MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Similar documents
MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA4 Chilled & Hot Water Fan Coil

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-120HE-03 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

FCC Fan-Coil Units High-Performance, Vertical

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

Product Specifications. Vertical Floor Consoles By First Co.

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Commercial High-Efficiency Condensing Units

SKYPAK II, 3 Ton Series, gives you a

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Concealed Ducted Split Series R-407C MBH

PAJ3. Product Specifications

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II Heating & Cooling Self Contained Packages

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

GUIDE SPECIFICATIONS AQUARIUS ii

Q-TEC QC-Series Chilled Water Air Conditioner

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

catalog CDV Fan-Coil Units High-Performance, Vertical

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

General Description. Operation

MERIT Series R-410A - Upflow / Horizontal

C13-Series Engineering Guide

SeasonMaker ThinLine Fan-coil Units

VERTICAL FAN COIL UNITS

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

MERIT SERIES Up Flow / Horizontal

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Q-Tec TM QC-Series Chilled Water Air Conditioner

SeasonMaker ThinLine Fan-coil Units

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

MERIT Series R-410A - Upflow / Horizontal

SpaceKeeper Console (SKC)

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

technical guide Water-Cooled Self-Contained Units

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

TECHNICAL SPECIFICATIONS

13 GEP A L P - 1 A

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Advance Release September 2009

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

engineering guide FN Fan-Coil Units High-Performance, Horizontal

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

VertiCool Aurora Engineering Guide

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

Portable Vertical Air-Conditioning and Heating Systems

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

GUIDE SPECIFICATIONS AQUARIUS ii

Water-Cooled Self-Contained Units

Cooling/Heat Pump Convertible Air Handlers

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Cabinet Unit Heaters Steam / Hot Water

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Ruud Standard Efficiency Air Handler

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Transcription:

MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21

HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH Multiaqua Model Number: MHCCW-06-00 Part 1-General 1.01 System Description Multiaqua Chilled Water Fan Coils are manufactured with heavy gauge galvanized steel to resist corrosion. 1.02 Quality Assurance A. Certified in accordance with U.L. Standard 95, latest version (U.S.A.) B. Manufactured in a facility registered to ISO 9002, Manufacturing Quality Standard. C. Fully load tested at the factory. D. Damage resistant packaging. 1.03 Delivery, Storage and Handling A. Packaged and readied for shipment from the factory. B. Controls shall be capable of withstanding 150 F storage temperatures in the control compartment. C. Stored and handled per manufacturer s recommendations. Part 2-Product 2.01 Equipment A. General: 1. Unit shall be a factory assembled and tested chilled or hot water fan coil with electric heat. 2. Shall be assembled with heavy gauge galvanized steel. 3. Contained with the unit shall be all factory wiring, piping, associated controls and special accessories required prior to start up. B. Unit Cabinet: 1. Composed of heavy gauge galvanized steel casing with a baked polyester powder. 2. Shall be internally insulated to ensure quiet operation. C. Fan Motors: 1. Shall be available in 208/230-1-50/60 VAC. 2. Fan motors shall be three speed, direct drive, and PSC type. 3. Totally enclosed. 4. Internal overload protected. D. Blower Wheels: 1. Blower wheels are forward curved and dynamically balanced. E. Water Coil: 1. Manufactured with water coils containing 3/8 copper tubing mechanically bonded to aluminum fins. 2. Contain both a manual water drain and manual air bleed port per coil. 3. Coils shall be factory tested to 350 psig. 4. Coils shall be capable of being field converted from right to left hand connection. F. Drain Pan: 1. All drain pans shall be coated on both the interior and exterior with baked polyester powder to resist corrosion. 2. The exterior of all drain pans shall be insulated with closed cell insulation to prevent condensation. 3. Pans shall contain a left and right hand primary sloped drain connection as well as a sloped right hand secondary drain connection. G. Electric Heat: 1. Electric Heaters shall be of the rod and disk type. 2. Shall be protected by safeties. 2

Part 3-Controls and Safeties 3.01 Controls A. Fan coils shall be completely factory wired and tested. B. All components shall be wired to an internal terminal block to allow for a field installed thermostat and or Fan speed control. C. Controls shall include the following components. 1. 24vac transformer. 2. Fan relays. 3. Electric heat sequencer (s). 4. Optional Thermostats. 3.02 Safeties A. Fan coil shall be equipped with all necessary components in conjunction with the control system to provide the following protectants. 1. High temperature. 2. Over current protection. Part 4-Operating Characteristics: 4.01 Electrical Requirements A. Primary electrical power supply shall enter the unit at a single location. B. Electrical power supply shall be rated to withstand 120 F operating ambient temperatures. C. Control and high voltage points shall be accessed through terminal block. Part 5- Accessories: 5.01 Enclosures A. Fan coils shall be capable of incorporating field assembled enclosures. 1. Enclosures shall be internally insulated to ensure quite operation and increase efficiency. 2. Shall include knockouts for ease of piping and electrical in and out of the enclosures. 3. Shall include an optional return air cutout in the enclosure. 4. Shall include a supply air duct flange. 5. Shall incorporate baked polyester powder service acces s panels with and without a filtered louver Part 6- Definitions: 6.01 Abbreviations A. CFM = Cubic Feet per Minute B. DB = Dry Bulb Temperature C. EWT = Entering Water Temperature D. GPM = US Gallons Per Minute E. MBH = BTU X 1000 F. SC = Sensible Cooling G. TC = Total Cooling = Sensible + Latent H. WB = Wet Bulb Temperature I. WPD = Water Pressure Drop in feet of head J. db = Decibel Level K. m = Meter L. In = Inches M. FPI = Fins per Inch N. OD = Outside Diameter O. ID = Inside Diameter P. MCA = Minimum Circuit Amps Q. MOP = Maximum Over current Protection R. LBS = Pounds U.S. 6.02 Measurements A. All measurements with regard to length, width, and height shall be in inches 3

208/230-1- 50/60 MHCCW-06-00 Product Specifications Model Number Height Width Depth Physical Data Weight (lbs.) Coil Rows FPI Copper Diameter Water Inlet Water Outlet MHCCW-06-00 10.25 37.72 21.65 68.2 3-14 3/8 5/8 5/8 3/4 Drain Electrical Data Model Number Nominal CFM Volts Phase Hertz Electric Heat (KW) Fan Motor HP Full Load Ampacity Fuse or HACR Circuit Breaker Per Circuit Minimum Amps Maximum Amps MHCCW-06-00 675 0 1/8 1.18 1.48 3 External Static Pressure Comparative CFM Table Model Number 0.00* 0.05* 0.10* 0.15* 0.2* 0.25* 0.30* MHCCW-04 322 290 252 220 0 0 0 MHCCW-06 715 684 653 622 591 565 538 MHCCW-08 915 879 814 809 774 734 693 MHCCW-10 1007 975 944 898 853 817 780 MHCCW-12 1254 1218 1183 1147 1112 1076 1041 MCCW-16 1435 1394 1354 1313 1272 1231 1191 MCCW-20 1450 1409 1368 1327 1285 1244 1203 * External static pressure (In W.G.) 4

MHCCW-06-00 Chilled Water Performance Data MHCCW-06-00 COOLING CAPACITIES CFM EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 19613 4.0 SC 14339 WPD 6.5 TC 19796 4.25 SC 14589 675 42 WPD 7.3 TC 20268 4.5 SC 14814 WPD 8.1 TC 21168 5.0 SC 15200 WPD 9.9 *High Speed MHCCW-06-00 COOLING CAPACITIES CFM EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 17186 4.0 SC 13591 WPD 6.5 TC 17648 4.25 SC 13744 675 45 WPD 7.3 TC 18062 4.5 SC 13941 WPD 8.1 TC 18861 5.0 SC 14271 WPD 9.9 *High Speed Recommended minimum flow rate for this unit at > 2 fps is 2.75 gpm Recommended maximum flow rate for this unit at < 6 fps is 7.75 gpm 5

MHCCW-06-00 Hot Water Performance Data MHCCW-06-00 HOT WATER CAPACITIES ENTERING NOMINAL ENTERING WATER TEMPERATURE ( F) GPM WPD AIR ( F) CFM 90 100 110 120 130 140 150 160 170 180 4 6.1 18797 23544 28322 33125 37950 42791 47645 52511 57384 62264 4.25 6.9 19003 23800 28627 33479 38351 43239 48141 53053 57973 62899 50 675 4.5 7.7 19188 24030 28901 33797 38712 43643 48587 53541 58503 63471 5.0 9.4 19509 24428 29375 34344 39332 44336 49351 54376 59409 64447 MHCCW-06-00 HOT WATER CAPACITIES ENTERING NOMINAL ENTERING WATER TEMPERATURE ( F) GPM WPD AIR ( F) CFM 90 100 110 120 130 140 150 160 170 180 4 6.1 14176 18903 23662 28449 33258 38086 42928 47783 52646 57518 4.25 6.9 14328 19105 23914 28750 33607 38483 43372 48273 53184 58102 60 675 4.5 7.6 14465 19287 24141 29020 33921 38839 43771 48715 53667 58627 5.0 9.3 14702 19602 24532 29486 34461 39452 44456 49471 54494 59525 MHCCW-06-00 HOT WATER CAPACITIES ENTERING NOMINAL ENTERING WATER TEMPERATURE ( F) GPM WPD AIR ( F) CFM 90 100 110 120 130 140 150 160 170 180 4 6.1 9545 14253 18995 23766 28561 33376 34061 38952 47905 52768 4.25 6.9 9644 14402 19195 24015 28858 33721 34564 39558 48392 53301 70 675 4.5 7.6 9733 14537 19374 24239 29126 34031 38207 43051 48829 53781 5.0 9.3 9888 14770 19684 24624 29585 34564 38599 43490 49578 54601 MHCCW-06-00 HOT WATER CAPACITIES ENTERING NOMINAL ENTERING WATER TEMPERATURE ( F) GPM WPD AIR ( F) CFM 90 100 110 120 130 140 150 160 170 180 4 6.1 4905 9594 14320 19076 23857 28660 33479 38313 43158 48012 4.25 6.8 4952 9692 14468 19273 24103 28953 33821 38702 43594 48495 80 675 4.5 7.6 4994 9780 14601 19450 24324 29218 34128 39051 43986 48929 5.0 9.3 5067 9932 14830 19755 24704 29671 34655 39650 44657 49672 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: ENTERING AIR TEMPERATURE 70F DB / 60F WB GPM ENTERING WATER TEMPERATURE 140F 4 33588 4.25 33939 4.5 34255 5.0 34798 6

MHCCW-06-00 Electric Heat Performance Data Model Number Nominal CFM Electric Heat BTUH MHCCW-06-00 675 0 MHCCW-06-00 Sound Data MODEL # MHCCW-06-00 Fan Speed db @ 1 m H 44 7

MHCCW-06-00 Dimensional Drawing 8