GAS DETECTION International Gas Detectors CH4 NO

Similar documents
APPLICATION DATA SHEET

IGD.CO.UK

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

APPLICATION DATA SHEET

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

CH4 NO TOC-30A-AN1 TOC-30A-ANN TOC-30A-AN2 TOC-30A-AN3. Pepper Road Bramhall Technology Park Stockport SK7 5BW England. International Gas Detectors

P R O D U C T D ATA S H E E T

APPLICATION DATA SHEET

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T

IGD. O p e r a t i o n a n d M a i n t e n a n c e V International Gas Detectors. Triton House Crosby Street Stockport SK2 6SH England

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Toxic Gas Detection. Model F12. Toxic Gas Detection

TOCSIN 750 SERIES OLIVER IGD. Triton House Crosby Street Stockport SK2 6TS England

GLD-30 Gas Leak Detector

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

G-TECTA TM. Portable Gas Detection Instruments

SIL 2. Ultima X Series Gas Monitors CERTIFIED

P R O D U C T D ATA S H E E T

Personal & Portable Gas Monitors

Xgard. Fixed detectors For flammable, toxic or oxygen gases

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Sieger Apex. Flexibility that meets your requirements

Frequently Asked Questions

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

Stand Alone DYNAGARD SP Operation Manual

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

portable gas analyser

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

GAS DETECTOR ST400EC PART.NO

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Two-Channel Gas Controller

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Industrial Grade Gas Detection

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

GAS DETECTION SYSTEMS

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

International Gas Detectors Ltd. Siting Gas Detectors. Gas detectors usually fall into three specific groups for placement

Industrial Grade Gas Detection

Inc Series Digital Gas Detector/Controller. Operation Manual

2-WIRE SYSTEMS OLIVER IGD. 2-Wire. Version 3.2 T750-INST. Addressable. Triton House Crosby Street Stockport SK2 6SH England

GMA 36 Pro. Operation Manual. Stand Alone Monitor

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

GMA 36 Pro. Operation Manual. Stand Alone Monitor

GAS DETECTION SYSTEMS

Warranty Registration

Carbon Monoxide CO Transmitter ADT-X3-1110

TX6351 TX6352 Sentro 1 Universal Gas Detector Contents

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SenSmart Universal Gas Detector Series

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

gas monitoring system

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Model D12. Digital Gas Transmitter

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

SYSTEMS LTD. Model «FDG3» LEADERS IN PROCESS ANALYSIS AND CONTROL

Micro III (Models G203, G203S, and G213) Operation Manual

portable gas analyser

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

OLC(T) 100 FIXED GAS DETECTOR

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Carbon Monoxide (CO) Gas Detector, 4-20mA GCO. Automatikprodukter. Oct. 15. Features. Technical Data. Design Features. Application.

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820?

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Fixed Gas & Flame Detection International Product Range Overview

3M Oldham OLCT 100. Description. Fixed Gas Detector

SUPREMATouch. Modular Fire & Gas Detection System

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

Operation & Maintenance Manual

Gas ventilation monitoring and control system

SUPREMATouch. Modular Fire & Gas Detection System

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Carbon Monoxide (CO) Gas Detector, 4-20mA or 2-10Vdc

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

CH4 SO2NO2. C O2 mount options. The controller has two SPCO relays as standard with three 4-20mA outputs and an RS485 Modbus UK Design And Manufacture

Version Inc Series Digital Gas Detector/Controller. Operation Manual

Industrial Grade Gas Detection Detecting The Difference

Transcription:

GAS DETECTION HSCO SOCO GAS DETECTORS FOR INDUSTRIAL ENVIRONMENTS TOCSIN 150 SERIES ADDRESSABLE GAS SAMPLERS Quality Assured

HSCO SOCO In many applications in industry requiring gas detection it is often either not possible or desirable to place a gas detector in a particular location. This could be due to the environmental condition of the location or the nature of the environment. For Example BREWERIES SUMPS SLURRY PITS BORE HOLES FOOD PROCESSING CLEAN ROOMS VENTILATION DUCTS FOOD PACKAGING REFRIGERATED COLD STORES HOSPITAL THEATRES Traditionally these applications would use multi point sequential gas sampling systems. Whilst these overcome some of the issues they are a long way from continuous monitoring can be high maintenance and high cost. TOCSIN 150 Series Sampers Overcome the concerns raised by sequential samplers. These are addressable modules providing up to 4 sample points. The samplers can be mixed with conventional gas detectors to form a comprehensive monitoring solution for each part of the site. Tocsin 150 Series Addressable Sample Modules: Will run from any IGD Addressable Gas Detection Control Panel Can use any IGD Series Gas Detector (Flammable Gases, Toxic Gases, Oxygen) Up to 4 Sample points Per Module Mix With IGD Addressable Point Gas Detectors, ATEX or Safe Area Integrated Zero Check Function During Sampling Each Sample Line Is Monitored For its Running Pressure Allowing Low Flow Reporting Hydrophobic Filters Protect Against Moisture Ingress Tube End Filters Latest Piezo Pump Technology, No Pump Seals or wear Parts to Service Simple Servicing 4 Sample Ports Filtered Zero Port

HSCO SOCO TOC-30 Series Safe Area Point Detectors 4 Core Screened Highway Cable As: 4V DC 0V DC Comm A Comm B Modbus Interfaces to HMI Modules and Host systems RS 3 or RS485 Tocsin 150 Addressable Gas Sampler Tocsin 90 (illustrated), Tocsin 700 or Tocsin 65 Series Addressable Controller Tocsin 150 Addressable Gas Sampler Addressable TOCSIN 10 Series Input / Output ATEX Point Gas Nodes. Detectors Control Beacons-sounders Solenoids or Read in Other Signals - Pressure Temperature etc Addressable Relay Output Modules Intigrate Directly into External Systems

HSCO SOCO End of line filtration is important to ensure dirt, debris or liquids do not enter the gas sample lines where such material will cause blockages and be difficult to remove. The standard EOL (End of Line) Filter comprises a wall mounting high efficiency disposable filter. The filter is housed inside a stainless steel protection cover with a viewing aperture. Should the application demand a custom EOL then IGD can help. Tocsin 150 Series Samplers can be used with any IGD series Gas Detector CL VOC s O CO HS CO SO HF CHLORINE OXYGEN CARBON DIOXIDE FLAMMABLE GASES HYDROGEN SULPHIDE NITRIC OXIDE SULPHUR DIOXIDE AMMONIA CARBON MOXIDE NITROGEN DIOXIDE HYDROGEN FLUORIDE

HSCO SOCO To the Control Panel The Sampler Appears as Four Standard Gas Detection Channels In Operation The Sampler Sequentially Draws From Each Port in Sequence as: 1. Draws Through The Zero Port For The Time Set And Zero s The Detector. Moves to The First Port And Samples To Purge The Line For the Preset time 3. Updates to the Controller For the Preset Time 4. Moves to the Next Port

HSCO SOCO Use Configurator To Setup The Sample 1 Select T150 Option and Base Address Select Setup

HSCO SOCO Decide How Many Ports To Enable Set the Purge Time Set the Sample Time Note the Control Panel is Only Updated During the Sample Time Period Set the Allowable Pressure Drop at Which Point The Channel Goes Into Fault to Indicate Low Flow The Protect Max Conc Sets The Point at Which the Channel is Skipped a 5 Cycles Protect ROC Min Conc Sets the Point at Which the Channel Rate of Rise Starts to be Checked Protect ROC Rate Sets the Rate of Rise which will Cause the Channel to be Skipped The Protect Functions are Designed to Protect an Electrochemical Cell From Damage That Would Occur if the Cell Sampled a High Gas Level For a Long Period. The Trip Points Need to be Considered in Conjunction With the Channel Alarm Levels to Ensure the Channel Alarms Properly and the Cell is Protected. When the Port is in Skipping Mode the Port is Briefly Sampled to Test For Gas. If the Rate of Rise Indicates a High Level is Still Present then The Channel is Skipped. Note the Channel Will Still be in Alarm if Latching Alarms are Set.

HSCO SOCO Select Diagnostics to View a Particular Port (Address) on the Sampler. Note if you Calibrate any one Port (Address) Then Since All Ports Share the Same Sensor, All Four Ports (Addresses) Are Calibrated.

HSCO SOCO Select MORE from the Menu and the Pump Performance Can be Checked. With a Flow Meter on the Port Check For 0.8 to 1.L/min of Flow Selecting Tune Will Vary the Pump Frequency to Achieve Best Flow.

HSCO SOCO When Introducing Calibration and Zero Gases For Calibration the Samplers Pumps Must be Allowed to Sample Under Normal Conditions. A Flow Meter is Used to Set a Small Spill Flow Allowing the Sampler to Pull As Required From the Gas Line. Gas sample Line From calibration Gas Regulator