HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

Similar documents
HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

A. This Section includes the following domestic water piping specialties:

TECHNICAL. Series 18. Pump Packages

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Peerless Pump Company

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION HEATING BOILER FEEDWATER EQUIPMENT

University of Delaware

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

SECTION PLUMBING EQUIPMENT

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION HYDRONIC PIPING AND SPECIALTIES

In-Line Air Separators

B. Shop Drawings: Detail fabrication of pipe anchors, hangers, special pipe support assemblies, alignment guides, expansion joints and loops,

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION HYDRONIC PIPING

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Division 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL

Design and Construction Standards SECTION PLUMBING EQUIPMENT

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

PROJECT NAME: DPW Idaho State University Liberal Arts Building Chiller Replacement

PROJ. NO SECTION REFRIGERANT PIPING

SECTION PLUMBING EQUIPMENT

SECTION DOMESTIC WATER PUMPS

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

DIVISION 23 HVAC Hydronic Piping Systems

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

SECTION SPRINKLER SYSTEMS

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

FIRE SUPPRESSION SPRINKLER SYSTEM

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

SECTION ELECTRIC WATER HEATERS

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

SECTION METERS AND GAGES FOR HVAC PIPING

Packaged Semi-Instantaneous Steam Fired Water Heater

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

B. Related Sections: The following Sections contain requirements that relate to this Section.

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

BuildingName The Description of the Project P DOCUMENTS

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

B. Section Identification for Fire Suppression Piping and Equipment.

REFRIGERANT PIPING SYSTEM

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology

SPRINKLERS TABLE OF CONTENTS

UNIVERSITY OF MISSOURI Building Hydronic Piping and Pump Systems 2017 Q3

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

4. Provide brass valve tags marked for the service. See pertinent service specification for valve type.

Packaged Steam Fired Water Heater

SECTION ROTARY-SCREW WATER CHILLERS

Pipe: ASTM B88, hard drawn copper, Type K. Fittings: ASTM B16.22 Wrought copper and copper alloy.

Refrigerant Valves/Accessories

YALE Site Specifications AIR VENT SCHEDULE

PROJ. NO SECTION HYDRONIC PIPING

SECTION METERS AND GAGES FOR PLUMBING PIPING

High Capacity Instantaneous Steam Fired Water Heater

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

SECTION FUEL-FIRED DOMESTIC WATER HEATERS

A. ASHRAE Handbook HVAC Applications, Snow Melting and Freeze Protection

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

REFRIGERANT PIPING

GLOBAL FLOW PRODUCTS

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

Water Piping and Pumps

SECTION DRY-PIPE SPRINKLER SYSTEMS

Ratio Architects, Inc. Section Refrigerant Piping

DOCUMENT TABLE OF CONTENTS

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

SECTION ELECTRIC WATER HEATERS

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

WET-PIPE SPRINKLER SYSTEMS

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

Series 1156F, 1450F ( 1 2") Feed Water Pressure Regulators and Dual Controls for Hot Water Boilers

EXTROL EXPANSION TANKS

Transcription:

SECTION 15181 - HYDRONIC SPECIALTIES PART 1 - GENERAL 1.1 SECTION INCLUDES A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler B. Expansion tanks C. Pump accessories 1.2 RELATED SECTIONS A. Section - Plumbing Piping Specialties: B. Section - Hydronic Piping. 1.3 REFERENCES A. ASME (BPV VIII, 1) - Boiler and Pressure Vessel Code, Section VIII, Division 1 - Rules for Construction of Pressure Vessels; The American Society of Mechanical Engineers; 2010 Edition, 2011 Addenda. 1.4 SUBMITTALS A. See Section 01300 - Administrative Requirements, for submittal procedures. B. Product Data: Provide product data for manufactured products and assemblies required for this project. Include component sizes, rough-in requirements, service sizes, and finishes. Include product description, model and dimensions. C. All pressure vessels shall have U1 data reports signed by an inspector commissioned by the National Board of Boiler Inspectors. All pressure vessels shall be registered with the National Board. Certificates: Inspection certificates for pressure vessels from authority having jurisdiction. D. Manufacturer's Installation Instructions: Indicate hanging and support methods, joining procedures. E. Project Record Documents: Record actual locations of flow controls. F. Maintenance Data: Include installation instructions, assembly views, lubrication instructions, and replacement parts list. HYDRONIC SPECIALTIES TACO MPT Tank(s) 15181-1

1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: Company specializing in manufacturing the type of products specified in this section, with minimum five years of documented experience. 1.6 DELIVERY, STORAGE, AND HANDLING A. Accept valves on site in shipping containers with labeling in place. Inspect for damage. B. Provide temporary end caps and closures on piping and fittings. Maintain in place until installation. C. Protect piping components from entry of foreign materials by temporary covers, completing sections of the work, and isolating parts of completed system. 1.7 MAINTENANCE SERVICE A. Contractor to furnish service and maintenance for one year from date of substantial completion. 1.8 EXTRA MATERIALS A. See Section 01400 - Quality Requirements, for additional provisions. PART 2 - PRODUCTS 2.1 ASME Full Bladder Type EXPANSION TANKS A. Manufacturers: 1. Taco, Inc; Model CA : www.taco-hvac.com 2. ITT Bell & Gossett 3. Amtrol Inc 4. Substitutions: See Section 01600 - Product Requirements. B. Construction: Welded steel, designed, tested and stamped in accordance with ASME (BPV code sec VIII, div 1); supplied with National Board Form U-1, rated for working pressure of 150 psi, with flexible heavy duty butyl rubber bladder. Bladder shall be able to accept the full volume of the expansion tank and shall be removable and replaceable. Bladder shall be NSF 61 rated for potable water service and shall be manufactured with FDA approved materials. C. Accessories: Pressure gage (field installed by others) and air-charging fitting ; precharge to psi. D. Automatic Cold Water Fill Assembly (field installed by others): Pressure reducing valve, reduced pressure double check back flow preventer, test cocks, strainer, vacuum breaker, and valved by-pass. HYDRONIC SPECIALTIES TACO MPT Tank(s) 15181-2

E. Size: 1. Capacity: HW. CHW (acceptance volume to equal tank capacity) 2. Capacity of submitted tanks must be equal to or greater than specified units. No exceptions unless stated in an addendum. F. Hot Water Heating System: 1. Select expansion tank pressure relief valve at psi maximum. 2. Set pressure reducing valve at psi. G. Chilled Water System: 1. Select expansion tank pressure relief valve at psi maximum. 2. Set pressure reducing valve at psi 2.2 Multi-Purpose Tank - Air Separator, Buffer Tank, Hydraulic Decoupler A. Manufacturers: 1. Taco, Inc; MPT Series (size and capacity as called for on plans) 2. Spirotherm. 3. Flamco 4. Substitutions: See Section 01600 - Product Requirements. B. The Multi-Purpose Tank shall be constructed of steel. It shall be designed, fabricated and stamped per ASME Section VIII Division 1 with a maximum working pressure of 125 psi at 270 F. Manufacturer shall be holder of ASME U stamp. Manufacturer to have optional 250 psi and 150 psi ASME units available. The volume of the vessel and the system connections sizes shall be as called out on the schedule. C. The pressure vessel shall consist of four system connections that are arranged on the tank in a manner that hydraulically decouples the central plant from the secondary distribution system. D. All units with 2 and larger connections sizes shall be provided with flanged connections as standard. Both inlet and outlet to be in the same horizontal and vertical planes. With the four 3/4 system connections sensing ports installed to allow for pressure and temperature monitoring of the central chilled/hot water plant. [option] E. The air removal device shall be equipped with a brass conical shaped air venting chamber designed to minimize system fluid from fouling the venting assembly. The air vent shall be able to be closed to allow flushing and purging of dirt via side port without dirt passing through vent on initial system fill. F. A brass flushing cock shall be located on the side of each separator to facilitate system fast-fill and removal of the floating impurities from the air system interface within the separator. HYDRONIC SPECIALTIES TACO MPT Tank(s) 15181-3

G. A full port blow down valve shall be provided by the unit manufacturer on the bottom of each unit to allow blow down and cleaning. On all units the blow down valve shall be 2. 2.3 PUMP ACCESSORIES A. Pump discharge multi-purpose valves: All pumps shall be fitted with a discharge multipurpose balancing valve or other means of providing system balance, isolation, and check feature for reverse flow. The valve shall be straight or angle pattern and shall be field convertible between the two. The valve shall be ductile iron and rated for 250 psi working pressure for all jobs. The valve flanges shall be matched to suit the working pressure of the piping components on the job; either 125 psi or 250 psi. The valve shall include the following components; non-slam check valve with spring-loaded bronze disc and seat, stainless steel stem, and calibrated adjustment permitting flow regulation. Valve shall be serviceable under full system pressure. The valve shall be a Taco model MPV Plus Two multi-purpose valve or equivalent. B. Pump inlet guide fitting: All pump suctions to be fitted with a multifunction inlet guide fitting equal to that as manufactured by Taco, Inc. The suction guide body and cover plate shall be ductile iron and be rated for 250 psi for all jobs. The guide flanges shall be matched to suit the working pressure of the piping components on the job; either 125 psi or 250 psi. The suction guide shall include the following components; full length S.S. straightening vanes, permanent S.S. strainer, disposable 16 mesh bronze start up strainer, blow down ports, and metering ports. For those pumps where an inlet guide fitting is not installed, there should be five pipe diameters of straight undisturbed flow going into the pump suction. The fitting shall be a Taco model SD inlet suction elbow or equivalent. PART 3 - EXECUTION 3.1 INSTALLATION A. Install specialties in accordance with manufacturer's instructions. B. Where large air quantities can accumulate, provide enlarged air collection standpipes. C. Provide manual air vents at system high points and as indicated. D. For automatic air vents in ceiling spaces or other concealed locations, provide vent tubing to nearest drain. E. Air separator and expansion tank to be installed on the suction side of the system pumps. Expansion tank to be tied into system piping in close proximity to air separator and system fill line. F. Provide valved drain and hose connection on strainer blow down connection. G. Provide pump suction fitting on suction side of base mounted centrifugal pumps where indicated. Remove temporary strainers after cleaning systems. HYDRONIC SPECIALTIES TACO MPT Tank(s) 15181-4

H. Provide combination pump discharge valve on discharge side of base mounted centrifugal pumps where indicated. I. Support pump fittings with floor mounted pipe and flange supports. J. Provide radiator valves on water inlet to terminal heating units such as radiation, unit heaters, and fan coil units. K. Provide radiator balancing valves on water outlet from terminal heating units such as radiation, unit heaters, and fan coil units. L. Provide relief valves on pressure tanks, low pressure side of reducing valves, heat exchangers, and expansion tanks. M. Select system relief valve capacity so that it is greater than make-up pressure reducing valve capacity. Select equipment relief valve capacity to exceed rating of connected equipment. N. Pipe relief valve outlet to nearest floor drain. O. Where one line vents several relief valves, make cross sectional area equal to sum of individual vent areas. P. Clean and flush glycol system before adding glycol solution. Refer to Section 15185. Q. Feed glycol solution to system through make-up line with pressure regulator, venting system high points. Set to fill at psi. R. Perform tests determining strength of glycol and water solution and submit written test results. END OF SECTION 15181 HYDRONIC SPECIALTIES TACO MPT Tank(s) 15181-5