. b.guarantee period and after-sales services: 15 months since date of bill of lading During this guarantee period, HONGGAN will provide spare parts without any charge in case of quality discrepancy caused by us. If the malfunctions are caused by your incorrect operations, HONGGAN will provide the buyer spare parts at cost price. c.long-term service: HONGGAN will charge the buyer cost price of spare parts beyond one year and provide long-term technical guide.

18 Part 6. Photos Show Air-cooled Chiller Water-cooled Chiller Air-cooled Screw Chiller Water-cooled Screw Chiller Condenser Compressor Inner Structure Standard package

19 Part 7. Process Cooling Chiller Selection Table Project Name:... Applicant Name :... 1. Preliminary Informations 1.1 of Requirements: Automotive Industry Iron and Steel Industry Food Industry Surface Treatment Plastics Technology Wine Producing Nuclear Energy Pharmaceutical Industry Textiles Electronics Laser Other 1.2 * of cooling method: Air-cooled Water-cooled 1.3 *Liquid type: Water Oil Water + Glycol 20. % other type 1.4 *Refrigerant type R407C R134a Other 1.5 *Inlet Water Temperature: or 1.6 *Outlet Water Temperature: or 1.7 *Chiller: Colling only Heat pump 1.8 *Time of cooling process Hour 1.9 *Water flow : m³/hour 1.10*Cooling capacity : KW or Kcal/h 1.11*Connection size to process inch 2. Breif description of your cooling process flow (This term is optional, if your cooling process is complex, you re necessary to give a brief description in words or by simple schematic drawing) 3. Chiller Workplace 3.1 *Workplace: Indoor Outdoor 3.2 *Operating conditions: or 3.3 Specifical Aspects: Dust Dampness Sand Cement Sawdust Salt(Sea) Other 3.4 Condenssor: Air condenser, helicoid fan Air condenser, centrifugal fan Water condenser 3.5 Water Pump: Simple Double Special requirements 3.6 Pump Pressure: 3 Bar 5 Bar Special requirements