portable gas analyser

Similar documents
portable gas analyser

gas monitoring system

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

IGD.CO.UK

ALTAIR 5X Multigas Detector Product Specification

Dräger X-am 7000 Multi-Gas Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection

MicroRay IR-100 NEW. Inspection MicroRay IR-100

P R O D U C T D ATA S H E E T

Monitores Personales. Personal Monitor

APPLICATION DATA SHEET

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

P R O D U C T D ATA S H E E T

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Automatic Isokinetic Sampler ST5

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

Specifications Minimum Typical Maximum Unit

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

P R O D U C T D ATA S H E E T

Hygrometer / Air Quality Meter

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

ALTAIR 5X Multigas Detector

Two-Channel Gas Controller

Micro III (Models G203, G203S, and G213) Operation Manual

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-TC Thermocouple Data Logger with USB Interface

EAGLE 2X: C155KIT EAGLE 3X: C157KIT

YOUR PARTNER IN FIRE & GAS DETECTION

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Dräger X-am 7000 Multi-Gas Detection

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Dräger Polytron 8000 Stationary gas detector (EC)

SAFESITE Multi-Threat Detection System

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

STATIONARY GAS ANALYSER

Emission Monitoring System

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

GAS ANALYSIS / DETECTION Gas Detector

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Tinytag Ultra Data Logger Manual

ALTAIR 5X Multigas Detector

GAS DETECTION International Gas Detectors CH4 NO

OLC(T) 100 FIXED GAS DETECTOR

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

EL-USB-1-LCD Temperature Data Logger with LCD

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

3SP_H2S_50 Package

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

ELMTEC. Kattreppeln Königslutter / /

ARG 1

MICRO III (G202 / G202s / G212) Single Gas Detector

EL-OEM-3 OEM Packaged Voltage Data Logger

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

3M Oldham OLCT 100. Description. Fixed Gas Detector

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Dräger X-am 5000 Multi-Gas Detection

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Gas Samplers. Compact, user-friendly devices for physically correct gas volume measurements in accordance with the VDI guidelines

Warranty Registration

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

EasyLog Data Logger Series

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Dräger X-am 2500 Multi-Gas Detection

Your competent partner for measuring and services.

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

CEM Istanbul - Turkey. True trace emission monitoring system

Micro IV Operation Manual

G-TECTA TM. Portable Gas Detection Instruments

Model D12-IR. Digital Gas Transmitter...

Gas Detection - GD -

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Pressure measuring instruments

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Danfoss gas detection units

BST-MG01 Single Gas Detecting Alarm Manual Instruction

Danfoss gas detection unit Type GD Heavy Duty

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Technical manual 2G-TA 04 - Gas

FIRST CHOICE CATERING SPARES LTD DIGITAL TECHNOLOGY APRIL 2015 FS

Transcription:

www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting. Datalogger with SD card for storing results and built-in ribbon printer for standard (non-thermal) paper. The GA-60 analyser is offered in two versions: In basic configuration the analyser is not equipped with the gas dryer and works with the probe holder + gas probe pipe. It can be paired with PGD-100 gas dryer with heated hose. Analyser equipped with a built-in NAFION type gas dryer and heated hose - configuration especially recommended for measurement of gases highly reactive with water or disturbed by its presence (SO2, HCl, NO2, Cl2). 1

Equipped with up to 7 electrochemical cells Equipped with up to 3 sensors Built-in 58mm ribbon, graphic printer Built-in rechargeable battery for up to 8 hours of operation (for basic configuration with probe holder + probe pipe) Measurements of gas and ambient temperatures, optionally 8 additional inputs for temperature sensors Additional gas filter with condensate trap (installed in the lid) Differential pressure sensor - for measurements of chimney draft and flow velocity (with help of Pitot tube) Soot measurement programme Analogue outputs (4-20mA / 0-10V) - optional SD card data-logger for saving results Calculations of many additional parameters Firmware for gas calibrations FOR ANALYSER IN A VERSION: Works with standard probe holder and probe pipe Possibility to work with full-size gas dryers (like PGD-100) FOR ANALYSER IN B VERSION: Built-in NAFION dryer with peristaltic pump for condensation removal Driver for heated hose Works with heated hose with built-in heated gas filter and with standard M30x1 fitting, that fits all gas probes with K-type thermocouples FILTER SET FLOWMETER SOOT MEASUREMENT SCALE GAS PROBE L=300MM (EXCHANGEABLE) RS232C CABLE SD MEMORY CARD PROBE HANDLE (HEATED) TEMPERATURE SENSOR SOFTWARE & DOCUMENTS CD 2

ANALYSER VERSION A VERSION B WITHOUT BUILT-IN DRYER WITH BUILT-IN NAFLON DRYER 500 mm * 395 mm * 173 mm Dimensions (W * H * D) Weight (without accessories) 13,7 14,7kg 12,2 13,2kg Casing material Plywood covered with aluminium Operating conditions T: 10 C 50 C, RH: 5% 90% (non-condensing) -20 C 55 C Storing temperature Power supply: Input maximal power consumption 115 VAC or 230 VAC 90 W (without heated hose) Battery: type work time charging time Lead-acid, rechargeable 3x6V / 4,5Ah 16h 12h Data memory: type size number of results SD flash card max 4GB practically unlimited Display Graphical LCD 320 * 240, with variable contrast and backlighting Printer High-speed dot matrix, graphic printer for 2,25 (57,5 ± 0,5mm) normal paper Gas pump gas flow Diaphragm, max 2l/min (with automatic flow control) 90l/h (1,5l/min) Purging pomp for CO sensor Diaphragm, max 1,5l/min RS-232C Communication interface with PC computer Gas filtering Built-in final filter(behind the gas dryer)with replaceable insert 1. Heated filter included in the heated hose 2. Built-in final filter(behind the gas dryer)with replaceable insert BUILT-IN GAS DRYER, HEATED HOSE DRIVER, HEATED HOSE CONCERNS ONLY THE B VERSION (WITH BUILT-IN NAFION DRYER) Dryer type Drying method Based on Nafion exchanger Water transfer through Nafion membrane driven by partial vapour pressure differential - first order kinetic reaction Maximum gas flow for efficient drying 100 l/h Heated hose temperature 120 C electronically stabilised Heated hose temperature hysteresis ~ 5 C Heated hose length 3m (optionally 5m or 10m) Heated hose power consumption 360W (max) Heated hose thermocouple wires K-type (S-type optionally) 3

MEASUREMENTS -10 1000 C 0,1 C Accuracy ± 2 C Time (T90) S-type thermocouple -10 1500 C 0,1 C ± 2 C Tamb - boiler intake air temperature PT500 resistive sensor -10 100 C 0,1 C ± 2 C Differential pressure Silicon piezoresistive pressure sensor -25 hpa +25 hpa 1 Pa (0,01hPa) ± 2Pa abs. or 5% rel. Gas flow velocity Indirect, with Pitot tube & pressure sensor 1 50 m/s 0,1 m/s 0,3 m/s abs. or 5% rel. Lambda λ - excess air number Calculated 1 10 0,01 ± 5% rel. qa - stack loss Calculated 1 100% 0,1% ± 5% rel. Eta η - combustion efficiency Calculated 1 120% 0,1% ± 5% rel. Variable Tgas - gas temperature Method K-type thermocouple Range Resolution Tgas - gas temperature Range Resolution Accuracy Time (T90) Conformity 20,95% 0,01% ± 0,1% abs. or 5% rel., partial pressure 20,95% 0,01% ± 0,1% abs. or 5% rel., partial pressure 25,00% 0,01% ± 0,1% abs. or 5% rel., partial pressure 100,00% 0,1% ± 0,1% abs. or 5% rel. 4 000 ppm 1 ppm 20 000 ppm 1 ppm 10% 0,001% ppm ± 0,005% abs. or 5% rel. Electrochem. with H2 compensation 4 000 ppm 1 ppm 10% 0,01% EN 15058 100% 0,1% ± 0,5% abs. Or 5% rel. EN 15058 5% 0,01% ISO 12039 25% 0,01% ISO 12039 100% 0,1% ISO 12039 Method O2 - OXYGEN CO - CARBON MONOXIDE CO2 - CARBON DIOXIDE 4

Method Range Resolution Accuracy Time (T90) Conformity CH4 METHANE 5% 0,01% 25% 0,01% 100% 0,1% 1 000 ppm 1 ppm EN 50379, CTM-022 5 000 ppm 1 ppm EN 50379, CTM-022 1 000 ppm 1 ppm EN 50379, CTM-022 2 000 ppm 1 ppm EN 50379 5 000 ppm 1 ppm EN 50379 1 000 ppm 1 ppm 70 sec 2 000 ppm 1 ppm ± 10 ppm abs. or 5% rel. 50 sec 20 000 ppm 1 ppm ± 10 ppm abs. or 5% rel. 70 sec Thermal Conductivity Detector 10% 0,1% Thermal Conductivity Detector 25% 0,1% Thermal Conductivity Detector 50% 0,1% Thermal Conductivity Detector 100% 0,1% 250 ppm 1 ppm 60 sec 100 ppm 1 ppm 70 sec N2O - NITRUS OXIDE 2 000 ppm 1 ppm ± 10 ppm abs. or 5% rel. NO - NITRIC OXIDE H2S- HYDROGEN SULPHIDE H2 - HYDROGEN CL2 - CHLORINE HCl - HYDROGEN CHLORIDE CHF3 - FLUOROFORM (REFRIGERANT R23) 2,5% 0,01% SO2 - SULPHUR DIOXIDE 1% 0,01% NO2 - NITROGEN DIOXIDE 1% 0,01% ISO 21258 VOC - VOLATILE ORGANIC COMPOUNDS PIT - Photoionization Detector 100 ppm 1 ppm 120 sec METHOD 21 PIT - Photoionization Detector 1 000 ppm 1 ppm 120 sec METHOD 21 5

STANDARD EQUIPMENT SUPPLIED ALONG WITH THE DEVICE 3m mains cable (type of plug to be selected) Comparison scale with paper filters for the soot test Gas filter with condensation trap and replaceable filter insert (pore size 5µm) Flow indicator Data-logger with 2GB SD card 2,5m RS-232C communication cable with DB9 female connector Software CD with programmes and manuals Quick-couplers for the pressure sensor (2pc.) External ambient temperature sensor (1pc.) ADDITIONAL EQUIPMENT NECESSARY FOR THE ANALYSER TO WORK Probe holder SUITABLE ONLY FOR THE A VERSION OF GA-60 (WITHOUT BUILT-IN DRYER). Together with an exchangeable gas probe pipe the holder is a complete gas probe for extraction of gas samples. It has a single gas tube ended with quick coupler and electric cable ended with a 7-pin connector. Gas probe pipe is mounted with a M30x1 fastening. In the electric connector there is a PT500 sensor for measurement of ambient temperature. Probe holder can be equipped with an in-line filter with a condensation trap (pore size of the filter inlet is 20µm). Probe holder is available in two versions: - heated (with a slit for a filter for soot measurement test), - unheated (without a possibility to perform soot test). Heated hose SUITABLE ONLY FOR THE B VERSION OF GA-60 (WITH BUILT-IN NAFION DRYER). REPLACES THE PROBE HOLDER. Heated hose with heated gas filter supplies gas sample to the analyser s conditioning module. Hose has M30x1 threaded connection to fix gas probe pipe. The other end has magnetic quick coupler and electric connector to connect it to the analyser. Standard length of hose is 3m, it is possible to order other lengths of hoses. Hose is provided with a carrying bag. Gas probe pipe Gas probe is immersed in the gas duct and is supposed to extract the gas sample and to measure its temperature. Exchangeable probes are easily connected to probe holders (with M30x1 fastening). They have thermocouple type K (in some configurations type S) for measurement of gas temperature and a threaded fixing cone. There are many probe pipes available. They differ in length and working temperature. For work efficiency it is advised to own different probe pipes to be able to adjust to the measurement place. 6

OPTIONAL EQUIPMENT & SPARE PARTS Ambient temperature sensor This ambient temperature sensor on a 3m cable is used for measurement of the boiler s inlet air. In basic configuration the ambient temperature is measured by sensor installed in the connector of the gas probe handle. ordering code: Z40P-SENS-TEMP Pitot tube Pitot tube is an accessory that allows to perform measurement of the flow velocity of the gas stream. The measurement is performed indirectly Pitot tube is connected to analyser s differential pressure sensor. Analyser recalculates the differential pressure on the Pitot tube s outlets to velocity. A few lengths of tubes are available. Pitot tube has 2m gas tubings to connect it with the analyser. ordering codes: pitot tube 800mm - Z00-PITOT-8002 pitot tube 500mm - Z00-PITOT-5002 RS232C to USB converter 2.5m cable that allows to connect the analyser (its RS232C port) with USB port in PC computer (especially valuable when PC is not equipped with COM port). ordering code: Z40P-USB-ADAP Bluetooth communication module Module connected to the analyser s RS232C port, allows to communicate with PC computer over Bluetooth protocol. ordering code: Z40P-BLUE-TOOTH 7

FRONT PANEL ELECTRIC & GAS CONNECTORS GRAPHIC DISPLAY (320*240) WITH BACKLIGHTING KEYPAD, 20 KEYS RIBBON PRINTER FOR 58MM PAPER ELECTRIC & GAS CONNECTORS GAS AND ELECTRIC CONNECTORS FILTER SET INLET & OUTLET SD/MMC CARD SLOT POWER SWITCH GAS PROBE SOCKET GAS INLET QUICK GAS-COUPLER FOR HEATED HOSE (WITH MAGNETIC LOCK) A VERSION RS-232C SOCKET B VERSION WITH BUILT-IN DRYER EXTERNAL TEMPERATURE SOCKET DIFFERENTIAL PRESSURE INLETS 8

EXAMPLE PRINTSCREEN EXAMPLE PRINTOUT Temperature stabilizing Please wait... 59 24.78 C 28.53 C 0.54 C / 3min 1 M003 F1 T=2s 0:04 XL1 10:13 CO 22 ppm NO 10 mg/m3 NO2 13 ppm H 2S 12 mg/m3 SO2 220 ppm NH3 160 mg/m3 H2 45 ppm HCl 286 mg/m3 Cl2 15 ppm NO --- --- ppm M+ Operation Serial #: Software: 0 mg/m3 --Print --- mg/m3 Param. 4 M003 CO CO2 Tgas Tamb qa 07499360 0.20 T=2s 0:04 XL1 % CO IR % NO IR C SO2 IR C NOx % 4 www..com 10:13 0 ppm 0 ppm 0 ppm 0 ppm 39 Pdif [Pa] -6-180 M+ F1 0.00 0.00 ------- 9-120 (+) -60 (-) 0 Options