DIVISION 10 - SPECIALTIES SECTION 10671 METAL STORAGE SHELVING PART 1 GENERAL 1.1 SUMMARY A. Provisions of the General and Supplementary Conditions and Division 01 apply to this section. B. Section Includes 1. Steel Shelving, counters, and storage cabinets C. Related Sections: 1.2 SUBMITTALS 1. Section 05500: Metal Fabrications. 2. Section 06400: Architectural Woodwork A. Shop Drawings: Submit plans, elevations and details indicating details of assembly, shelving locations and methods of attachment. B. Product Data: Manufacturer's data for special construction and non-standard shelving required. C. Material Samples: Submit Samples of finished metal. 1.3 QUALITY ASSURANCE A. Qualifications of Installer: Shelving shall be installed by a firm having at least 5 years experience in installations of comparable scope and complexity. PART 2 PRODUCTS 2.1 SHELVING SYSTEMS 1. Provide Rivet (boltless) industrial shelving systems by Ciso-Eagle (or equal) 2120 Valley View Lane, Dallas TX 75234 Phone: (972) 406-9330, Fax: (972) 406-9577, Toll-Free: (800) 877-3861, Website: www.cisco-eagle.com 2. Series: RiveTier Boltless Rivet Shelving 3. Color: Grey a. Metal components, except aluminum and plated parts, shall be furnished with a phosphatized baked enamel factory finish installed in 2 coats with 0.001 inch METAL STORAGE SHELVING 010671 PG 1
minimum dry film thickness. Finish coat shall be smooth, free of streaks, drops, sags, pinholes, checks, cracks, peeling, blisters, and foreign material. b. Bolts, nuts and clips shall be zinc-plated. 4. Span: Long Span 5. Shelf Capacity: Heavy Duty 500 lb min weight capacity 6. Section Widths: 60 inches or 72 inches. Must work with wire shelving. 7. Depth: 36 8. Height: 84 PART 3 EXECUTION 3.1 ERECTION 9. Shelf Decking: Wire with min 500lb weight capacity 10. Number of Shelves per Section Width: Two 11. Exposed faces of shelves shall be furnished with continuous label holders, 7/8 inch minimum in height and fabricated from 24 gage steel. Fasten to shelf with 3 bolts. A. Steel shelving shall be installed plumb and level. Install over zinc-plated floor plate, 13 gage minimum, installed under upright posts. B. Anchoring: Steel shelving shall be fastened to walls. 1. Walls: Fasten shelving to walls through rear shelf flange at each end and alternate section, at top shelf and at second shelf from bottom. Omit floor anchoring. 2. Fasteners: 3.2 ADJUSTING a. Concrete: 5/16 inch diameter, 1-1/2 inches minimum penetration, and self-drilling concrete anchors. b. Wood: 1/4 inch minimum diameter plated lag screw with 1-1/2 inches minimum penetration into wood. A. Install and securely tighten fasteners. 3.3 CLEANUP A. Remove rubbish, debris and waste materials and legally dispose of off the Project site. METAL STORAGE SHELVING 010671 PG 2
3.4 PROTECTION A. Protect the Work of this section until Substantial Completion. END OF SECTION METAL STORAGE SHELVING 010671 PG 3
July 30, 2015 PROJECT MAHG101059-4908 REPAIR EDUCATIONAL LODGING 5022 Keesler Air Force Base Biloxi, Mississippi Ref: Electrical Addenda The following information shall be incorporated and installed per the original construction documents. Changes and Additions to the Drawings: 1. Sheet E0.0 ELECTRICAL LEGEND AND NOTES a. Add the following to the Fire Alarm System Notes: 26. Fire alarm systems shall be installed per the Unified Facilities Criteria (UFC) Fire Protection Engineering for Facilities Change 3, March 1, 2013. 27. Per UFC Section 5-6.7 Sleeping Rooms and Duty Rooms shall have 24 Vdc photoelectric analog/addressable smoke detectors installed in all barracks, dormitories, lodges, temporary or transient living facilities sleeping rooms and entry/common area to bedrooms, and duty rooms located in business or other occupancies. 28. Smoke detectors in sleeping rooms must cause the sounder base to activate for all smoke detectors in that suite and an alarm signal to activate at the FACP, but must not activate the building s evacuation alarm. 2. Sheet E2.7 - FIRST FLOOR FIRE ALARM & MECHANICAL PLAN a. Storage Room 141 Add a pull station at the inside of the exterior door exiting the room. b. Add (1) system smoke detector to the following rooms: 143, 144, 145, 147. c. Add (2) system smoke detectors to the following rooms: 141. d. In all typical dorm/sleeping rooms, the new 120 volt duct detector shall e. All fire alarm devices shown on this sheet shall be system devices. Wire 3. Sheet E2.8 - SECOND FLOOR FIRE ALARM & MECHANICAL PLAN a. Add (1) system smoke detector to the following rooms: 243, 252, 253, 255, 256. b. In Dorm Rooms 233 and 234 Add a system smoke detector and fire alarm system room speaker in each sleeping room.
July 30, 2015 Electrical Addenda PROJECT MAHG101059-4908 REPAIR EDUCATIONAL LODGING 5022 Page 2 of 2 WELCON Electrical Consultants, PLLC 14231 Seaway Road, Suite #3002 Gulfport, MS 39503 Phone: 228.822.8000 Fax: 228.206.3000 Web: welconconsultants.com c. In all typical dorm/sleeping rooms, the new 120 volt duct detector shall d. All fire alarm devices shown on this sheet shall be system devices. Wire 4. Sheet E2.9 - THIRD FLOOR FIRE ALARM & MECHANICAL PLAN a. Add (1) system smoke detector to the following rooms: 343, 352, 353, 355, 356. b. In Dorm Rooms 333 and 334 Add a system smoke detector and fire alarm system room speaker in each sleeping room. c. In all typical dorm/sleeping rooms, the new 120 volt duct detector shall d. All fire alarm devices shown on this sheet shall be system devices. Wire 5. Sheet E3.1 ELECTRICAL ENLARGED PLANS a. In typical dorm/sleeping rooms, the new 120 volt duct detector shall not be installed. In place of each 120 volt detector shown on plans, provide and install a system smoke detector per the UFC noted above. b. All fire alarm devices shall be system devices. Wire complete system components with new conduit and wiring as detailed. Route conductors back to main fire alarm panel or fire alarm terminal