Figure 1 DirectLine DL423 Sensor. Description, continued

Similar documents
Figure 1 DirectLine DL423 Sensor. Description, continued

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM WASH CONF APT4000 TC

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Toroidal Conductivity Transmitters Series APT4000 Specifications

Hydrazine Analyzer Series 2171 Specifications

Controllers, Indicators & Set Point Programmers

5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8

UDA2182 Universal Dual Analyzer

UDA2182 Universal Dual Analyzer

Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications

Nov 08 PRODUCT SPECIFICATION SHEET

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Dissolved Oxygen Product Name Part No.

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Silica, Phosphate, Hydrazine Analyzers Series 2140 Specifications

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

DirectLine DL424/425 Sensor Module for DL 5000 Dissolved Oxygen Probes User Manual

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Intrinsically Safe Transmitters, Option Code 2n

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Durafet Non-Glass ph Electrodes Specifications

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

Model Q45P/R. ph/orp Monitor...

UDA2182 Universal Dual Analyzer Specifications

CONDUCTIVITY SPECIFICATIONS TEMPERATURE SPECIFICATIONS. PDFINFO p a g e

HIGH CAPACITY PRODUCT LINE

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs

Sensors and Switches in Commercial Traction Elevators

Model Q45P/R. ph/orp Monitor...

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Interactive Catalog Replaces Catalog Pages

NT DUAL CHANNEL DISPLAY. User Guide

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

TruStability Board Mount Pressure Sensors

HIGH CAPACITY PRODUCT LINE

Conductivity Product Name Part No.

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Airflow Sensors Line Guide

HIH-4030/31 Series Humidity Sensors

Interactive Catalog Replaces Catalog Pages

HIH-4010/4020/4021 Series Humidity Sensors

WH EN IGH T T C LO SED

SECTION Free/Available Chlorine Analysis System


SECTION Fluorescent Dissolved Oxygen Measuring System

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

Force Sensors Line Guide

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Wireless Panel-Mount Monitor

For the lower wiring costs of a loop-powered instrument, turn to our popular 876 Series transmitters.

Airflow Sensors Line Guide

DirectLine DL421 Sensor Module for ph Measurements User Manual

High Pressure Conductivity Monitor

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Selecting Honeywell Board Mount Pressure Sensors

BC3250. Blowdown Controller

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

MICRO SWITCH NT Series

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Linear Current Sensors

FF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features

LC1350 Level Controller

E340 BOILER CONTROL INSTALLATION MANUAL

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Gas and On-Line Analyzers

WARNING MISUSE OF DOCUMENTATION

General Purpose Industrial VRS Magnetic Speed Sensors

CO2 Sensor User and Installation Guide

ENDURANCE Conductivity Sensors

Installation Instructions for the 600 Series Optical Encoders

DirectLine DL424/425 Sensor Module for DL 5000 Dissolved Oxygen Probes User Manual

HIH-4602-L Series Humidity Sensors

Oxygen (O2) Single-Point Gas Detection System

HIH-5030/5031 Series Low Voltage Humidity Sensors

EXA Conductivity & Resistivity Analysers

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Installation Instructions for the

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Potential Applications

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

MICRO SWITCH NT Series

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Transcription:

DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 4/02 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell as part of a new generation of analytical measurement. The DirectLine sensor s unique architecture combines the latest in microelectronics technology with the proven performance of Honeywell conductivity cell, to provide unequaled savings during installation, start-up, operation, and maintenance. The DirectLine electronics module can mount integrally on the conductivity cell and provide a 4-20 ma dc output proportional to conductivity. The output of the DirectLine sensor connects directly to any host monitor or control device that accepts standard 4-20 ma inputs and provides external loop power including: Honeywell UDC3300 1/4-DIN Controller UMC800 Controller PLCs with analog inputs DCS systems A host of recorder/controller products For conductivity cell submersion or special mounting applications, the electronics module is also available in a remote-mounting configuration. Description The Honeywell DirectLine architecture consists of an electronics module integral to the conductivity cell. This design eliminates the need and added cost of a separate analyzer or transmitter. The electronics module is sealed in a plastic weatherproof, corrosionresistant IP66 housing and is connected to the conductivity cell on one side and a 4-20 ma output cable on the other via waterproof connectors. This housing design allows this system to be used in harsh environments where moisture and dust is a problem. Figure 1 DirectLine DL423 Sensor Description, continued For special mounting applications, the remote mounting option connects the electronics module to the conductivity cell via a cable. The electronics module is then mounted on a 2-inch pipe, wall, or DIN rail. Features Direct 4-20 ma output eliminates need for dedicated analyzers or transmitters, simplifying installation, start-up, operation, and maintenance tasks. Installation costs are also reduced because standard cable can be used for additional cable distances. Automatic upload of cell constant and cell calibration factor from cell EEPROM reduces set-up time. Integral electronics with local HMI simplifies installation and shortens calibration times. Modular plug-in construction simplifies electrode replacements. Local display and keypad facilitates quick set-up, calibration, and operational activities. Features, continued Plug-in modular design allows sensor to be safely removed and replaced without cycling power on the electronics module. Electronics and sensor diagnostics reduces troubleshooting times. Trim value or 1-point solution calibration options accommodates individual calibration techniques and reduces calibration time. Temperature Sensor calibration options for more accurate measurements. Playing card-sized guide facilitates simple, correct, and consistent calibration and configuration. Watertight sensor connection for reliability in submersion applications. Global approvals including: CE Mark for industrial applications UL General Purpose CSA General Purpose IP66 Enclosure Industrial Process Control, 1100 Virginia Drive, Fort Washington, PA 19034 Printed in U.S.A. Copyright 2002 Honeywell

Electronics Module Integral Electronics/Sensor Design The DirectLine electronics module is loop-powered by 16-42 Vdc source and will modulate its supply current from 4-20 ma, depending upon the conductivity value sensed by the cell. The output cable connects to the electronics module by a waterproof connector. The DirectLine sensor s output cable is a standard shielded twisted pair, which allows additional wiring to be added at minimal cost and time. The output cable length is available in either 20-ft. or 50-ft. lengths with tinned leads for easy connection by the customer. The DL423 module quickly attaches to the cell and is easily locked-in-place for assured safety and reliability during operation. The cell can be removed from the module safely without disrupting power to the electronics. Remote Mounting Applications For special mounting applications, a remote electronics module option is available. The remote electronics module is mounted on a 2-inch pipe, wall, or DIN rail. The remote sensor cable directly connects the electronics module to the sensor with a submersible connector. The remote sensor cable is available in 20-ft. and is integral with the conductivity cell. Operator Interface The DirectLine electronics module configuration, calibration, and maintenance functions are performed locally from three buttons and a 4- digit, 7-segment LCD display on the front side of the electronics module. The process variable, temperature (if available), and any error diagnostics are viewable from the local LCD display. The following configuration functions are available. PV Type (Conductivity, Resistivity, TDS, and Concentration) TDS Factor Temperature Compensation Type Output configuration Noise suppression frequency selection A playing card-sized guide comes with each DirectLine sensor to guide you through a configuration or calibration quickly. Online Diagnostics The DirectLine sensor continuously performs self-diagnostics on both the electronics and sensor. These prioritized self-diagnostics help to minimize the time and expense of troubleshooting during start-ups, maintenance, and calibrations. If a problem arises with either the module electronics or the sensor, the software prioritizes the problem type and displays only the highest priority error diagnostic thus simplifying the troubleshooting process. Once the diagnostic is corrected, the error code disappears from the display. Online Diagnostics, continued If the electrode s temperature or process variable value goes out of operation range, the output current is driven to approximately 21.8 ma to inform the host device of a problem. Once the problem is corrected, the output current is returned back to normal and the error code disappears. Error codes are also used to indicate calibration failures. Conductivity Cells Honeywell's extensive line of conductivity cells are compatible with the DL423 Sensor Module. These cells are ruggedly constructed for reliable, continuous measurement of electrolitic conductivity up to 140ºC and 250 psig. The DL4000 line of conductivity cells are used with the DL423. An integral or remote configuration is available, depending on the process installation. The integral conductivity cell design can be used for in-line and flow cell types of installations. For immersion or ball valve mountings, a remote cell design is required. The remote cell design employs a cable integral to the cell that is connected to the DirectLine Sensor Module. The conductivity cell bodies are constructed of polyethersulfone (PES) for excellent corrosion resistance in a wide range of applications. Cell constants are available for applications ranging from ultrapure water to acid/base concentrations. DL4000 Conductivity Cells have an EEPROM with the cell constant and cell calibration factor programmed into it. These values are automatically uploaded into the DirectLine Sensor Module. This eliminates the need for the user to manually do this and reduces configuration errors.

Page 3 Specifications Display Ranges Conductivity: 0 to 2000 S/cm, 0 to 20.00 ms/cm, 0 to 1000 ms/cm Displayed Temperature Range Resistivity: 0 to 20.00 M -cm Total Dissolved Solids (TDS): 0 to 2000 ppm, 0 to 2000 ppb, 0 to 200ppt % Concentration: 0 to 20.00% 10 C to +140 C (14 F to 284 F) Display Accuracy Conductivity/Resistivity: Greater of +/- 2 counts or +/- 0.5% of reading Concentration: +/- 0.5% of reading Temperature: +/- 0.1 C from 10 to 99.9 C, +/- 1 C from 100 to 140 C Display Resolution Process Temperature Electronics Module Ambient Temperature Output Type Output Calibration Cell Constant and Cell Calibration Factor Input Output (Loop) Cable Type Output (Loop) User Termination Cable Lengths Remote Sensor: Output: Power Local Display and Buttons 4 digits, floating decimal point 10 C to +140 C (14 F to 284 F) 20 C to +85 C ( 4 F to +185 F) 4-20 ma (2-wire loop powered) 4-20 ma Automatic from EEPROM in Conductivity Cell Shielded twisted pair with connector Tinned leads 20 feet (cable integral to conductivity cell) 20 feet or 50 feet 16-42 Vdc, 23mA max Maximum load resistance: LCD 4-digit, 7-segment 250 ohms at 16 Vdc 600 ohms at 24 Vdc 1400 ohms at 42 Vdc Engineering Units (Labels) S/cm, ms/cm, M -cm, ppm TDS, ppb TDS, ppt TDS, % Calibration Options Solution Temperature Compensation Diagnostics Case Approvals Remote Mounting Cal Trim Factor, 1 Point Cal Solution Acid (Cation/Ammonia), Salt (Neutral Salts), NaCl, HCl, NaOH, H 2 SO 4, and None (for USP24 Conformance) Sensor and electronics Weatherproof, corrosion-resistant plastic housing CE Mark for Industrial Applications UL General Purpose for Process Control CSA General Purpose IP66 Enclosure Pipe, Wall, or DIN Rail Dimensions H 123 mm (4.84 ) x W 48 mm (1.89 ) x D 46 mm (1.81 ) Weight Approximately 142 g (5.0 oz.)

Dimensions Mounting 48 mm 1.9 in. M O D E 1 2 95 mm 3.75 in. M O D E 1 2 Electronics Module Front View Locking Screw in Rear of Housing 46 mm 1.8 in. Conductivity Cell Side View Figure 2 Dimensions Figure 3 Integral Mounting

Page 5 Mounting Electronics Module M O D E 1 2 Remote Connector Cover Strain Relief Compression Cap Terminals for Electrode Wiring Remote Integral Cable 20 Feet Cell Figure 4 Remote Mounting

Mounting Hose Clamp Slot for Pipe Mounting (Hose Clamp included in kit) Through Hole Through Hole for DIN Rail Mounting Metal clip for U DIN rail mounting Gray clip for G DIN rail mounting Mounting Kit View from End View from End Panel Panel Terminal Connectors Barriers, Repeater, Isolators Front View Front View U Style DIN Rail G Style DIN Rail Figure 5 Remote Mounting Hardware

Page 7 Instructions Select the desired key number. The arrow to the right marks the selection available. Make the desired selections from Table I using the column below the proper arrow. A dot ( ) denotes availability. No ( ) dot denotes not available. Key Number I II III _ - _ - _ - _ - IV Model Selection Guide Key Number - DirectLine TM Sensor Electronics Module 1 (Specify electrodes, probes/cells separately) Selection Availability Stocking P/N ph For use with Durafet II, Meredian II & HPW7000 ph electrodes. DL421 51500259-001 ORP For use with ORP electrode. DL422 51500259-002 Conductivity For use with Contacting Conductivity Cells DL423 51500259-003 Dissolved Oxygen - PPM For use with Dissolved Oxygen ppm Probes DL424 51500259-004 Dissolved Oxygen - PPB For use with Dissolved Oxygen ppb Probes DL425 51500259-005 TABLE I - OUTPUT CABLE Output Cable for No cable required (replacement modules only) A c c c c c N/A Integral or Remote 20 Ft. of output cable B 51500271-001 Mounting 50 Ft. of output cable C 51500271-002 TABLE II - SENSOR CABLE/REMOTE CONNECTOR Integral Mounting Remote Mounting Cable No cable or connector required - Durafet II, Meridian II, Contacting Conductivity and Dissolved Oxygen 20 Ft. of sensor cable - Durafet II Remote Mounting 0 1 d e d d d d N/A 2 51500270-001 (Durafet only) 50 Ft. of sensor cable - Durafet II Remote Mounting 2 e 51500270-002 Remote Mounting Connector - Meredian II ph 3 e 51500768-001 Remote Mounting Remote Mounting Connector - Meredian II ORP 3 e 51500768-002 Connector (Cable supplied Remote Mounting Connector - HPW7000 4 e 51500768-003 with sensor or probe) Remote Mounting Connector - Conductivity 5 e 51500768-004 Remote Mounting Connector - Dissolved Oxygen 6 e e 51500768-005 TABLE III - REMOTE MOUNTING OPTIONS Mounting Kit for remote None Integral unit - mounting not required A N/A 2 Mounting 2" Pipe mounting bracket, wall mounting, & DIN Rail clip B 51500526-001 TABLE IV - OPTIONS Tagging Certificates None 00 N/A 2 Linen Customer ID Tag - 3 lines w/22 characters/line LT N/A 2 St. St. Customer ID Tag - 3 lines w/22 character/line SS N/A 2 None 00 N/A 2 Calibration (F3399) CA N/A 2 Conformance (F3391) C0 N/A 2 Calibration & Conformance CC N/A 2 Notes: 1. Electrodes, Probes & Cells must be specified separately: For electrodes & available mountings see: MSG DL1000 for Durafet ph, DL2000 for Meredian II, DL3000 for ORP, DL4000 for Contacting Conductivity and DL5000 for Dissolved Oxygen Probes 2 N/A=Not available via stocking part numbers. Order by model number. RESTRICTIONS Restrictions Letter c d e Available Only With Table Selection II 0 III A III B Table Not Available With Selection ORDERING INSTRUCTIONS: 1. Part numbers are provided to facilitate Distributor Stock. 2. Orders may be placed either by model selection or by part number. 3. Part numbers are shown within the model selection tables to assist with compatibility information. 4. Orders place by model selection are systematically protected against incompatability. 5. Compatibility assesment is the responsibility of the purchaser for orders placed by part number. 6. Items labeled as n/a are not available via the stocking program and must be ordered by model selection.

Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Distributor : For more information, contact Honeywell sales at 1-800-343-0228. Industrial Process Control Honeywell 1100 Virginia Drive Fort Washington, PA 19034 70-82-03-47 0402 Printed in USA www.honeywell.com/ipc