Fixed-Point Interface Profiling. Multi-Point Density Array (MDA) Solution for Separation Applications

Similar documents
Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

Technologies, Solutions, and Applications. Radiation-based Level

Technologies, Solutions, and Applications. Continuous Level Coke Drum Measurement System

Radiation-based measurement Detectors

Ronan Model X96S Series Weighing System

Ronan Model X96S Series Density System

Technology Brochure. Radiation-based process instrumentation

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Temperature Solutions Line Card

Screw Compressors ESD SERIES. Capacities from: 816 to 1522 cfm Pressures from: 80 to 217 psig

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY.

Dräger Polytron 8000 Stationary gas detector (EC)

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

M E A S U R E M E N T S D I V I S I O N

Density, Concentration and Solids Content. Non-contacting measurement

Rosemount 3051CFC Compact Flowmeter

Controllers, Indicators & Set Point Programmers

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Recalibrate the way you look at gas detection

SUPREMATouch. Modular Fire & Gas Detection System

OMA-300 Process Analyzer

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

Connected Control (BCC100)

M-Switch Float Operated Liquid Level Switch

WASTEWATER Online UV%Transmission Analyzer

OPI-integris Advantages

Model D12-IR. Digital Gas Transmitter...

A New Standard of Excellence

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 8310 Stationary gas detector (DSIR)

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

SUPREMATouch. Modular Fire & Gas Detection System

SmartVFD HVAC and BYPASS

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Field Products. Experion LX. Proven DCS for a wide range of industrial applications

Dräger Polytron 8310 IR Detection of flammable gases and vapour

SECTION Fluorescent Dissolved Oxygen Measuring System

SITRANS T temperature transmitters A broad product family for every application. sitrans

Temperature Measurement

Integrated Process Solutions. Series 49. Thermal Management System

Screw Compressors. HSD Series. Capacities from: 816 to 3044 cfm Pressures from: 80 to 217 psig

Operating Instructions

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Turnstiles Transfer gates Mantraps Airlocks

Applications. Features & Benefits ULTRASONIC WATER METER

Rosemount 3051CFP Integral Orifice Flowmeter

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Rosemount 4500 Hygienic Pressure Transmitter

Radiometric Level Measurement in DCU Challenges, Solutions and Interpretation Author: Dr. Jan Sielk Process Control

Triton Series High Efficiency Boiler

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Model 144H. Product Data Sheet , Rev DB February Content

Dräger Polytron 8100 EC Detection of toxic gases and vapors

SITRANS F. SITRANS FUG1010 Clamp-on Gas Flowmeters. Answers for industry.

Rosemount 3051L Level Transmitter

EST User Manual. (Please read this manual carefully before using)

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Turnstiles Transfer gates Mantraps Airlocks

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Danfoss gas detection unit Type GD Heavy Duty

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

I/A Series 716C 1/16 DIN Temperature Controller

Intelligent sensing for every temperature and condition

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

5.0. Photoelectric Sensors. Technical Reference. Introduction

Industrial Grade Gas Detection Detecting The Difference

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

SECTION Free/Available Chlorine Analysis System

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Dependable Solutions for Gas Detection

How many wireless networks does it take to optimize your plant?

PURCHASING SECTION th Street, Surrey, B.C. V3S 3C7 Tel: Fax: ADDENDUM NO.

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

HIGH CAPACITY PRODUCT LINE

Screw Compressors. AS Series. Capabilities from: 64 to 143 cfm Pressures from: 80 to 217 psig. kaeser.com

PROCESS AUTOMATION TIME TO RELAX ADVANCED DIAGNOSTICS EXPERT SYSTEM AT WORK

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Sitron s CF Line of Flow Switch Monitors

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Products and performance

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Transcription:

Fixed-Point Interface Profiling Multi-Point Density Array (MDA) Solution for Separation Applications

Contents Leadership in Interface Profiling 3 System and Components Overview 4 Components 6 Principle of Operation 8 Application Areas 9 plics Easy is Better 0 2

Leadership in Interface Profiling VEGA is proud to offer the Multi-Point Density Array (MDA) solution for fixed-point interface profiling measurements. Providing high resolution and an unparalleled method of measuring interfaces, especially those with emulsion layers, the MDA operates reliably in the most difficult of applications. Why Use the MDA? The MDA system provides continuous density data at each individual measurement point, specific to each horizontal plane of elevation. As the outputs change from the multiple detectors, the operator can determine the movement of the interface or the size of the emulsion layer for optimal running efficiency of the unit. The density profile created by the MDA system provides actionable data that allows for realtime process monitoring, leading to unit efficiency that is unachievable by other measurement technologies. The system is low maintenance because all detectors mount on the outside of the vessel and have no direct contact with the process. The detectors are easily accessible for maintenance, and with multiple independent measurement points, one offline detector does not shut down operation of the system. Extensive diagnostics are possible through PACTware, or other configuration software that support DTM or EDD description technologies. Main Benefits of the MDA System: The VEGA MDA system offers many benefits to the end user. These include: High energy sources and a longer process path minimize the effects of buildup on source wells and vessel walls. High resolution detectors achieve accurate measurement. Independent density measurements ensure one detector does not influence the accuracy of another. A distributed control system (DCS) algorithm can be used to implement level and density control without requiring a separate computer. Compact detectors create a small mounting footprint. Externally mounted electronics withstand higher process temperatures. 3

System Overview The VEGA MDA system provides the ability to understand the emulsion density characteristics across the span of measurement. Understanding and monitoring these characteristics provides the operator with information that can lead to process optimization of the vessel, resulting in better performance and increased throughput. Advanced Design & Development The MDA system provides accurate and repeatable information in emulsion applications where such reliability has been historically difficult to achieve. Taking into consideration the potentially high temperature and pressure conditions and varying emulsion layer that mark some separation processes, the MDA was developed around the non-contact, radiation-based measurement principle. This principle is used to employ multiple, independent density measurement points that provide accurate and repeatable density information across the measurement span of the vessel. The system is customized per application for vessel size and configuration, process characteristics, number of interfaces, and resolution. Custom Solution Flexibility Every application is evaluated for unique requirements of the measurement system. The measurement span and resolution determine the number of detectors and the orientation of the array mounted on the outside of the vessel. This array dictates the source holder and source requirements (number, size, location, and construction) normally inserted into a dry well through a flanged interface on the vessel. Dry wells can be straight or curved to meet application needs. They can be supplied by VEGA or provided by the user. The MDA provides multiple outputs to a DCS for a graphical indication from each detector, which can be combined as appropriate to provide a thickness measurement of various interfaces, or an overall level indication. The inputs to the DCS can also be used to provide a point for the control of the lower high density product. VEGA also offers an optional visualization display. 4

Components Overview 2 MDA System Components Selection of these various components is dependent upon each application and the user s measurement need. Vessel size, shape, wall thickness, measurement span of interest, measurement span resolution, and other application variables will determine the number and specification of the individual components of the system. 4 3 Four Main Components:. MiniTrac 3 radiation-based density detector 2. SHLM source holder 3. Flexible detector mounting bracket system 4. Dry well Optional Equipment Visualization display: provides the detector outputs to indicate the process conditions X-ray interference detection system 5

Components MiniTrac 3 The MiniTrac 3 is a compact radiation-based sensor ideal for density measurements. It utilizes a highly sensitive NaI scintillation crystal and features VEGA s ProTrac family of electronics. Measuring Range: Fixed Point Ambient Temperature: -40 +40 F (-40 +60 C) Output signal: 4 20 ma/hart, Profibus PA, Foundation Fieldbus Enclosure Rating: NEMA 4X, IP 66/67 Standard Approvals Cast aluminum or stainless steel housing Communication and calibration provided by PACTware configuration software SHLM The SHLM source holder is used for critical applications when the process radiation path is too long for externally mounted sources. The SHLM utilizes a rod or cable assembly to place the sources inside the vessel in a dry well. Source Option: Single point or multi-point Multiple source configurations available Shutter lockout feature For use on high pressure or temperature applications Collimated detectors allows for high-resolution density measurement with simple calibration and no external algorithms Flexible Detector Mounting Bracket System Detectors are mounted on a flexible, stainless steel bracket system that permits the proper location and orientation of the detectors, relative to the sources in the dry well. The bracket system provides adjustment in three planes for ease of installation. Brackets can incorporate a density absorber system for calibration after the initial commissioning. Flexible mounting configuration accommodates internal structures in the vessel, such as electrostatic grids Customized design of bracket system is specified for each application for ideal mounting configuration, and simplifies customer installation engineering Single Point Multi-Point 6

Optional Components Dry Well Internal vessel dry well, curved or straight, mounts the source holder and contains small sources May use existing vessel nozzles for insertion Manufactured from various materials for process compatibility Non-destructively and hydrostatically tested Designed to piping design requirements No exotic materials needed Each dry well custom engineered for each application Enhanced visualization cabinet for interface measurement An optional visualization display locally or remotely displays the detector information. The remotelymounted system can be configured to provide the measurement outputs back to a DCS system through a single Modbus, 4 20 ma, or Ethernet digital signal. The PACTware software provides extensive diagnostics of each detector through a connection with the 4 20 ma DC HART Protocol output signal of each detector. Target Densities: upper and lower fluid Individual densities in each specific zone of measurement Indication of overall vessel levels through individual level calculations X-ray Detection System Monitors for radiation from non-destructive testing (NDT) X-ray detector alerts operator when NDT testing is in the area Protects outputs from going to a low value Prevents x-ray interference from NDT source 7

Principle of Operation A continuous density output is provided from each detector s measurement location, giving the operator information on the true, unaveraged density of the fluid at that horizontal location. As these outputs change on multiple detectors, the movement of the interface or the size of the emulsion layer can be determined. Interface with Emulsion Layer 2 3 4 5 Defined Interface 2 3 4 5 8

Application Areas Customized for vessel size and configuration, process characteristics, number of interfaces, and resolution Processes with smaller vessel dimensions, high temperature, and an emulsion layer of varying thickness are perfect for the VEGA MDA System. These applications include desalters, free water knockout drums, separators, and treaters in the oil and gas industry, where the processing of heavy crude creates more emulsion in these vessels. The MDA is also applicable in other interface applications where emulsions are present. Technology highlight: Trend Monitoring Monitoring the individual outputs from all the detectors enables the operator to see changing conditions inside the vessel. If the outputs are rising (higher specific gravity) the emulsion will be rising higher in the vessel. If the outputs drop (lower specific gravity) the emulsion will be lowering in the vessel. This trending of the outputs enables the operator to adjust their output parameters to reach the optimum performance. Alky Settler In an alkylation unit the acid settler is fed from the reactor vessel, which is used to remove acid for recycling back into the reactor. The layers created in the separation process form interfaces that must be tracked to manage the output of the material from the unit. Reporting density on a horizontal plane enables accurate control of the process and maximizes throughput, therefore controlling the acid levels for optimal processing. Reduced commission time due to calibration of air and process liquid of a known density Fixed density profile system for emulsion interface control Customizable detector system tracks multiple interfaces Desalter When heavy crude is mixed with chemicals and water in the desalter, an emulsion is created that makes interface tracking difficult for standard technologies. The MDA provides a fixed density profile over the measurement span in the desalter, allowing the unit operator to track the emulsion layer and changing interfaces within the process. Tracks emulsion layer to prevent over and under carry Remains online even when replacing a detector Optional monitoring of sludge buildup with single-point density measurement Applicable to free water knockout drums and treaters 9

plics Easy is Better Instrument Platform plics : Process Measurement Made to Order Commercially available standard solutions for measurement do not leave the user much leeway for truly optimal instrumentation. In contrast, the instrument platform plics provides a variety of configurations, which are chosen based on application requirements. The plics platform allows for the most suitable combination of sensor, electronics, and housing to be created. The result is an instrument that is highly reliable, economical, user friendly, and with short lead times. With sensors that offer reliable measurement using radiation-based technologies, and construction based on the plics principle, VEGA continues to lead the way in solving difficult and important application issues. How We Earn Your Business The Right Instrument for Every Application VEGA is committed to supplying instruments that work in all applications, not just those with ideal conditions. All new instruments are tested in extreme heat, dust, chemical, moisture, and cold environments before they are released. VEGA s goal is to enable customers to achieve operational efficiency with every measured process. Performance Guarantee To demonstrate our commitment to specifying the right instrument for each application, VEGA Americas offers a Performance Guarantee if our recommended solution does not perform exactly as expected, we ll make it right. 24 Hour Support The VEGA Field Service team is trained to provide telephone, email, or on-site customer service. Whether starting up, configuring, or troubleshooting the system, VEGA Field Service provides necessary steps to ensure the measuring device and its outputs run efficiently. Through service and training, VEGA supports all users throughout the life of the installed solutions. MDA interface system MiniTrac with ProTrac electronics 20 2006 DSG with GEN2000 electronics Motor-driven density detector 955 Motor-driven interface profiler 989 999 0

Terminals Removable Electronics 4 20 ma/ HART Profibus PA Foundation Fieldbus Housing Aluminum double chamber Stainless steel double chamber Indicating & Adjustment Module PLICSCOM VEGACONNECT DTM Sensors NaI crystal Safety standards Ship approvals Explosion protection Hyg Hygienic standards

35237-EN-6028 VEGA Americas, Inc. 470 Rosslyn Drive Cincinnati, OH 45209 USA Toll Free + 800 367 5383 Phone + 53 272 03 Fax + 53 272 033 E-mail americas@vega.com Web www.vega.com VEGA Controls Ltd Kendal House, Victoria Way Burgess Hill, West Sussex RH5 9NF, UK Phone +44 444 870055 Fax +44 444 870080 E-mail info.uk@vega.com Web www.vega.com