AIR-CONDITIONER SERVICE MANUAL

Similar documents
SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

Digital Inverter 4 series 8 & 10HP

TECHNICAL DATA & SERVICE MANUAL

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Compact 4-way Cassette ( ) Type

TECHNICAL DATA & SERVICE MANUAL

Air Conditioner SVC MANUAL(Exploded View)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

Highly Efficient,Powerful Heating and Cooling.

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

Кондиционеры Mitsubishi Heavy

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

ROOFTOP PACKAGED AIR CONDITIONERS

Concealed Ducted Split Series R-407C MBH

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

TECHNICAL DATA & SERVICE MANUAL

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

TOSHIBA AIR CONDITIONING

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Horizontal Water Source Heat Pumps And Cooling Only Unit

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

AIR-CONDITIONER SERVICE MANUAL SPLIT TYPE R410A OUTDOOR UNIT

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

next p dw next p dw rcgroupairconditioning

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

TABLE OF CONTENTS ERSQ-AAY1

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

R4H4. Product Specifications

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

Glass Door Merchandiser. Model RM-49

R4H4. Product Specifications

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

Wall Mounted Split Systems

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

LZT High efficiency air to water heat pumps with E.V.I. compressors

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

C. Samples for Initial Selection: For units with factory-applied color finishes.

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

4-Way Cassette type. Contents MMU-AP 2H2UL

NEXT DL NEXT DL. rcgroupairconditioning

Roof top SPACE RPC 450Z R407C M011

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

Glass Door Merchandiser. Model RM-45-SD

TABLE OF CONTENTS RMXS-E8V1B

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

PAJ3. Product Specifications

SERVICE MANUAL/INTEGRATION

unico pf unico pf rcgroupairconditioning

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

TOSHIBA Carrier (UK) Ltd. LC DX Interface Installation manual ENGLISH. For commercial use. Model name:

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

AIR-CONDITIONER SPLIT TYPE

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

Glass Door Merchandiser

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

PUHZ-SHW140YHA PUHZ-SHW230YKA

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

Transcription:

FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED IN U.K. Apr. 1996

CONTENTS 1. IMPORTANT NOTES... 3 2. SPECIFICATIONS... 4 3. CONSTRUCTION VIEWS... 7 4. WIRING DIAGRAM... 8 5. SPECIFICATIONS OF ELECTRICAL PARTS... 9 6. REFRIGERANT PIPING DIAGRAM... 10 7. PERFORMANCE CHARACTERISTICS...11 8. EXPLODED VIEWS AND PARTS LISTS... 13 SUMMARY The units referred to within this manual conform with the protection requirements of Directives 89/336/EEC Electromagnetic Compatibility and 73/23/EEC Low Voltage. Operating conditions of units are as follows: OUTDOOR TEMPERATURE -2 TO 43 C ROOM TEMPERATURE 18 TO 32 C ROOM HUMIDITY LESS THAN 80% NOTE 1: NOTE 2: Cooling Capacity is based on the following temperature conditions Indoor air inlet temperature 27 C DB, 19 C WB Outdoor air inlet temperature 35 C DB Specifications are subject to change without notice.

1. IMPORTANT NOTES a. Refer to Service Manual, File No. A90-9504 for details of indoor units and control circuits. b. Reverse Phase Protector The Scroll Compressor used in this unit can only rotate in one direction. For this reason a protective device ( Reverse Phase Protector ) is fitted to prevent incorrect wiring of electrical phases. If the red LED on the remote controller does not flash when the system is switch on, then the wiring to the outdoor unit should be checked to ensure that the three phases are wired in the correct sequence. c. Inner Overload Relay If the Inner Overload Relay operates, the Magnetic contactor will remain energised, but the compressor will stop. In this event fault Code '09' will appear on the Remote Controller. d. Delivery Temperature Thermostat. In the unlikely event of a gas leak a bi-metal thermostat is fitted to this unit to prevent the compressor from overheating. During such abnormal conditions, the thermostat operates and power to the indoor unit and remote controller is disconnected. e. Special Refrigerant Reclaim Procedure for Scroll Compressors When the refrigerant charge is reclaimed only from the discharge side of the Scroll Compressor, it is possible that the suction side of the compressor remains pressurised. If a brazing torch is applied to the suction side the pressurised refrigerant and oil mixture could ignite. THIS COULD RESULT IN A FIRE AND / OR SEVERE PERSONAL INJURY. The refrigerant gas MUST be reclaimed simultaneously from the discharge and the suction sides of the outdoor unit to avoid this potential problem.

2. SPECIFICATIONS ITEM MODEL RAV-362B-PE Cooling capacity kw 10.0 12.5 Phase 3 3 Power source V 380 415 380 415 Hz 50 50 COOLING COOLING Power consumption kw 3.9 5.0 Power Factor % 87 86 Running current A 6.5 8.4 Starting current A 42 50 Operating Indoor unit (High/Med./Low) db(a) 45/42/39 46/43/40 noise (SPL) Outdoor unit db(a) 55 59 Name of refrigerant R-22 R-22 Refrigerant Charge volume kg 2.7 3.7 Add. volume (20-50m) g/m 50 50 Refrigerant control Capillary tube Capillary tube Large side size *1 mm ø 19 (ø 22) ø 19 (ø 22) Coupler style Flare Flare Smaller side size mm ø 9.5 ø 9.5 Inter- Coupler style Flare Flare connection Standard length m 7.5 7.5 pipe Maximum pipe lengths m 50 50 Max. height difference if indoor unit higher m 20 20 Outdoor unit higher m 50 50 Condensate drain pipe diameter mm ø 32 (OD) ø 32 (OD) INDOOR UNIT RAV-362B-PE RAV-462B-PE Appearance colour Black (Zinc galvanized steel + Thermal insulation) Height mm 345 345 Dimensions Width mm 1350 1350 Depth mm 800 800 Net weight kg 53 62 Heat exchanger type Finned tube Finned tube Indoor fan type Multi-blade fan Multi-blade fan Air flow volume m 3 /h 1820 2100 Fan motor output W 120 140 External Static STANDARD mmaq 4 4 Pressure MAX. MOTOR mmaq 10 10 OUTDOOR UNIT Appearance colour Bronze white (Munsell 6Y7.5/1) Bronze white (Munsell 6Y7.5/1) Height mm 1240 1240 Dimensions Width mm 930 930 Depth mm 385 385 Net Weight kg 103 111 Heat exchange type Finned tube Finned tube Outdoor fan type Propeller fan Propeller fan Air flow volume m 3 /h 6000 6000 Fan motor output 39 + 63 39 + 63 Compressor ZR49K3-TFD ZR61K3-TFD Output kw 3.0 3.75 Fuse, Crankcase heater, Reverse Fuse, Crankcase heater, Reverse Protective device Phase Protector, Inner overload relay Phase Protector, Inner overload relay Bi-metal thermostat Bi-metal thermostat Built-in duct filter kit RBC-RK462BE-PE Air filter Washable Note 1: (ø22) should be used when the length of pipe exceeds 30m. RAV-462B-PE Metric/Imperial Pipe Comparisons Diameter (mm) 6.4 9.5 12.7 15.9 19 22 Nominal Diameter (inch) 1/4 3/8 1/2 5/8 3/4 7/8-4 -

ITEM Cooling capacity kw 10.0 12.5 Phase 3 3 Power source V 380 415 380 415 Hz 50 50 COOLING COOLING Power consumption kw 3.9 5.0 Power Factor % 87 86 Running current A 6.5 8.4 Starting current A 42 50 Operating Indoor unit (High/Med./Low) db(a) 47/43/40 49/45/41 noise (SPL) Outdoor unit db(a) 55 59 Name of refrigerant R-22 R-22 Refrigerant Charge volume kg 2.7 3.7 Add. volume (20-50m) g/m 50 50 Refrigerant control Capillary tube Capillary tube Large side size *1 mm ø 19 (ø 22) ø 19 (ø 22) Coupler style Flare Flare Smaller side size mm ø 9.5 ø 9.5 Inter- Coupler style Flare Flare connection Standard length m 7.5 7.5 pipe Maximum pipe lengths m 50 50 Max. height difference if indoor unit higher m 20 20 Outdoor unit higher m 50 50 Condensate drain pipe diameter mm ø 20 (ID) ø 20 (ID) INDOOR UNIT RAV-362C-PE RAV-462C-PE Appearance colour Silky mist Silky mist Height mm 240 240 Dimensions Width mm 1430 1630 Depth mm 640 640 Net weight kg 39 44 Heat exchanger type Finned tube Finned tube Indoor fan type Multi-blade fan Multi-blade fan Air flow volume m 3 /h 1680 2100 Fan motor output W 75 75 Air filter Washable Washable OUTDOOR UNIT Appearance colour Bronze white (Munsell 6Y7.5/1) Bronze white (Munsell 6Y7.5/1) Height mm 1240 1240 Dimensions Width mm 930 930 Depth mm 385 385 Net Weight kg 103 111 Heat exchange type Finned tube Finned tube Outdoor fan type Propeller fan Propeller fan Air flow volume m 3 /h 6000 6000 Fan motor output 39 + 63 39 + 63 Compressor MODEL RAV-362C-PE RAV-462C-PE ZR49K3-TFD ZR61K3-TFD Output kw 3.0 3.75 Fuse, Crankcase heater, Reverse Fuse, Crankcase heater, Reverse Protective device Phase Protector, Inner overload relay Phase Protector, Inner overload relay Bi-metal thermostat Bimetal thermostat Note 1: (ø22) should be used when the length of pipe exceeds 30m. - 5 -

ITEM Cooling capacity kw 10.0 12.5 Phase 3 3 Power source V 380 415 380 415 Hz 50 50 COOLING COOLING Power consumption kw 3.9 5.0 Power Factor % 87 86 Running current A 6.5 8.4 Starting current A 42 50 Operating Indoor unit (High/Med./Low) db(a) 50/45/42 52/47/44 noise (SPL) Outdoor unit db(a) 55 59 Name of refrigerant R-22 R-22 Refrigerant Charge volume kg 2.7 3.7 Add. volume (20-50m) g/m 50 50 Refrigerant control Capillary tube Capillary tube Large side size *1 mm ø 19 (ø 22) ø 19 (ø 22) Coupler style Flare Flare Smaller side size mm ø 9.5 ø 9.5 Inter- Coupler style Flare Flare connection Standard length m 7.5 7.5 pipe Maximum pipe lengths m 50 50 Max. height difference m if indoor unit higher 20 20 Outdoor unit higher m 50 50 Condensate drain pipe diameter mm ø 32 (OD) ø 32 (OD) INDOOR UNIT Appearance colour RAV-362U-PE RAV-462U-PE Black (Zinc galvanized steel + Thermal insulation) Height mm 350 350 Dimensions Width mm 1130 1130 Depth mm 740 740 Net weight kg 53 53 Heat exchanger type Finned tube Finned tube Indoor fan type Centrifugal Fan Centrifugal Fan Air flow volume m 3 /h 1680 1860 Fan motor output W 80 90 CEILING PANEL RBC-U462PG(W)-PE RBC-U462PG(W)-PE Appearance colour Silky mist (Munsell 1Y8.9/0.5) Silky mist (Munsell 1Y8.9/0.5) Height mm 28 28 Dimensions Width mm 1290 1290 Depth mm 840 840 Net Weight kg 10 10 Air filter Washable Washable OUTDOOR UNIT Appearance colour Bronze white (Munsell 6Y7.5/1) Bronze white (Munsell 6Y7.5/1) Height mm 1240 1240 Dimensions Width mm 930 930 Depth mm 385 385 Net Weight kg 103 111 Heat exchange type Finned tube Finned tube Outdoor fan type Propeller fan Propeller fan Air flow volume m 3 /h 6000 6000 Fan motor output 39 + 63 39 + 63 Compressor MODEL RAV-362U-PE RAV-462U-PE ZR49K3-TFD ZR61K3-TFD Output kw 3.0 3.75 Fuse, Crankcase heater, Reverse Fuse, Crankcase heater, Reverse Protective device Phase Protector, Inner overload relay Phase Protector, Inner overload relay Bimetal thermostat Bimetal thermostat Note 1: (ø22) should be used when the length of pipe exceeds 30m. - 6 -

3. CONSTRUCTION VIEWS Space required for service (Space for wiring and piping) Outlet (Space for wiring and piping) When installed with the inlet faced to the wall side When installed with the outlet faced to the wall side - 7 -

4. WIRING DIAGRAM Indoor Unit Outdoor Unit Earth Screw Surge Absorber BLU BLK BLU BLK BLK ORN BLU BLK ORN BLU WHI WHI BLK BLK ORN BLU BLK ORN BLU WHI WHI Power Supply shows terminal block and figures show terminal numbers. Broken lines show wiring at site. Do not operate the units with the magnetic contactor pushed in. * Compressor has internal thermal protection. Symbol Name Symbol Name Symbol Name 63F 1,2 2 Stage Pressure Switch CM Compressor RC01,02 Running Capacitor 43F 1,2 Relay 52C Magnetic Contactor CH Crankcase Heater 26HD Bimetal Thermostat FM UP,LOW Fan Motor (Outdoor) F Fuse (T5A) 47C Reverse Phase Protector - 8 -

5. SPECIFICATIONS OF ELECTRICAL PARTS 5.1 No. Parts Name Type Specifications 1 Compressor ZR49K3-TFD 2 Outdoor unit fan motor 3 Running capacitor for outdoor fan motor SMF-230-63N-3 SMF-230-39N-3 EEP2G405HQA114 AC 400V, 4 µf 4 Magnetic contactor FMCa-1S AC 230V, 50Hz, 5 Pressure switch (2-stage) STB-X602 6 Bimetal Thermostat CS-7 Output (Rated) 3.0kW, 2 pole, 3 phase, 380/415V, 50 Hz Winding resistance 3.73Ω, at 20 C Output (Rated) 63W, 6 pole,1 phase, 230V, 50 Hz Output (Rated) 39W, 6 pole,1 phase, 230V, 50 Hz Tripping pressure 19 kg/cm 2 G, 21 kg/cm 2 G Resetting pressure 13 kg/cm 2 G, 15 kg/cm 2 G Tripping temperature 135 0 C Resetting temperature 110 0 C 7 Crankcase heater AC 240V, 28W 8 Fuse T5A 9 Reverse Phase Protector STR-4AB 5.2 No. Parts Name Type Specifications 1 Compressor ZR61K3-TFD 2 Outdoor unit fan motor 3 Running capacitor for outdoor fan motor SMF-230-63N-3 SMF-230-39N-3 EEP2G405HQA114 AC 400V, 4 µf 4 Magnetic contactor FMCa-1S AC 230V, 50Hz, 5 Pressure switch (2-stage) STB-X602 6 Bimetal Thermostat CS-7 Output (Rated) 3.75kW, 2 pole, 3 phase, 380/415V, 50 Hz Winding resistance 2.91Ω, at 20 C Output (Rated) 63W, 6 pole,1 phase, 230V, 50 Hz Output (Rated) 39W, 6 pole,1 phase, 230V, 50 Hz Tripping pressure 19 kg/cm 2 G, 21 kg/cm 2 G Resetting pressure 13 kg/cm 2 G, 15 kg/cm 2 G Tripping temperature 135 0 C Resetting temperature 110 0 C 7 Crankcase heater AC 240V, 28W 8 Fuse T5A 9 Reverse Phase Protector STR-4AB - 9 -

Indoor unit RAV-362B-PE RAV-362C-PE RAV-362U-PE RAV-462B-PE RAV-462C-PE RAV-462U-PE 6. REFRIGERANT PIPING DIAGRAM Outdoor unit Indoor unit Distributor strainer Heat exchanger Strainer Capillary tube TC sensor Refrigerant pipe (Small side) ø 9.5 mm Refrigerant pipe (Large side) ø 19 mm Packed valve Packed valve Capillary tube Pressure switch Dryer Heat exchanger Strainer Accumulator Check Joint Bimetal Thermostat Compressor Outdoor unit RAV-362B-PE RAV-362C-PE RAV-362U-PE RAV-462B-PE RAV-462C-PE RAV-462U-PE Indoor Unit Capillary IDø2.0 x 400L x 6P IDø2.0 x 300L x 7P IDø2.0 x 300L x 8P IDø2.2 x 200L x 6P IDø2.0 x 200L x 8P IDø2.0 x 300L x 8P Outdoor Unit Capillary IDø2.4 x 500L x 1P IDø2.6 x 700L x 1P - 10 -

7. PERFORMANCE CHARACTERISTICS 7.1 Cooling capacity Capacity Ratio (%) (KW) 8.00 10.00 8.50 10.63 9.00 11.25 9.50 11.88 10.00 12.50 10.50 13.13 11.00 13.75 11.50 14.38 12.00 15.00 Ambient Temp. (Dry Bulb) ( C) -2 ~ Room Temp. (Wet Bulb) ( C) 7.2 Piping length/cooling capacity Cooling Capacity Ratio Outdoor Unit Height H (m) Piping Length (m) The broken line shows in case the piping length is 30m or less. - 11 -

7.3 Piping length/additional refrigerant volume Piping length less than (m) 20 Filled at factory 25 0.25 Additional amount of refrigerant at installation site (kg) 30 0.5 35 0.75 40 1.0 45 1.25 50 1.5 5 3.3 Recharge quantity (kg) 10 15 20 25 3.45 3.55 3.7 3.95 30 4.2 35 4.45 40 4.7 45 4.95 50 5.2 Filled at factory 0.25 0.5 0.75 1.0 1.25 1.5 2.3 2.45 2.55 2.7 2.95 3.2 3.45 3.7 3.95 4.2 The amount of refrigerant put into the outdoor unit at the factory is equivalent to that which fills up 20m length of refrigerant pipe. If the length of refrigerant pipe is 20m or less, addition of refrigerant at the installation site is unnecessary. If the length of the pipe exceeds 20m, add the refrigerant R-22. Overcharge or undercharge of refrigerant in the outdoor unit will cause malfunction of the compressor. The prescribed amount to recharge the unit with refrigerant is shown in the table above. The permissible amount of refrigerant is the prescribed amount + 50g. For and, if the length of pipe exceeds 30m the diameter of the gas pipe must be increased by one rank (i.e. Ø19.0 to Ø22.2). - 12 -

8. EXPLODED VIEWS AND PARTS LISTS Location No. Part No. Description Location No. Part No. Description 1 43A21011 Motor, Fan, SMF-230-63N-3 2 43A21012 Motor, Fan, SMF-230-39N-3 3 43120156 Fan, Propeller 4 43A19001 Guard-Fan 5 43143649 Condenser, Lower () 5 43A43006 Condenser, Lower () 6 43143651 Condenser, Upper () 6 43A43005 Condenser, Upper () 7 43119368 Hanger 8 43162027 Cover, Electric Parts 9 43A41500 Compressor, ZR49K3-TFD () 9 43A41501 Compressor, ZR61K3-TFD () 10 43A60006 Fuse F2 (T5A) 13 43146451 Packed Valve (3/8") 14 43146416 Packed Valve (3/4") 15 43145064 Dryer 16 43148096 Accumulator 17 43155080 Capacitor, Plastic Film 19 43A60005 Terminal, 4P 20 43A60001 Terminal, 4P 21 43154141 Relay 22 43152334 Magnetic Contactor 24 43A49002 Pressure Switch, 2-stage 26 43169584 Surge Absorber 27 43157167 Heater, Crk. Case 28 43146430 Capillary Tube () 28 43146459 Capillary Tube () 29 43150112 Bimetal Thermostat 30 43154148 Reverse Phase Protector STR-4AB - 13 -

PORSHAM CLOSE, BELLIVER INDUSTRIAL ESTATE, PLYMOUTH, PL6 7BP, U.K.