FoamFatale INTRODUCTION OF A NOVEL HIGH END TECHNOLOGY FOR LARGE ATMOSPHERIC STORAGE TANK FIRES. TFEX 1 Ltd.

Similar documents
Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Foam Products ENGLISH

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

Fire protection on chemical manufacturing sites

Fire Prevention Systems

CORTEC. CORTEC

ONE SEVEN FAST. EFFECTIVE. SAFE. ENVIRONMENTALLY FRIENDLY

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

SECURITY BLANKET Foam Fire Protection Products

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

automatic FiReFighTing SYSTeMS in PainT booths

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Element C3.4 Fire Fighting Equipment

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Aerosol Type Fire Extinguisher Aerosol Type Fire Extinguisher

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

Fire Risk Assessment

Explosion Protection Engineering Principles

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

Oxeo extinguishing systems

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

SUPPRESSION SALES I INSTALLATION I SERVICE

AUTOMATIC FIRE EXTINGUISHING SYSTEM for TUNNEL PROTECTION with SPREAD REMOTE CONTROLLED MONITORS (TUDEM-LEGIO)

Ceasefire Watermist Hydrant Systems

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

Vancouver Airport Fuel Delivery Project. Fire Prevention, Preparedness and Emergency Response

FIRE SAFETY. This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are:

Fire fighting Questions

Mist-Tech Fire Fighting Equipment

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

Creating a safer world!

Before you begin. Introduction About construction work 1. Topic 1 How health and safety laws apply to you 3

WSU-TFREC Fire Safety Training

ecodry Figure 1 - Process Diagram ecodry B General Process Description

CBD-11. Fire and the design of buildings

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

Level 2 Award in Fire Safety (QCF) (SCQF Level 5 in Scotland) Unit 1 title: Fire safety principles

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

"USING FIRE EXTINGUISHERS"

& Fire Extinguisher Training

Risk Management Department. Fire Extinguishers

THE BURNING ISSUE FOR BODYSHOPS

Fire Protection. A Health and Safety Guideline for Your Workplace. Introduction. Fire Prevention and Control. Workplace Assessment

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

VARIO CARBON TECHNOLOGIE AG VARIO VARIOCARBON CARBON HIGH - PERFORMANCE FIREFIGHTING SYSTEMS

Tel Web: dyayan.com

Recycling Plants. Tönsmeier Wertstoffe GmbH & Co. KG. Stationary fire protection. Case Study

Fire and Gas Detection and Mitigation Systems

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

LEARNING SPECIAL HAZARD DETECTION TYPES

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

Carbon Monoxide Safety Information

Technical Article. Foam Systems - Low Expansion, Medium Expansion, High Expansion. Martin Workman, Product Manager Special Hazards Division

Special Occupancy Requirements

Boiler Basics. Design and operation

C 319/6 Official Journal of the European Union

In the event of a halt in operations, the economic detriment to client and own business is in addition to the significant risks of consumer supply

RIM SEAL SYSTEMS E-BOOK

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

THE IDEAL SOLUTION FOR KITCHENS

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Foam Solutions, LLC Performance Parkway, Columbus, Ohio Ph ; Fax

FlameRanger. Revolutionary Firefighting Robot.

Management Practices: Fire Protection Impairments November 2015

SAFETY THE BEST FOR YOUR EQUIPMENT

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

Water Mist Fire Suppression System protecting the electrically powered shredder and the ballistic separator at an MRF in Devon

Using Fire Extinguishers. Leaders Guide and Quiz

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

AIRCRAFT RESCUE AND FIREFIGHTING

Chapter 3 FF II Fire Department Communications

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

Operating Instructions

Risk Management of Fire using Video Based Detection

Nessie High Pressure Water Mist Components for Fire Fighting

POLY extinguishing systems. The high-performance, unique, and versatile extinguishing system for initial, effective fire fighting.

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2018/C 092/02)

Summary. firefighter training in Since that time the firefighter had attended semi-annual

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 126/02)

Delhi Metro System. Emergency and Fire Safety Measures in. - by Sanjeev Kumar & Kailash Chandra Joshi. Fire Protection & Safety

Transcription:

INTRODUCTION OF A NOVEL HIGH END TECHNOLOGY FOR LARGE ATMOSPHERIC STORAGE TANK FIRES TFEX 1 Ltd.

FoamFatale technology makes it possible to make a huge step forward in protecting the environment against the damaging effects of storage tank fires Abstract The highest level of protecting the environment is provided by successful prevention. The primary environmental effect is caused by the fire itself. In addition to the value of the material destroyed by the fire, the environment as such, our common treasure, also suffers. In the majority of cases the combustion products are highly damaging to our health. By burning fossil fuels the composition of the atmosphere changes, since carbon stored for millions of years in solid or liquid form is again released into the atmosphere in the form of carbon dioxide gas. And since uncontrolled fires always result in incomplete combustion all kind of by-products are also released into the atmosphere. The secondary environmental effect is caused by the use of extinguishing materials. The use of very large quantities of firewater can cause environmental damage when the, always, polluted water use cannot be properly collected afterwards and subsequently treated before it is released into the environment. The use of artificial extinguishing materials always causes environmental pollution. The level of pollution, i.e. the secondary environmental effect depends largely on the quality of the extinguishing material used and on the application technology, because these two factors define the quantity of the material necessary to extinguish a given fire. And depending on the degree and speed of natural decomposition of the used extinguishing materials into harmless components the period the environment is under strain is determined. We call a fire fighting technology environmentally friendly when it uses only natural extinguishing materials (water and gases, like nitrogen or argon, which are extracted from air). 2

We call a technology environmentally aware when it uses artificial (but not hazardous) materials for the extinguishment, but when compared to other technologies the application will result in: the shortest period of time between outbreak of the fire and extinguishment. highly efficient and effective use of extinguishing agent. Setting up and managing proper fire protection facilities on hydrocarbon storage facilities operating under extreme conditions nearly always requires a non-traditional approach. The traditional method is not suitable when there are no firewater sources available. Examples are sites operating a substantial part of the year under very low ambient temperatures, but also storage sites in arid desert areas. Other examples are mobile military fuel storage facilities, which have no access to a high performance firewater network. In some cases the owner has no choice but to opt for operating without any fire protection whatsoever. In very low temperature situations it would be prohibitively expensive to build, maintain and operate firewater networks with heated reservoirs and pipelines. Such facilities are typically required when using the traditional fire protection methods as recommended by e.g. NFPA. Completely new foam-making and foam application method was developed, which fully solves the firewater-related problems described above. This is the FoamFatale technology. The automatic and autonomous Self Expanding Foam system responds immediately after the ignition, and does not require any external supply of water or energy to operate. It is considered to be representative of the Best Available Technology today. The fire surface is totally covered in maximum two minutes from the ignition, thus there is no time for the development of environmentally dangerous smoke or soot, and a major part of the stored material is also saved. 3

Contents 1. Conventional strategies, reason for low success rate. 5 Foam proportioning 5 Foam generation 5 Dependence on water 5 Conclusion 6 2. Description of the new high performance fixed system 7 Preparation of foam 7 Dimensions of SEF vessels 7 Let s the foam expand 7 Operation of the system 8 Advantages of the SEF system over a conventional system 8 Applications where the SEF concept can be used 8 Tank fire extinguishing by superintensive foam flooding 8 Advantages of the SEF system over conventional systems 10 Live fire test 11 4

1. Conventional strategies, reason for low success rate. The conventional strategies apply foam with mobile, semi-fixed and fixed equipment. Foam proportioning The foam concentrate has to be proportioned into the water. The operating range of the proportioning equipment is always limited. The range giving an acceptable deviation from the set point is even more limited. The response of the proportioner to quick flow variations is, generally speaking, not very good. Proportioning systems range from very simple and not very reliable systems to electronically controlled sophisticated and complicated, but therefore also vulnerable, devices. Foam generation To make expanded foam it is necessary to entrain air into the foam solution stream. Venturi-type aspirating devices are typically used for this purpose. Proper functioning of such a device is determined by the delicate balance between flow rate, upstream pressure and backpressure. Optimum performance can only be achieved in a rather narrow operating range. Blockage, or partial blockage, of the small-bore air inlet often occurs in fixed systems in locations where maintenance is not optimal. This results in malfunctioning. Dependence on water In conventional foam systems (including the CAFS too) the availability of firewater is essential. A number of steps are required to convert foam concentrate, water and air into expanded foam. The expanded foam can subsequently be applied onto the burning surface. In the majority of cases these activities take place close to the scene of the fire. Quite a team of trained manpower is required to set up these relatively complicated systems. In view of the stressful situation during any fire, mistakes are likely to be made resulting in mal-performance of the system. 5

Unmanned storage sites cannot count on turnout of sufficient fire-fighters within a reasonable period of time. Over the past decades, the user had no choice but to accept these complicated and expensive systems. Sites that had no access to adequate water were left without protection. The owners/management, the Fire Administration and the Environment Protection Authorities had no choice but to accept the situation. Conclusion There are sites where: The implementation of conventional fire protection systems is facing serious technical problems. The cost to set up an installation complying with NFPA recommendations is too high. There is insufficient manpower available at short notice to operate a labour-intensive mobile or semi-fixed system. There is a need for an acceptable level of reliability. 6

2. Description of the new high performance fixed system A method has been developed which eliminates the limitations of conventional systems. The concept of this new system is that perfectly prepared foam is stored under pressure in a vessel. On release of the foam from the vessel, expanded foam is formed at the location where the expansion takes place. The patented system is called Self-Expanding Foam system, abbreviated as SEF. Preparation of foam Self Expanding Foam is prepared well in advance under calm and controlled conditions. This eliminates the probability of an off-spec composition of the foam. The pre-mixed foam is stored in a pressure vessel until the moment of use. The foam remains homogenous for at least 10 years, as experience has shown. Dimensions of SEF vessels Static SEF vessels can be very large. The maximum quantity of stored foam is determined only by the mechanical manufacturing limitations. The maximum size of vessels on vehicles is determined by size and weight. The limiting factor is most probably the maximum allowable dimension of the vehicle as well as the maximum allowable axle load for the road system to be used. Let s the foam expand On release of the SEF the pressurized foam will expand. This in turn eliminates the need for aspirating devices. The release rate of the foam from the vessel is not bound by conventional limitations, like aspirating devices and such. The expansion ratio of the foam is independent from the flow rate; the pressure in the foam vessel is the only factor determining the expansion. 7

Operation of the system The operation of the whole system is extremely simple. All that is required is to open the isolation valve between the pressurised SEF storage vessel and the foam application device. The simplicity eliminates the need for specialists to operate the system successfully. Advantages of the SEF system over a conventional system Requires no manpower resources to set up and operate at the scene of the fire. Is so simple that mistakes are unlikely. The foam is mixed under calm and controlled conditions, and is 100% consistent. Does not require any aspirating devices. Does have an unlimited flow range. Produces optimum quality foam at all flow rates. Has only a few critical elements requiring regular inspection. Requires considerably lower capital investment. Requires considerably lower maintenance effort and cost. Applications where the SEF concept can be used Hydrocarbon storage tank fire fighting by superintensive foam flooding New concept airport crash tenders First intervention vehicles Skid mounted units Fixed installations for restaurant cookers, fuel storage, underground fuel bunkers, Portable and wheeled fire extinguishers. SEF tanks on vehicles, replacing or complementing conventional fire fighting vehicles. Foam supply on sites handling flammable liquids that have no firewater system. Foam supply for road car loading facilities handling flammable liquids. Tank fire extinguishing by superintensive foam flooding FoamFatal is a revolutionary new tank fire extinguishing technology, using a very high foam application rate. It is called Superintensive Foam Flooding (SFF). 8

The extremely high foam flow rate is provided through the new foam application device, which accommodates the very large foam flow and prevents excessive velocities in the nozzle. It is called Continuous Linear Nozzle (CLN). The CLN provides an ideal curtain-like foam application pattern, thus providing substantial and continuous cooling of the tank wall. One of the advantages of the Self Expanding Foam concept is that it has no release rate limitations. By combining the SEF method with the newly developed high capacity CLN, it is easy to achieve the application rates of 20-40 litres/minute/square meter. The result of this combination is an extremely high efficient system. Tests carried out on a 500 m 2 gasoline tank on fire repeatedly resulted in extinguishment in less than 40 seconds. The reliability of the system is very high; the valve is the only moving part in it. The SEF storage vessel can be a stationary vessel located in the vicinity but at a safe distance from the hydrocarbon tank. An alternative option, requiring some intervention by manpower, can be a mobile SEF storage vessel mounted on a truck. continuos linear nozzle heat detector foam header self expanding foam Foam introduction devices main valve protection wall Foam supply devices Figure 1. Principle of tank fire protection by SEF 9

Advantages of the SEF system over conventional systems Its reliability level is very high: the CLN can hardly be damaged by explosions or fire. It is sabotage-proof, the fire protection system of a tank farm built by our method has no common elements, like a fire water system, which when destroyed would cause the malfunction of fire protection systems using firewater. Requires considerably lower capital investment. Requires considerably lower operating cost. The system is fully autonomous. Does not require firewater at all. It does not require external energy sources, like fire truck or electric pump. It is so simple that mistakes under stressful fire conditions are unlikely. Automatic operation of the system further reduces air pollution caused by the fire. Its simplicity eliminates the need for specialists to operate and maintain the system. It uses perfectly proportioned foam, mixed under calm and controlled conditions. The foam is stored under pressure; no pump or other pressure-raising source is required. The pressure of the container determines the expansion; no aspirating device is required. Produces optimum quality foam at all flow rates. Its flow rate is virtually unlimited; pumps, proportioners, aspirating devices are not there. Very high foam-producing rates can be easily achieved at modest cost. Has only a few key elements requiring regular inspection. Is also suitable for the fire protection of rooms or large equipment and machinery. 10

Live fire test A test tank was built by TFEX Engineering Co. Ltd. The tank was used for experiments with flow rates and types of nozzles ultimately resulting in the current mature system. Live tests on this 500 m 2 gasoline fire repeatedly demonstrated that after 40 seconds, the fire went out so abruptly as if it had been cut off. An automatic version of such a system will extinguish very large tank fires such as this within one to three minutes from the moment of ignition, without intervention from any person. 11

TFEX Ltd. www.tfexltd.com