DETAIL SPECIFICATION

Similar documents
DETAIL SPECIFICATION

DETAIL SPECIFICATION SHEET

DTS SERIES CONNECTORS

MIL-DTL-38999, SERIES I, II & III CIRCULAR CONNECTORS

Circular Robotic Connectors

COMMERCIAL ITEM DESCRIPTION TRAPS, STEAM

SUPPLEMENTAL INFORMATION SHEET FOR QPL SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST

MIL-STD-1407B 17 December 1985 SUPERSEDING MIL-STD-1407A 16 July 1975 MILITARY STANDARD HEATERS, VEHICULAR COMPARTMENT; HEATERS, COOLANT, ENGINE;

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Space Products Mission-Critical Reliability

Battery Interconnects

ARINC 801 Fiber Optic Interconnects for Aerospace & Defense. A Complete End-to-End Solution Featuring Connectors, Termini & Cable Harnesses

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Amphenol. Submariner.

Model: FT110 Dishwasher

This document is a preview generated by EVS

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system


OIL SEPARATORS APPLICATIONS

Thecompleterequirements forprocuringthecrimpingtooldescribedhereinshall,; consistof thisdocumentandthelatest

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Settlement Agreement. Schedule 1: Covered Products

MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS

Downloaded from MILITARY SPECIFICATION EXTINGUISHER, FIRE, VAPORIZING- LIQUID

Gas Range Catalogue. Tel: +44 (0) Fax: +44 (0) Website:

Heat Exchanger Block Replacement Instructions

Printed Circuit Board Connectors

SUPPLEMENTAL INFORMATION SHEET FOR QPL SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST

Cater Hoses. Manufactured to BS669 PT2: /2 & 3/4 Braided Cater Hose with Lanyard - Quick Release

ELECTRONIC WARFARE INTERCONNECTION SOLUTIONS

SUPPLEMENTAL INFORMATION SHEET FOR QPL SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

VACUUM VALVES AND HOSES

DETAIL SPECIFICATION SALINITY INDICATING EQUIPMENT

Service Data Vickers. Piston Pumps. PVH98/106 Variable Displacement Piston Pump - 11 Design M-2208-S. Revised 05/01/97

Tools & Test Equipment

SUPPLEMENTAL INFORMATION SHEET FOR QPL SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST

SUPPLEMENTAL INFORMATION SHEET FOR QPL SUPPLEMENTAL INFORMATION SHEET FOR QUALIFIED PRODUCTS LIST

Shay Plumbing IX - Feed Water Pipes

0820AR Roto-Jet I Cleaning System

DEUTSCH D3 SERIES PCB CONTACTS FOR SERIES III-STYLE CONNECTORS

General Specifications

DMFPM-2R MULTIFUNCTIONAL

Repair Parts List DRYER MODEL NUMBER MDG30PN3AW. When requesting service or ordering parts, always provide the following information:

HAKKO 703B REWORK SYSTEM TROUBLESHOOTING GUIDE

Service Data Vickers. Piston Pumps. PVH74/81 Variable Displacement Piston Pump - 11 Design M-2207-S. Revised 11/01/97

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Vickers. Service Data. Piston Pumps. PVH57/63 Variable Displacement Piston Pump - 11 Design M-2206-S. Revised 11/01/97

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

P.68 VARIANTS. SERVICE BULLETIN No. 195 Rev. 1 (Supersedes the previous issue dated 19 February 2014)

Waterproof Circular Connectors

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Electric Air Heating Standard product ranges

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Kallista Bath Flip Drain

SAFE, FAST PROFESSIONAL WIRING SOLUTIONS STANDARDISED & INDIVIDUAL COMPLEX SMART SOLUTIONS. 25 years: You name it. We have it. DANNEWITZ GmbH & Co

DETAIL SPECIFICATION. EXTINGUISHER, FIRE, HALOCARBON (HFC-236fa), PORTABLE, WITH MOUNTING BRACKET, FOR AVIATION USE

Nominal Diameter mm (in) mm (in) mm (in) mm (in) mm (in) mm (in)

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

CEILING FAN OWNER'S MANUAL

Sealed Type Liquid Line and Suction Line Specifications

CII FCAC-150 Series Relay

M7100 Pressure Transducer

DLA Land and Maritime - VQ Supplemental Information Sheet for Electronic QPL-81381

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

M5200 Industrial Pressure Transducer

The activity responsible for this QPL is the Defense Supply Center Columbus (DSCC-VQ), Columbus, OH

TSX70. SMT Reflow Vacuum Workstation. ï COMPLIES WITH MIL-S-45743E, MIL-STD-2000, DOD-STD B, WS6536E AND ESD SPEC, DOD-STD-1686, DOD-HDBK-263

Installation Instructions for Med Touch Master Alarms - Wireless

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

AD-236 Parts Manual. 24 VAC Phase 5

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

SWITCHING SWITCHING. Overhead Electric Distribution Standards INTRODUCTION

REVERSE CYCLE SOLAR PV-INVERTER

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES WE GO TO EXTREMES TO MAKE EVERY CONNECTION COUNT

OEM Sensors for HVAC manufacturers Heat recovery Chiller

QUADRAX D-SUB CONNECTORS

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

For Heavy Duty Commercial and Industrial Environments

MILITARY/AEROSPACE MARKETS INNOVATIVE SOLUTIONS GUIDE

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

CIVIL AEROSPACE. Innovative Interconnection Solutions

CEILING FAN OWNER'S MANUAL

WASHER/DRYER CONTROL PANEL PARTS For Model: MET3800TW2 (White)

AD-24 Parts Manual 24 VAC Phase 7

GENESIS I Model #W035098CA Model #W035098IA Rev. 01. E 2002 Polaris Sales Inc. PARTS MANUAL PN and MICROFICHE PN /03

One-Touch Locking Style Small Sized Circular Connectors

Hose Clamps, Charge Air Cooler, Replacement page 2

CHAPTER 21 AIR CONDITIONING

MK-MANTA III OWNER S MANUAL PARTS LIST & OPERATING INSTRUCTIONS

Section 8: Switchgear Connections (Straight & Elbows)

A HEATER KIT With Diesel Engine Connection Fittings

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

THE SCIENCE OF CERTAINTY. Positronic Company Overview

DEPARTMENT OF DEFENSE HANDBOOK COVERED STORAGE 1. THE FOLLOWING PAGES OF MIL-HDBK-1032/2 HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED:

Cartridge/Insertion Heaters

Intelligent Refrigeration Solutions

SM CONNECTOR. 1Certified LR R Specifications. Standards. 2.5mm pitch/disconnectable Crimp style wire-to-wire connectors

Transcription:

INCH-POUND MIL-DTL-38999M 11 February 2015 DETAIL SPECIFICATION CONNECTORS, ELECTRICAL, CIRCULAR, MINIATURE, HIGH DENSITY, QUICK DISCONNECT (BAYONET, THREADED, OR BREECH COUPLING), ENVIRONMENT RESISTANT WITH CRIMP REMOVABLE CONTACTS OR HERMETICALLY SEALED WITH FIXED, SOLDERABLE CONTACTS, GENERAL SPECIFICATION FOR This supplement forms a part of MIL-DTL-38999M, dated 11 February 2015. SERIES I, SCOOP PROOF, BAYONET COUPLING CONNECTORS MIL-DTL-38999/9 - Connectors, Electrical, Circular, Receptacle, Dummy Stowage, Bayonet Coupling, (MIL-C-27599 Series I, and MIL-DTL-38999 Series I). MS27466 - Connectors, Receptacle, Electrical, Wall Mounting Flange, Crimp Type, Bayonet MS27467 - Connectors, Plug, Electrical, Straight, Crimp Type, Bayonet Coupling, Series I. MS27468 - Connectors, Receptacle, Electrical, Jam Nut Mounting, Crimp Type, Bayonet MS27469 - Connectors, Receptacle, Electrical, Wall Mounting Flange, Solder Type, MS27470 - Connectors, Receptacle, Electrical, Jam Nut Mounting, Solder Type, MS27471 - Connectors, Receptacle, Electrical, Solder Mounting, Solder Type, MS27496 - Connectors, Receptacle, Electrical, Box Mounting, Crimp Type, Bayonet MS27505 - Connectors, Receptacle, Electrical, Back Panel, Box Mounting Flange, Crimp Type, Bayonet MS27515 - Connectors, Receptacle, Electrical, Crimp Type, Back Panel, Wall Mounting Flange, Series I, (Inactive / use MS27656). MS27652 - Connectors, Receptacle, Electrical, Wall Mounting Flange, Crimp Type, Bayonet Coupling, Series I (Inactive / use MS27466). MS27653 - Connectors, Plug, Electrical, Straight, Crimp Type, Bayonet Coupling, Series I, (Inactive / use MS27467). MS27654 - Connectors, Receptacle, Electrical, Back Panel, Wall Mounting Flange, Crimp Type, Bayonet Coupling, Series I, (Inactive / use MS27656). MS27656 - Connectors, Receptacle, Electrical, Back Panel, Wall Mounting Flange, Crimp Type, Bayonet MS27661 - Connectors, Plug, Electrical, Crimp Type, Lanyard Release, Fail-Safe, Series I. MS27662 - Connectors, Receptacle, Electrical, Thru-Bulkhead Mounting, Bayonet AMSC N/A FSC 5935

SERIES II, NON-SCOOP-PROOF, BAYONET COUPLING, LOW SILHOUETTE CONNECTORS MIL-DTL-38999/10 - Connectors, Electrical, Circular, Receptacle, Dummy Stowage, Bayonet Coupling Flange, (MIL-C-27599 Series II, and MIL-DTL-38999 Series II) MS27472 - Connectors, Receptacle, Electrical Wall Mounting Flange, Crimp Type, Bayonet Coupling, MS27473 - Connectors, Plug, Electrical Straight, Crimp Type, Bayonet Coupling, MS27474 - Connectors, Receptacle, Electrical, Jam Nut Mounting, Crimp Type, Bayonet Coupling, MS27475 - Connectors, Receptacle, Electrical, Wall Mounting Flange, Solder Type, Hermetic Seal, MS27476 - Connectors, Receptacle, Electrical, Box Mounting, Solder Type, Hermetic Seal, MS27477 - Connectors, Receptacle, Electrical Jam Nut Mounting, Solder Type, Hermetic Seal, MS27478 - Connectors, Receptacle, Electrical Solder Mounting, Solder Type, Hermetic Seal, MS27479 - Connectors, Receptacle, Electrical, Wall Mounting Flange, Crimp Type, Bayonet Coupling, MS27480 - Connectors, Plug, Electrical, Straight, Crimp Type, Bayonet Coupling, MS27484 - Connectors, Plug, Electrical, Straight, Crimp Type, Bayonet Coupling, EMI, MS27497 - Connectors, Receptacle, Electrical, Back Panel, Wall Mounting Flange, Crimp Type, Bayonet Coupling, MS27499 - Connectors, Receptacle, Electrical, Box Mounting Flange, Crimp Type, Bayonet Coupling, MS27500 - Connectors, Plug, Electrical, 90 Degree Elbow, Crimp Type, Bayonet Coupling, MS27508 - Connectors, Receptacle, Electrical, Back Panel, Box Mounting Flange, Crimp Type, Bayonet Coupling, MS27513 - Connectors, Receptacle, Electrical, Box Mounting Flange, Extended Grommet, Crimp Type, Bayonet Coupling, 2

SERIES III, SCOOP-PROOF, SELF-LOCKING, ENVIRONMENT RESISTANT, TRIPLE START THREADED COUPLING CONNECTORS MIL-DTL-38999/20 - Connectors, Electrical, Circular, Receptacle, Threaded, Wall Mounting Flange, Removable Crimp Contacts, Series III, MIL-DTL-38999/21 - Connectors, Electrical, Circular, Threaded, Receptacle, Box Mounting Flange, Hermetic Solder Contacts, Series III, MIL-DTL-38999/22 - Connectors, Electrical, Circular, Receptacle, Threaded, Dummy Stowage, Series III, MIL-DTL-38999/23 - Connectors, Electrical, Circular, Threaded, Receptacle, Jam Nut Mounting, Hermetic, Hermetic Solder Contacts, MIL-DTL-38999/24 - Connectors, Electrical, Circular, Receptacle, Threaded, Jam Nut Mounting, Removable Crimp, Contacts, Series III, MIL-DTL-38999/25 - Connectors, Electrical, Circular, Threaded, Receptacle, Solder Mounting, Hermetic, Hermetic Solder Contacts, Series III, MIL-DTL-38999/26 - Connectors, Electrical, Circular, Plug, Straight, Removable Crimp Contacts, MIL-DTL-38999/27 - Connectors, Electrical, Circular, Threaded, Receptacle, Weld Mounting, Hermetic, Hermetic Solder Contacts, Series III, MIL-DTL-38999/29 - Connectors, Electrical, Circular, Threaded, Plug, Lanyard Release, Fail-Safe, Removable Crimp Contacts, Pins, Series III, MIL-DTL-38999/30 - Connectors, Electrical, Circular, Threaded, Plug, Lanyard Release, Fail-Safe, Removable Crimp Contacts, Sockets, Series III, MIL-DTL-38999/31 - Connectors, Electrical, Circular, Threaded, Plug, Lanyard Release, Fail-Safe, Removable Crimp Contacts, Pins, Shell Size 25, Series III, MIL-DTL-38999/34 - Connectors, Receptacle, Electrical, Circular, Breakaway, Jam Nut Mounting, Removable Crimp Contacts, Sockets, Series III, Shell Size 25, MIL-DTL-38999/35 - Connectors, Receptacle, Electrical, Circular, Breakaway Wall Mounting Flange, Removable Crimp Contacts, Sockets, Series III, Shell Size 25, MIL-DTL-38999/36 - Connectors, Electrical, Circular, Threaded, Plug, Lanyard Release, Fail- Safe, Removable Crimp Contacts, Pins, Shell Size 25, Series III, Metric MIL-DTL-38999/60 - Connectors, Electrical, Plug, Circular, Threaded, Straight, Removable Crimp Contacts, Fiber Optic Termini, Tight Tolerance, Series III, Shell Size 25, MIL-DTL-38999/61 - Connectors, Electrical, Circular, Receptacle, Threaded, Wall Mounting Flange, Removable Crimp Contacts, Fiber Optic Termini, Tight Tolerance, Series III, Shell Size 25, 3

SERIES IV, SCOOP-PROOF, ENVIRONMENT RESISTANT, BREECH COUPLING CONNECTORS MIL-DTL-38999/40 - Connectors, Electrical, Circular, Receptacle, Wall Mounting Flange, Removable Crimp Contacts, Series IV, MIL-DTL-38999/41 - Connectors, Electrical, Circular, Receptacle, Box Mounting Flange, Hermetic, Breech Coupling, Hermetic Solder Contacts, Series IV, MIL-DTL-38999/42 - Connectors, Electrical, Circular, Receptacle, Box, Mounting Flange, Breech Coupling, Removable Crimp Contacts, Series IV, MIL-DTL-38999/43 - Connectors, Electrical, Circular, Receptacle, Jam Nut Mounting, Hermetic, Breech Coupling, Hermetic Solder Contacts, Series IV, MIL-DTL-38999/44 - Connectors, Electrical, Circular, Receptacle, Jam Nut Mounting, Breech Coupling Removable Crimp Contacts, Series IV, MIL-DTL-38999/45 - Connectors, Electrical, Circular, Receptacle, Solder Mounting, Hermetic, Breech Coupling, Hermetic Solder Contacts, Series IV, MIL-DTL-38999/46 - Connectors, Electrical, Circular, Plug, Breech Coupling, EMI Grounding, Removable Crimp Contacts, Series IV, MIL-DTL-38999/47 - Connectors, Electrical, Circular, Plug, Breech Coupling, Removable Crimp, Contacts, Series IV, MIL-DTL-38999/48 - Connectors, Electrical, Circular, Receptacle, Weld Mounting, Hermetic, Breech Coupling, Hermetic Solder Contacts, Series IV, MIL-DTL-38999/49 - Connectors, Electrical, Circular, Receptacle, In Line Cable, Breech Coupling, Removable Crimp Contacts, Series IV, MIL-DTL-38999/50 - Connectors, Electrical, Circular, Receptacle, Dummy Stowage, Breech Coupling, Series IV, CONNECTOR ACCESSORIES Series I and II: MS27342 - Connectors, Adapter, Electrical, Series I and II. MS27501 - Connectors, Electrical, Circular, Cover, Protective, Plug, Bayonet MS27502 - Connectors, Electrical, Circular, Cover, Protective, Receptacle, Bayonet MS27510 - Connectors, Electrical, Circular, Cover, Protective, Plug, Bayonet Coupling, MS27511 - Connectors, Electrical, Circular, Cover, Protective, Receptacle, Bayonet Coupling, MS27512 - Connectors, Electrical, Circular, Nut, Hexagon, Connector Mounting, SAE-AS85049/32 - Connector Accessories, Electrical, Backshell, Nonenvironmental, 90, Shielded Termination, Category 3C (for MIL-DTL-38999 Series I and II Connectors). 4

CONNECTOR ACCESSORIES MIL-DTL-38999M Series III and IV: MIL-DTL-38999/28 - Connectors, Electrical, Circular, Nut, Hexagon, Connector Mounting, Series II and IV, MIL-DTL-38999/32 - Connectors, Electrical, Circular, Cover, Protective, Plug, Series III, MIL-DTL-38999/33 - Connectors, Electrical, Circular, Cover, Protective, Receptacle, Series III, MIL-DTL-38999/51 - Connector, Electrical Circular, Cover, Protective, Plug, MIL-DTL-38999 Series IV. MIL-DTL-38999/52 - Connector, Electrical Circular, Cover, Protective, Receptacle, MIL-DTL-38999 Series IV. MIL-DTL-38999/62 - Sealing Boot, Size 8, Pin or Socket, Shielded Crimp Contacts, Electrical Connector, Circular, Metric CROSS-REFERENCE Cross-reference of Superseded Documents Superseded document Superseded by Superseded document Superseded by MS27481 MS27474 MS27667 ---------- MS27482 MS27475 MS27668 SAE-AS85049/56 MS27483 MS27477 MS27669 SAE-AS85049/57 MS27485 SAE-AS85049/58 MS27670 SAE-AS85049/63 MS27486 SAE-AS85049/75 MIL-C-38999/1 SAE-AS85049/27 MS27489 SAE-AS85049/32 MIL-C-38999/2 SAE-AS85049/62 MS27498 MS27467 MIL-C-38999/3 SAE-AS85049/33 MS27504 MS27499 MIL-C-38999/4 SAE-AS85049/30 MS27506 SAE-AS85049/49 MIL-C-38999/5 SAE-AS85049/17 MS27507 SAE-AS85049/47 MIL-C-38999/6 SAE-AS85049/29 MS27663 SAE-AS85049/45, /46 MIL-C-38999/7 SAE-AS85049/36 MS27664 MS27467 MIL-C-38999/8 SAE-AS85049/37 CONCLUDING MATERIAL Custodians: Preparing activity: Army - CR DLA - CC Navy - AS Air Force - 85 (Project 5935-2013-001) DLA - CC Review activities: Army - AR, MI Navy - EC, MC, OS Air Force - 19, 99 DLA IS Other - MDA NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.dla.mil. 5