THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

Similar documents
LAB EQUIPMENT DETAILS

REFRIGERATION TUTOR. OBJECTIVE: To perform test on the refrigeration tutor to determine different COPs and other performance parameters.

LISTOF EXPERIMENTS. S. No. NAME OF EXPERIMENTS PAGE No.

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Mechanical Heat Pump R515

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Vapour Jet Refrigerator / Heat Pump R853

Refrigerator/Heat pump

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

OFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.)494005

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

(2) 325 tpd York Chlorine Liquefier Systems

Technical Development Program

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Air & Water Heat Pump R832

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

CHAPTER 3 EXPERIMENTAL SETUP AND PROCEDURE

College of Technological Studies Department of Power & Refrigeration Technology. Course Contents

PACKAGE AIR CONDITIONER

Use this Construction/HVAC Glossary to answer the questions below.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

In the name of God. Jami Institute of Jami - Mehdi Rasti

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

T P A 120 S 4 S N 1 Y

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Installation, Start-Up and Service Instructions

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

ME 354 THERMODYNAMICS LAB THE REFRIGERATION CYCLE

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Energy Use in Refrigeration Systems

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

SAMPLE STUDY MATERIAL

PAJ3. Product Specifications

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Experimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Homework Chapter2. Homework Chapter3

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Installation, Start-Up and Service Instructions

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Improvement Of Energy Efficiency Ratio Of Refrigerant Compressor

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

American International Journal of Research in Science, Technology, Engineering & Mathematics

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Global Journal of Engineering Science and Research Management

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Chilled Water DOAS Fan Powered Terminal Units

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

(ME-225) HEATING, VENTILATION AND AIR-CONDITIONING SYSTEM

Visit us at For the latest technical information,

LYODEL FREEZE DRYING SYSTEMS

SECTION AIR COMPRESSORS AND ACCESSORIES

1. General Description

Commercial High-Efficiency Condensing Units

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

MAC N-407 Air-Cooled Chiller

REFRIGERATED AIR DRYERS

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Installation, Operation, and Maintenance Information

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

Pressure Enthalpy Charts

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

MACH N-407 Heat Pump Air-Cooled Chiller

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Transcription:

AIM: THERMAL ENGINEERING LABORATORY II To train the students with principles and operation of thermal Engineering equipments. OBJECTIVES: To experimentally analyze conduction, convection and radiation. Performance study on fins, heat exchanger, refrigeration and air conditioning systems are included. LIST OF EXPERIMENTS: HEAT TRANSFER: Thermal conductivity measurement by guarded plate method Thermal conductivity of pipe insulation using lagged pipe apparatus Natural convection heat transfer from a vertical cylinder Forced convection inside tube Heat transfer from pin-fin (natural & forced convection modes) Determination of Stefan-Boltzmann constant Determination of emissivity of a grey surface Effectiveness of Parallel/counter flow heat exchanger REFRIGERATION AND AIR CONDITIONING LAB: 1. Determination of COP of a refrigeration system 2. Performance test on single / two stage reciprocating air compressor 3. Performance test in a HC Refrigeration System LIST OF EQUIPMENTS : 1. Guarded plate apparatus 1 No. 2. Lagged pipe apparatus 1 No. 3. Natural convection-vertical cylinder apparatus 1 No. 4. Forced convection inside tube apparatus 1 No. 5. Pin-fin apparatus 1 No. 6. Stefan-Boltzmann apparatus 1 No. 7. Emissivity measurement apparatus 1 No. 8. Parallel/counter flow heat exchanger apparatus 1 No. 9. Single/two stage reciprocating air compressor. 1 No. 10. Refrigeration test rig 1 No. 11. Air-conditioning test rig 1 No.

AATTE201 REFRIGERATION TEST The experimental refrigeration cycle test rig (AATTE201) consists of a compressor unit, condenser, evaporator, cooling chamber, controlling devices and measuring instruments. The coefficient of performance of refrigeration plant is given by the ratio of heat absorbed by the refrigerant when passing through the evaporator or the system, to the working input to the compressor to compress the refrigeration. Flooring area: 6 x3 Electrical power supply SPECIFICATIONS: Plant Capacity: 50 Kg of Ice in 24 Hrs, In Blocks Hermetically Sealed Compressor: 1/2 Hp Cap. Air Cooled Condenser: 1/2hp, 12 X 13 X 2 Rows Fan Motor with Blade: 1/35 Hp Expansion Device: Thermostatic Expansion Valve (10 To -40 Degc) Rotameter: 0.6 To 62 Lph (Eureka) Filter Drier: Dm-50(Dan Foss) Energy Meter: 2.5 5 Amps Hermetically sealed compressor fitted on stand Power input through thermostatic switch Minimized vibrations RANGE OF EXPERIMENTS: To determine COP of the refrigeration system

AATTE202 SINGLE/TWO STAGE RECIPROCATING AIR COMPRESSOR Single stage Air Test Rig (AATTE202) consists of single cylinder, piston & reservoir tank driven by A.C. motor. Thermometers are provided at inlet and outlet. To find out the inlet volume of air an Orificemeter is provided. Pressure Gauge is provided at reservoir tank. Safety valve and auto switch is providing for the safety factor. Flooring space: 3 x3 3-ⱷ Electrical power supply SPECIFICATIONS : Model Free Air Delivery cfm lpm Working Pressure Kg/cm2 psig Motor Power Rating HP kw Tank Capacity Litres TS10120 H 30 835 cfm lpm 12 175 Kg/cm2 psig 10 7.5 HP kw 250 420 500 HP12250 22 623 cfm lpm 25 350 Kg/cm2 psig 12.5 9.3 HP kw 250 500 Lubrication necessity minimized Can work under robust conditions RANGE OF EXPERIMENTS: Volumetric efficiency of an Air Compressor. Isothermal HP of Air Compressor (Single Stage). To calculate the compression ratio. To plot the graph of the following characteristics o Isothermal Horse Power Vs Delivery Pressure o Compression Ratio Vs Delivery Pressure o Volumetric Efficiency Vs Delivery Pressure

AATTE203 AIR-CONDITIONING TEST RIG The AC test Rig consist of 1.5T sealed compressor unit, a finned condenser (heating coil) and evaporator (cooling coil), a double ended (shaft) motor to run fan and blower simultaneously and fitted on a wooden stand and properly covered by grill. A duct is assembled along with blower unit as a carrier of comfort air, the velocity of the air passing through the coil is measured by using a pitot tube fitted in duct itself and connected to V-tube manometer which is fitted on control panel. Floor spacing: 5 x3 3-ⱷ Electrical power supply SPECIFICATIONS: Supply: 220-240 Volts, 50Hz, 1 Phase. Input power: 1.0kW. Rated current: 4.5 Amps. Operating switches: Main switch & Piano type switches for compressor and heater Pressure gauge: 0-300 psi Suction gauge: 30-0-150 psi Rota meter 0-5 L L PM Fan blower motor: 1/30 HP 1-0 Condensor & Evaporator: Double row finned Refrigerant : R-22 Nomenclature Dimension ( L X B X H ) Specifications 500 X 420 X 500mm Motor 1/2 hp AC, 230V, 3F 12mm. RANGE OF EXPERIMENTS : Minimum Equilibrium Position HC AC performance tests Max Equilibrium Position 115 mm. To calculate the compression ratio. Arm length To plot the graph of the following characteristics Resolution of linear measurement 0.5mm. o Compression Ratio Vs Delivery Pressure U-110mm, L- 175mm. Central load(hartnell) 1kg. o Volumetric Efficiency Vs Delivery Pressure

AATTE204 PARALLEL/COUNTER FLOW HEAT AATTE204 consist of concentric tube that exchanger, the hot fluid (i.e. hot water) is obtained form an electric geyser and it flows through the inner tube. The cold fluid is cold water and can be admitted at any one of the ends enabling the heat exchanger to run as a parallel flow apparatus or a counter flow apparatus. This can be done by operating the different values provided. Temperatures of the fluids can be measured using thermometers. Flow rate can be measured using stop watch and measuring flask. The out tube is provided with adequate asbestos rope insulation to minimize the heat loss to the surroundings. Floor spacing: 5 x3 3-ⱷ Electrical power supply Stopwatch Measuring tape Thermometers (0 o to 100 o ) SPECIFICATIONS: Length of Heat Exchange 1.6 m Outer lite material G.I. ID. - 30mm O.D. - 35mm Inner tube material - Copper O.D, 15mm Thermometers - 0 to 500C - 2nos.10 to 1000C - 2nos Geyser - Instantaneous type. 3 kw capacity - 1 no. Measuring flask - 1000 with stop clock Lubrication necessity minimized Can work under robust conditions RANGE OF EXPERIMENTS: Effectiveness of Parallel/counter flow heat exchanger

AATTE205 HEAT TRANSFER FROM A PIN-FIN APPARATUS Extended surfaces of fins are used to increase the heat transfer rate from a surface to a fluid wherever it is not possible to increase the value of the surface heat transfer coefficient or the temperature difference between the surface and the fluid. The use of this is variety of shapes Circumferential fins around the cylinder of a motor cycle engine and fins attached to condenser tubes of a refrigerator are a few familiar examples. It is obvious that a fin surface sticks out from the primary heat transfer surface. The temperature difference with surrounding fluid will steadily diminish as one moves out along the fin. The design of the fins therefore required knowledge of the temperature distribution in the fin. The main objective of this experimental set up is to study temperature distribution in a simple pin fin. Floor spacing: 5 x3 Electrical power supply SPECIFICATIONS : Duct width b = 200 mm Duct height w = 120 mm Orifice dia. do = 20 mm Orifice co-efficient cd = 0.6 Fin length L = 16cm Fin diameter df = 12mm (Characteristic length) RANGE OF EXPERIMENTS: To study the temperature distribution along the length of a pin fin in natural & forced convection. To calculate Gr, Pr & Nu number in natural conviction. Calculate Re, Pr & Nu number in forced conviction.

AATTE206 DETERMINATION OF STEFAN-BOLTZMANN CONSTANT Stefan Boltzman law which establishes the dependence of integral hemispherical radiation on temperature. We can verify this phenomenon in this unit. The experimental set up (AATTE206) consisting of concentric hemispheres with provision for the hot water to pass through the annulus. A hot water source is provided. The water flow may be varied using the control valve provided, thereby to control the hot water temperature. A small disk is placed at the bottom of the hemisphere, which receives the heat radiation and can be removed (or) refitted while conducting the experiment. A multi point digital temperature indicator and thermocouples (Fe/Ko) are provided to measure temperature at various points on the radiating surface of the hemisphere and on the disc. AATMT Floor spacing: 5 x3 3-ⱷ Electrical power supply (EQUIPMENT NAME) SPECIFICATIONS : Mass of the disc = 0.005 kg. Dia. of the disc = 0.020 m. Material of the disc Cp = copper = 381 J/KgK Easy understanding of phenomenon of heat transfer by radiation. IMAGE Determination of Stefan-Boltzmann constant. Built in timer for temperature readings at constant time intervals. Digital temperature indicator. RANGE OF EXPERIMENTS: Determination of Stefan Boltzmann constant Study of effect of hemisphere temperature on the constan

AATTE207 FORCED CONVECTION INSIDE TUBE When saturated vapor flows in a tube that is cooled by an exterior fluid, some of the vapor condenses on the tube wall and forms a liquid film. Condensation inside tubes occurs in many applications, particularly in refrigeration condensers. The main resistance to heat transfer for refrigerants and other low-conductivity fluids is the resistance to conduction through the condensate film. AATTE207 consisted of a closed-loop refrigerant flow circuit driven by a mechanical-sealed rotor pump. An electrically heated boiler generated vapor which passed through a flow meter and into the test section. Eletricity supply: 1 phase, 220 v Ac, 10 Amp. Floor area of 1.2 m*0.5 m SPECIFICATIONS : Internal diameter of the tube 5 mm External diameter of the tube 6 mm Tube thickness 0.5 mm Tube Material Stainless steel Thermocouple material Chromiumaluminum Tube length 900 mm Tube thermal conductivity 16.28 W/m C Insulator thickness 50 mm Insulator thermal conductivity 0.043 W/m C AC Volt meter 0 to 5 V AC Ampere meter 0 to 70 A Forced convection pipe material: Copper tube with thermocouple points, heater to heat the pipe. Centrifugal blower to pass the air with air flow controller. Temperature indicator with thermocouples, voltmeter, ammeter, heat controller, and monometer are all mounted on control panel table...

AATTE208 NATURAL CONVECTION HEAT TRANSFER FROM A VERTICAL CYLINDER AATTE208 consists of a vertical brass pipe heated by a cartridge heater inside. The pipe looses heat to atmosphere by natural convection. It is fitted in an enclosure to provide undisturbed natural convection currents. Thermocouples are attached on the pipe to measure local temperatures. Heater input is measured on voltmeter and ammeter. Thus students can determine overall heat transfer coefficient and local heat transfer coefficients in natural convection at various heat transfer rates. Floor spacing: 5 x3 Electrical power supply SPECIFICATIONS : Pipe - Brass pipe, 40 mm. dia. (OD), 600 mm. Long, fitted with cartridge heater inside. Thermocouples are fitted along the length of pipe for temperature measurement - 7 nos. Enclosure 300 mm. x 300 mm. x 900 mm size with one side of perspex sheet. Measurements & Controls: A dimmer stat for heater input control. Voltmeter and Ammeter for heater input measurement. Multi channel digital temperature indicator. RANGE OF EXPERIMENTS : To determine the overall heat transfer coefficient at the surface of a given vertical metal cylinder by the natural convection method. To determine the value of Nusselt number.

AATTE209 THERMAL CONDUCTIVITY OF PIPE INSULATION USING LAGGED PIPE APPARATUS Lagging of pipes is required to prevent leakages of heat. AATTE209 is designed to study the lagging phenomenon. In Lagged pipe Apparatus, three concentric pipes are arranged between two supports. The gaps between the pipes are filled compactly by two different insulating materials and heater is provided at the centre of inner pipe. Temperature at various points is measured with Temperature Indicator. Heat input is measured by Voltmeter - Ammeter. The assembly is mounted on angle frame. Ammeter Voltmeter Thermocouple Temperature indicator SPECIFICATIONS: Pipes : M.S. Pipe Inside - 5 cm dia approx. M.S. Pipe Middle -10 cm dia approx. M.S. Pipe Outer -15 cm dia approx. Length of Pipes - 1m approx. Control panel consisting of Voltmeter -0-100/200 volts. Ammeter - 0-2 Amp. Dimmer stat for heater, 0-230 V, 2 Amps. Digital Temperature Indicator, 0-300 C with least count Nichrome Nomenclature cartridge heater of suitable Specifications capacity and length Dimension ( L X B X H ) 500 X 420 X 500mm Motor 1/2 hp AC, 230V, 3F Study of the concept of double & single lagging. Minimum Equilibrium Position 12mm. study of effects of different insulating material Max Equilibrium Position 115 mm. Combinations. Arm length U-110mm, L- 175mm. Electrical input control & measurement with Resolution of linear measurement 0.5mm. Complete panelized instruments. Central load(hartnell) 1kg. Digital Temperature Indicator.

AATTE210 THERMAL CONDUCTIVITY MEASUREMENT BY GUARDED PLATE METHOD Guarded hot plate is a widely used and versatile method for measuring the thermal conductivity of insulations. Although the specimens are often rather large, this usually presents no difficulty. A flat, electrically heated metering section surrounded on all lateral sides by a guard heater section controlled through differential thermocouples, supplies the planar heat source introduced over the hot face of the specimens. The most common measurement configuration is the conventional, symmetrically arranged guarded hot plate where the heater assembly is sandwiched between two specimens. In the single sided configuration, the heat flow is passing through one specimen and the back of the main heater acts as a guard plane creating an adiabatic environment. Thermocouple Temperature indicator SPECIFICATIONS: Central Heater of suitable capacity, with 100mm to 150mm dia sandwiched between two copper plates Ring guard heater of suitable capacity with 30mm to 150mm width sandwiched between two copper plates Cooling chamber with water circulation arrangements, Specimen 6 to 20mm thick, 180rnm to 200mm dia. Digital voltmeter range of 0-300 volts AC Digital Ammeter range of 0-20A AC Digital Temperature Indicator 0-400 degree centigrade