Akiki Engineering Est.

Similar documents
Akiki Engineering Est.

Pipe: ASTM B88, hard drawn copper, Type K. Fittings: ASTM B16.22 Wrought copper and copper alloy.

BOILER HOUSE PRODUCTS GMS

PIPING APPLICATION GUIDE

Installation, Operation, and Maintenance Manual

Descaler & Prevention

Protective Chemistry for Steam Boiler Wet Layup posted to DPS client area on:

DISPENSING TROUBLESHOOTING INDEX

Installation & Operation Manual Models:

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT

BOILER SYSTEM CHEMICAL TREATMENT 101

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Scale Stopper Plus Installation & Start-Up Guide

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Membrane cleaning of RO-system with the isave unit

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Brazed Plate Heat Exchanger Instruction Manual for BX Series

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

ACC is suitable for all types of diesel engines. The ACC / fresh water mixture has no flash point and cylinder lubrication is not impaired.

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

HG-1500 Ozone Generator

Daikin Water Cooling, Heating, and High Capacity Booster Coils

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS

9.0 Systems For Domestic Water Installations

SEALED THERMAL STORE

Tier1 Water Home Filtration System

Humidifier De-scaling Solution. and Neutralizer. Usage Instructions. IMPORTANT: Read and save these instructions. Before

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

Industrial Descale Solutions & Descale Services

Installation, Operation and Maintenance Manual

READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions

ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

Survivor 35 (Model # ) GB DE FRA NL DK SWE NOR FIN IT ESP POR

Other Things I Should Know?

INSTALLATION & MAINTENANCE MANUAL CSXT INSTANTANEOUS STEAM WATER HEATER Copyright 2006 PVI Industries, LLC

PIPING GUIDE TECHNICAL APPLICATION GUIDE GF-136-P. Modulating and Condensing Boilers

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

Pesticide Applicator Equipment Cleaning to Prevent Carryover. Chuck Schuster University of Maryland Extension

.2 Section Waste Management and Disposal..5 Section Cleaning and Startup of Mechanical Piping Systems.

ADVANCE ECB ELECTRIC COMBINATION BOILER

Balba. Technologies Limited. An Introduction to Side Stream Filtration And the Balba Viking Product Range

Infra Red Basin Tap IR120CP.1 & IR121CP.1

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

AQUA ONE. Reverse Osmosis System Model ARO5000. Installation and Service Guide PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

A FREAK INCIDENT OF A BED SUPERHEATER FAILURE

02 COOLING SYSTEM 02 COOLING SYSTEM COOLING SYSTEM INDEX. 1. General Specifications... 65

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

Heat Exchanger Piping Hook-up

Genesis Whole House Chlorination System Page 2

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE INSTALLATION - OPERATION - MAINTENANCE

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

Installation Instructions PP-AS20 Anti-Scale System

NOBURST. NOBURST Antifreeze & Heat Transfer Fluid Factory Pre-mixed Freeze Protection for Water-based Heating and Cooling Systems

Gulf Perlite L.L.C: Perlite Filter Aid Technical Brochure

Case Study and 700 HP Steam Boilers - Scale

Series 300 VTB. Installation Instructions

WL380 QUICK START GUIDE

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL

S. P. THERMAL SYSTEMS INC.

Installation, Operation and Maintenance Manual

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

New Product Introductions 2011

HAVABLACK S2G BLACK OXIDE SALTS FOR IRON & STEEL

Carry Out Maintenance Procedures

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

Cleaning and Sanitation Procedures Module Deli

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

CENTRA-COIL QUALITY HOT WATER SERVICE

WARRANTY POLICY & RECOMMENDED MAINTENANCE

INFINITY FLUIDS CORPORATION

OHM N PREPARATIONS & SUPPORT FOR A WATERTUBE BOILER Fax: P.O. Box 96. Russell, IL

PASSIVE HEAT EXCHANGER ANTI-FOULING FOR SOLAR DHW SYSTEMS

GROWMAX WATER Perfect Water for Plants and Gardens

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Z86 Safety-Plus Industrial Cleaner Concentrate

Caractéristiques Unités Valeurs Méthodes. Appearance - Colourless Visual. Density (at 20 C) kg/cm³ 1,52 - Purity % 99,8 -

J-PRO-24 Soda Ash Injection Installation & Start-Up Guide

Owner Manual Pre-Heat Appliances Single Wall Heat Exchanger

10 Quickbreak. Cleaning & Maintenance Products

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment

INSTALLATION INSTRUCTIONS WARRANTY

Residential Application

Eliminator TotalGuard Installation Manual

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

SuperStor Glass Lined Storage Tank

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

SPECIFICATION, INSTALLATION AND OPERATION MANUAL UNDER BENCH GLASS WASHER EVO40ST

Models: FM FM WARNING

Installation & Operating Instructions

SuperStor Ultra Stainless Steel Storage Tank

DISPENSE TROUBLESHOOTING INDEX. Hot Tank Descaling Instructions are included in this Troubleshooting section.

A PRACTICAL GUIDE TO KUUL VITALITY EVAPORATIVE MEDIA MAINTENANCE AND SERVICE

Closing procedures for in-ground pools

Operating instructions

Transcription:

Akiki Engineering Est. Water & Steam Experts 4.1. Closed System Catalogue October 7, 2010

Contents Chemical Products for Closed Systems......................... 3 Equipment For Closed Systems (1)........................... 4 Chemical Dosing Pots.................................. 5 Equipment For Closed Systems (2)........................... 7 2

4.1.3 Chemical Treatment / Closed System Chemical Products for Closed Systems Treatment Benefit Features: Eliminates leakage caused by corroded pipes, joints, etc. Prolong the life of your equipment. Reduce maintenance cost. Maintain cooling and heating efficiencies Pipe Cleaner: CCH 4200 Closed System Liquid used to clean and flush loop containing dirty water and large amounts of rust and scale Remakes soluble the mineral deposit and disperse the none soluble particles You don t have to stop the installation, and on metallic surfaces, it has a passive action After the curative treatment, it is necessary to make a preventive treatment by using CVA 4110 (soft water) and biocide for microbiological control CFR 2260 Dosage rate: 1 % to 5 % of system volume Package: can of 20kg Anticorrosion & Antiscale: CVA 4110 Liquid used for the control of corrosion in closed systems, chilled and hot water heating systems (soft water) Combination of corrosion inhibitors, scale inhibitors and a buffer (caustic soda) Dosage Rate: 118 g / m3 / 0TAC Storage: Keep away from freezing area Package: Can of 20 and 200 kg, container of 1000 kg Microbiological Control: CFR 2260 Used as preservative, bactericide, microbiocide, odour controller, and anti-fouling agent Used when there is a sterilisation Dosage is function of contamination state of the treated circuit, seasons, temperatures Sterilisation: 200 to 300 ppm, Maintenance: 100 to 150 ppm Storage: Keep away from freezing point Package: Can of 20, 25 and 230 kg AKIKI Engineering 3

4.1.4 Chemical Treatment / Closed System Equipment For Closed Systems (1) Controller Cold Water Meter Controller Digital readout display Control inhibitor feeding based on make-up volume Conductivity / ph function: Sensor, set point, high/low alarm Set points and alarms (Conductivity, ph) Control biocide-feeding program Furnish one microprocessor per independent closed system. Cold Water Meter Provide a make-up water meter sized the same as the make-up line A water meter is to be hard wired into the microprocessor controller, registering and accumulating total gallons of make-up water. Furnish a make-up water meter per each independent closed system La Madonna Bldg, Saide Str., Ashrafieh, Beirut, Lebanon POB: 16-6979 Beirut, Lebanon 4 Web: www.akikieng.com Tel +961 1 339 322 Fax +961 1 330 491

4.1.5 Chemical Treatment / Closed System Chemical Dosing Pots Correct water treatment is essential for the corrosion protection of heating system. Thermal products chemical dosing pots offer a safe and convenient way to introduce water treatment chemicals to the system. General Guidelines for installation and use are given below. However, the equipment and water treatment in use in any individual system may dilate variations so please consult your water treatment supplier to ensure best results. Closed System Installation Choose a location near a main pope run or system header. Fasten the chemical dosing pot securely in place using the brackets provided. Pipe the drain away to a safe disposal point. Connect the system connections to the pipe or system header. To ensure that there will be a flow through the chemical dosing pot leave sufficient gap between the connection points to give a difference in dynamic pressure between them ( 1 meter apart should be enough). This will admit the water treatment gradually to the system water. Alternatively, connect between flow and return headers, which will admit the water treatment more quickly. Each dosing pot is supplied as standard complete with the following Operating Specifications: System isolation valves Dosing valve Drain valve Air vent Funnel Blue gloss paint finish For full technical details see drawing No. AKIKI Engineering 5

4.1.6 Chemical Treatment / Closed System Features: Furnish a chemical dosing pot with suitable capacity (Liters) per each independent closed system. Other sizes are available Use Caution The dosing pot contents may be hot. Take care, avoid scalding. On higher temperature systems the contents may be above atmospheric boiling point. Opening valves may cause a release of flash steam. Isolate the chemical dosing pot from the system by closing the two system ball valves. Slowly open the drain valve- caution-some water and flash steam may be emitted to the disposal point. Open the dosing valve, and the vent screw. The contents will now drain out. Close the drain valve Fill the chemical dosing pot the vent with the required amount of chemicals, diluted as necessary. Close the dosing valve and the vent screw. Open the system valves to allow system water through the unit. La Madonna Bldg, Saide Str., Ashrafieh, Beirut, Lebanon POB: 16-6979 Beirut, Lebanon 6 Web: www.akikieng.com Tel +961 1 339 322 Fax +961 1 330 491

4.1.7 Chemical Treatment / Closed System Equipment For Closed Systems (2) Chemical Feeding Equipment Side Stream Filtration Unit Chemical Feeding Equipment We provide positive displacement diaphragm chemical metering pump with the following properties: Fully adjustable speed and stroke settings over the entire operating range Furnish two chemical metering pumps per independent closed system. One pump for inhibitor feed and one pump for biocide. Polyethylene chemical feed tank is provided. Each tank shall have a drum level switch agitator, incorporated in it. Also locally made chemical tanks can be provided Side Stream Filtration Unit Closed System Including sand filter, filter pump, strainer and controls, factory assembled, piped and wired mounted to steel skid. Complete with all accessories and electrical panel board. Other series are also available Disinfection A new main after installation should be pressure tested, flushed to remove dirt or foreign matter, and disinfected with a minimum chlorine concentration of 50 mg/l. The chlorinated water should remain in the pipe for a minimum of 24 h then 200 mg at least 3 h. The chlorinated water should be flushed to waste by using potable water. Microbiological tests should then be conducted before placing the main in service. Tanks and reservoirs should be disinfected before being placed into service or following inspection and cleaning. AKIKI Engineering 7