Metropolitan high output natural and powered trench heaters

Similar documents
H Y D R O C O U R S E T R E N C H H E A T I N G

Enriching Environments

CASSETTE UNIT. Comfort Circle

Trench Heating. Katherm NK

Trench Heating. Katherm QK with EC Technology

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet

Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium

TRENCH HEATERS COMMERCIAL/DOMESTIC INNOVATIVE VENTILATION & HEATING

Providing Natural Solutions to Heating

Sill Line Perimeter Casing. Warmline Trench Heating. Vectair Natural Convectors. Spirally Wound Gilled Tube

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Halton CHB Active chilled beam with boost function for bulkhead installation

Units for suspended ceilings

INSTALLATION INSTRUCTIONS

Energy-efficient heat source provides comfort in large rooms

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Trench Heating Katherm QK

Fan heater SWT Ceiling mounted fan heater with water heat

Technical documentation Fan coil unit

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

Fan coil unit KL. Wall unit Ceiling unit

INDUSTRIAL AIR CURTAIN. IndAC 2

Units for suspended cei lings

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Panther Fan Coil Units

spc-hvac.co.uk BELGRAVIA eco FAN CONVECTORS WITH EC MOTORS

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

Katherm QK nano. trench heating. Katherm QK nano. Ultra-small trench heaters with EC tangential fan Technical catalogue

Panther Fan Coil Unit

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Cooling Strip Model SPB

Katherm HK with EC Technology

BELGRAVIA eco FAN CONVECTORS WITH EC MOTORS

Aegean Range. A new range of fan coils for heating and cooling commercial applications

Cassette units Model Comfort Circle. - heating - cooling - ventilation

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

Halton Rex 600 Basic R6B - Active chilled beam

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

SERIES BM. Concealed Fan Convector

Ocelot Fan Coil Units

Aluminium Curtain Tracks

S E R I E S B M C O M F O R T, A V A N T - G A R D E & L S T F A N C O N V E C T O R S

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

Condensing Units CUS 15-60

Hudevad Plan. Technical datasheet

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Polaris-I-60. active chilled beam. the future of space conditioning

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Optimal work climate with open doors. Industrial air curtains Model IndAC

TOSHIBA AIR CONDITIONING

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

VERTICAL FAN COIL UNITS

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

LindabCapella. Supply air beam

Specialists in Bespoke Trench Heating Tel:

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

Specification Data. General:

WOLF VENTILATION SYSTEM PRICE LIST

WIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. access panel Fan speed and on/off switches. Discharge spigot. Fan/motor.

External venetian blinds

DENON HEOS. Accessories for

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

TOSHIBA AIR CONDITIONING

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

Primo Hotel. General. Indoor climate units for hotel rooms

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

Commercial Heating Domestic Heating

enviroblinds external blinds & shutters the secret to low carbon comfort

CAW Ceiling-mounted fan heaters for hot water

Technology for life. Unit heater LH

Hudevad P5. Technical datasheet

RAYPAK HOT WATER & HEATING

MINI CANAL DBE 2015.UK

AIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Installation, Operation and Maintenance Instructions Document Ref:

HOTEL CHILLED BEAM IQ STAR SILENCIA

QTS SELECTION TECHNICAL BOOKLET

Thermozone AC 300/WAC 300

Series VENTS VUT R WH ЕС

Installation, Operation & Maintenance Instructions Document Ref:

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

Wall Mounted Split Systems

42AM. Air heaters PRODUCT SELECTION DATA

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

CLIMA CANAL HYBRID CLIMA CANAL. Low Water Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING LOW TEMPERATURE SYSTEM / HEATING

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

OPTIMIZED CONVECTION. unique heating technology. Catalogue

& M A I N T E N A N C E

AIR CURTAIN T SURFACE MOUNTED RANGE

Fan coil units with centrifugal fan

Transcription:

Metropolitan high output natural and powered trench heaters

High output trench heaters Typically used in large glazed areas to reduce glazing losses, these units are the perfect way to enhance comfort. Features and benefits Made in Leicester, UK Independently tested to BS EN 16430 Installed beneath floor-to-ceiling windows to unobtrusively eliminate draughts and enhance comfort Cool air drops into the trench and passes through the coil/heat exchanger, picking up heat and rising over the window. This warmed air helps eliminate draughts, circulating around the room before it cools and falls to the floor Suitable for installation in screeded or suspended floors Trench heating is used in offices, reception areas, hotels, restaurants and residential properties Powered units can be specified when enhanced heat outputs are required. Low power fans are whisper quiet in operation and use EC/DC technology for enhanced controllability and energy efficiency. Designs to suit all applications We listen to our customers and offer flexible solutions wherever possible. Natural unit dimensions 3x widths 150mm, 225mm and 300mm 3x heights 90mm, 145mm and 200mm 24x lengths 800mm to 3100mm in 100mm increments Powered unit dimensions 4x widths 180mm, 225mm, 260mm and 300mm Single 110mm height 22x lengths 1100mm to 3200mm in 100mm increments Do you require a bespoke fit? Bespoke widths, heights and lengths are available on request Also available on request are bespoke curved sections and grilles Corner kits with angled sections and mitred corner grilles are available as required. Please don t hesitate to contact a member of the SPC sales team who will be more than happy to help you find the components you need to make your trench heating system perfect for its environment. Easily create longer runs by connecting together using flangeless end plates. 2

Thoughtful construction 1.2mm thick mild steel construction painted black (inside and out), with reinforcing cross braces and knock outs for site pipework A cover plate is included to not only hide connections but protect against dirt 5mm edging trim matches or complements the finish and colour of the grille Height adjustable feet (adjustable by up to 30mm) are coupled with load bearing supports Telescopic supports are available for suspended floor applications Left handed coil (looking inside to out) compromising 1, 2 or 3 rows made from 12mm o/d copper tube mechanically expanded into continuous aluminium fins Made with 15mm same end, flow and return connections. The water flow pipework is closest to the window and the water return pipework is furthest from the window Powered units incorporate EC/DC fan motor technology to enhance energy efficiency and provide simple controllability. Units require only a standard mains supply for operation. Metropolitan high output natural and powered trench heating 3

Architectural grilles We consider every aspect of the trench heater, including the grilles. As standard, our roll-up anodised aluminium grilles use corrosion-proof steel springs and black spacers. The double-t profile grille blades are 5mm wide and 19.5mm high with a spacing of 12.5mm. This gives a free area of 60%. Grilles and trim are available in a variety of colours. Pale Umber Anolok 541 Umber Anolok 543 Dark Umber Anolok 545 Bronze Anolok 547 Dark Bronze 549 Black Anolok 54B Regency Gold 1 Regency Gold 2 Regency Gold 3 Satin Silver Pale Blue / Grey Anolok 711 Light Blue / Grey 713 Med Blue / Grey Anolok 715 Dark Blue / Grey Anolok 717 Stainless Steel * Stainless steel grilles are available on request. Grille trim is not available in stainless steel. 4

Complement your design We know how important it is for the trench grilles to fit in with your design criteria, which is why we offer an extensive range of grille and trim colours. Quite simply we don t want to hold back your imagination Metropolitan high output natural and powered trench heating 5

Connections - natural units Connections can be front or side entry Water Flow 15 x 50 Straight Copper Water Flow Water Return Water Return Two Port Valve & Actuator 15 Compression Fitting 400 long hoses with integral quarter turn isolation valves Two Port Valve & Actuator 15 x 150 x 90 Copper 400 long hoses with integral quarter turn isolation valves 15 Compression Fitting The 2-port valve and actuator will not fit inside the two smallest sizes, and must be fitted externally to the trench unit. *Hose lengths are approximate. Two Port Valve & Actuator Fitting Height Width 90 145 200 150 External Only External Only External or as Shown 225 External or as Shown External or as Shown External or as Shown 300 External or as Shown External or as Shown External or as Shown 6

Connections - powered units Connections can be front or side entry Water Return Water Flow 600 long hoses with integral quarter turn isolation valves Water Flow Water Return 230VAC Connections Below Bracket 15 Compression Fitting BMS Connection Point 230VAC Connections Below Bracket 15 Compression Fitting 400 long hoses with integral quarter turn isolation valves BMS Connection Point *Hose lengths are approximate. Metropolitan high output natural and powered trench heating 7

Controls for comfort We ve thought of everything you might need to enrich your environment All units can be supplied with flexible hoses for connecting to the flow / return pipework. These hoses can be fitted with isolating valves for added convenience. Natural units are controlled on the water side and we offer a range of 2 port control valves and actuators along with a range of attractive wall mounted thermostats. While powered units can be controlled on the water side and supplied with valves the inclusion of EC/DC fan motor technology makes air side control simple and accurate. Fan speed is set via a 0-10V control signal which can be supplied via a BMS or room mounted controller. Alternatively, the fan speed can be set manually using the on-board rotary potentiometers. 2 port Valve Actuator Room Thermostat Flexible Hose with Integral Isolating Valve 8

Heat outputs - natural units For information on outputs for other conditions contact SPC s sales team. LPHW = 80/60 C & Room Air Temperature = 20 C (ΔT = 50 C), Medium Speed Width 150mm 225mm 300mm Height 90mm 145mm 200mm 90mm 145mm 200mm 90mm 145mm 200mm Trench Length (mm) 900 120 197 278 180 337 368 239 430 491 1000 141 232 327 211 397 433 281 506 578 1100 162 266 376 243 456 497 323 581 664 1200 183 301 425 274 515 562 365 657 750 1300 204 336 473 306 574 627 407 732 836 1400 225 370 522 337 633 691 449 808 922 1500 246 405 571 369 693 756 491 883 1009 1600 267 439 620 400 752 820 533 959 1095 1700 288 474 669 432 811 885 575 1034 1181 1800 309 509 717 463 870 950 617 1110 1267 1900 330 543 766 495 929 1014 659 1185 1353 2000 351 578 815 526 989 1079 701 1261 1440 2100 372 612 864 558 1048 1143 743 1336 1526 2200 393 647 913 589 1107 1208 785 1412 1612 2300 414 682 961 621 1166 1273 827 1487 1698 2400 435 716 1010 652 1225 1337 869 1563 1784 2500 456 751 1059 684 1285 1402 911 1638 1871 2600 477 785 1108 715 1344 1466 953 1714 1957 2700 498 820 1157 747 1403 1531 995 1789 2043 2800 519 855 1205 778 1462 1596 1037 1865 2129 2900 540 889 1254 810 1521 1660 1079 1940 2215 3000 561 924 1303 841 1581 1725 1121 2016 2302 3100 582 958 1352 873 1640 1789 1163 2091 2388 Heat output in W. Water flow rate calculated as follows: Water flow rate (l/s) = Heat output (W)/4190/Water temperature drop ( C) Metropolitan high output natural and powered trench heating 9

Heat outputs - powered units For information on outputs for other conditions contact SPC s sales team. LPHW = 80/60 C & Room Air Temperature = 20 C (ΔT = 50 C), Medium Speed Trench Width (mm) Trench Length (mm) 180mm 225mm 260mm 300mm 1100 470 782 971 1091 1200 494 813 1003 1129 1300 518 844 1036 1167 1400 542 875 1068 1205 1500 566 906 1100 1243 1600 590 937 1132 1281 1700 932 1553 1931 2169 1800 956 1584 1963 2207 1900 980 1615 1996 2245 2000 1004 1646 2028 2283 2100 1028 1677 2060 2321 2200 1052 1708 2092 2359 2300 1394 2324 2891 3247 2400 1418 2355 2923 3285 2500 1442 2386 2956 3323 2600 1466 2417 2988 3361 2700 1490 2448 3020 3399 2800 1514 2479 3052 3437 2900 1538 2510 3084 3475 3000 1562 2541 3117 3513 3100 1586 2572 3149 3551 Heat output in W. Sound pressure level Medium speed < 30dba @ 2m Water flow rate calculated as follows: Water flow rate (l/s) = Heat output (W)/4190/Water temperature drop ( C) 10

Water pressure drop - natural units 3.5 3 Pressure drop (kpa/m) 2.5 2 1.5 1 0.5 0 0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045 Water flow rate (l/s) Key 150/90 150/145 & 300/90 150/200 & 225/145 225/90 300/145 225/200 300/200 Water pressure drop in kpa per metre run of trench. Metropolitan high output natural and powered trench heating 11

Water pressure drop - powered units 10 9 8 Pressure Drop (kpa/m) 7 6 5 4 3 2 1 0 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 Water Flow Rate (l/s) Key 180 Wide 225 Wide 260 Wide 300 Wide Water pressure drop in kpa per metre run of trench. 12

Dimensional drawings - natural units Connections Copper 15 Plain Cross Brace 256 70 Air Vent Connection Cover 5 12 Pipe Knock-Outs Ø30 Height Adjustment Screws 0-30 17 Cable Knock-Out Ø16 300 (from each end) V W 35 60 40 Unit Width 150 / 225 / 300 R T Unit Height 90 / 145 / 200 Coil W V Width at Feet 200 / 275 / 350 Width (mm) Height (mm) Vertical distance between water flow knock-out & bottom (mm) Vertical distance between water return knock-out & bottom (mm) Horizontal distance between water flow knock-out & side (mm) Horizontal distance between water return knock-out & side (mm) V W R T 150 90 43 24 39 69 225 90 43 24 39 69 300 90 43 24 39 135 150 145 98 41 39 69 225 145 98 41 69 102 300 145 98 41 102 135 150 200 153 58 39 69 225 200 153 58 69 102 300 200 153 58 102 135 Metropolitan high output natural and powered trench heating 13

Dimensional drawings - powered units Connections Copper 15 Plain Cross Brace 390 70 Air Vent Electrical Connections 12 Connection Cover 5 Pipe Knock-Outs Ø30 Height Adjustment Screws 0-30 17 Cable Knock-Outs Ø16 300 (from each end) W V 60 90 195 40 Unit Width 180 / 225 / 260 / 300 T R Coil Unit Height 110 V W Width at Feet 230 / 275 / 310 / 350 Width (mm) Height (mm) Vertical distance between water flow knock-out & bottom (mm) Vertical distance between water return knock-out & bottom (mm) Horizontal distance between water flow knock-out & side (mm) Horizontal distance between water return knock-out & side (mm) V W R T 180 110 67 34 39 53 225 110 67 34 53 71 260 110 67 34 53 110 300 110 67 34 53 148 14

Specification Trench casings shall be from a minimum 1.2mm thick mild steel finish in black powder coat. The trench shall be c/w knock-outs for pipework and cables where required. Fine adjustment levelling screws shall be provided at all four corners and adjustable support feet along the length of the casing. The casing shall be supplied with transverse bracing pieces and a protective cover. The heat exchanger shall be manufactured from an array of copper tubes expanded into aluminium fins supported in galvanised sheet steel tubeplates. Flow and return connections shall be 15mm plain copper and the heat exchanger shall be fitted with a vent plug to purge air. Prior to fitting, the heat exchanger shall be pressure tested to 22 barg, air under water. Trench units shall be supplied, as standard, with anodised aluminium roll-up type grilles. The grilles shall consist of the aluminium blades, stainless steel springs and plastic spacers coloured to match the blades. Blades are optionally available in a range of anodised colours and can be provided in stainless steel. Trim pieces shall be supplied for fitting around the edge of the trench casing to match the grille. The units shall be performance tested in line with the requirements of EN 16430 and shall comply with all relevant European safety directives and harmonised standards. Powered trench units shall include one or more EC/DC crossflow fan assemblies. The fan speeds shall be capable of continuous modulation from a 0 to 10V control signal or on/off control. The fan assemblies shall be c/w with finger guards on the inlet side. Trench units can optionally be supplied with a range of flexible hose fittings, control valves and thermostats to suit the application. Metropolitan high output natural and powered trench heating 15

SPC House Evington Valley Road Leicester LE5 5LU T: 0116 249 0044 E: spc@spc-hvac.co.uk spc-hvac.co.uk Mettrench iss5