Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Similar documents
Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Ducted Split System Air Conditioners Technical Data

Ducted Split System Air Conditioners Technical Data

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

EC Motor Fan Coil Units. IMD-Y Series l/s

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

Packaged Air Conditioning Custom Build Solutions

EC Motor Fan Coil Units. IMDL-Y Series l/s

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

USER'S OPERATING INSTRUCTIONS

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Heat Pump Air Conditioning Systems

Condensing Units CUS 15-60

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

REVERSE CYCLE DUCTED SPLIT SYSTEMS (ISDL/OSA c/w UC8/IUC) Installation & Maintenance

SAT-3 Room Temperature Controller

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

PAJ3. Product Specifications

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

TOSHIBA AIR CONDITIONING

PRODUCT RANGE: ROOFTOP PACKAGE

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Modular Air Cooled Scroll Chillers

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AQUASNAP JUNIOR 30RHV

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. eco. series. Air Conditioning. Giving you complete control

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

ROOFTOP PACKAGED AIR CONDITIONERS

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

LZA High efficiency air to water heat pumps with HP compressor

Product Brochure Smart Power. Low Profile Ducted

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Brochure 2017

MAC N-407 Air-Cooled Chiller

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Hitachi Inverter Wall Split Air Conditioning

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Ducted inverter reverse cycle air conditioning

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Now with WiFi as standard Find out more at

Hi - Wall Split Systems 12K - 18K - 24K

TOSHIBA AIR CONDITIONING

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

Remote Air Cooled Condensers C2 Series

Air Cooled Packaged Units

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

World s best airconditioning

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

MACH N-407 Heat Pump Air-Cooled Chiller

Water Cooled Air Conditioners Applications Manual

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

DESIGN & TECHNICAL MANUAL

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

WJH4 Product Specifications

R4H4. Product Specifications

designed for air conditioning australian living

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

MAC-120HE-03 Air-Cooled Chiller

LZT High efficiency air to water heat pumps with E.V.I. compressors

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Hansol Hi Wall Inverter Heat Pump

TECHNICAL SPECIFICATIONS

Transcription:

Ducted Split System Air Conditioner Technical Data ISD 184KY / OSA 184RKTV SEPARABLE INDOOR UNIT OPTION Optional SAT Controller High Efficiency EC Motor Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 18.4 kw SEPTEMBER 2012

ISD 184K / OSA 184RKTV DUCTED Split System AIR CONDITIONER General The ISD indoor unit, together with its associated OSA outdoor unit, provides a reverse cycle (heat pump) split system air conditioner designed and developed to comply with AS/NZS 3823 specified conditions. The system has been tested and proven for cooling operation in outdoor temperatures up to 50 C. Applications These units have been specifically developed for air conditioning of light commercial and residential premises, e.g. offices, motels, shops and homes. Air Flow Selection If the air returning to the indoor coil is regularly expected to be above 50%RH, then the coil face velocity should be limited to be 2.5 m/s or less (for reference 2.0 m/s is marked on the graph below). High humidity levels can occur in tropical or subtropical conditions, and/or when heavily moisture laden fresh air is introduced. Consideration must always be given to selecting an air flow and face velocity that avoids water carry-over problems. Applications using full or high proportions of fresh air should be referred to your nearest temperzone sales office to establish the correct selection of units. Features Refrigerant R410A. Each complete system uses refrigerant R410A which is deemed to have zero ozone depletion potential. User Friendly. The air conditioning system is available with an optional SAT Controller. This thermostat has been designed to maintain a high level of comfort for room occupants. Emphasis has been placed on providing controls that are easy to use despite the sophisticated microprocessor system that runs it. Use of the Auto and Timer function settings allows you to "set it and forget it". Efficient. Indoor units include a high efficiency electronically commutated (EC) motor. Each outdoor unit incorporates a high efficiency rotary compressor. Heat exchange coils use inner grooved (rifled) tube for better heat transfer. Performance. A dynamically balanced forward curved fan with a multi-speed EC motor enables fine tuning of the indoor unit to match the supply air requirements. These EC motor fans have a fully integrated speed control that enables soft starting. Fan speed can be stepped to your own requirements or continuously variable using a 0 10V DC control signal. The system includes a temperature sensing head pressure control which enables the system to compensate for outdoor ambient temperatures below 20 C on cooling cycle, and above 15 C on heating cycle. Separable. The indoor units are separable for ease of installation through small man holes minimum 550 mm sq. clear aperture. It may be desireable in some applications to keep the two separate parts of the unit apart and joined by ducting, eg over a ceiling joist. A pair of the optional Spigot Plate Adaptors are available to facilitate this option. Quiet. Each integral high efficiency EC motor can vary from zero to full speed. This allows slow ramp up with no sudden noise change. The motor can be controlled to have the best air flow for the ducting and requirements as well as used for de-humidifying the space. The outdoor units' coil design permits low fan speeds and hence low noise levels. The compressor is isolated in a built-in, insulated compartment to minimise noise. The indoor unit is also insulated for noise attenuation. Slimline. The compact up-right design of the outdoor unit requires only a 150 mm gap on the coil side where installation is against a wall. Its slimline cabinet is particularly practical where there is restricted space, e.g. side access pathways, balconies, narrow ledges, etc. Durable. The outdoor coil fins are epoxy coated for extra protection in corrosive environments, e.g. salt laden sea air. The outdoor unit's cabinet is constructed from high grade galvanised steel - polyester powder coated (grey) for all weather protection (IP 45). External fasteners are stainless steel. Heat exchange coils comprise aluminium plate fins on mechanically expanded rifled copper tube. The indoor unit's cabinet is constructed from high grade galvanised steel and also includes a plastic drain tray for complete corrosion resistance. Service Access. The indoor unit's built-in drain tray can be removed for ease of cleaning and service accessibility. Insulation. Closed cell foam insulation has been used in the indoor unit's cabinet to ensure no particles are introduced into the air stream. The insulation is foil faced and meets fire test standards AS 1530.3 (1989) and BS 476 parts 6 & 7. Control Option. Commissioning is made easier when the EC motor to be controlled variably (within a restricted range) by a 0 10 volt DC signal that can be supplied either by a BMS system, a sophisticated controller or temperzone's optional TZT-100 Controller. The optional Signal Isolator will be required for continuously variable speed control applications. Self Diagnostics. The Unit Controller (UC) has a display of LEDs to indicate faults and running conditions. A non-specific fault indicator is included for interface to external systems. Optional Equipment Outdoor Unit: 1. Anti-vibration mounts (rubber) 2. Drain connection - right angle Indoor Unit: 1. temperzone SAT Controller (or TZT-100 Controller for digital versions). 2. Spring Mounting Kit. 3. Spigot Plate Adaptors Double Inlet (for use when separating indoor unit) Ø450 mm 4. Signal Isolator (Item no. 201-000-129) for using EC motors in a 0 10V DC continuously variable speed mode. SAFETY FEATURES 1. HP and loss of refrigerant protection. 2. Anti-rapid cycle timer and internal overload for compressor protection. 3. Circuit breaker control circuits. 4. Time-and-temperature controlled electronic de-ice switch prevents icing up of the outdoor coil during heating cycle. 5. Frost protection on cooling cycle. 6. Sensor fault indication. 7. Compressor minimum run time to ensure oil return. 8. 24V control circuit. Compressor Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration. Refrigeration Piping The standard unit allows for a line length up to 60 m. For line lengths between 60 m and 90 m, refer to temperzone's Split Systems Installation Guide (refer www.temperzone.biz/technical Support). Maximum line length when extended is 90m. Max. height separations between units are: Outdoor unit above indoor unit : 20 m Outdoor unit below indoor unit : 20 m. The OSA 184 is shipped from the factory with a charge of HFC-410A (R410A) refrigerant sufficient for a 10 m line length. Liquid and suction service valves are provided. Accurator expansion devices control the flow of refrigerant. The matched indoor unit is shipped with a holding charge of nitrogen. Both units have brazed pipe connections. Wiring The electrical supply required (including voltage fluctuation limits) is: 3 phase 342 436 V a.c. 50 Hz with neutral and earth. The compressor crankcase heater requires a 24 hour power supply. A control panel, with 24V control circiuit, located in each outdoor unit, is fully wired ready to accept the main power supply. Each system conforms with emission standards EN 55014-1, EN 60335-1 and EN 60335-2-40. Digital Version: Digital Scroll Compressor. The digital version of this unit provides a variable capacity ability that enables closer control of room temperature. This is achieved by avoiding on/off cycling of the compressor. These compressors have proven very reliable because of their design simplicity. Electrical harmonic noise is very low. Extended Capability. Digitals are particularly suitable for applications requiring full or high proportions of fresh air, VAV, close control and supply air temperature control. The manufacturer operates a quality management system that conforms to AS/NZS ISO 9001:2008.

SAT CONTROLLER (Optional) Features Summary Cool / Dry / Fan modes. Heat / Auto modes Auto / High / Medium / Low fan speed selection. Temperature setting range from 16 C 30 C. LED to indicate status of the unit [Power On/Off]. Room temperature display. Real time clock. 7 day timer two start and/or stops per day On demand countdown run timer, up to 9 hours. Auto-Restart or No Restart after power failure. Continuous or Intermittent selection of fan run-on in dead zone. Backlit screen for ease of reading; changes colour for each mode. Soft touch tab keys Battery backup (Lithium). Sleep function. Zone Control up to four zones. Audible beep to acknowledge key entry or wireless remote control. Low voltage control cable. Colour: white and light grey (Keypad - gold and blue). Optional: Infra Red Remote controller Remote return air sensor, Extended interface lead, Zone Control board, Zone Control transformer 220/240V to 24V ac, 65VA. Extra Wall Control plaque. PERFORMANCE DATA Cooling Capacity (kw) Total = Total Capacity (kw) Sens. = Sensible Capacity (kw) E.A.T. = Entering Air Temperature = Nominal Capacity (kw) Note: Capacities are gross and do not include allowance for fan motor heat loss. Capacities are for close coupled systems. Interconnecting pipework will reduce capacity. MODELS INDOOR INDOOR COIL OUTDOOR COIL ENTERING AIR TEMPERATURE C D.B. FAN E.A.T. Indoor Outdoor AIR D.B. W.B. 23 27 31 35 39 43 SPEED Unit Unit l/s C C Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. 21 15 18.0 14.2 17.8 14.2 17.3 14.0 16.5 13.5 15.4 12.8 14.0.8 23 17 19.0 13.9 18.7 13.9 18.2 13.7 17.4 13.3 16.3 12.6 15.0.7 ISD 184K / OSA 184RK HIGH 1020 27 19 19.9 16.0 19.7 16.0 19.2 15.7 18.4 15.3 17.3 14.5 15.9 13.5 31 21 20.9 18.9 20.7 18.9 20.1 18.7 19.3 18.1 18.3 17.3 16.9 16.2 Indoor Air Flow Correction Factors @ nominal conditions Indoor Air Flow (%) -20% -10% Rated +10% Total Capacity 0.95 0.975 1.0 1.025 Sensible Capacity 0.89 0.950 1.0 1.050 PIPE LENGTH CAPACITY LOSS ON Cooling Cycle Due To Pressure Drop Note: Loss percentage is approximate only. No allowance made for vertical piping. Performance Loss per additional 10m beyond first 5m. 2.1 % 4.0 % Suction Pipe Size OD 22 mm 19 mm Additional Pipe Length to allow per Bend Long 90 Radius (2 x pipe dia.) 0.50 m 0.42 m

PERFORMANCE DATA heating capacity (kw) G = Gross Heating Capacity kw, based on nominal air flow of 1300 l/s. N = Net Heating Capacity kw allowing for average defrost. = Nominal Capacity (kw) MODELS Indoor Outdoor Unit Unit ISD 184K / OSA 184RK INDOOR ENTERING AIR TEMP. C D.B. 15 20 25 outdoor coil ENTERING AIR TEMPERATURE (e.a.t.) c d.b. 5 3 1 1 3 5 7 9 G n G n G n G n G n G n G n G n.7 10.6 12.7.4 13.6 12.1 14.5 12.4 15.3 13.1 16.5 15.6 17.5 17.5 18.4 18.4.5 10.4 12.5.2 13.3.8 14.2 12.2 15.0 12.9 16.1 15.3 17.2 17.2 18.0 18.0.1 10.0 12.0 10.8 12.8.4 13.6.7 14.5 12.3 15.5 14.6 16.5 16.5 17.4 17.4 AVAILABLE EXTERNAL PRESSURE (Pa) 250 200 150 100 50 l/s - Pa 1300 RPM 1000 RPM 900 RPM 00 RPM 1200 RPM - - - - l/s - W 1300 1.2 1200 1.0 00 0.8 900 1000 0.6 0 700 800 900 1000 00 1200 AIR VOLUME (l/s) 2.5 m/s Face Velocity 0.4 0.2 INPUT (kw) AIR HANDLING Note: Airflows are for a dry coil. Reduce airflow by 10% in high moisture removal conditions. In a free blow application, beware of exceeding indoor fan motor's full load amp limit. Air flows given are for ISD units without filter installed. If using EU-2 filter media, provide 0.08 m 2 face area per 100 l/s of airflow to maximise efficiency. Optional Polypropylene Net Filter Media (clean): Coil Face Velocity (m/s) 1.5 2.0 2.5 Pressure Loss (Pa) 5 9 13 SOUND LEVELS Indoor Unit - Supply Air Outlet FAN SPEED 900 RPM 1000 RPM 1200 RPM SWL db(a) 68 72 76 Sound Power Levels (SWL) Test Conditions: BS 848 PT2 1985. Installation Type A (free inlet and outlet). Direct method of measurement (reverberant room). Measured in decibels re 1 picowatt. OCTAVE BAND FREQUENCY Hz 125 250 500 1 k 2 k 4 k SOUND POWER LEVELS (SWL) db 71 64 63 62 61 58 75 69 67 67 65 63 76 71 70 71 69 67 Sound Pressure Levels (SPL) Within A Room Deduct the room absorption effect below from the Sound Power Levels (SWL) above to obtain Sound Pressure Levels within a room. Note: Occupant at least 1.5 m from sound source. ROOM TYPE SOFT MEDIUM HARD 125 4 3 0 250 8 7 1 OCTAVE BAND FREQ. Hz 500 1k ROOM ABSORPTION EFFECT 8 3 9 4 2k 9 4 4k 9 5 Outdoor Unit MODEL OSA 184V FAN SPEED HIGH SWL db(a) 66 OCTAVE BAND FREQ. Hz 125 250 500 1 k 2 k 4 k SOUND POWER LEVELS db 67 65 64 62 59 51 SPL @ 3 m db(a) 50 OCTAVE BAND FREQ. Hz 125 250 500 1 k 2 k 4 k SOUND PRESSURE LEVELS db 51 49 48 46 43 35 Sound Pressure Level (SPL) in decibels re 20 µpa.

DIMENSIONS (mm) PROJECTION ISD 184KY Indoor Unit Not to Scale 35 1496 1433 FIXED MTG CTRS 1287 Separable for ease of installation through small man holes minimum 550 mm sq. clear aperture COIL SIDE 645 FIXED MTG CENTRES 648 OPTIONAL SPRING MTG CENTRES REFRIG. CONN S ELECTRICAL BOX FAN SIDE OPTIONAL SPIGOT PLATE ADAPTORS Ø450 mm (x2) ACCESS PANEL 1095 30 FIXED MTG CTRS 94 60 ELECTRICAL BOX 135 60 20 REFRIG. CONN S 145 425 OA 355 262 1470 17 DRAIN 19 OD SAFETY DRAIN 16 OD 785 OA 50 OPTIONAL FILTER BOX OSA 184RKTV Outdoor Unit 150 MIN. CLEARANCE Recommended Pipe Line Sizes Liquid: 13 mm OD Suction: 19 or 22 mm OD Note Materials and specifications are subject to change without notice due to the manufacturer's ongoing research and development programme. 150 MIN. CLEARANCE 710 2000 MIN. CLEARANCE ACCESS PANEL 1270 30 ID ELECTRICAL CONDUIT HOLES 722 MTG CTR 760 REFRIG. CONN'S 20 25 ID DRAIN HOLES 82 203 1067 MTG CTR 12 DIA. HOLE + SLOT 205 1475 25 ID DRAIN HOLES

SPECIFICATIONS System Indoor Unit : ISD 184KY Outdoor Unit : OSA 184RKTV * 6 Nominal Cooling Capacity * 1 kw 18.4 Net Cooling Capacity * 1 kw 17.81 EER / AEER (cooling) 3.24 / 3.22 Heating Capacity * 2 kw 17.2 COP / ACOP (heating) 3.51 / 3.49 Air Flow * 3 l/s 1290 Sound Levels * 4 Power Source * 5 Finish Weight (net/shipping) kg Indoor Unit (SWL) on Med. 72 Outdoor Unit (SPL) 50 3 ph. 415 V a.c. 50 Hz Indoor Fan Maximum Current A 8 Running Amps (Total System) A/ph. 14 / 8 / 8 Max. Running Amps (Total System) A/ph. 16 / 10 /10 Refrigerant HFC-410A (R410A ) Maximum Vertical Separation m 20 Maximum Standard Line Length m 30 Maximum Extended Line Length m 60 Pipe Sizes (Suction/Liquid) mm OD 19 or 22 / 13 Indoor Unit Outdoor Unit zinc galvanised steel grey polyester powder coat Indoor Unit 95 / 6 Outdoor Unit 205 / 240 Notes: * 1 Nominal Cooling Capacity (gross) at AS/NZS 3823 conditions: Indoor Entering Air Temperature 27 C D.B., 19 C W.B.; Outdoor Entering Air Temperature 35 C D.B. * 2 Heating Capacity at AS/NZS 3823 conditions: Indoor Entering Air Temperature 21 C D.B.; Outdoor Entering Air Temperature 7 C D.B., 6 C W.B. * 3 Supply air flow at Nominal Cooling Capacity conditions stated above. * 4 Sound Levels are measured at nominal cooling capacity conditions stated above. SPL measured at 3m from unit. * 5 Voltage fluctuation limits: Single phase systems 200 252 V; Three phase systems 342 436 V. * 6 Digital compressor version OSA 184RKTGV. Available from temperzone limited Head Office, Auckland : 38 Tidal Rd, Mangere, N.Z. Private Bag 93303, Otahuhu, NEW ZEALAND. Email sales@temperzone.co.nz Website: www.temperzone.biz temperzone australia pty ltd Head Office, Sydney : 14 Carnagie Place, Blacktown, NSW 2148 PO Box 8064, Seven Hills West, NSW 2147, AUSTRALIA. Email sales@temperzone.com.au AUCKLAND SYDNEY Ph. 0-9-279 5250 Ph. (02) 8822-5700 Fax 0-9-275 5637 Fax (02) 8822-57 WELLINGTON ADELAIDE Ph. 0-4-569 3262 Ph. (08) 8340-0607 Fax 0-4-566 6249 Fax (08) 8340-28 CHRISTCHURCH SINGAPORE Ph. 0-3-379 3216 Ph. SNG 6733 4292 Fax 0-3-379 5956 Fax SNG 6235 7180 MELBOURNE Ph. (03) 8769-7600 Fax (03) 8769-7601 BRISBANE Ph. (07) 3308-8333 Fax (07) 3308-8330 NEWCASTLE Ph. (02) 4962-55 Fax (02) 4961-5101 PERTH Ph. (08) 9314-3844 Fax (08) 9314-3855 TOWNSVILLE Ph. (07) 4773-9566 Fax (07) 4773-9166 HOBART Ph. (03) 6331-4209 Fax (03) 6333-0224 09/12 Pamphlet No. 3829a temperzone limited 2012