Why Hart XL Aspirating Smoke Detection?

Similar documents
HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

EARLIEST SMOKE DETECTION WITH MAXIMUM FLEXIBILITY

Buys Time. Aspirating Smoke Detection

Buys Time. Aspirating Smoke Detection

The World's No. 1 Brand of Air-sampling Smoke Detector

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

FAAST. Fire Alarm Aspirating Sensing Technology

The World's No. 1 Brand of Aspirating Smoke Detector

The World s No. 1 Brand of Aspirating Smoke Detection

The World's No. 1 Brand of Aspirating Smoke Detector

Flexible Air-sampling Smoke Detection

Intelligent Earliest Warning Aspirating Fire Detector

Aspir A ation spir P R O D U C T S

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST PRODUCT RANGE Aspirating Smoke Detection

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

Aspirating Smoke Detection

Fire control panel detect 3004 plus and accessories

Aspirated Smoke Detectors

FAAST. Fire Alarm Aspiration Sensing Technology

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

SALES SUPPORT DOCUMENT

The EN54 Part 2 & 4 Fire System

LaserFOCUS VLF-250 Engineering Specification

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Different types of Fire Alarm System

Conventional & Twin-wire Fire System

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

ACP10 & ACP50 Security Systems

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

System 800 Addressable Fire Detection & Alarm System

Intelligent Single Loop Fire Alarm Control Panel

Aspiration Systems for Smoke Detection

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

HRX Technical Manual. Version 1.2

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

The EN54 Part 2, 4 and 13 Fire System

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

intelligent fire alarm ID60series panels

On the job around the clock 24/7: Fire detection systems

Intelligent addressable fire alarm control panel

Excel-EN Conventional Fire Control Panel

user manual Document No , Revision 03 November 2015

Open-area Smoke Imaging Detection (OSID)

ELECTRONIC SOUNDER STROBE Model : AVD-C407

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Consultant Specification AGILE Wireless Fire Detection System

Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Honeywell Air Sampling Devices Data Sheet

ZXSe Range Data Sheet

GE Security. air sampling pipe networks installation and design manual

ID2000. intelligent fire alarm panel

Aspiration Detection.

Fire Detection Systems Product Catalogue (Version )

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

Intelligent Security & Fire Ltd

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

DS7400Xi Addressable Control/ Communicator

INTELLIGENT FIRE ALARM CONTROL PANEL

Vigilant MX4428 Fire Alarm System

ID3000 intelligent. fire alarm panel

Solution F2. Fire Alarm Control Panels one step ahead.

Installation, Operating and Maintenance Manual

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Control Panels and Fire Detection Equipment

Multi-Gas-Controller MGC2

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

ID50series. intelligent fire alarm panels

Fire and Smoke Control Systems

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

VESDA VLP. Engineering Specification

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

End To End Optical Beam Smoke Detector. Additional Information

intelligent solutions

GAS EXTINGUISHING SYSTEMS COMPACT EXTINGUISHING SYSTEMS. OneU. Fire Protection Systems for 19" Racks

Aspirating Smoke Detection for Large Area Coverage Applications

For Complete Fire and Gas Solutions

Advanced FireAlarm Panel 1-4Loop

ID3000 intelligent. fire alarm panel

FIRElux Emergency Lighting

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

VESDA ASPIRATING SMOKE DETECTION INDUSTRY GUIDE SUBSTATIONS

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

SUPREMATouch. Modular Fire & Gas Detection System

General Routing Interface

FIRERAY 5000 range USER GUIDE

Transcription:

HART XL

Why Hart XL Aspirating Smoke Detection? Earliest detection to enable business continuity Extra time is required for safe evacuation Unnecessary suppression release must be avoided Smoke is difficult to detect Environmentally challenging areas Aesthetics & concealed detection are important Maintenance access is limited

Earliest Detection to Enable Business Continuity Critical processes that cannot incur any business disruption Telecommunications facilities Computer rooms Banking operations Production facilities Internet Service Providers

INTENSITY 1st Stage Hart XL provides the earliest possible warning - buying time Incipient Visible smoke 2nd Stage Flames 3rd Stage Heat Final Stage TIME PRE-ALARM 1 PRE-ALARM 2 Alarm 1 Alarm 2

Extra Time is Required for Controlled Evacuation Environments where rapid exit can be impeded Underground Stations Theatres Public buildings Airports

Unnecessary Suppression Release Must be Avoided Early warning gives time to investigate to avoid unnecessary suppression release Telecommunication facilities EDP facilities Computer rooms Electrical sub-stations

Smoke is Difficult to Detect Environments with high ceilings, high air flows or vast open areas provide unique characteristics Clean rooms Warehouses Aircraft hangers Computer rooms Atria

Warehouse and Atrium Protection Hart XL detector Horizontal and vertical sampling pipes Hart XL detector S M O K E Stratified smoke layer Area open to main atrium

Environmentally Challenging Areas Aggressive environments with high levels of pollution or extreme temperature conditions can be protected reliably with acceptable maintenance levels Cold Stores Production areas Paper mills Underground tunnels Mines

Aesthetics are Important & Replacement Impossible Interiors that must not be spoilt by unsightly conventional detectors Hart XL can be installed unobtrusively Cathedrals Stately Homes Museums Art Galleries

Maintenance Access is Limited Hart XL can be located at an accessible location while the sampling pipework makes its way to the restricted area Warehouses Production machinery Prisons Restricted areas EMC Controlled areas Hospitals

HART XL Technical Features

Hart XL Range Detector Enclosure Display Module Self Contained Power Supply LaserNet (Direct & Network) SNIFF Version 3

Modular System Display Detector Power Supply

Detector Inlet Detector Termination Board Fan Outlet

Features Laser Particle Counter User Selectable Sensitivity Range(s) Digital Communications 4 Levels of Alarm Monitors Air Flow Modular in Design

Features (Cont.) Historical Smoke & Event Log Autosetup Function Alarm Level Selection Multiple Status Indications Programmable Delays Day/Night Setting Network Capabilities

Specification IP31 Weight 3.4 kg (7.5 lbs.) Polycarbonate Light Grey Dimensions - 320 by 228 by 108 mm Input Voltage 18-30 V DC Input Current 315 ma (With Display 445 ma) Operating Temperature - 0 to 52 Humidity - 10 to 95% Non Condensing

Standard Detector Applications S ensitivity R anges R ecom m ended A pplications S m oking 1 % /Ft % /m 0.30-0.076 1.0-0.25 U nderground E lectric Y es 0.24-0.048 0.8-0.16 R ailw ays, S em i D irty 0.18-0.024 0.6-0.08 M anufacturing A reas 0.16-0.016 0.55-0.055 0.15-0.015 0.50-0.05 0.13-0.013 0.45-0.045 0.12-0.012 0.4-0.04 M anufacturing A reas Y es 0.10-0.010 0.35-0.035 0.09-0.009 0.3-0.03 0.076-0.0076 0.25-0.025 0.06-0.006 0.2-0.02 O ffice A reas, M useum s, No 0.045-0.0030 0.15-0.01 C lean M anufacturing A re as 0.03-0.0015 0.1-0.005 Low G rade C lean R oom No 0.015-0.00076 0.05-0.0025

Ultra Detector Applications S ensitivity R anges % /Ft % /m R ecom m ended A pplications 0.030-0.0076 0.10-0.025 Low G rade C lean R oom 0.024-0.0048 0.08-0.016 0.018-0.0024 0.06-0.008 0.016-0.0016 0.055-0.0055 0.015-0.0015 0.050-0.005 H igh G rade C lean R oom 0.013-0.0013 0.045-0.0045 0.012-0.0012 0.04-0.004 0.010-0.0010 0.035-0.0035 0.009-0.0009 0.03-0.003 0.0076-0.00076 0.025-0.0025 U ltra G rade C lean R oom 0.006-0.0006 0.02-0.002 0.0045-0.00030 0.015-0.001 0.0038-0.00022 0.0125-0.00075 0.0030-0.00015 0.01-0.0005

Servicing & Maintenance Easy and quick to service and maintain Reduced downtime Lower servicing cost Lower spares holding Reduced cost of ownership

Display Module

Hart XL Display Control Unit Large LCD Display Clear Information Three Colour Status LED Status Normal Indication Time and Date Cursor Menu Control Password Access for Further Information

Hart XL Display Control Unit Alarm condition Ten bar graph scale Location identifier Fault type identified through password access

Features Local or Remote Mount Option Mono Back Lit Graphical LCD Displays Real Time Information 5 Control Keys Audible Sounder Indication Status LED Indication

Specifications Weight 0.5 kg (1.1 lbs.) Polycarbonate Light Grey Dimensions - 122 by 145 by 38 mm RS485 Communications - 1 km (max) Input Voltage 18-30 V DC Input Current 130 ma (Back lit on) Operating Temperature - 0 to 52 Humidity - 10 to 95% Non Condensing

Self Contained Power Supply

Features 1 amp Power Supply 90 to 260 V AC Input 28.75 Volt @ 1 amp Output Space for 2 off 12volt 2.0 Ah Batteries Blends in with Enclosure Design Ease of Installation

Specification Weight 3.1 kg (7 lbs.) - Without Batteries Polycarbonate Light Grey Dimensions - 320 by 112 by 108 mm Input Voltage 90 to 260 V AC Operating Temperature - 0 to 52 Humidity - 10 to 95% Non Condensing

LaserNet Software Direct or Network Mode Option Windows Compatible (95,98, 2000 & NT) Used to Configure Detector Used to Commission System Used to Monitor System Password Protected Entry View Event & Smoke History

Programming and Diagnostics Direct connection to PC for Programming and Downloading using LaserNet Software. No programmers or interfaces are required

LaserNet Features Programming Options Diagnostics & Monitoring Fixed or automatically set sensitivity Programmable relays Latching or non latching alarms Two or Four levels of Alarm Delay timers Day/Night option Download history & event log Full fault analysis Dial in & dial out via modem monitoring (Network) Intelligent interface module (IIM) common alarm & fault relay outputs

SNIFF Software System Design Software Windows Compatible (95,98, 2000 & NT) Sample Calculation & Optimisation Tool Flexible Design Criteria Isometric Design Layout Feature Design Reports (Including Parts Lists) Allows 100 sample points over 40 Segments

New Updated SNIFF System Design Software Windows compatible Easy operation and clear displays Isometric drawings from several angles

New Updated SNIFF System Design Software Benefits High quality print out with isometric drawings & calculations Optimised sample hole sizing Compatible with current PC operating systems