FOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION, TESTING AND MAINTENANCE APPLICATION SPECIFICATION

Similar documents
FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

WATER POWERED OSCILLATING MONITOR

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

mechanical. OPERATION Rapidrop Global

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Technical Data Approvals UL Listed and FM Approved. Refer to Tables 1, 2, and 3, as applicable.

Design Criteria. Installation

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

The Series LFII (TY3596) Residential

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

TITAN FLOW CONTROL, INC.

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Model/Sprinkler Identification Numbers

Technical Data. Installation

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

INSTALLATION, OPERATION AND MAINTENANCE

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

FOR EASY, FAST INSTALLATION AND FOR RESULTS

20 High velocity Air

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model)

IMpORTANT SAFETy INSTRUcTIONS

THERMAL SYSTEMS, INC. Installation and Operation Manual

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

M Series Fan Filter Units

ENDURANCE Conductivity Sensors

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop


Industrial Vacuums, Inc

Model 7656WCC Eye/face Wash

INSTALLATION AND OPERATION INSTRUCTIONS

DISCONTINUED VERSION The information in this manual is no longer current. OPERATING & SERVICE MANUAL

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

INSTRUCTION MANUAL HS-229G

CVS Model Inline Multi-Port Ventilators

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

Transforming Challenges with Expertise. Total Protection. from concept to commissioning

Series LFII Residential Horizontal Sidewall Sprinklers 4.4 K-factor General Description

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

AeroVent 3X Product Manual

High-Velocity Floor Fan

1/24/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Karbon Kitchen Sink Tap

CARE AND USE GUIDE UNDER ARMOUR HYDRATION BOTTLES

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

Installation Instructions / Warranty

CARE AND USE GUIDE VACUUM INSULATED HYDRATION BOTTLE

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

MaxLite LED Round Pendant Highbay Series

TECHNICAL DATA OBSOLETE

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

150 WATT PORTABLE CLAMP LIGHT 35149

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

60In. Ceiling Fan. Owner s Manual

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE

USER S OPERATING AND INSTRUCTION MANUAL

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

BERMAD Fire Protection

Instruction Manual Hydraulic Crimping Tool

B.I.C.A Built-In Coffee Appliance

Model /8300CRP-8309CRP Shower & Eye/Face Wash

INFRARED RADIANT HEATERS

Construction Heater GENERAL HAZARD WARNING

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

INSTALLATION AND OPERATING MANUAL

(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.

Model /8320CRP Shower and Eye/Face Wash

Transcription:

FOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT TECHNICAL DATA MODEL INLET SIZE WORKING PRESSURE FMA-50, FMA-65 - Carbon Steel Construction FMA-S 50, FMA-S 65 - Stainless Steel Construction 50 NB, 65 NB Minimum.8 Kg/sq.cm. (40 PSI) Maximum 7 Kg/sq.cm. ( PSI) FLANGE ANSI B16.5 class 150#SORF CONNECTION FINISH Red RAL 1 WEIGHT 50 NB - 9.9 Kg (Approx.) 65 NB - 14.0 Kg APPROVAL UL Listed & FM Approved Refer Table-I ORDERING Specify: INFORMATION a) Model and inlet size b) Inlet pressure c) Flow Solution flow required. d) Inlet Outlet flange e) Type of Foam Concentrate used APPLICATION Foam Maker is used for one of the most common applications of protecting tank seal in vertical liquid storage tank with internal floating roof with low expansion foam system. The application of aspirated foam is on the basis of the risk comprising the area in the annular ring between the rim of the floating roof and the tank shell. The Foam system design guidelines generally used are in accordance with NFPA11 standard. The Foam Makers are defined by NFPA 11 as Type II discharge outlets for delivering the low expansion aspirated foam to the seal. The Foam Makers are widely used with the Inline Foam Inductor, Balance Pressure Foam Proportioning system, Bladder Tank system and Foam tenders. SPECIFICATION Foam Maker is an air aspirating foam generator connected to the foam pourer to deliver the aspirated foam gently into the tank seal area. Foam maker covers wide range of foam solution rates from 75 to 557 litres per minute at.8 to 7 kg/sq.cm. inlet pressure. The orifice is field replaceable in the event of change in design parameters. The foam is produced by introducing air into the foam solution stream. The inlet of foam maker is designed to create venture jet which draws air into the foam solution stream. The air is drawn into the foam solution through holes located on the foam maker covered with stainless steel screen to exclude nesting birds and insects. The aerated foam is directed into the pourer for the gentle application of the expanded foam. The pourers are available in different models.* * Refer to UL/FM directory for specific foam concentrate along with working pressure and flow details. INSTALLATION, TESTING AND MAINTENANCE LISTED Carefully unpack Foam Maker. While unpacking and installation, it is to be handled with care and shocks to be avoided. Check visually for any damages. While installing, ensure that the Foam Maker is not under stress due to any misalignments in installation or variations of system piping. Ensure that the strainer assembly is clear from any blockages or damages. if strainer assembly is either blocked or damaged will adversely affect the performance of the equipment. Qualified and trained person must commission the system. After few initial successful tests, an authorized person must be trained to perform inspection and testing of the system. It is recommended to carry out physical inspection of the system regularly. The system must be fully tested at least once in a year or in accordance to standards of the organization having local jurisdiction. Do not turn off the system or any valve to make repair or test the system, without placing a roving Fire Patrol in the area covered by the system. The Patrol should continue until the system is put back in service. Also inform the local security guard and control alarm station, so as to avoid false alarm. Each system is to be flushed properly. To test the Foam Maker without discharging the foam into the tank seal area, the foam maker is to be rotated 180o away from the wind shield. The air screen is to be MARCH, 018 PAGE 1 OF 6 HD 55

inspected periodically for obstruction of air inlet holes. If any obstruction is noticed, remove the same and flush if necessary. The foam maker outlet and pourer, if exposed to atmospheric condition, should be periodically inspected for nest and other obstructions. Any obstruction if noticed must be removed and flushed to clear the discharge path. NOTE: 1. A PROVISION IS TO BE MADE FOR PRESSURE GAUGE MOUNTING AT INLET OF FOAM MAKER, WHICH MAY BE PLUGGED AFTER SUCCESSFUL COMMISSIONING OF THE SYSTEM. THIS WILL HELP TO ANALYSE THE SYSTEM WHILE COMMISSIONING.. THE OWNER IS RESPONSIBLE FOR THE TESTING, INSPECTION AND MAINTENANCE OF THE FOAM MAKER AND THE SYSTEM. 3. FM APPROVAL AND UL LISTING OF EQUIPMENT ARE VALID ONLY WHEN USED WITH HD FOAM CONCENTRATE IN A MANNER AS LISTED AND AS PER FM APPROVAL DATA. 4. FM APPROVAL IS VALID ONLY WHEN TOTAL SYSTEM IS HAVING FM APPROVED PRODUCTS. 5. REFER TO THE INDIVIDUAL FOAM UL LISTING AND FM APPROVAL FOR OPERATING & LIMITATION WITH EACH FOAM CONCENTRATE AND FOAM MAKER. Selection of HD Foam Maker: To select the size of the Foam Maker use the following formula: Q = K P Where, Q = Total solution flow in litres per minute. K = Constant for Foam Chamber P = Inlet pressure in kg/sq.cm. Example: To find K factor: Q = 150LPM P = 3.5Kg/sq.cm. K = 150 3.5 = 80.17 The K-Factor 80.17 falls within the range of the Foam Maker having 50NB size. Hence 50NB size Foam Maker to be selected. The Foam Maker can also be selected by using graph. TABLE I - Selection of 50 NB HD Foam Maker FOAM CONCENTRATE AFFF 3% AFFF 3% AR-AFFF 3X3% * APPROVALS UL LISTED FM APPROVED WORLKING PRESSURE.8 Kg/cm to 7 Kg/cm.8 Kg/cm to 7 Kg/cm 5. Kg/cm to 7 Kg/cm K-FACTOR 44.8 TO 16.6 56.8 TO 13.3 99.5 TO 138.0 TABLE II - Selection of 65 NB HD Foam Maker FOAM CONCENTRATE AFFF 3% AFFF 3% AR-AFFF 3X3% * APPROVALS UL LISTED FM APPROVED WORLKING PRESSURE.8 Kg/cm to 7 Kg/cm 4.9 Kg/cm to 7 Kg/cm 3.5 Kg/cm to 7 Kg/cm K-FACTOR 89.6 TO 07.8 158 TO 10.5 8.9 TO 11.7 * Refer to UL/FM directory for specific foam concentrate, working pressure and flow. MARCH, 018 PAGE OF 6 HD 55

FOAM MAKER 5 F 4 'A' 3 1 F1 DIMENSIONS OF FOAM MAKER in millimeter (Approximate) PART LIST MODEL FMA 50 & FMA-S 50 FMA 65 & FMA-S 65 FOAM MAKER SIZE INLET (F1) OUTLET (F) 50NB 50NB 80NB 65NB 65NB NB A ITEM NO. DESCRIPTION MATERIAL SPECIFICATION FMA FMA-S 1 ORIFICE ASSEMBLY STAINLESS STEEL STAINLESS STEEL INLET FLANGE STEEL STAINLESS STEEL 3 STRAINER ASSEMBLY STAINLESS STEEL STAINLESS STEEL 4 FOAM MAKING CHAMBER STEEL PIPE SS PIPE 5 OUTLET FLANGE STEEL STAINLESS STEEL NOTE : Strainer Assembly consists of SS perforated sheet, SS Strainer holder & Galvanised Nut/Bolt. MARCH, 018 PAGE 3 OF 6 HD 55

TYPICAL INSTALLATION OF FOAM MAKER WITH POURER (MAX) PIPING 150 150 WINDSHIELD NOZZLE APPROX. FOAM MAKER FOAM POURER MODEL-FP55 FOAM DAM * * PIPING NOTE: 1. Above dimensions (in mm) are for general guidelines only. The system designer can adopt the dimensions as per NFPA/OISD or as per the governing rules & ordinance having local jurisdiction.. See the UL Listing and FM Approval details for foam details or contact HD sales. 3. Foam Pourer Model - FP55 is standard supply in carbon steel material and optional in stainless steel. MARCH, 018 PAGE 4 OF 6 HD 55

PRESSURE VS FLOW PERFORMANCE CHARACTERISTIC UL LISTED WITH FOAM CONCENTRATE AFFF 3% 00 500 00 0 FMA 50 & FMA-S 50 FMA 65 & FMA-S 65 PRESSURE VS FLOW PERFORMANCE CHARACTERISTIC FM APPROVED WITH FOAM CONCENTRATE AFFF 3% 00 500 00 0 FMA 50 & FMA-S 50 FMA 65 & FMA-S 65 PRESSURE VS FLOW PERFORMANCE CHARACTERISTIC FM APPROVED WITH FOAM CONCENTRATE AR-AFFF 3X3% 00 5 6 7 INLET PRESSURE (KG./SQ.CM.) FMA 50 NB & FMA-S 50 NB 500 00 INLET PRESSURE (KG./SQ.CM.) FMA 65 NB & FMA-S 65 NB MARCH, 018 PAGE 5 OF 6 HD 55

LIMITED WARRANTY HD FIRE PROTECT hereby referred to as HD FIRE warrants to the original purchaser of the fire protection products manufactured by HD FIRE and to any other person to whom such equipment is transferred, that such products will be free from defect in material and workmanship under normal use and care, for two () years from the date of shipment by HD FIRE. Products or Components supplied or used by HD FIRE, but manufactured by others, are warranted only to the extent of the manufacturer s warranty. No warranty is given for product or components which have been subject to misuse, improper installation, corrosion, unauthorized repair, alteration or un-maintained. HD FIRE shall not be responsible for system design errors or improper installation or inaccurate or incomplete information supplied by buyer or buyer s representatives. HD FIRE will repair or replace defective material free of charge, which is returned to our factory, transportation charge prepaid, provided after our inspection the material is found to have been defective at the time of initial shipment from our works. HD FIRE shall not be liable for any incidental or consequential loss, damage or expense arising directly or indirectly from the use of the product including damages for injury to person, damages to property and penalties resulting from any products and components manufactured by HD FIRE. HD FIRE shall not be liable for any damages or labour charges or expense in making repair or adjustment to the product. HD FIRE shall not be liable for any damages or charges sustained in the adaptation or use of its engineering data & services. In no event shall HD Fire s product liability exceed an amount equal to the sale price. The foregoing warranty is exclusive and in lieu of all other warranties and representation whether expressed, implied, oral or written, including but not limited to, any implied warranties or merchantability or fitness for a particular purpose. All such other warranties and representations are hereby cancelled. NOTICE : The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with the provision of government codes or ordinances wherever applicable. The information provided by us is to the best of our knowledge and belief, and consist of general guidelines only. Site handling and installation control is not in our scope. Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information, recommendation or damages due to our product. Product development is a continuous programme of HD FIRE PROTECT and hence the right to modify any specification without prior notice is reserved with the company. HD FIRE PROTECT Protecting What Matters Most to You D-6/, ROAD NO. 34, WAGLE INDUSTRIAL ESTATE, THANE 604, INDIA. TEL: + (91) 158 600 FAX: +(91) 158 60 EMAIL: info@hdfire.com WEB: www.hdfire.com MARCH, 018 PAGE 6 OF 6 HD 55