The Corona air inlet TECHNICAL SPECIFICATIONS

Similar documents
Ventilation. The idea behind our climate systems is efficiency and advanced simplicity.

Ceiling diffusers. Type DLQL

Direct Fired Heater Model AD Specification

Conveyor and Batch Reflow Ovens

PDH & Professional Training

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

GLOBAL FINISHING SOLUTIONS

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Control Strategies and Considerations for Livestock and Other Farm Buildings

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

AGRI-AIDE Ventilation Equipment. AGRI-AIDE Ventilation Key to Unlocking...

Ventilation. Smarter for Poultry

Tunnel Axial Flow Fan

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Air flow management tutorial session. ACC Users Group 8 th Annual Conference Dallas, 4 October 2016 Sander Venema Howden Netherlands

Modular Supply Make-Up Air Unit

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

City of Duluth Festival Center 04/25

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Efficient dehumidification and air heating for free...

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Selecting the Correct Fan

Dairy Housing Ventilation Options for Free-Stall Barns H.K. House, P.Eng.

Fresh air supply systems

APC APPLICATION NOTE #119

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans

Fresh air supply systems

HYBRID PLUS2 AIRCOOL VENTILATORS

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Direct Gas-Fired Make-Up Air

JH Series Installation

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Smoke extract fan SMHA HATCH

CombiTunnel ventilation

ASHRAE JOURNAL ON REHEAT

DeLaval solutions for cooling cows

Steam Injection Humidifiers for use with steam boilers PRODUCT CATALOG

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Ceiling swirl diffusers

INSTALLATION & OPERATIONS MANUAL

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Steam Injection Humidifiers for use with steam boilers PR0DUCT CATALOG

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Axial fans The right fan for every house

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

How to Cut Chiller Energy Costs by 30%

INSTALLATION DO S AND DON TS

Considering Filtration. Austin Baker Ventilation Director Hog Slat, Inc

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Midea VFD Centrifugal Chiller Technology

Breezair RPA Series Installation Manual

CombiTunnel-Ventilation

42AM. Air heaters PRODUCT SELECTION DATA

How about Savings in Time, Money, Energy and Longer Life?

Improved Thermal Comfort & Energy Efficiency with low-pressure VAV diffusion design

How to improve air cooler vacuum steam condensers performance in the field

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Do More With Less

Indirect Gas-Fired Make-Up Air

Ventilate Your Swine Nursery Building

EVALUATION OF SWINE FACILITIES VENTILATION

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Fans: Features and Analysis

Pump technology: Improved energy efficiency in refrigeration plants. Dr. R. Krämer

Gas-fired unit heaters for indoor installation

MECHANICAL VENTILATION

b.) Technical Information:

GB Art. Nr

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

Ducted Propeller. Airflow Volume

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

VERSO Air Handling Units

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Cooker Hood User Manual

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Ceiling swirl diffusers

EC Plug Fans EC FanGrid Retrofits for High Efficiency Air Handling Units

Smoke Master SMPA Compact pressurisation system

THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER

Technical Information HXV - HRV Ventilation

commercial refrigeration products

Compact design & easy maintenance

Circuit SolverTM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS.

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

lindab we simplify construction LindabIndoorClimateSolutions Product overview Airborne Solutions

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

The computer for optimum climate in every pig house

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Energy-efficient heat source provides comfort in large rooms

PFS Single stage axial fan The axial fan for modern boiler plants

Transcription:

710

The Corona air inlet Proper distribution of air in a house for animals can be a challenging task. The ventilation system should be able to maintain a perfect climate throughout the production cycle. Therefor the functionality of the ventilation system is essential in order to maintain an airflow that at all times ensures a perfect in-house climate. The background Studies show that animals need a constant flow of temperate oxygen rich air from day one in order to exploit their full genetic potential. Studies also show that uncontrolled air entering a house via passive air inlets, quite often causes issues that affect the in-house climate. As a part of the ventilation industry we realized that there were a need for a new and better air inlet unit in order to improve in-house climate. Therefor we developed the Corona air inlet. The idea The idea behind the development of the Corona air inlet was to design a ventilation unit that could ensure a perfect in-house climate. The unit should provide a constant flow of temperate air in the house from day one, and throughout the growth period. Also the unit should be able to utilize the warm room air trapped under the roof. This because we knew that the ability to mix incoming air with room air would eliminate issues affecting the in-house climate. Also savings on heating would be possible if we could utilize the warm room air trapped under the roof construction. The task Based on studies, own observations and inputs from farmers we found that the Corona air inlet should be with a fan to actively distribute air in the house. The unit should also be able to mix incoming air with room air directly over the fan blade when needed. To get this right, we needed a turning baffle in the chimney in order to control the percentage between incoming air and room air. We knew that only this way we would be able to achieve the desired flexibility and thereby maintain optimum in-house climate. TECHNICAL SPECIFICATIONS Motor 3x230V / 3x400 V 1.6 A / 0.95 A Shaft output power 0.3 kw Volume flow 12000 m 3 /h @ 0 Pa Chimney diameter 760 / 740 mm Damper Turning Materials ABS / stainless steel

Essential elements needed The combination of a fan, carefully designed diffuser ducts, a baffle in the chimney, and the ability to mix room air with incoming air was essential elements in order to ensure the functionality we saw was needed. The fan The positioning of the fan in the diffuser is very precisely done in order to produce the right air speed and to ensure the units ability to mix room air with incoming air when needed. Therefor the fan is positioned in a short pipe section (orifice). This in order to produce pressure, air speed and eliminate tip flow vortex. Only this way the fan will be able to create the correct air speed and thereby to maintain the air flow pattern needed in the house. The turning baffle The chimney section of the Corona air inlet is equipped with a turning baffle in order to be able to precisely control the percentage between incoming air and room air. The baffle positioning motor open and close the baffle via a 0-10 volt signal from a climate controller. Depending on the baffle position in the chimney the mixing percentage between room air and incoming air vary. Thereby a very precise temperature and flow control of the air distributed in the house is possible. More about DACS ventilation

Essential elements needed The diffuser The shape of the diffuser was a study of its own. We needed the right profile of the diffuser to be able to create the right air speed during the production cycle. We ended up with nine identical ducts which size and shape is carefully calculated relative to the air velocity and the air flow pattern needed in the house. The recirculation opening To be able to mix incoming air with room air the diffuser is hanging in handles just under the chimney. This mechanism provides an opening between diffuser and chimney and it is through this recirculation opening room air pass, and mix, with cooler incoming air. The mixing percentage between room air and incoming air depends on the baffle position in the chimney. The functionality The interaction between the damper in the chimney, the fan in the diffuser and the shape of the diffuser is what makes the Corona air inlet outperform all other air inlets when it comes to air handling, air distribution and air flow uniformity. The very precise control of the air entering the house and the mixing of the air directly over the fan blade, in interaction with the baffle in the chimney, ensure a perfect inhouse climate throughout the entire production period - regardless of the external climatic conditions.

Recirculation Air entering the house with baffle operating between 0% and 30% opening vary between 0 and 2900 cubic meter/hour. The constant supply of incoming air to the house ensures plenty of oxygen to the animals. damper closed During the first weeks of production the Corona air inlet run with only slightly open baffle (5% - 25%). During this period the Corona air inlet mix a minor portion of incoming air with warm room air, in order to supply oxygen to the animals and to ensure the air is properly tempered relative the desired temperature in the stable. The utilization of the warm room air and the constant flow of this warm room air during recirculation mode ensures uniform temperatures throughout the house and a cut in heating cost by 50% compared to other systems. The constant mix of warm room air with air entering the house bring a constant flow of temperate and oxygen rich air to the animals. This ensure a perfect inhouse climate no matter outside weather conditions.

Mixing mixing Air entering the house with baffle operating between 30% and 80% opening vary between 2900 and 11000 cubic meter/hour. This brings plenty of oxygen to the animals and increase the air exchange in the house. During the growth period and/or if outside temperatures increase heat and humidity from the house accelerate the ventilation system in order to keep setpoint on temperature and humidity. The baffle in the chimney gradually open more (30% - 80%) and the Corona air inlet introduce more incoming air to the house but still mix in a small percentage of room air to ensure that only temperate air leave the unit. The mix of room air with incoming air ensure that only temperate air leave the unit. Still the utilization of room air cut heating cost by 50% compared to other systems. The mixing of incoming air with room air bring a constant flow of temperate and oxygen rich air to the animals. This flow of temperate air ensures a perfect inhouse climate no matter outside weather conditions.

Full flow damper open Air entering the house with baffle operating between 80% and 100% vary between 11000 and 12500 cubic meter/hour. This bring plenty of oxygen to the animals and increase the air exchange in the house. During the last weeks of production, or when outside temperatures it close to set-point the baffle in the chimney gradually open more (80% - 100%) to increase air flow in the house in order to expel moisture and heat from the animals but also to cool the animals. At this stage very little mixing is needed, but often during night the baffle will fall back and mixing will be maintained. The mixing of room air with incoming air is at a minimum and will only slightly affect the temperature leaving the unit. The constant flow of cool oxygen rich air ensure that the animals are very well ventilated and therefor thrive during this period.

Basic installation rules The Corona air inlet is a very versatile unit and will work well in all types of buildings if basic rules are followed. As long as the unit is positioned so that the air distributed from it can be spread evenly in the house the system will be able to establish the air flow pattern in the house needed to maintain a stable climate in the house. The Corona air inlet will work independently from height, width and length of house as long as the below references are followed. 6-16m 16-20m In houses 6-12 meter in width, Corona air inlets should be positioned in one row. Corona air inlets should be operated via variable frequency drives (VFD) in order to ensure the air speed and air flow pattern is as needed in the house. All Corona air inlets should be in operation from day one. In houses 12-16 meter in width Corona air inlets should be operated either via variable frequency drives (VFD), or in groups (via on/off signal) in order to ensure the air speed and air flow pattern is as needed in the house. In houses 16-20 meter in width the Corona air inlets must be positioned offset in relation to the roof rack. This in order to maintain the air flow pattern needed in the house. Corona air inlets should be operated either via variable frequency drives (VFD), or in groups (via on/off signal) in order to ensure the air speed and air flow pattern is as needed in the house. 6-16m 16-20m

Need to know The fan in the diffuser can be either on/off operated or run via variable frequency drives. The fan should never be running at speeds less than 70% of maximum and at this speed with no more than 10% opening of the baffle. At 100% speed the baffle should be 100% open. This to ensure the best possible air distribution and best possible mixing of incoming air with room air when needed. 20-30m 30-48m In houses from 20-30 meter in width the Corona air inlets must be positioned in two rows. Also here the positioning of the Corona air inlet is closely related to the air flow pattern needed. Corona air inlets should be operated either via variable frequency drives (VFD), or in groups (via on/off signal) in order to ensure the air speed and air flow pattern is as needed in the house.. In houses from 32-48 meter in width the Corona air inlet must be positioned in three rows. The central row will ensure that air will be distributed correctly in order to maintain the air flow pattern. Corona air inlets should be operated either via variable frequency drives (VFD), or in groups (via on/off signal) in order to ensure the air speed and air flow pattern is as needed in the house. 20-30m 30-48m

General guideline for positioning The positioning of the Corona air inlet differs depending on if the Corona air inlet is speed controlled or on/off controlled, but also depending on if animals are kept on floors or kept in cages. Therefor the below is a general guideline. If needed we will always be able to help you with the positioning of the Corona air inlet. House with pitched ceiling Speed controlled: If the Corona air inlet is speed controlled then H+D should be nothing less than 6 meter and nothing more than 12 meter. R > 1.35m H D On/off controlled: If the Corona air inlet is on/off controlled then H+D should be nothing less than 9 meter and nothing more than 12 meter. R should be nothing less than 1,35 meter. This in order to have the baffle positioning motor in the room. House with flat inner ceiling Speed controlled: If the Corona air inlet is speed controlled then H+D should be nothing less than 6 meter and nothing more than 12 meter. R > 0.9m H D On/off controlled: If the Corona air inlet is on/off controlled then H+D should be nothing less than 9 meter and nothing more than 12 meter. R should be nothing less than 0.9 meter. This in order to ensure proper recirculation of the warm room air trapped under the roof space. G D Top view Speed controlled: If the Corona air inlet is speed controlled then G+H should be nothing less than 6 meter and nothing more than 12 meter. On/off controlled: If the Corona air inlet is on/off controlled then G+D should be nothing less than 9 meter and nothing more than 12 meter.

Exhaust fans We offer three types of exhaust units that all can work in conjunction with the Corona Air inlet. Two roof mounted units and a wall mount fan. Roof mounted exhaust fan Wall mount fan The HE740 exhaust unit is made of expanded ABS plastics and stainless steel. With a specific consumption of 25,5 W/1000 m³/hour at full flow it is the most efficient roof mount fan available. The HE740 come in two versions. One with turning baffle in the chimney and one with butterfly valve on top of the chimney. The one with turning baffle can be operated via variable frequency drive (VFD) or via on/off signal where the one with butterfly baffle should be operated via an on/off signal. TECHNICAL SPECIFICATIONS Motor 3x230V / 3x400 V 1.6 A / 0.95 A Shaft output power 0.3 kw Volume flow 17471 m 3 /h @ 0 Pa Specific consumption 25.5W / 1000m 3 /h Fan RPM 945-960 @ 50 Hz Materials ABS / stainless steel The MagFan is a high capacity, ultra-efficient direct drive wall mount fan. With a capacity of up to 80.000m³/hour and a specific consumption of 9,72 W/ 1000m³/hour at full flow it is the most powerful yet most efficient wall mount fan available. MagFan come with a dedicated variable frequency drive (VFD). The unit can be applied with two different shutter system. TECHNICAL SPECIFICATIONS Water proof speed drive Drive cos (phi) / power factor at full load: 0.99 In-built drive and motor protection Permanent Magnet Synchronous 3-phase Output (continuous duty): Motor 1.2kW @ 660RPM / 2.2kW @ 750RPM Insulation class F, 170 C magnets In-built double Klixon thermal protection Single phase, 100-265VAC, 50/60Hz Power supply Three phase, 360-440VAC, 50/60Hz Volume flow /Specific consumption Please refer to separate performance charts and technical specifications for MagFan

Innovative solutions for livestock production DACS is a family-owned company with more than 30 years experience in developing, producing and servicing ventilation and control systems for livestock production. We have used our comprehensive knowledge on both livestock production and ventilation in the development of among others our award winning wall fan, MagFan. Our ventilation system is simply the most energy efficient system you can get on the market. We run tests in our own wind tunnel, and we develop our products in close cooperation with farmers and the best researchers in the field. Our overall focus is on optimum animal welfare and on maximum energy efficiency. DACS brings you: Energy efficient ventilation systems Total production and climate control Improved animal welfare F:\FM_DOC\MANUALS\Newsletters\Corona.fm (C) DACS - RW 23 January 2018 DACS a/s on Vimeo Falkevej 18, DK8766 Nørre Snede, Denmark phone +45 75 77 19 22 www.dacs.dk mail@dacs.dk