Power Blocks - Splicer/Distribution

Similar documents
Marathon Special Products

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

Application. Specifications. Finish

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Performance Data. curus Component Recognized; File No. E IP 20

Molded Case Circuit Breakers, Bulletin 140G

Introducing Hermaphroditic Blade and Receptacle Connector

RACK-MOUNT Air Conditioners

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Two Circuit Heavy Duty Burner Connector

Arrow Hart hospital grade self-test GFCI receptacles

DETECT-A-FIRE Heat Detectors

Arrow Hart specification grade GFCI receptacles

ACCESSORIES GUIDE. RobroyEnclosures.com. Market-Leading Non-Metallic Enclosure Brands

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Gfci Self Test Duplex 20A 125V WH

Bulletin 855T 70 mm Control Tower Stack Lights

AF/GF dual-purpose receptacles

GENESIS Indoor Air Conditioners

Agency Certifications, Recognition and Approvals

Oil & Gas Industry. Magnecraft Relay Solutions

new new Industrial plugs and sockets

SPECTRACOOL Indoor & Outdoor Air Conditioners

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

Thermostat Catalog 2004

Products :: Circuit Protection :: Thermal Circuit Breakers

BULLETIN 600 SINGLE PHASE

Jan05 Rev A EC

CURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

SM CONNECTOR. 1Certified LR R Specifications. Standards. 2.5mm pitch/disconnectable Crimp style wire-to-wire connectors

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

GROUND FAULT PROTECTION PANELs. the power to protect GPD/GPFJ TYPES GPD, GPFJ, GPAD AND GPAFJ

Agency Certifications, Recognition and Approvals

Tamper & Weather Resistant Receptacles

Flexible Heaters W A T L O W. Temperature Sensors and Controllers SERIES EHG

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

BEHIND THE PANEL AML s simple, cost effective design provides many behind-panel benefits for the designer and installer/user.

SPECTRACOOL Indoor & Outdoor Air Conditioners

Electric Duct Heaters

MICRO SWITCH NT Series

Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Stacking Height mm inch

MICRO SWITCH NT Series

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

IEC Lighting Contactor Specifications

Zero Superheat Control

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Helically wound resistance wire coil made

Electronic Control Pushbutton

Overload relays. General descriptions. Configuration of the front

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

S1L Series: Metal Bottom

Top-Mount Air Conditioners

Fire Sprinkler Freeze Protection Design / Install Guide

Two-Position Electric Duplex Room Thermostats

Essentials Series 4.0

Introducing SlimSeal SSL Connector

Standard Product. Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

36T. Bimetal Disc Controls & Limits. Introduction

MICRO SWITCH Limit Switch Comparison

Dimensions (111mm) (111mm) 3 (76mm)

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

59T, 66T Series Electric Water Heater Controls

PART GENERAL 1.01 SECTION INCLUDES

Description. Construction

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

DIESEL Engine Fire Pump Controllers Features

Water separators MS-LWS, MS series

Plug-in Base, Long Range Sensor E3B2

KUH. Horizontal Unit Heater. Applications. Description

Oakton TEMP 9500 Advanced Multiparameter Controller

Immersion Heaters. Screw Plug Immersion Heater

3099-2E. Technical Information

ASCO Series 185 Power Transfer Switches

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

Enclosure Heaters and Fan Heaters

Oakton TEMP 9000 Advanced Thermocouple Controller

Construction. Electrical. Enclosure Protection IS19 - Industry Standards UL Recognized Type 3, 3R, 4 & 12 IEC IP56

XP Series Non-Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof

Installation Instructions

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

Project Name. Date. Cat. Number. Type

Table of Contents. Protective Relays

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

TROPO 15W Dimmable LED Driver

Guide to Hazardous Location Approvals:

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

SDL4 LED Strip Diffused Lens

Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

BAS SDL8' LED Strip Diffused Lens

TC-5231 Series, TC-5232, & TC-5241 Series

PANELBOARD PROTECTION ON A GLOBAL SCALE

5300, 5300CH, 5300EX, 5300FN

QA(13) - Series Miniature Circuit Breakers

PROAIR Harsh Environment/Wash Down Air Conditioners

Installation Instructions

Transcription:

POWER BLOCKS Power Blocks - Splicer/Distribution Electrical 60-2280 amps 600 volts AC/DC (UL) Flexible stranded wire compliant Multiple wire rating - refer to data sheets for details Listed products provide feeder circuit terminal spacing Standards See chart for product specific approvals listed UL listed - or - UL recognized Listed file no. QPQS.E309401 (UL 1953) Recognized file no. XCFR2.E62806 (UL 1059) CSA certified file no. LR19766 (CSA C22-2 No. 158) CE (Component IEC 60947-7-1) RoHS compliant (All) Mechanical Base, black thermoplastic or phenolic (see chart) temp-ratings Thermoplastic: 125 0 C (257 0 F) - UL RTI Phenolic: 150 0 C (302 0 F) - UL RTI Flammability, UL 94 V-0 Mounting: panel mountable, 132 series is also DIN mountable Accessories (consult customer service) Covers - see page 24 for series cover specifications Marking strips - available with custom printing Printing - consult factory for custom requests See on-line data sheets for: Dimensional drawings Detailed SCCR information Termination and mounting specifications Ordering Code: 1413400 1333587CH (shown with cover) 1433124 (shown with marking strip) SERIES POLES IDENTIFIER COVER OPTION XXX X XXX XX Random 3-digit Blank = No Cover CH = Hinge Cover Attached Identifier Series s Available Dimensions Cover Type Available 141 1/2/3/4 Pg 21 Flat 140 2/3 Pg 22 Flat 132 0/1/2/3 Pg 21 Hinge 142 Pg 21 Flat 143 Pg 22 Flat 133 Pg 22 Hinge 1/2/3 144 Pg 23 Flat 145 Pg 23 Flat 135 Pg 23 Hinge

Power Blocks - Splicer/Distribution Amps Catalog # s il 60 141x403 1/2/3/4 Plastic AL 1 #10 - #18 2 115 141x300 1/2/3/4 Plastic AL 1 1 115 142x552 1/2/3 Phenolic AL 1 1 115 141x400 1/2/3/4 Plastic AL 1 #10 - #18 4 150 142x121 1/2/3 Phenolic CU 1/0-#14 1/0-#14 175 132x572 0/1/2/3 Plastic AL 2/0 - #14 1 2/0 - #14 1 175 142x572 1/2/3 Phenolic AL 2/0 - #14 1 2/0 - #14 1 175 132x972 1/2/3 Plastic CU 2/0 - #14 1 2/0 - #14 1 175 132x570 0/1/2/3 Plastic AL 2/0 - #14 1 #4 - #14 4 175 142x570 1/2/3 Phenolic AL 2/0 - #14 1 #4 - #14 4 175 132x580 0/1/2/3 Plastic AL 2/0 - #14 1 #4 - #14 6 175 140x402 2/3 Phenolic AL 2/0 - #14 1 #4 - #14 4 175 140x401 2/3 Phenolic AL 2/0 - #14 1 #4 - #14 6 175 132x970 0/1/2/3 Plastic CU 2/0 - #14 1 #4 - #14 4 175 142x970 1/2/3 Phenolic CU 2/0 - #14 1 #4 - #14 4 255 143x124 1/2/3 Phenolic CU 250 kcmil - #6 1 250 kcmil - #6 1 255 143x123 1/2/3 Phenolic AL 250 kcmil - #6 1 250 kcmil - #6 1 POWER BLOCKS

POWER BLOCKS Power Blocks - Splicer/Distribution Amps Catalog # s 255 140x801 2/3 Phenolic CU 250 - #6 1 250 - #6 1 310 140x303 2/3 Phenolic AL 350 - #6 1 350 - #6 1 310 143x126 1/2/3 Plastic AL 350 - #6 1 350 - #6 1 310 133x126 1/2/3 Plastic AL 350 - #6 1 350 - #6 1 310 140x404 2/3 Phenolic AL 350 - #6 1 #4 - #14 6 310 133x554 1/2/3 Plastic AL 350 - #6 1 2/0 - #14 2 310 140x410 2/3 Phenolic AL 350 - #6 1 2/0 - #14 2 310 143x554 1/2/3 Phenolic AL 350 - #6 1 2/0 - #14 2 310 133x324 1/2/3 Plastic AL 350 - #6 1 #8 - #14 24 335 144x401 1/2/3 Phenolic CU 400 - #6 1 6 335 143x552 1/2/3 Phenolic AL 400 - #6 1 4 335 143x553 1/2/3 Phenolic AL 400 - #6 1 6 335 144x560 1/2/3 Phenolic AL 400 - #6 1 8 335 133x552 1/2/3 Plastic AL 400 - #6 1 4 350 133x305 1/2/3 Plastic AL 2/0 - #14 2 2/0 - #14 2 350 143x306 1/2/3 Phenolic AL 2/0 - #14 2 2/0 - #14 2 350 143x555 1/2/3 Phenolic AL 2/0 - #14 2 #4 - #14 6 350 133x555 1/2/3 Plastic AL 2/0 - #14 2 #4 - #14 6 c

Power Blocks - Splicer/Distribution Amps Catalog # s 350 133x555 1/2/3 Plastic AL 2/0 - #14 2 #4 - #14 6 350 143x955 1/2/3 Phenolic CU 2/0 - #14 2 #4 - #14 6 350 133x955 1/2/3 Plastic CU 2/0 - #14 2 #4 - #14 6 380 143x953 1/2/3 Phenolic CU 500 - #4 1 6 380 133x953 1/2/3 Plastic CU 500 - #4 1 6 380 144x551 1/2/3 Phenolic AL 500 - #4 1 6 380 145x579 1/2/3 Phenolic AL 500 - #4 1 #2/0 - #14 4 380 133x587 1/2/3 Plastic AL 500 - #4 1 380 143x587 1/2/3 Phenolic AL 500 - #4 1 350 - #6 350 - #6 380 145x594 1/2/3 Phenolic AL 500 - #4 1 8 380 145x552 1/2/3 Phenolic AL 500 - #4 1 12 420 144x557 1/2/3 Phenolic AL 600 - #4 1 600 - #4 1 420 133x360 1/2/3 Phenolic AL 600 - #2 1 600 - #2 1 420 133x588 1/2/3 Plastic AL 600 - #2 1 1/0 - #14 420 133x595 1/2/3 Plastic AL 600 - #2 1 #4 - #14 12 420 133x585 1/2/3 Plastic AL 600 - #2 1 8 420 133x575 1/2/3 Plastic AL 600 - #2 1 2/0 - #14 4 3/1 3/1 6/3 POWER BLOCKS

POWER BLOCKS Power Blocks - Splicer/Distribution Amps Catalog # s 420 133x565 1/2/3 Plastic AL 600 - #2 1 250 - #6 2 420 135x601 1/2/3 Plastic AL 600 - #2 1 #6 - #14 24 c 475 135x701 1/2/3 Plastic AL 750-1/0 1 750-1/0 1 510 133x320 1/2/3 Plastic AL 250-1/0 2 250-1/0 2 510 133x596 1/2/3 Plastic AL 250-1/0 2 #4 - #14 12 510 133x597 1/2/3 Plastic AL 250-1/0 2 8 510 133x598 1/2/3 Plastic AL 250-1/0 2 2/0 - #14 4 620 145x129 1/2/3 Phenolic AL 350 - #4 2 350 - #4 2 620 1331348 1 Plastic AL 350 - #4 2 #8 - #14 48 690 145x587 1/2/3 Phenolic AL 500 - #4 350 - #4 1/1 2/0 - #14 4 760 145x301 1/2/3 Phenolic AL 500 - #4 2 500 - #4 2 760 145x592 1/2/3 Phenolic AL 500 - #4 2 #4 - #14 12 760 145x586 1/2/3 Phenolic AL 500 - #6 2 2/0 - #14 8 760 145x992 1/2/3 Phenolic CU 500 - #4 2 12 760 145x986 1/2/3 Phenolic CU 500 - #4 2 2/0 - #14 8 760 145x408 1/2/3 Phenolic AL 500 - #6 2 12 840 145x411 1/2/3 Phenolic AL 600 - #2 2 3/0 - #6 #4 - #14 4/4 1 UL Listed without a cover (CH). When covered, the product is to US and Canadian and standards (culus).

Power Blocks - Splicer/Distribution Amps Catalog # s 950 135x605 1/2/3 Plastic AL 600 - #2 2 350-4 4 950 135x702 1/2/3 Plastic AL 750-1/0 2 750-1/0 2 c POWER BLOCKS 950 135x703 1/2/3 Plastic AL 750-1/0 2 250 - #6 6 950 135x704 1/2/3 Plastic AL 750-1/0 2 2/0 - #14 10 950 135x705 1/2/3 Plastic AL 750-1/0 2 250 - #6 12/3 950 135x706 1/2/3 Plastic AL 750-1/0 2 250 - #6 4/5 950 135x707 1/2/3 Plastic AL 750-1/0 2 3/0 - #6 12/4 950 135x708 1/2/3 Plastic AL 750-1/0 2 3/0 - #6 8 2280 1453401 2 1 Phenolic AL 500 - #4 6 2/0 - #14 18 c 1 UL Listed when purchased without a cover (CH). When purchased with a cover, the product is to US and Canadian and standards (curus). 2 Special 1-pole power block with the dimensions of a 3-pole 145 series power block. Product specific data sheets (includes detailed drawings & SCCR Ratings) Request 2D/3D CAD files Check distributor stock Request samples