FIRE PROTECTION INNOVATORS IN CABLE MANAGEMENT

Similar documents
Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures

FIREPRO SoftSeal System

MECHANICAL FIRE STOPPING SOLUTIONS

ELECTRICAL FIRE STOPPING SOLUTIONS

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL

FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE

Reacti-Therm I and III Heating Modules

Iv. 5. FIRE-RESISTANT GLASSES Introduction Pyrobel and Pyrobelite Pyropane 372

Reacti-Therm I and III Heating/Stirring Modules

Intumescent Fire Dampers

The Passive Fire Protection Handbook

Havells Fire Survival Cables

Loss Prevention Standards

Laboratory Fume Cupboards

TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S

F, T, L and W Ratings - What are the Code & Testing Requirements?

THE TRUE FIRE SURVIVAL CABLE

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

Welcome to the. Firestop Seminar. Hilti Technical and Engineering Support

Fire dampers. For diverse applications

WSU-TFREC Fire Safety Training

Technical Ventilation

The Passive Fire Protection Handbook

Protecting Facilities Against Explosions. Since 1956

4 Storage cabinets SCALA

FIRST-CLASS IN TRAINS

Fire Risks and Safety Standards

Transportation. Distribution

Essentials of Fire Fighting 6 th Edition Firefighter I

COMPACT FLAME CONTROLLER CFC 1000

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

HRV Enthalpy. Catalogue

SmartShelter Room. Technical Description. Version 1.1 Jul. 2017

HIGH EXPANSION INTUMESCENT SEALANT Prevents the spread of smoke and fire

Boiler Basics. Design and operation

Protecting Critical Facilities Against Explosions

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL

COMITÉ EUROPÉEN DES ASSURANCES

COMPACT FLAME CONTROLLER CFC 2000

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

CodeNotes. Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions. Introduction. Solar Water Heating System Designs

Fire and smoke protection for ventilation

Fire Protection. Intumescent fire and smoke seals for door assemblies

PRODUCT CATALOGUE THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

IS-ORANGE Envirograf. Orange Book. Ventilation. T +44 (0) F +44 (0)

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Fire Collars for Floor Wastes Understanding BCA Compliance Options

- CONSTRUCTION FIRE SAFETY STANDARDS

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

QUALITY CONTROL Passive House Checklist

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

Analogue Detectors. Series 200 plus

Fire Safety in a Laser Lab

Everything you need to know about Radiant Heating but didn t dare ask

PERFORMANCE OF CLT ASSEMBLIES IN FIRE

EXTINGUISHING SYSTEM DETECTION AND CONTROL

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

LPG ProteK. for commercial kitchens

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

Product. Regulations. Agrément Certificate No 92/2841 Third issue* Designated by Government to issue European Technical Approvals

EN Storage of gas cylinder

Protective & Marine Coatings Europe, Middle East, Africa & India

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Approved Sound Proofed Systems

CATALYTIC EMITTER - An old idea in new clothes

CHAPTER 5 - STRUCTURAL FIRE PRECAUTIONS

Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

WARNING: DOWNLIGHTS MUST BE FITTED CORRECTLY IN FIRE RATED CEILINGS

FACADES AND FIRE The Essential Elements

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

KD Innovative extinguishing with Novec TM 1230 by 3M TM

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

Two (2) Side Rail Cable Tray

Tel Web: dyayan.com

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

BRISTOL: A History & Future.

This place covers: Devices, apparatus and methods to prevent fires from happening, and to fight or contain active fires.

Aspirating Smoke Detection (ASD) Systems Fire Detection

John Jay College of Criminal Justice HOT WORK PERMIT STANDARD OPERATING PROCEDURES

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

FIRE PROTECTION FIRE DAMPERS ISONE+

UNDERSTANDING SAFETY CABINETS

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Rotary dimmer, single-pole

Significance of the Construction Products Regulation, including for data centers WHITEPAPER

Installation & Manual. Model T-25

Whole Home Heat Recovery Ventilation

Area Heater AH100 Series

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

Transcription:

FIRE PROTECTION INNOVATORS IN CABLE MANAGEMENT

Power Data Control Ventilation of cables Installed cost reduction Proven suitability Mechanical protection Free draining EMC protection Adaptability Bypasses obstacles Fast, easy change of level and direction Cablofil, the global solution Fire Protection EZ-Path Page 6 Range Page 4 Features Page 8 Fire-rated (Integrity E) Page 10 2

Fire protection Ez-Path TM & Cablofil the complete and certified solution 3

Passive fire protection, the golden rules : Integrity of barrier walls and floors Thermal insulation Airtight barriers for toxic smoke and gas Fire-rated (integrity E) An intumescent product : Intumescent products expand with heat. They fill any gaps created as combustible through-penetrations burn away, which otherwise would leave an opening for the passage of toxic smoke, heated gasses and fire. intumescent Product intumescent Product Mortar Mortar Volume increasing Before the fire After the fire A container The intumescent product must be contained when it expands to concentrate the pressure into the burning cables. The containment method must avoid weakening the wall and prohibit any chemical reaction with it when the intumescent product expands. If it is metallic, the container can also provide excellent electrical continuity through the opening. Excellent Danger : wall damage by the product Thermal insulation (insulation I) The cable tray, exposed to fire, can transfer heat by thermal conductivity through a wall. It creates «hot points» that can burn in contact with flammable products (cables, dust ) and allow fire propagation. It is good practice to separate the cable tray when it crosses a fire rated wall or floor. Excellent insulation Danger: Heat transfer by conduction Airtight barriers for toxic smoke and gas Toxic smoke and gas are the most dangerous elements in a fire to personal safety. It is necessary to seal the pathway and prevent smoke propagation through the opening even if the intumescent material does not expand (Cold smoke) The product must therefore take the shape of the cables which penetrate the wall and not leave an open gap around them. No smoke propagation Attention: smoke propagation possible 4

Fire protection is an essential requirement for personal and material safety. Fire protection Fire protection Fire protection has three critical factors: Prevent: The selection of non-flammable building materials. Some plastic products (like PVC) can burn easily and release toxic smoke and gases. Extinguish: Once the fire is present, the actions that are required to extinguish it : this is known as active fire protection. Contain: To prevent fire spreding from a building compartment to another : this is known as passive fire protection. Passive fire protection The partitioning of building space into smaller compartments by constructing barrier walls and floors to withstand the passage of fire, smoke and super-heated gasses over specific periods of time. The construction of barrier walls and floors to withstand the passage of fire, smoke and super-heated gasses Electrical or mechanical service lines breach a fire-barrier wall or floor. Firestop materials must be installed to restore an hourly fire-rating to fire barrier walls and floors Cable tray Unlike pipe or ducting installation, the cables present in cable tray can provide source of fuel to propagate fire, release toxic smoke and gases. They create openings that can compromise the fire barrier allowing spread of fire, toxic smoke and superheated gasses to unprotected areas. 5

EZ-Path: The solution for high traffic openings Continually changing technology and the expanding datacoms needs of modern industrial and commercial applications result in constant cable additions and changes penetrating fire rated barriers. Electrical continuity and EMC Conforms to the standard EZ Path can be ganged for expansion or segregation of cables and provides excellent cable management. EZ Path is completely compliant with the electrical continuity code and electromagnetic compatibility. A unique system An exclusive product Two intumescent pads cushion and compress the cables top and bottom and prevent smoke propagation through the opening even if the intumescent material does not expand (Cold smoke). Exposed to fire or high temperatures, this intumescent material responds to flames or heat by rapidly sealing the pathway and preventing the passage of flames and smokes. Certified product 240 minutes 240 min. Fire-rated floor and wall constructions in accordance with BS 476 :Part 20 and : the European standard EN1366-3 the American standard ASTM E814(UL1479) the German standard DIN 4102-9 6

EZ-Path : The firestop solution from CABLOFIL. EZ-Path Safe Permanent firestop protection EZ Path offers maximum resistance to fire whether it is empty or full. It provides assurance of excellent fire protection with every new or retrofit cable installation. Easy Quick and easy installation. EZ Path installations offer a clean, professional and engineered appearance.it installs in minutes. Economical Evolutionary EZ Path features a built-in firestopping system that automatically adjusts to the number of cables installed. Cables can be added or changed without the need to remove and to re-install firestopping material. 7

A successful fire stop system should not just conform with the fire protection standards but also with the relevant building regulations Food production and agricultural industrial hygiene Traditional materials used to create fire barriers are susceptible to degradation due to corrosive cleaning methods and environmental gasses. Often of a rough finish they retain dust, dirt and bacterial deposits. The steel mounting plates that seal the unit against the wall are very easy to clean. The module itself is galvanised and then covered with a thermo-hardening resin which protects it from corrosion from cleaning fluids and other corrosive elements. Gas and airtight sealing Some environments need protection from changes in pressure and exposure to gas leakage. The innovative design of the EZ-Path maintains pressure differences across the wall cavity and so limits dispersion of gas. Fire protection For optimal protection, a firebreak product obviously must react fast and effectively to block the propagation of the fire as soon as it appears. The intumescent lining in the EZ-Path reacts immediately at the contact of flame or if the ambient temperature reaches 177 C. It has an expansion coefficient of 800% which induces a very high pressure block which penetrates the cable bundle the entire length of the module. This then makes it impossible for both fire and heat to propagate and ensures the fire compartment is not compromised. Firestop device removed after 4 hours fire test. On the exposed side all the cable disappeared. On the unexposed side, they are still perfect. 8

EZ Path provides an excellent solution to the many building safety issues that exist in modern construction Features Stability in a radioactive environment Equipment that is subjected to any intense radioactivity subsequently suffers a degradation of its physical characteristics; it can then become a radioactive source itself. The component materials of the EZ Path perform well in such a radioactive environment with the housing and the intumescent lining remaining stable without becoming a radiation source after irradiation. Acoustic barrier Any break in a wall, especially where cables pass through, can degrade the sonic barrier and create sound pollution. This problem is resolved by using the EZ-Path device which surrounds the cables with the convex shaped intumscent lining and restores the sound proofing of the opening. Tests recently carried out by an Independent Laboratory classify the EZ-Path as a very good phonic insulator. It has a rate of attenuation that can reach 45dB. Hygienic partitioning Many cable support systems in buildings become contaminated by rodents or insects. They can get through the small gaps that are inevitable in traditional through wall fire protection. This problem is avoided by the way the intumescent lining of the modules marry the profile of the cables and leave no space for the passage of the rodents or insects and by the way its consistency and its composition repels them. 9

Firestop device and floor and wall plates, components of EZ-Path range, are available : separately in a kit Firestop device EZD 22 / 33 / 44 L H CF30 - CF54 - CF105 50 600 mm H L mm mm mm mm mm Kg EZD 22 37 37 267 23 31 - KIT EZD 33 75 75 267 56 69 1,2 6 250 018 EZD 44 114 102 310 78 97 2 4 250 058 KG Wall & floor plates EZD 33 - EZD 44 1 7x EZP 133W-733W 108 L EZP 133R EZP 133K-133CW mm Kg/ / EZP 133W 1 x EZD 33 102 0,2 2 250 110 EZP 233W 2 x EZD 33 185 0,2 2 250 120 EZP 333W 3 x EZD 33 291 0,3 2 250 130 EZP 433W 4 x EZD 33 406 0,4 2 250 140 EZP 733W 7 x EZD 33 610 0,7 2 250 170 L KG 203 196 EZP 544W mm L 253 139 EZP 144W-144F 197 L mm Kg/ / EZP 133R 1 x EZD 33-0,7 2 250 220 EZP 133K 1 x EZD 33-0,3 1 250 210 EZP 133CW 1 x EZD 33-0,4 2 250 240 mm Kg/ / EZP 144W 1 x EZD 44 178 0,7 2 250 230 EZP 544W 1 5 x EZD 44 610 0,5 2 250 250 EZP 144F 1 x EZD 44 178 0,3 1 250 260 Accessories mm 75 75 L EZD 33 Extension EZD 33E RCM 33 51 1 7x mm Kg / EZD 33E 1 x EZD 33 151 0,7 1 250 078 RCM 33 1 x EZD 33-0,1 2 250 206 The data contained in this catalogue is given for information only, is in no way contractual, and does not engage the responsability of the company L KG 10

EZ-Path : a complete range Range by KIT CF30 - CF54 - CF105 50 600mm EZDP 22 / 33 / 44 KG mm EZDP 22 ø 52 0,8 1 250 518 EZDP 33 80x80 1,4 1 250 028 EZDP 44 ø 152 2,3 1 250 068 Kg EZDP 33WR EZDP 33CW mm Kg EZDP 33WR 180 x 230 1 1 250 038 EZDP 33CW ø 102 1,5 1 250 048 KG EZ-Path is a product from STI 11

Technical information Cable fill OUTSIDE DIAMETER CABLE CAPACITY OF CABLE EZD 22 EZD 33 EZD44 3.5 mm 69 330 770 4.5 mm 36 165 390 5.5 mm 24 117 264 6.0 mm 20 88 210 7.5 mm 14 60 150 8.0 mm 12 54 127 10 mm 8 35 86 14 mm 4 15 39 16 mm - 12 28 18 mm - 8 23 21 mm - 6 16 22 mm - 6 14 24 mm - 5 11 26 mm - 4 9 29 mm - 2 8 32 mm - 2 5 38 mm - - 4 48 mm - - 3 60 mm - - 2 70 mm - - 1 75 mm - - 1 Please note : variations in cable type, orientation, etc... may influence and vary the loading capacity. 312 830-10/06-5M PALAS Copy even partial forbidden Extension for EZD 33 Wall and floor thickness Less than 250mm More than 250mm EZD 33 EZD 33 EZD 33E < 250mm > 250mm For more information, please visit www.ezpath-solution.com www.cablofil.com INNOVATORS IN CABLE MANAGEMENT