Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Similar documents
Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Quick Start Manual July pointek CLS100

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Continuous level measurement Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement Ultrasonic transmitters

POINTEK CLS 200 OINTEK CLS 200 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

Temperature Measurement Transmitters for field mounting

Flow Measurement SITRANS F C

Process Protection. 6/2 Product overview. 6/3 Acoustic and Motion sensing. Acoustic sensors for pump monitoring 6/5 SITRANS DA400

M-Switch Float Operated Liquid Level Switch

POINTEK CLS 300 OINTEK CLS 300 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

OilSET-1000 (12 VDC)

Process Protection. 6/2 Overview. 6/3 Acoustic and motion sensing. Acoustic sensors for pump monitoring 6/5 SITRANS DA400 acoustic diagnostic unit

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content

SITRANS F M MAG 3100 P:

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Technical Data. General specifications. Rated operating distance s n 5 mm

Rosemount 3100 Series Ultrasonic Level Transmitters

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Specifications - Installation and Operating Instructions 2X 1/2 NPT OR M20 ELECTRICAL ENTRY. 3/4 NPT or 3/4 BSPT 5/8 [15.88]

Inductive slot sensor

SET-2000 Hi Level/Oil

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

POINTEK ULS 200 ULTRASONIC LEVEL SWITCH. Instruction Manual August 2002

Rosemount 3490 Series

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Technical Data. Dimensions

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Enraf Servo Gauge 854 XTG

Rosemount 3100 Series Ultrasonic Level Transmitters

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Cable Glands DB Series: Drain, Breather Valves and Unions

Hazardous Area Zirconia Oxygen Systems

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Safety instructions VEGAPULS 64

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

RF Admittance Technology FACTS

Mobrey MCU900 Series Universal Control Unit

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

U5700 Submersible Liquid Level Pressure Transducer

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Technical Data. Dimensions

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

INSTRUCTION & SERVICE MANUAL

Introduction to Flow Switch

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

FAHM Co. Temperature Transmitter PTT74 Series

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Operating Instructions Edition 02/2007

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Enraf Servo Gauge 854 ATG

M5800 Pressure Transducer with Rotatable Display

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Certificate of Compliance

Ultrasonic Point Level Switches

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

INTRODUCTION / TABLE OF CONTENTS

ABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)

Dräger Polytron 7000 Fixed gas detector

LEVEL MONITOR WITH ANALOG AND HIGH / LOW ALARM OUTPUTS. DATASHEET F170 - LEVEL MONITOR

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Inductive Conductivity

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Rosemount 2100 Series

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Rosemount 752 Fieldbus Remote Indicator

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Centro-Matic Automated Lubrication Systems System Controls

BDI-FLX B URST SY STE M BENEFITS BDI-FLX AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

SET Installation and Operating Instructions. Level switch for one sensor

North American Cable Glands

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Transcription:

Level Measurement Siemens AG 2012 Overview Configuration Installation Standpipes 0 (2) 20 (0.79) max. is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits Easy installation with verification by built-in LED Low maintenance with no moving parts Sensitivity adjustment Integrated cable or PBT enclosure versions available Intrinsically Safe, Dust Ignition Proof, and General Purpose options available Application s short insertion length of 100 mm (4 inch) and versatility in various applications and in vessels or pipes makes it a good replacement for traditional capacitance sensors. Its advanced tip-sensing technology provides accurate, repeatable switchpoint performance. The PPS (Polyphenylene sulfide) probe [optional PVDF (Polyvinylidene Fluoride)] is chemically resistant with an effective process operating temperature range from -30 to +100 C (-22 to +212 F) (7ML01), and -10 to +100 C (+14 to +212 F) (7ML610). The fully potted design ensures reliability in a vibrating environment such as agitated tanks up to 4 g. When used with a SensGuard protection cover, the CLS100 is protected from shearing, impact, and abrasion in tough primary processes. The is available in three versions. The integral cable version has a stainless steel process connection and probe options of PPS or PVDF. The fully synthetic version has a thermoplastic polyester enclosure with a PPS process connection combined with a PPS probe. The standard enclosure version has a thermoplastic polyester enclosure with a stainless steel process connection in combination with a PPS or PVDF probe. Key Applications: liquids, slurries, powders, granules, food and pharmaceuticals, chemicals, hazardous areas Wall Restriction 0 (2) 0 (2) min. installation, dimensions in mm (inch) /10 Siemens FI 01 2012

Siemens AG 2012 Level Measurement Technical specifications Stainless steel Fully synthetic process connection process connection (integral cable or (enclosure version enclosure version) only) (7ML610) (7ML01) Mode of operation Measuring principle Inverse frequency Inverse frequency shift capacitive level shift capacitive level detection detection Input Measured variable Change in picofarad Change in picofarad (pf) (pf) Output Output signal Alarm output 4... 20/20... 4 ma 4... 20/20... 4 ma 2-wire loop 2-wire loop Switch output 1) Solid-state: 30 V DC/ Max. switching 30 V AC, max. 82 ma voltage: 60 V DC/ 30 V AC Max. switching current: 1 A Fail-safe mode Min. or max. Min. or max. Accuracy Repeatability 2 mm (0.08 inch) 2 mm (0.08 inch) Rated operating conditions 2) Installation conditions Location Indoor/outdoor Indoor/outdoor Ambient conditions Ambient temperature -30... +8 C (-22... +18 F) -10... +8 C (+14... +18 F) Installation category I I Pollution degree 4 4 Medium conditions Relative dielectric contant ε r Min. 1. Min. 1. Process temperature -30... +100 C (-22... +212 F) -10... +100 C (+14... +212 F) Pressure (vessel) -1... +10 bar g (-14.6... +146 psi g), nominal 2) -1... +10 bar g (-14.6... +146 psi g), nominal Degree of protection - Enclosure version IP68/Type 4/NEMA 4 IP68/Type 4/NEMA 4 - Integral cable version IP6/Type 4/NEMA 4 Not applicable Cable inlet ½" NPT (M20x1. optional) ½" NPT (M20x1. optional) Design Enclosure/Integral Fully synthetic version cable version Material Body (Enclosure version) Thermoplastic polyester Thermoplastic polyester Lid (Enclosure version) Integrated cable body (Integral cable version) Sensor length (nominal) Transparent thermoplastic polycarbonate (PC) 316L stainless steel Transparent thermoplastic polycarbonate (PC) Not applicable 100 mm (4 inch) 100 mm (4 inch) material of probe/ wetted parts 3) Connection (Enclosure version) Connection (Integral cable version) Stainless steel process connection (integral cable or enclosure version) (7ML01) Connection: 316L stainless steel; Process seal: FKM (optional FFKM); Sensor: PPS (optional PVDF) 4) Internal -point terminal block, ½" NPT wiring entrance, M20x1. optional 4 conductors, 1 m (3.3 ft), 0. mm² (22 AWG), shielded, polyester jacket ¾" NPT [(Taper), ANSI/ASME B1.20.1] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] Fully synthetic process connection (enclosure version only) (7ML610) PPS process connection and PPS sensor (Uni-Construction) Removable internal -point terminal block, ½" NPT wiring entrance, M20 x 1. optional Not applicable ¾" NPT [(Taper), ANSI/ASME B1.20.1] R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] Power supply Standard 12... 33 V DC 12... 33 V DC Intrinsically Safe 10... 30 V DC Not applicable (Intrinsically Safe barrier required) Certificates and approvals General: CE, CSA, FM, C-TICK Marine: Lloyds Register of Shipping, categories ENV1, ENV2, and ENV Dust Ignition Proof (barrier required): CSA/FM Class II and III, Div. 1, Groups E, F, G T4 Intrinsically Safe (barrier required): CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G T4 ATEX II 1 GD 1/2GD EEx ia IIC T4 to T6 T107 C Overfill protection: WHG (Germany) General: CSA, FM 1) When synthetic process connection version (7ML610) is used in wet locations, switching voltage of the relay is limited to 3 V DC/16 V AC. 2) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /14. 3) For Caustic Materials please contact ceg.smpi@siemens.com http://www.siemens.com/automation/support-request for alternative O Rings 4) When FFKM O-ring (Option A22) is selected, process temperature is restricted to -20 C (-4 F). Siemens FI 01 2012 /11

Level Measurement Siemens AG 2012, stainless steel process C) 7ML01- connection 0 7 7 7 7 Compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam ¾" NPT [(Taper), ANSI/ASME B1.20.1] A R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] J Approvals General Purpose: CE, CSA, FM, C-TICK CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G T4; ATEX II 1 GD 1/2GD EEx ia IIC T4 to T6 T107 C 1) CSA/FM Class II and III, Div. 1, Groups E, F, G 1) Device version Integral cable version (PPS probe) 1 Enclosure version (PPS probe), ½" NPT cable inlet 3 Integral cable version with PVDF probe body Enclosure version with PVDF probe body 6 (½" NPT cable inlet) Enclosure version (PPS probe), M20x1. cable inlet 7 Enclosure version with PVDF probe body, 8 M20x1. cable inlet WHG approval, German overfill protection Not required 0 Required 1 1) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection C) Subject to export regulations AL: N, ECCN: EAR99. Further designs Please add "-Z" to and specify Order code(s). Acrylic coated, stainless steel tag [13 x 4 mm (0. x 1.7 inch)]: Measuring-point number/identification (max. 20 characters) specify in plain text FFKM seal O-ring 1) Inspection Certificate Type 3.1 per EN 10204 Operating Instructions Quick start manual, multi-language Note: due to ATEX regulations one Quick start manual is included with every product. This device is shipped with the Siemens Milltronics manual CD containing ATEX Quick Starts and Operating Instructions. Optional equipment Sensguard, ¾" NPT (PPS) Sensguard, R 1" (BSPT) (PPS) Siemens Intrinsically Safe Barrier (DC powered), ATEX II 1 G EEx ia ½" NPT cable gland, nickel plated brass, fits cable diameter 6... 12 mm (0.24... 0.47 inch) -40... +100 C (-40... +212 F), IP68 (General Purpose) M20x1. cable gland, PA polyamide, ATEX II 2G EEx e II, fits cable diameter 7... 12 mm (0.28... 0.47 inch), -20... +70 C (-4... +18 F), IP68 (General Purpose) A C G Order code Y17 A22 C12 7ML1998-QJ82 7ML1830-1DL 7ML1830-1DM 7NG4124-0AA00 7ML1830-1JA 7ML1830-1JC, PPS process connection Compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam (PPS) ¾" NPT [(Taper), ANSI/ASME B1.20.1] (PPS probe body) R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] (PPS probe body) Approvals General Purpose: CSA, FM Versions/Options Enclosure version, PPS process connection, ½" NPT cable inlet Enclosure version, PPS process connection, M20x1. Further designs Please add "-Z" to and specify Order code(s). Acrylic coated, stainless steel tag [13 x 4 mm (0. x 1.7 inch)]: Measuring-point number/identification (max. 20 characters) specify in plain text FFKM seal O-ring 1) Inspection Certificate Type 3.1 per EN 10204 Operating Instructions Quick start manual, multi-language Note: due to ATEX regulations one Quick start manual is included with every product. This device is shipped with the Siemens Milltronics manual CD containing ATEX Quick Starts and Operating Instructions. Optional equipment Sensguard, ¾" NPT (PPS) Sensguard, R 1" (BSPT) (PPS) 1) See Temperature restriction on page /14 C) 7ML610-0 7 7 0 A B D 1 2 Order code Y17 A22 C12 7ML1998-QJ82 7ML1830-1DL 7ML1830-1DM 1) See Temperature restriction on page /14 /12 Siemens FI 01 2012

Siemens AG 2012 Level Measurement Options Optional Sensguard internal thread ¾" NPT 32 (1.26) process connection ¾" NPT process connection R 1" (BSPT) 91 (3.6) 70 (2.7) 91 (3.6) 32 (1.26) 70 (2.7) Optional Sensguard, dimensions in mm (inch) Siemens FI 01 2012 /13

Level Measurement Characteristic curves Siemens AG 2012 Pressure/Temperature Curve CLS100 Threaded Process Connections (7ML01) Permitted Operating Pressures P 30 bar (43 psi) 20 bar (290 psi) atmospheric -1 bar (-14. psi) -10 ºC (-238 ºF) -100 ºC (-148 ºF) 10 bar (14 psi) -0 ºC (-8 ºF) Example: Permitted operating pressure = 10 bar (14 psi) at 7 C -22 ºF 14 ºF (-30 ºC) (-10 ºC) -29 ºC (-20 ºF) 100 ºF (38 ºC) 200 ºF (93 ºC) 0 ºC RT 0 ºC 100 ºC (32 ºF) (122 ºF) (212 ºF) 300 ºF (149 ºC) 10 ºC (302 ºF) 400 ºF (204 ºC) 200 ºC (392 ºF) Permitted Operating Temperature T Process Pressure/Temperature derating curves Dimensional drawings Integral cable version Enclosure version 80 (3.2) Ground post Power LED (green) Sensitivity trimpot Cable Ø (0.2) Trimpot cap 36 (1.4) nominal* Cable relief Output status LED (red) Sensor status LED (yellow) Power LED (green) Sensitivity trimpot Sensor status LED (yellow) Output status LED (red) 1 2 3 4 6 (2.6) Cable inlet ½" NPT (optional M20x1.) Terminal block ground lug 120 (4.7) 0 (2.0) 98 (3.9) nominal 98 (3.9) nominal 72. (2.9) 120 (4.7) 204 (8.0) *Some G thread configurations deviate from this size. dimensions, dimensions in mm (inch) /14 Siemens FI 01 2012

Siemens AG 2012 Level Measurement Schematics Integral Cable Version - Non Intrinsically Safe only LOW/HIGH Alarm black red Polarity as required for desired operation 12... 33 V DC 4/20 ma Loop Alarm Rmax = Vsupply - 10 V 20 ma Solid State Switch Version black red black V supply 12... 33 V DC Solid state switch, 30 V DC/AC (peak) 82 ma (max) Enclosure and Fully Synthetic Version 1 2 3 4 red Terminal operations macurrent loop (+V or -V) macurrent loop (+V or -V) ground solid state switch/relay* solid state switch/relay* V supply 12... 33 V DC Cable equivalent red wire black wire cable shield wire wire Note: * switch/relay normally open in unpowered state * relay not available on IS version (7ML01) When driving an inductive load (for example, an external relay), a protection diode must be connected in the correct polarity to prevent possible switch damage due to inductive spikes generated by switching the inductor (please refer to instruction manual). Intrinsically Safe Models - please follow local regulations and area classifications; refer to instruction manual for more details. connections Siemens FI 01 2012 /1