Air-Cooled Condensing Units with Compact Screw Compressors

Similar documents
Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Condensing Units w/ Screw Compressors

horizontal air discharge outdoor discus condensing unit

Air-Cooled Condensing Units with Bitzer Compressors

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Kramersaver Air Cooled Condensing Units

3-22 HP CONDENSING UNITS Technical Guide

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Advance Release September 2009

30GN FLOTRONIC II AIR-COOLED CHILLERS

Air-Cooled Condensers

30GT FLOTRONIC AIR-COOLED CHILLERS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

500 EX Fusion Compressor Series

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

MAC N-407 Air-Cooled Chiller

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

Center Mount Unit Coolers

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

MACH N-407 Heat Pump Air-Cooled Chiller

Call us today! (800)

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

C13-Series Engineering Guide

Call us today! (800)

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Call us today! (800)

Commercial High-Efficiency Condensing Units

VertiCool Aurora Engineering Guide

Low Flow Unit Coolers

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Commercial High-Efficiency Condensing Units

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

WCH5**4. Product Specifications

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

TECHNICAL SPECIFICATIONS

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

CoolSpot Engineering Guide

PAJ3. Product Specifications

VariCool VAV Engineering Guide

Water-Cooled Self-Contained Units

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

R4H4. Product Specifications

T H I N K I N S I D E T H E B o x

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant.

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

MAC-120HE-03 Air-Cooled Chiller

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Kirby Commander Condensing Unit

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

N4H4. Product Specifications

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

technical guide Water-Cooled Self-Contained Units

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

R4H4. Product Specifications

TECHNICAL SPECIFICATIONS

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

Copeland Scroll Outdoor Refrigeration Unit

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

.2 Section Waste Management and Disposal.

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Air-Cooled Condensers

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

Low Profile Unit Coolers

Liebert CSU3000 Chiller

Installation, Start-Up and Service Instructions

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

RGE 13 A T - 1 A

KCS-Line Air Cooled Condensers

Transcription:

LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV

Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor... 5 Condenser Features... 6 Unit Features and Options... 7 Performance Data... 8 Medium Temperature... 8-9 R-404A/R-507... 8 R-407C... 9 High Temperature... 10 R-407C... 10 Physical Data... 11 Dimensional Drawings... 11 Electrical Data... 12-13 Nomenclature S S V OOOB M 6 D Number of Circuits Airflow Horsepower Temp. Range Refrigerant Voltage Style Type S = Single S = Screw V= Vertical 050B 50 M = Medium 6 = R-404A, D = 460/3/60 D = Dual 060B 60 H = High R-507 E = 575/3/60 070B 70 7 = R-407c 080B 80 090B 90 100B - 100 110B - 110 125B - 125 140B - 140 2

THE RIGHT CHOICE FOR LARGE COOLING APPLICATIONS The screw compressor condensing unit is an important addition to the Heatcraft air-cooled condensing unit product family, featuring innovative compact screw compressors and advanced microprocessor controls. The unit is designed to provide increased system reliability, reduced installation and operation costs, as well as, improved product integrity in commercial and industrial refrigeration applications. Increased Reliability The Heatcraft screw compressor condensing unit is a reliable and rugged system, designed for the commercial and industrial refrigeration markets. Compact screw compressors have fewer moving parts than reciprocating compressors, resulting in improved durability. Additionally, a semi-hermetic motor design eliminates shaft seal and coupling concerns, while an integral oil system provides improved lubrication performance. The screw compressors utilize slide valve unloading which increases motor life through unloaded compressor starting. The new screw condensing units are factory equipped with an advanced microprocessor control system. This control system constantly monitors and adapts by modifying multiple parameters to guarantee safe and reliable system performance. Finally, all screw compressor condensing units come standard with a floating tube condenser coil design, minimizing the potential for refrigerant leaks. Reduced Costs of Ownership Screw compressor condensing units allow owners and operators to reduce both their installation and operating costs. Screw compressor condensing units yield more capacity per compressor than traditional reciprocating compressor condensing units. The result is a reduced number of units on large projects and subsequent savings of time and cost during installation and commissioning. Built-in features such as soft starting, slide valve unloading, and digital controls make Heatcraft screw compressor condensing units the optimum choice for maximum performance with minimal operating costs. Improved Product Integrity With advanced digital controls and variable capacity capability, the screw compressor condensing units have the capability to maintain more precise temperature control and stable product environment. Minimizing temperature fluctuations results in maximum product integrity; all while maintaining overall system performance. Screw compressor condensing units are the right choice and the perfect match for large, mission critical cooling applications. 3

COMPACT SCREW COMPRESSORS : FEATURES AND BENEFITS Compact Screw s The Bitzer CSH compact screw compressor is the result of continuous development for a simplified, space and energy efficient semi-hermetic screw compressor. Using state of the art technology, this screw compressor is not only smooth running, quiet, and efficient; but also meets the same stringent performance and reliability benchmarks that have set the industry standard. Robust Design The compact screw compressors feature a newly developed efficient twin rotor geometry. The rotors are precisely located at both ends by bearings that prevent radial and axial movement reducing unit vibration. Rotors and housing are machined for tight tolerances allowing optimum efficiency while preventing wear. s are constructed with a double wall rotor casing for reduced sound transmission. Rotor and casing design, in conjunction with oversized oil supply chambers, result in a significantly more robust compressor. Optimized Oil Management The compact screw compressors are designed with an integral three-stage oil separator and a 10-micron oil filter. Oil system also includes an oil level control, oil level sight glass, crankcase oil heater, and an oil service valve. The integral oil system reduces the system piping complexity, and subsequently minimizes potential leak points. 4

MICROPROCESSOR CONTROLLER: FEATURES AND BENEFITS Magnum Microprocessor The Magnum TM microprocessor control produces a more stable operating system resulting in precise process and product temperatures improving product integrity. Advanced control algorithms provide for proper compressor control resulting in more efficient operation and longer compressor life. The microprocessor is factory installed and features pre-loaded factory set points allowing for faster startup and commissioning. Advanced diagnostic, monitoring, and data logging options assist in efficient trouble shooting should an issue arise, minimizing costs and allowing quick system recovery. Microprocessor monitors and controls: Room temperature Suction Temperature Discharge Temperature Suction Pressure Discharge Pressure Amps Defrost Time Schedules Defrost Termination (Electric Defrost Equipped Models) Evaporator Fan Delay (Electric Defrost Equipped Models) Evaporator Defrost Hold Out (Electric Defrost Equipped Models) In addition, microprocessor controls: Slide Valve Unloaded Start Condenser Fan Cycling Pre-Start System Pumpdown Finally, the Magnum TM monitors: Ambient Temperature Module Phase Loss Monitor Optical Oil Level Control Run time Cycles Alarms and Error Codes Magnum is a trademark of Micro Control Systems 5

CONDENSER FEATURES Floating Tube Coil Design Expanded (Locked) Auxiliary Tubes These tubes do not carry refrigerant and are in place to support the fin pack and the tubes that are carrying refrigerant. They are expanded into the end and center supports. Free Floating Circuited Coil Tubes These tubes carry refrigerant and never contact any sheet metal (end supports and center supports). All units include a limited Five Year Warranty against condenser leaks at tube sheets and center supports. All SSV/DSV condensers use the Floating Tube coil design to eliminate refrigerant leaks at the tube sheets. Additional anchor tubes are added to the condenser coil. Anchor tubes are expanded into the aluminum fins and condenser tube sheets. These tubes support the weight of the coil, but are not a part of the refrigerant circuit. The tubes in the refrigerant circuit are expanded into the fins, but float through oversized holes in the tube sheets. Tube sheet leaks are virtually eliminated, since the tubes which carry refrigerant never come in contact with the tube sheet. Adjustable Flooding Head Pressure Control The Need For Head Pressure Control Refrigeration condensing units must efficiently perform at varying ambient conditions. A properly sized unit will adequately perform at the highest summer ambient temperatures. However, in situations where the system must operate the majority of the time at less than design temperature, a means of providing adequate head pressure for refrigerant flow is desirable. Adjustable Two Valve Flooded Head Pressure Control The screw compressor condensing units use a factory assembled system utilizing an adjustable two valve flooding head pressure control scheme to maintain a constant head pressure at the air-cooled condensing unit during all climatic conditions when the ambient temperature drops below 75 F (typical). When the ambient is above 75 F, the condenser pressure is above the drain regulator setting; therefore, the valve remains in the full open position. AIR COOLED CONDENSER DRAIN REGULATOR As the temperature drops below 75 F, the pressure at the condenser also drops below the setting of the drain regulator. The drain regulator, sensing the reduction in condensing pressure, modulates toward the closed position, thus restricting the flow of liquid from the condenser. The liquid backs up into the condenser and floods a portion of the tubes, reducing the overall capacity of the condenser. The drain regulator valve will continue to flood the condenser until the pressure setting has been reached, providing proper head pressure at all ambient temperatures. BYPASS REGULATOR DISCHARGE LINE COMPRESSOR CHECK VALVE RECEIVER STD. LIQUID LINE OUTLET DIP TUBE 6 While the condenser floods, a second line pressurizes the receiver through the bypass regulator; therefore, the refrigerant flow from the condenser to the receiver modulates with conditions. However, the bypass from the discharge line maintains a minimum receiver pressure. These valves are adjustable and the minimum receiver pressure may be reset higher or lower depending upon application situations of a particular job.

UNIT FEATURES AND OPTIONS Standard Features Compact screw compressor(s) with slide valve unloading, integral discharge check valve, suction and discharge service valves and internal pressure relief valve. (s) include an integral oil system(s) including oil separator, oil filter, oil sight glass, oil service valve, crankcase heater and POE oil charge Floating Tube coil design. Refrigerant-carrying copper tubes do not contact any metal support sheets; instead, the coil is constructed with expanded anchor tubes that support the coil construction and do not carry refrigerant. The coil design eliminates one of the major causes of leaks in refrigeration systems Limited five-year warranty against condenser tube sheet and center support leaks Thermally protected, permanently lubricated ball bearing condenser fan motors Adjustable two valve head pressure control system including drain line check valve Receiver(s) are sized for sufficient pumpdown capacity with inlet and outlet service valves Dual pressure relief valves on receiver(s) Replaceable core liquid line filter drier(s) and sight glass(es) ETL listed control panel including: Microprocessor unit controller including room temperature control, compressor slide valve control, condenser fan cycling control and pre-start system pumpdown Control power transformer with fusing Control circuit breaker Phase loss monitor contactor(s) with overloads Condenser fan motor contactors with fusing Suction and discharge pressure transducers Suction, discharge, ambient and room temperature sensors Pumpdown switch Emergency stop switch module All sweat type connections, no flare joints to leak Cabinet is constructed from prepainted galvanized steel Designed for use with R-404A, R-507 and R407C Factory-Installed Options Replaceable core suction filter(s) Suction accumulator(s) Liquid line solenoid valve(s) Electric defrost kits including evaporator fan contactor(s) with fusing, defrost heater contactor(s) with fusing, and terminal strip Low ambient kit(s) with heated and insulated receiver Unit circuit breaker with thru the door actuator Variable speed EC condenser fan motors Three-way heat reclaim valve(s) Coated condenser coils for protection against corrosion in harsh environments 7

PERFORMANCE DATA Medium Temperature Models R404A/R507 s R404A/R507 Model Capacity @ 90 F Ambient by SST SSV050BM6^ CHS6553-50Y 1 426525 393813 363006 332056 303973 SSV060BM6^ CHS6563-60Y 1 543525 503973 462386 423871 387859 SSV070BM6^ CSH7553-70Y 1 622014 574097 528164 484458 440827 SSV080BM6^ CHS7563-80Y 1 696205 643955 593700 544083 496633 SSV090BM6^ CSH7573-90Y 1 815887 756334 699180 641772 587789 SSV110BM6^ CHS8553-110Y 1 1023199 949621 878343 808283 741392 SSV125BM6^ CHS8563-125Y 1 1154422 1074877 993550 918916 841393 SSV140BM6^ CHS8573-140Y 1 1331213 1236939 1141633 1055481 967417 DSV100BM6^ CHS6553-50Y 2 861394 794350 730996 670320 613636 DSV120BM6^ CHS6563-60Y 2 1078138 996222 917554 842504 767904 DSV140BM6^ CSH7553-70Y 2 1242424 1146246 1055194 966318 881424 25 F 20 F 15 F 10 F R404A/R507 Model Capacity @ 95 F Ambient by SST SSV050BM6^ CHS6553-50Y 1 404784 373015 343013 313930 287068 SSV060BM6^ CHS6563-60Y 1 518168 477242 438588 401473 366973 SSV070BM6^ CSH7553-70Y 1 589053 544398 499035 456961 417445 SSV080BM6^ CHS7563-80Y 1 657680 606551 559491 512614 468130 SSV090BM6^ CSH7573-90Y 1 771500 715961 660034 606819 555496 SSV110BM6^ CHS8553-110Y 1 972571 900032 834508 766274 702090 SSV125BM6^ CHS8563-125Y 1 1098981 1020599 943943 868537 797484 SSV140BM6^ CHS8573-140Y 1 1265976 1174734 1084562 999313 915316 DSV100BM6^ CHS6553-50Y 2 816016 755440 692834 634288 580026 DSV120BM6^ CHS6563-60Y 2 1024550 947130 868932 796000 726238 DSV140BM6^ CSH7553-70Y 2 1175996 1086180 997486 914814 831490 25 F 20 F 15 F 10 F R404A/R507 Model Capacity @ 100 F Ambient by SST SSV050BM6^ CHS6553-50Y 1 382685 352929 323395 295526 269861 SSV060BM6^ CHS6563-60Y 1 490309 451308 414231 379573 345415 SSV070BM6^ CSH7553-70Y 1 555027 511972 470456 430382 392979 SSV080BM6^ CHS7563-80Y 1 618769 570745 525419 481801 439662 SSV090BM6^ CSH7573-90Y 1 727485 675373 621970 571548 524223 SSV110BM6^ CHS8553-110Y 1 921835 855696 788019 724062 662735 SSV125BM6^ CHS8563-125Y 1 1039703 962016 891734 820502 752349 SSV140BM6^ CHS8573-140Y 1 1200015 1112179 1025235 943363 864308 DSV100BM6^ CHS6553-50Y 2 774864 712518 653848 599140 545750 DSV120BM6^ CHS6563-60Y 2 968138 894046 820724 750626 685250 DSV140BM6^ CSH7553-70Y 2 1106852 1022564 940964 858914 782564 25 F 20 F 15 F 10 F 8 Notes Allowable Capacity Reduction 25% 50% 75% No Unloading ^ = Placeholder for voltage code (D or E) Allowable unit capacity reduction will vary depending upon actual operating conditions. Shading represents expected capacity reduction at given operating conditions. Additional capacity reduction may be realized during low ambient or reduced load situations. Unit microprocessor will increase capacity reduction as operating conditions allow.

PERFORMANCE DATA Medium Temperature Models R407C s R407C Model Capacity @ 90 F Ambient by SST 25 F 20 F " SSV050BM7^ CHS6553-50Y 1 386365 352990 321034 290863 262280 SSV060BM7^ CHS6563-60Y 1 493154 449269 408544 370617 333312 SSV070BM7^ CSH7553-70Y 1 564712 515134 467560 423248 380699 SSV080BM7^ CHS7563-80Y 1 637661 581135 528527 478121 430776 SSV090BM7^ CSH7573-90Y 1 745656 684741 623891 566345 510328 SSV100BM7^ CSH7583-100Y 1 868350 795016 728430 662953 600354 SSV110BM7^ CHS8553-110Y 1 981154 900158 822278 749184 680657 SSV125BM7^ CHS8563Y-125 1 1154422 1074877 993550 918916 841393 SSV140BM7^ CHS8573-140Y 1 1229670 1127670 1027693 937122 847263 DSV100BM7^ CHS6553-50Y 2 979650 897252 816938 740308 668068 DSV120BM7^ CHS6563-60Y 2 979650 897252 816938 740308 668068 DSV140BM7^ CSH7553-70Y 2 1137044 1037494 942276 851880 766882 15 F 10 F R407C Model Capacity @ 95 F Ambient by SST SSV050BM7^ CHS6553-50Y 1 369024 336625 305822 276577 249590 SSV060BM7^ CHS6563-60Y 1 470481 429369 390074 353056 317028 SSV070BM7^ CSH7553-70Y 1 539547 491486 446650 402461 361638 SSV080BM7^ CHS7563-80Y 1 605865 554757 504194 454673 410224 SSV090BM7^ CSH7573-90Y 1 712402 654200 595741 539260 486581 SSV100BM7^ CSH7583-100Y 1 829650 763518 697500 633554 575108 SSV110BM7^ CHS8553-110Y 1 941764 863955 786942 718157 649336 SSV125BM7^ CHS8563Y-125 1 1098981 1020599 943943 868537 797484 SSV140BM7^ CHS8573-140Y 1 1178594 1080735 986291 894641 811338 DSV100BM7^ CHS6553-50Y 2 939514 857670 778164 704122 634518 DSV120BM7^ CHS6563-60Y 2 939514 857670 778164 704122 634518 DSV140BM7^ CSH7553-70Y 2 1086050 987306 898546 811978 730376 25 F 20 F 15 F 10 F R407C Model Capacity @ 100 F Ambient by SST SSV050BM7^ CHS6553-50Y 1 350823 319798 290657 261749 235110 SSV060BM7^ CHS6563-60Y 1 448429 409406 370264 334164 299971 SSV070BM7^ CSH7553-70Y 1 513775 467612 424665 382159 343126 SSV080BM7^ CHS7563-80Y 1 577665 525386 478024 430973 388461 SSV090BM7^ CSH7573-90Y 1 680744 622807 565912 512604 462311 SSV100BM7^ CSH7583-100Y 1 792215 727045 665512 606003 548674 SSV110BM7^ CHS8553-110Y 1 900483 822962 751417 684622 619701 SSV125BM7^ CHS8563Y-125 1 1039703 962016 891734 820502 752349 SSV140BM7^ CHS8573-140Y 1 1127175 1032330 939678 853159 772657 DSV100BM7^ CHS6553-50Y 2 895454 814250 739016 669488 602046 DSV120BM7^ CHS6563-60Y 2 895454 814250 739016 669488 602046 DSV140BM7^ CSH7553-70Y 2 1034062 939404 854686 769704 691728 Notes Allowable Capacity Reduction 25% 75% 50% No Unloading ^ = Placeholder for voltage code (D or E) 25 F 20 F 15 F Allowable unit capacity reduction will vary depending upon actual operating conditions. Shading represents expected capacity reduction at given operating conditions. Additional capacity reduction may be realized during low ambient or reduced load situations. Unit microprocessor will increase capacity reduction as operating conditions allow. 10 F 9

PERFORMANCE DATA High Temperature Models R407C s R407C Model 45 F " Capacity @ 90 F Ambient by SST 40 F 35 F SSV050BH7^ CHS6553-50Y 1 533290 491102 451123 411747 SSV060BH7^ CHS6563-60Y 1 678277 624234 572483 523026 SSV070BH7^ CSH7553-70Y 1 793828 730586 668119 608723 SSV080BH7^ CHS7563-80Y 1 897646 826735 756193 691303 SSV090BH7^ CSH7573-90Y 1 991672 916697 845911 775591 SSV100BH7^ CSH7583-100Y 1 1201615 1109570 1022540 936926 R407C Model 45 F Capacity @ 95 F Ambient by SST 40 F 35 F SSV050BH7^ CHS6553-50Y 1 513882 472794 433412 395703 SSV060BH7^ CHS6563-60Y 1 653040 601671 550304 503119 SSV070BH7^ CSH7553-70Y 1 762872 699213 640040 581990 SSV080BH7^ CHS7563-80Y 1 860965 791518 724481 660772 SSV090BH7^ CSH7573-90Y 1 949863 880409 810138 741297 SSV100BH7^ CSH7583-100Y 1 1157353 1067426 983045 899775 DSV100BH7^ CHS6553-50Y 2 1034968 952384 871956 798064 R407C Model 45 F Capacity @ 100 F Ambient by SST 40 F 35 F SSV050BH7^ CHS6553-50Y 1 492773 453010 413935 378110 SSV060BH7^ CHS6563-60Y 1 627132 577170 528219 480718 SSV070BH7^ CSH7553-70Y 1 729761 668320 611636 556657 SSV080BH7^ CHS7563-80Y 1 820192 753818 691032 629943 SSV090BH7^ CSH7573-90Y 1 907503 840717 772056 708906 SSV100BH7^ CSH7583-100Y 1 1111034 1025251 941595 864087 DSV100BH7^ CHS6553-50Y 2 991456 911508 836616 761906 10 Notes Allowable Capacity Reduction 25% 50% 75% No Unloading ^ = Placeholder for voltage code (D or E) Allowable unit capacity reduction will vary depending upon actual operating conditions. Shading represents expected capacity reduction at given operating conditions. Additional capacity reduction may be realized during low ambient or reduced load situations. Unit microprocessor will increase capacity reduction as operating conditions allow.

PHYSICAL DATA Medium Temperature Models R-404A Models Condenser Connections No. Fans Dia. Liquid Suction Receiver (90 % Full) R404A R407C Lbs. Kg. Lbs. Kg. Unit Length Approx. Net Weight In. M. Lbs. Kg. SSV050BM*^ CHS6553-50Y 1 4 30" 1-3/8 2-1/8 162 73 173 78 159.2 4.04 3692 1675 SSV060BM*^ CHS6563-60Y 1 6 30" 1-3/8 2-1/8 195 89 208 94 212.3 5.39 4527 2053 SSV070BM*^ CSH7553-70Y 1 6 30" 1-3/8 3-1/8 195 89 208 94 212.3 5.39 5120 2322 SSV080BM*^ CHS7563-80Y 1 6 30" 1-5/8 3-1/8 232 105 248 112 212.3 5.39 5313 2410 SSV090BM*^ CSH7573-90Y 1 8 30" 1-5/8 3-1/8 338 153 360 163 265.4 6.74 6076 2756 SSV100BM*^ CSH7583-100Y 1 8 30" 2-1/8 3-1/8 - - 360 163 265.4 6.74 6098 2766 SSV110BM*^ CHS8553-110Y 1 8 30" 2-1/8 4-1/8 560 254 461 209 265.4 6.74 7360 3338 SSV125BM*^ CHS8563Y-125 1 10 30" 2-1/8 4-1/8 560 254 461 209 318.4 8.09 8064 3658 SSV140BM*^ CHS8573-140Y 1 10 30" 2-1/8 4-1/8 560 254 461 209 318.4 8.09 8336 3781 DSV100BM*^ CHS6553-50Y 2 8 30" 1-3/8 2-1/8 162 73 173 78 265.4 6.74 6434 2918 DSV120BM*^ CHS6563-60Y 2 10 30" 1-3/8 2-1/8 195 89 208 94 318.4 8.09 7366 3341 DSV140BM*^ CSH7553-70Y 2 10 30" 1-3/8 3-1/8 195 89 208 94 318.4 8.09 8532 3870 * = Placeholder for refrigerant type (6 - R-404A, 7 - R-407C) ^ = Placeholder for voltage code (D or E) Note: Model SSV100BM*^ not compatible with R-404A High Temperature Models R-407C Models Condenser Connections No. Fans Receiver (90 % Full) Unit Length Approx. Net Weight Dia. Liquid Suction Lbs. Kg. In. M. Lbs. Kg. SSV050BH7^ CHS6553-50Y 1 6 30" 1-3/8 2-1/8 173 78 212.3 5.39 4636 2103 SSV060BH7^ CHS6563-60Y 1 8 30' 1-3/8 2-1/8 248 112 265.4 6.74 5298 2403 SSV070BH7^ CSH7553-70Y 1 8 30" 1-3/8 3-1/8 360 163 265.4 6.74 6091 2763 SSV080BH7^ CHS7563-80Y 1 10 30" 1-5/8 3-1/8 461 209 318.4 8.09 7065 3205 SSV090BH7^ CSH7573-90Y 1 10 30" 1-5/8 3-1/8 360 163 318.4 8.09 7305 3313 SSV100BH7^ CSH7583-100Y 1 12 30" 2-1/8 3-1/8 597 271 371.5 9.44 7984 3621 Dimensions (Inches) Power Block 79.09 2.35 FRAME CL 82.82 11

ELECTRICAL DATA Medium Temperature Model Power Supply Condenser Air Defrost Volts Ph Hz RLA LRA Qty. of Fans FLA MCA MOPD SSV050BM*D CHS6553-50Y 1 460 3 60 86 411 4 14.0 121.5 200 SSV050BM*E CHS6553-50Y 1 575 3 60 69 329 4 11.2 97.5 150 SSV060BM*D CHS6563-60Y 1 460 3 60 108 508 6 21.0 156.0 250 SSV060BM*E CHS6563-60Y 1 575 3 60 87 406 6 16.8 125.6 200 SSV070BM*D CSH7553-70Y 1 460 3 60 128 485 6 21.0 181.0 300 SSV070BM*E CSH7553-70Y 1 575 3 60 103 404 6 16.8 145.6 225 SSV080BM*D CHS7563-80Y 1 460 3 60 144 585 6 21.0 201.0 300 SSV080BM*E CHS7563-80Y 1 575 3 60 116 433 6 16.8 161.8 250 SSV090BM*D CSH7573-90Y 1 460 3 60 162 686 8 28.0 230.5 350 SSV090BM*E CSH7573-90Y 1 575 3 60 130 546 8 22.4 184.9 300 SSV100BM7D CSH7583-100Y 1 460 3 60 170 796 8 28.0 240.5 400 SSV100BM7E CSH7583-100Y 1 575 3 60 136 666 8 22.4 192.4 350 SSV110BM*D CHS8553-110Y 1 460 3 60 185 985 8 28.0 259.3 400 SSV110BM*E CHS8553-110Y 1 575 3 60 148 642 8 22.4 207.4 300 SSV125BM*D CHS8563Y-125 1 460 3 60 216 958 10 35.0 305.0 500 SSV125BM*E CHS8563Y-125 1 575 3 60 173 843 10 28.0 244.3 400 SSV140BM*D CHS8573-140Y 1 460 3 60 246 1036 10 35.0 342.5 500 SSV140BM*E CHS8573-140Y 1 575 3 60 197 835 10 28.0 274.3 450 DSV100BM*D CSH6553-50Y 2 460 3 60 86 411 8 28.0 221.5 300 DSV100BM*E CSH6553-50Y 2 575 3 60 69 329 8 22.4 177.7 225 DSV120BM*D CSH6563-60Y 2 460 3 60 108 508 10 35.0 278.0 350 DSV120BM*E CSH6563-60Y 2 575 3 60 87 406 10 28.0 223.8 300 DSV140BM*D CSH7553-70Y 2 460 3 60 128 485 10 35.0 323.0 450 DSV140BM*E CSH7553-70Y 2 575 3 60 103 404 10 28.0 259.8 350 Evap. Fan Amps Remote Loads Defrost Heaters Amps Electric Defrost System MCA System MOP CONTACT FACTORY FOR ELECTRICAL RATINGS FOR ELECTRIC DEFROST SYSTEMS Notes * = Refrigerant (6 - R-404A/507; 7 - R-407C) MCA = Minimum Circuit Ampacity MOP = Maximum Overcurrent Protection Condensing unit data plate ratings will be based on actual system match. 12

ELECTRICAL DATA High Temperature Model Power Supply Condenser Air Defrost Volts Ph Hz RLA LRA Qty. of Fans FLA MCA MOPD SSV050BH7D CSH6553-50Y 1 460 3 60 86 411 6 21.0 128.5 200 SSV050BH7E CSH6553-50Y 1 575 3 60 69 329 6 16.8 103.1 150 SSV060BH7D CSH6563-60Y 1 460 3 60 108 508 8 28.0 163.0 250 SSV060BH7E CSH6563-60Y 1 575 3 60 87 406 8 22.4 131.2 200 SSV070BH7D CSH7553-70Y 1 460 3 60 128 485 8 28.0 188.0 300 SSV070BH7E CSH7553-70Y 1 575 3 60 103 404 8 22.4 151.2 250 SSV080BH7D CSH7563-80Y 1 460 3 60 144 585 10 35.0 215.0 350 SSV080BH7E CSH7563-80Y 1 575 3 60 116 433 10 28.0 173.0 250 SSV090BH7D CSH7573-90Y 1 460 3 60 162 686 10 35.0 237.5 350 SSV090BH7E CSH7573-90Y 1 575 3 60 130 546 10 28.0 190.5 300 SSV100BH7D CHS7853-100Y 1 460 3 60 170 796 12 42.0 254.5 400 SSV100BH7E CHS7853-100Y 1 575 3 60 136 666 12 33.6 203.6 300 2175 West Electric Park Defrost Place Blvd. Stone Mountain, GA 30087 Phone: 800.537.7775 Fax: 770.465.5900 Remote Loads heatcraftrpd.com System MCA System MOP Evap. Fan Amps Defrost Heaters Amps CONTACT FACTORY FOR ELECTRICAL RATINGS FOR ELECTRIC DEFROST SYSTEMS Notes MCA = Minimum Circuit Ampacity MOP = Maximum Overcurrent Protection Condensing unit data plate ratings will be based on actual system match. 2015 Heatcraft Refrigeration Products LLC

14 NOTES

NOTES 15

2175 West Park Place Blvd. Stone Mountain, GA 30087 Phone: 800.537.7775 Fax: 770.465.5900 heatcraftrpd.com 2015 Heatcraft Refrigeration Products LLC