DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

Similar documents
LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Carbon Monoxide Transmitter

Temperature Controllers

Installation, Operating and Maintenance Manual

Multi-Gas-Controller MGC2

PTE0705 Electric Fence Monitor

Model 17A00 Expansion Enclosure

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

TECHNICAL DATA OBSOLETE

F500 Elite. FIELDBUS ADAPTER. Watchdog NTC to Modbus RTU communications. (Software Version 3.3.0)

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

DMFPM-2R MULTIFUNCTIONAL

Public Safety DAS Annunciator Panel

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Gas Detection System TOX ALARM DG2000-Garage

DE20 INSTRUCTION MANUAL

ALARMLINE ANALOGUE Linear Heat Detection System

Product Data Sheet. Remote Terminals. Features:

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

20 Light Remote Annunciator

Danfoss gas detection units

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

21-light Remote Annunciator. Owner s Manual

Duct and Rough Service Carbon Monoxide Sensor

MO n : 12JMC rév A

Heat Sensor Cable Alarm Units DT650L / DT950L

Linear Heat Detection

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Danfoss gas detection unit Type GD Heavy Duty

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

SACE PR021/K SIGNALLING UNIT

AlarmLine Linear Heat Detector

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

CTT8 TEMPERATURE MONITOR DEVICE

Intelligent addressable fire alarm control panel

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

System 800 Addressable Fire Detection & Alarm System

F4 Process Controller Installation and Operation Guide

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

Added password for IP setup page : Password must be in IP format!

Process & TeMPerATUre UniversAl input DigiTAl MeTers

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

EXTINGUISHING AGENT RELEASE MODULE

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

WIO500 and WIOI500 Water in oil sensor

AlarmLine Addressable Linear Heat Detector

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Excel-EN Conventional Fire Control Panel

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

RS485 MODBUS Module 8AI

ECO N DATE DESCRIPTION OF CHANGE CHG

LCF Touch Modbus Datasheet Application Security Advice Caution

Interface Modules for SENTRI

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

Two-Channel Gas Controller

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Remote NAC Power Supply D7038

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

JK e-solutions ApS FS12. Control and Monitoring system for Fixed Aerosol Fire Extinguishing Systems. Installation and Service Manual R11

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

An introduction to... Sigma

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

FEC400 Series. Installation Manual

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

5000 INSTALLATION GUIDE

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

FieldServer FS Secutron

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Operating Instructions. For. Alarm Control Module. Model SSR 500

SCAN200E USER S MANUAL

FireNET Plus Wiring Instructions

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

FLT93 Installation, Operation and Troubleshooting Guide

Intelligent Security & Fire Ltd

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Clamp-on ultrasonic flow and energy meters for liquids

4100U City and Relay Cards Installation Instructions

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Transcription:

LST Digital Interface Monitor Module (LST-DiMM) MAN3109

TABLE OF CONTENTS: Page No. 1 Important Guidelines... 3 2 General Description... 4 Digital Interface Monitor Module... 4 3 Specifications... 5 Leader Cable... 5 Mounting Dimensions... 5 Static Discharge Cautionary... 6 4 Installation... 7 Connections Diagram... 7 5 Operating Modes Wiring Diagram Independent... 7 6 Operating Mode Wiring Diagram Interlock... 8 7 Commissioning... 9 8 Two-wire RS-485 Modbus RTU Communications... 10 9 Resetting the Ampac LST DiMM Unit... 11 MAN3109-Rev 1 Page 2 of 11

1 IMPORTANT GUIDELINES Please read this instruction leaflet thoroughly before commencing installation. Install the Digital Interface Monitor Module (LST DiMM) accordingly to meet local and country installation requirements. The LST DiMM must be installed in accordance with NFPA 70 & 72, NEC 760 (National Electric Code) and Authorities Having Jurisdiction. Ensure the product is installed, commissioned and maintained by persons according to good engineering practices and who received sufficient training on the unit. Only use Ampac LST Digital Linear Heat Detection cable with the LST DiMM. Test the Linear Heat Detection Cable before connecting it to the LST DiMM using a multimeter. Ensure the end of line resistor (1kohm) is securely connected at the end each linear heat detection cable. If only one zone is required leave the end of line resistor (1kohm) connected across the terminals of the unused zone. Ensure any cable glands used are tightened to form a secure and moisture proof seal around the detection cable and any other cable in or out of the unit. Do not exceed the maximum operating voltage of the LST DiMM (36Vdc) Do not connect lengths of linear heat detection cable in T connections or spurs. MAN3109-Rev 1 Page 3 of 11

2 GENERAL DESCRIPTION Digital Interface Monitor Module The Ampac LST Digital Interface Monitor Module (LST-DiMM) is a dual zone module for monitoring up to two zones of Ampac LST digital Linear Heat Detection (DLHD) Cable. If an overheat or fire situation triggers either zone of the DLHD cable the unit automatically calculates and displays the distance along the cable, in feet and metres, to the alarm point. The two zones can operate independently of each other, or in interlock mode and a separate alarm and normally conducting fault output are provided for each zone. The unit is intended to be installed between the Digital Linear Heat Detection cable and a conventional or addressable fire alarm control panel. It has power, fault and alarm lights, as well as volt free outputs for fault and alarm, corresponding to each zone. It may also be connected to a industrial process control system using the two wire RS-485 Modbus RTU output. Figure 1: Typical Installation of the LST Digital interface Monitor Module MAN3109-Rev 1 Page 4 of 11

3 SPECIFICATIONS Part No Description LST DiMM (-M suffix M16 knockouts on bottom) (-Pg suffix PG16 knockouts on bottom) LST Digital Interface Monitor Module (LST-DiMM) Revision 1.5 Enclosure Dimensions Rating Finish Display Approvals Power Requirements Operating Voltage H180mm x W120mm x D60.5mm (H7.1in x W4.72in x D2.38in) NEMA 4, 4X (IP65) Light Gray with clear lid 2 line, 16 character backlit display showing zone status UL 864 10th ed All circuits power limited if powered from a power limited supply 12Vdc - 36Vdc Current Consumption Normal Operation (standby) Alarm Operating Temperature Range <12mA <4mA <40mA <15mA -20 C +50 C (-4 F +122 F) Terminal Blocks Spacing Wiring Wire Size 5mm Rising Clamp 16A 0.08mm2 (28AWG) to 4mm2 (11AWG) Supervised Circuits Power, Input Zone 1 & Input Zone 2 Inputs Max Zone Strength Min Zone Strength End of Line Resistor Short Circuit Current Max Voltage Ground Fault Impedance Up to two Class B zones of Ampac LST Digital LHD Cable 3000m (10,000ft) 1m 1kohm (included) 0.5mA 5V 0ohms Outputs Communications Sounder Alarm Fault T wo wire RS-485 Modbus RTU (field wiring limited to the same room to comply with UL listing) 2.4kHz 92dBa @ 10cm Buzzer 2x Form C volt-free relay contacts (resistive, common) Max V Max Current Max Switching Power 30Vac or 42.4Vdc 2A 60W, 62.5VA 2 x Optoisolated phototransistor output (resistive, common) Max V Max Current Max Power Dissipation 35Vdc 80mA 150mW MAN3109-Rev 1 Page 5 of 11

Leader Cable Mounting Dimensions The LST DiMM can be connected via leader cable to the start of the Linear Heat Detection cable. During installation the voltage drop across the leader cable is calibrated out to give an accurate distance reading when an alarm is triggered (see page 9 for calibration procedure). The maximum length of leader cable that can be used per zone is dependent upon the cable diameter. The following is a guideline for typical cable sizes and maximum length: Cable Size 20AWG (16x0.2mm or 0.8mm dia, copper) 22AWG (7x0.25mm or 0.6mm dia, copper) 24AWG (7x0.2mm or 0.5mm dia, copper) Max Leader Cable Length 1000m 600m 390m Static Discharge Cautionary The following items are cautionary notes that will help prevent equipment damage or malfunction caused by static discharge: CAUTION Static charges produce voltages high enough to damage electronic components. Follow these precautions when installing, servicing, or operating the LST-DiMM: Work in a static-free area. Discharge any static electricity you may have accumulated. Figure 2: Mounting Dimensions for the Ampac LST DiMM Discharge static electricity by touching a known, securely grounded object. Do not handle the printed circuit board (PCB) without proper protection against static discharge. In the event that the LST-DiMM malfunctions after encountering a static discharge correct operation of the unit can be restored by interrupting power to unit for a brief period (approximately 10s). Setup information can be verified by following the steps in the installation procedure section. In the event of the setup information being corrupted the unit should be reset following the Resetting the LST-DiMM procedure MAN3109-Rev 1 Page 6 of 11

4 INSTALLATION The LST DiMM allows accurate location of an alarm point along a length of Ampac LST Digital Linear Heat Detection (DLHD) cable. It continuously monitors up to two zones of DLHD cable for a fault (open circuit) or an alarm (overheat or fire condition). Because of the wide range of applications that digital Linear Heat Detection cable can be used for, it may not always be possible, or be too time consuming, to locate where along the cable an alarm has occurred. Using the LST DiMM, when an alarm occurs the distance to the overheat condition is immediately calculated and displayed on the integrated display. Connections Diagram Figure 3 shows the connections diagram for the LST DiMM unit. The unit is provided with a 1kohm end of line resistor in each zone input. If only one zone is required, leave the 1kohm resistor connected across the zone which is not in use. Otherwise the 1kohm resistor should be connected at the end of the Digital Linear Heat Detection cable. If a fault is detected, the corresponding fault output stops conducting, triggering a fault at the fire alarm control panel. If an alarm is detected, the corresponding alarm output changes state, triggering an alarm at the fire alarm panel. The fault outputs also stop conducting on power loss to the unit or microprocessor fault, triggering a fault at the fire alarm control panel. The two wire RS-485 Modbus RTU output also outputs the current state of both zones. See the section RS-485 Modbus Communications for more detail. There are two primary configurations of the LST DiMM (see figure 1): 1) The DLHD cable can be connected directly to the LST DiMM 2) The DLHD cable is connected to a length of leader cable which is connected to the LST DiMM. In this scenario the leader cable must be calibrated out during commissioning of the LST DiMM. Figure 3: Wiring Diagram for the Ampac LST DiMM 5 OPERATING MODES WIRING DIAGRAM INDEPENDENT There are two operating modes for the Digital interface Monitor Module: 1. Independent This is when the LST DiMM is used as a two zone system. When a fault or overheat condition occurs on an LHD zone, the corresponding fault or alarm output respectively is triggered. The two zones operate independently and both sets of outputs should be connected to a fire alarm control panel. If the zone is not required leave the 1kohm resistor in the zone input terminals as supplied. In this mode, the two zones can either contain identical rated temperature LHD cables or two different rated temperature LHD cables, e.g. a 68 deg C in zone 1 and a 105 deg C in zone 2. MAN3109-Rev 1 Page 8 of 11

6 OPERATING MODES WIRING DIAGRAM INTERLOCK 2. Interlock this mode is for applications which require a fail-safe guarantee that an alarm is only triggered when an overheat condition has been detected. This mode may also be known as coincidence detection. In this case, the same rated temperature LHD cable should be attached to both zones of the DiMM. The alarm output is only activated when both LHD cables trigger an alarm due to an overheat condition. If one LHD cable zone input registers an alarm but the second does not, the alarm output will not be activated. This is to prevent an alarm if a mechanical or other issue has triggered one LHD cable and not an overheat condition. MAN3109-Rev 1 Page 8 of 11

7 COMMISSIONING 1. After wiring the unit up (see wiring diagram) power up the device. Device will show screen including software revision number. 2. If the unit is being setup for the first time the following options will be shown. If the unit has previously been installed the display will automatically cycle through the options, showing the stored settings. 3. Select the operating mode. (see Operating modes (pages 7-8) for more detail. Independent: the two zones operate independently of each other (default). ww Interlock: Both fault outputs activate when a fault occurs on either zone 1 or zone 2. Both alarm outputs activate only when both LHD zones trigger an alarm. 4. Select the cable type connected to Zone 1 (68 C/78 C/88 C/105 C/185 C) 5. Select the cable type connected to Zone 2 (68 C/78 C/88 C/105 C/185 C) 6. If leader cable is connected between the linear heat detection cable and the LST-DiMM for this zone, press the Select button and select Yes. Press the Set button to continue. 7. The controller will then ask if the zone is ready to be calibrated. The leader cable must be connected to the LST-DiMM and shorted out at the end where it connects to the START of the LHD cable. Once this is done press the Set button. 8. The DiMM will display the voltage drop across the leader cable. Remove the short from the leader cable and connect it to the START of the LHD cable as normal. 9. If the Linear Heat Detection cable is connected directly to the LST-DiMM then select No and press the Set button to continue. 10. Select whether you would like the alarm outputs for both zones to be latching. If set to Yes, then if an alarm is triggered the unit will either require the power supply to be interrupted (min. 10s) or the Set button to be pressed to reset to normal once the alarm conditioned has been cleared. 11. Select whether the Modbus RTU output should be enabled. If this is not enabled then proceed to step 17 12. Set the Modbus RTU address of this unit. (1-247) 13. Cycle through the possible Baud Rates for the Modbus RTU output. (1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200). 14. Select the number of data bits for the Modbus RTU output. (7 or 8) 15. Select the number of stop bits for the Modbus RTU output. (1 or 2). 16. Select the parity for the Modbus RTU output. (even/odd/none). 17. Once the unit has been commissioned the display will show the zone status. In normal operation the display will show OK for each Zone. In Interlock mode the display will show {Zone 1: OK {Zone 2: OK to indicate the zones are linked and an alarm is only transmitted if both zones are triggered. 18. If an alarm condition occurs the DiMM automatically calculates the distance along the cable to the trigger point and first displays this value in metres. 19. The display alternates showing the distance along the cable to the trigger point in metres and in feet. 20. If a fault occurs (open circuit) on the Linear Heat Detection Cable the display will show FAULT on the corresponding line. 21. If a ground fault occurs on either zone the display will show a GND FAULT on the corresponding line. LST Dual ZoneDiMMR1234 Operating Mode INDEPENDENT Z1CableType 68C Zone Cable Yes Ready to Calibrate Zone2cal 109mW Zone Cable No Latching Outputs No Modbusoutputon Yes Modbusaddress 1 BAUDRATE 1200 DATABITs 7 StopBITs 1 PariTY Even Zone10K Zone20K Zone1534m Zone20K Zone1534m Zone20K Zone10K Zone2FAULT Zon10K Zone2GNDFAULT MAN3109-Rev 1 Page 9 of 11

8 TWO-WIRE RS-485 MODBUS RTU COMMUNICATIONS The Ampac LST DiMM includes a two wire RS-485 Modbus output which can be enabled to output the status of each zone of Digital Linear Heat Detection Cable. The DiMM Modbus output supports the Modbus RTU protocol and the following functions: Function code 4 (Read Input Registers) The request for reading the input registers should be constructed in the following manner: Address for firs register to be read 916-bit) Number of registers to read (16-bit) The DiMM will respond in the following manner: Number of bytes of register values to be read (8-bit) Register values (16-bits per register) The DiMM stores the information for each zone of the DLHD cable in the following format: Register Description Possible Values 0 Zone 1 status 1 Zone 2 Status 2 Zone 1 Cable Type 3 Zone 2 Cable type If the start address plus the requested number of registers exceed 4, the DiMM will return an IL- LEGAL DATA ADDRESS error. If the request contains a function code other than those supported the LST-DiMM will return an ILLEGAL FUNCTION error. MAN3109-Rev 1 Page 10 of 11

9 RESETTING THE AMPAC LST DiMM UNIT WARNING: This procedure will erase ALL stored settings and reset the Ampac LST DiMM unit back to its factory default state. The cable types, leader cable calibration, latching output selection and Modbus setup will all require selecting after this procedure. To reset the LST DiMM unit back to the factory state, when the unit is powered up and in normal operation (see step 15 in the Commissioning procedure), press and hold the SET and SELECT buttons for a minimum of 10 seconds continuously. While the SET and SELECT buttons are held down the power LED will flash quickly to confirm this procedure is about to take place. After approximately 10 seconds, the unit will restart and return to step 1 in the Commissioning procedure. Ampac LST Digital LHD Cables by Part No Refer to LST Digital Linear Heat Detection Installation Instructions and LST LHD Application Guide for more information on installation and uses. Part No Description 4114-1001 LST Digital LHD 68 C PVC 4114-1101 LST Digital LHD 68 C Nylon outer sheath 4114-1201 LST Digital LHD 68 C Polypropylene outer sheath 4114-1301 LST Digital LHD 68 C Stainless steel outer braid on PVC 4114-1002 LST Digital LHD 78 C PVC 4114-1102 LST Digital LHD 78 C Nylon outer sheath 4114-1202 LST Digital LHD 78 C Polypropylene outer sheath 4114-1302 LST Digital LHD 78 C Stainless steel outer braid on PVC 4114-1003 LST Digital LHD 88 C PVC 4114-1103 LST Digital LHD 88 C Nylon outer sheath 4114-1203 LST Digital LHD 88 C Polypropylene outer sheath 4114-1303 LST Digital LHD 88 C Stainless steel outer braid on PVC 4114-1004 LST Digital LHD 105 C PVC 4114-1104 LST Digital LHD 105 C Nylon outer sheath 4114-1204 LST Digital LHD 105 C Polypropylene outer sheath 4114-1304 LST Digital LHD 105 C Stainless steel outer braid on PVC 4114-1105 LST Digital LHD 185 C Nylon outer sheath 4114-1305 LST Digital LHD 185 C Stainless steel outer braid on Nylon UNCONTROLLED DOCUMENT NOTE: Due to AMPAC s commitment to continuous improvement specifications may change without notice. MAN3109-Rev 1 Page 11 of 11