SoaSA Technology International Ltd. Unit E,19/F, 2nd Wuhan Building Jiahe Road, Xiamen, Fujian China

Similar documents
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Determination of the fire resistance according to EN of vertical linear joints sealed with Henkel PATTEX FR66

Technical Sheet. Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1

Certificate of Compliance

Determination of the fire resistance according to EN : 2006 of vertical linear joints sealed with Henkel PATTEX FR55

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

0014-L-16/1 2 March Test report. EPDM Quickgoot system

CERTIFICATE. No. P Order No Page 1/2

Laptop Computer (OLPC)

Independent controlgears

Certifikat och provningsprotokoll för art och 4511

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

2005-CVB-R0192 Onderzoek naar de mogelijke invloed van FirePro aërosol op in werking zijnde computerapparatuur

This document is a preview generated by EVS

GASTEC QA. Approval Requirements 31-2

Power Supply for building-in TH-10280, THAILAND. See page 2. 0 Additional Information on page 2

The CE Marking Access to the European Market

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

Switching power supply. Additional Information on page 2 Input rating: Vac, 50-60Hz, 2.5A Output rating: 24Vdc, 8.33A max., 200W max.

GASTEC QA. Approval Requirements 31-1

EU Declaration of Conformity

Secure storage units - Requirements, classification and methods of test for resistance to burglary - Secure safe cabinets

Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO :2011)

CB TEST CERTIFICATE. Personal Computer. Acer Computer (Shanghai) Limited 3F, No. 168 Xizang Medium Road Huangpu District, Shanghai CHINA

Sýnishorn Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/product standard

EN ISO ÖNORM. Edition: (ISO 14937:2009)

EN ISO/IEC :2016/AC

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

DIN Rail Power Supply. Refer to page 2. [8] Additional Information on page 2. Input: Vac; 12 A; 50-60Hz Output: 24 V de; 40 A

GASTEC QA. Approval Requirements 136

ISO/TS TECHNICAL SPECIFICATION

English version. Precast concrete products - Full-scale testing requirements in standards on precast concrete products


This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD

This document is a preview generated by EVS

Construction Products Directive

SOUTH AFRICAN NATIONAL STANDARD

PACKAGING MATERIALS AND SYSTEMS FOR MEDICAL DEVICES WHICH ARE TO BE STERILIZED - PART 10: ADHESIVE COATED NONWOVEN MATERIALS OF POLYOLEFINES

BRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware

File E Vol. 1 Sec. 93 Page 1 Issued: and Report Revised:

Geregistreerde Belgische norm

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

ISO INTERNATIONAL STANDARD

Construction Products Directive

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

This document is a preview generated by EVS

BS EN : 2001 & IEC :2000

Your Key to achieving C.E Marking Compliance

ISO INTERNATIONAL STANDARD. Fire-resistance tests Elements of building construction Part 1: General requirements

This document is a preview generated by EVS

Sýnishorn Specifications for patient handling equipment used in road ambulances - Part 1: General stretcher systems and patient handling equipment

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

BRL-K602. Datum Evaluation Guideline

Provläsningsexemplar / Preview TECHNICAL REPORT. Part 3-1: Conformity verification report for IEC :2001 General requirements

This document is a preview generated by EVS

BRL-K762. Datum Concept design. Evaluation Guideline. for the Kiwa product certificate for steel pipes for the transport of drinking water

ISO INTERNATIONAL STANDARD

This document is a preview generated by EVS

GASTEC QA. Approval Requirements 6

This document is a preview generated by EVS

Gas Equipment. Volume 4 June/July Issue date: June 27, 2007

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

Fire classification of construction products and building elements

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

ISO INTERNATIONAL STANDARD

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Standard Operating Procedure Ottawa Fire Services. Fire Safety Plan Approval - Revised

De accreditatie werd uitgereikt aan/ L'accréditation est délivrée à/ The accreditation is granted to/ Die akkreditierung wurde erteilt für:

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

This document is a preview generated by EVS

EN ISO :2005/AC

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Certificate of Compliance

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

Geregistreerde Belgische norm

This document is a preview generated by EVS

This document is a preview generated by EVS

This document is a preview generated by EVS

DECLARATION OF CONFORMITY KONFORMITÄTSERKLÄRUNG

DECLARATION OF CONFORMITY

This document is a preview generated by EVS

SVENSK STANDARD SS-EN

This document is a preview generated by EVS

INTERNATIONAL STANDARD

English version. Central Secretariat: rue de Stassart 35, B Brussels

DECLARATION OF CONFORMITY

Certificate of Compliance

Report VNNF Test Report

This document is a preview generated by EVS

This document is a preview generated by EVS

This document is a preview generated by EVS

Transcription:

TNO report TC-RAP-06-23725/idl EN 356 Glass in Building-Security glazing-testing and classification of resistance against manual attack SaoSA UV H Resin Laminated De Rondom 1 P.O. Box 6235 The Netherlands www.tno.nl T +31 40 265 00 00 F +31 40 265 03 01 info-ient@tno.nl Date September 15, 2006 Author(s) J. van der Zwan Assignor SoaSA Technology International Ltd. Unit E,19/F, 2nd Wuhan Building Jiahe Road, Xiamen, Fujian China 361012 Project number 033.12242/01.01 Number of pages 9 (incl. appendices) All rights reserved. No part of this report may be reproduced and/or published in any form by print, photoprint, microfilm or any other means without the previous written permission from TNO. All information which is classified according to Dutch regulations shall be treated by the recipient in the same way as classified information of corresponding value in his own country. No part of this information will be disclosed to any third party. In case this report was drafted on instructions, the rights and obligations of contracting parties are subject to either the Standard Conditions for Research Instructions given to TNO, or the relevant agreement concluded between the contracting parties. Submitting the report for inspection to parties who have a direct interest is permitted. 2006 TNO

TNO report TC-RAP-06-23725/idl September 15, 2006 2 / 9 Contents 1 Processor/manufacturer of the samples... 3 2 Product description & results... 4 3 Signature... 5

TNO report TC-RAP-06-23725/idl September 15, 2006 3 / 9 1 Processor/manufacturer of the samples Production plant of the sampels : SaoSA glass lamination plant Sampling date : February 2006 Under responsibility of: SoaSA Technology International Ltd. Unit E,19/F, 2nd Wuhan Building Jiahe Road, Xiamen, Fujian China 361012

TNO report TC-RAP-06-23725/idl September 15, 2006 4 / 9 2 Product description & results Not. Body number of testing laboratory : 1174 for CPD 89/106/EEC Date of test : 10-07-2006 Reference of test procedure : EN356: 1999 Commercial product name : SaoSA UV-H Resin Laminated Glass Product configuration : 5-2-8-1.5-5 Side to present the impact : first component (5-2-8-1.5-5) Nominal thickness of tested glass test specimen : 20.84 mm, 20.77 mm, 20.80 mm Product conforms to EN12543 : YES Glass type : Laminated safety glass Glass substrate : Floatglass (EN572)* Intermediate layer : 2 x SaoSA UV-H RESIN Foil : NA * substrate float glass conforms to applicable standards from selected manufacturer or supplier Requested classification Test results: Test piece Actual thickness (mm) Number of impact Hammer Number of impact Axe Number of Impact Total CLASS 1 20.8 27 32 59 P7B 2 20.8 26 28 54 P7B 3 20.8 25 30 55 P7B Conclusion: The samples considered in this report are in compliance with the requirements of the EN 356 standard: class P7B. Remark : In case of changes that may influence the validity of this ITT, the producer will take the appropriate actions.

TNO report TC-RAP-06-23725/idl September 15, 2006 5 / 9 3 Signature Eindhoven, September 2006 TNO Science and Industry Business Unit Testing & Consultancy J. van der Zwan, B.Sc. K.K. Pahnke, M.Sc. Author Head of Department

TNO report TC-RAP-06-23725/idl September 15, 2006 6 / 9 TNO Industrie en Techniek Postbus 6235 Nederland Not. Lab. 1154 Datum: 15-09-2006 EN 356:1999 Beproeving en classificatie van de weerstand tegen manuele aanval (Voor details, zie het testrapport) Not. Body nummer : 1174 voor 1989/106/EEC Datum van uitvoering : 10-07-2006 Referentie voor de testprocedure : EN356: 1999 Commerciële product naam : SaoSA UV - H Resin Laminated Opdrachtgever : SaoSA Technology International Ltd. Product configuratie : 5-2-8-1.5-5 gelamineerd glass Beproefde classificatie Product: SaoSA UV H Resin Laminated Glass (5-2-8-1.5-5) Testresultaat: P7B De geteste monsters voldoen aan de gestelde eisen in de EN 356:1999. De sampling is onder verantwoordelijkheid van SaoSA Technology International uitgevoerd. Ondertekening: J. van der Zwan, B.Sc. A.J. Piers, B.Sc. Project Leader Programme Leader

TNO report TC-RAP-06-23725/idl September 15, 2006 7 / 9 TNO Science and Industry B.P 6235 Pays-Bas Not. Lab. 1154 Date: 15-09-2006 EN 356: 1999 Mise à essai et classification de la résistance à l attaque manualle (Pour de plus amples détails, prière de se référer au rapport sur les essais). Numéro de notification de l'organisme : 1174 pour CPD 89/106/EEC Date d'exécution : 10-07-2006 Référence de la procédure des essais : EN356: 1999 Nom commercial du produit : : SaoSA UV H Resin Laminated Maître de l'ouvrage : : SaoSA Technology International Ltd. Configuration du produit : 5-2-8-1.5-5 verre feuilleté Classification Produit: SaoSA UV H Resin Laminated Glass (5-2-8-1.5-5) Résultat des essais: P7B Les échantillons mis à l'essai remplissent les conditions définies dans EN 356:1999. SaoSA Technology International sont responsable pour de prendre les échantillons et la production des échantillons. Signature: J. van der Zwan, ingénieur A.J. Piers, ingénieur Chef de project Chef de programme

TNO report TC-RAP-06-23725/idl September 15, 2006 8 / 9 TNO Science and Industry P.O.Box 6235 Netherlands Not. Lab. 1154 Date: 15-09-2006 EN 356:1999 Testing and classification of resistance against manual attack (For details, refer to the test report) Not. Body number : 1174 for CPD 89/106/EEC Date of test : 10-07-2006 Reference of test procudure : EN356: 1999 Commercial product name : SaoSA UV H Resin Laminated Company for which the tests has been done : SaoSA Technology International Ltd. Product configuration : 5-2-8-1.5-5 laminated glass Obtained classification Product: SaoSA UV H Resin Laminated Glass (5-2-8-1.5-5) Test result: P7B The tested samples are complying with the requirements of EN 356:1999. SaoSA Technology International is responsible for the production and selection of the samples. Signature: J. van der Zwan, B.Sc. A.J. Piers, B.Sc. Project Leader Programme Leader

TNO report TC-RAP-06-23725/idl September 15, 2006 9 / 9 TNO Science and Industry Postfach 6235 Netherlands Not. Lab. 1154 Datum: 15-09-2006 EN 356:1999 Prüfverfahren und Klasseneinteilung des Widerstandes gegen manuellen Angriff (Details sind im Testbericht beschrieben) Nummer Notified body : 1174, CPD 89/106/EEC Ausführungsdatum des Tests : 10.07.2006 Referenz für das Prüfverfahren : EN356: 1999 Kommerzieller Produktname : SaoSA UV H Resin Laminated Auftraggeber der Prüfung : SaoSA Technology International Ltd. Produktkonfiguration : 5-2-8-1.5-5 Verbundglas Abgegebene Klassifikation Produkt: SaoSA UV H Resin Laminated Glass (5-2-8-1.5-5) Testergebnis: P7B Die getesteten Muster entsprechen den Anforderungen von EN 356:1999. SaoSA Technology International ist verantwortlich für die Probenahme. Unterschrift: Ing. J. van der Zwan Project Leiter Ing. A.J. Piers Programm Leiter