Notes: Warrick Series 67 Intrinsically Safe Multi-Function Control Installation and Operation Bulletin

Similar documents
PumpSaver ISS-105 IS Super Cell Installation Guide

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

Fire Alarm System Accessories

Fire Alarm System Accessories

INSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SET-2000 Hi Level/Oil

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Tank Gauging System Special Safety Instruction

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

SET-2000 Oil/Sludge 12 VDC

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

SET Installation and Operating Instructions. Level switch for one sensor

OilSET-1000 (12 VDC)

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

Raychem Heating System

LC3000 Level Controller Installation and Maintenance Instructions

Z24 Wireless Zone Controller Professional Installation Guide

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

RA889A Switching Relay

LC1350 Level Controller

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

Pump-Down Controller MODEL 4052

Power Supply Display Module PSDM. Installation and Operation Manual

232xt Wiring Diagrams and Specifications SPECIFICATIONS: REV 1.01

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Scully ST-15 WX. Technical Manual. Multi-Point Liquid-Level Detection System

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Operating Manual MS220KA and MSR220KA

DIGITAL METERS Large Display Temperature Meters Instruction Manual

RA889A Switching Relay

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

General Routing Interface

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Declaration of conformity

Certificate of Compliance

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

PROTEUS Series OEL8000III-K. Tank Gauging System. Installation Manual

E340 BOILER CONTROL INSTALLATION MANUAL

ESSEX ENGINEERING CORPORATION

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

7800 SERIES RM7888A Relay Module

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

Pump-Up Controller MODEL 4062

ARM SERIES Switching Relays With Priority

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Two-Channel Gas Controller

4 & 8-POINT ANNUNCIATORS Instruction Manual

Certificate of Compliance

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

Conventional Fire Alarm Systems

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

Wiring Diagrams. 9AB4-12 Air-Cooled Remote Condenser INDEX OPERATING SEQUENCE ACCESSORIES LEGEND AND NOTES FOR FIG. 1-6

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

TECHNICAL DATA OBSOLETE

IECEx Certificate of Conformity

SAFETY INFORMATION AND WARNINGS

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

DB5 Intrinsically Safe Sounder Type DB-5

Today's world of increasing

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

Schneider Electric Erie T155 Series

iworx Air Side Application Wiring Guide

Commercial and Light Industrial Fire Alarm Control Panel

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

PROTECT SRB 200EXi-1A

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Oxygen (O2) Single-Point Gas Detection System

NXM2G Installation and Operating Manual

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

Transcription:

Notes: Warrick Series 67 Intrinsically Safe Multi-Function ontrol Installation and Operation Bulletin Form 670 Sheet P/N 100501-1 Rev. F Table of ontents Page 3 Page Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 1 Page 15 Installation Instructions: Safe Sensing ircuits- General Information - Mounting Location - Wiring Installation Instructions: Intrinsically Safe Sensing ircuits - Grounding - Sensor Wiring Installation Instructions: Intrinsically Safe Sensing ircuits Installation Instructions: Intrinsically Safe Sensing ircuits - Alarm hannel Wiring - Alternation ircuitry Installation: High Voltage ircuits - A Supply - Grounding - Output ontacts ontrol Diagram Technical Information - Specification - Ordering Information - Module Replacement Technical Information - Module Replacement - Single Level Service: ontact Operation - Single Level Service: Alarm Functions - Differential Level Service: Simplex - Differential Level Service: Duplex General ontrol Information Sample Wiring Diagram Gems Sensors Inc. One owles Road Plainville, T 06062-1198 Tel: 860-793-579 Fax: 860-793-580

Notes: Sample Wiring Diagram L1 Figure 5 L1 h N High Level h 3 N Low Level Alarm N Bell Ground G L2 L1 NO N Pump #2 Starter ircuit Pump #1 Starter ircuit NO N NO N NO N NO N Series 6710A ontrol hannel hannel 3 hannel 2 hannel 1 h h 3 h 2 H1 LED LED LED LED DIP Switch Alternate 2-1 1-2 Down Pump Up S G S3 HS2 G LS2 HS1 G LS1 2-1 1-2 G SIL Note: For applications that do not require duplex alternation, a jumper must be placed from G to 1-2 terminal Non-Hazardous Area Non-Hazardous Area Hazardous Area Silence Auto 1-2 2-1 Hazardous Area High Level Alarm Standby Pump Start Duty Pump Start 2 15 Pump(s) Stop Low Level Alarm

ontrol Diagram Figure 2 A Supply H 3/ Alarm G L2 L1 NO N * 3* 2* 1* * Form A & B contacts available Technical Information SPEIFIATIS ontact Design: Standard SPDT (1 form ): one normally open (N.O.) and one normally closed (N..), non powered contacts ontact Ratings for each channel. Optional 1 Form A (N.O.) and 1 Form B (N..) isolated ontact Ratings: Standard Form - 10A @ 120/20 VA resistive and 30 VD resistive, 1/3 Hp @ 120/ 20 VA. Optional Form A & B - 5A @120/20 VA and 30 VD resistive, 1/8 Hp @ 120/20 VA. Bell ontacts: 1 Form (N.O.), N.., ) Bell ontact Ratings: 10A @ 120/20 VA and 30 VD resistive, 1/3 Hp @ 120/20 VA ontact Life: Mechanical - 10 million operations. Electrical - 1,000,000 operations minimum at rated load. Primary Voltage: 120 or 20 VA models + 10% - 15%, 50/60 Hz. Supply urrent: Relays energized - 60ma @ 120 VA, 30ma @ 20 VA Secondary ircuit: 12 VA RMS voltage on probes, 6ma current RMS. Sensitivity: Models operate from 700-100,000 ohms maximum specific resistance Temperature: -0 to 150 F Ambient Electronics Module: Solid state components enclosed in a black nylon housing Terminals: Standard Form removable terminal strip containing a size pan head screw with a clamping plate. Will accept up to two (2) #1 AWG wires per terminal. Optional Form A & B relay board will accept up to one (1) #1 AWG wire per terminal. Use copper (60-75 ) wire only. Torque to 20 inch pounds. Listings: U.L. Intrinsically Safe (UL 913) File Number: E87112 NO N NO N NO N NO N ORDERING INFORMATI 67 X X X X X hannel hannel 3 hannel 2 hannel 1 h h 3 h 2 H1 LED LED LED LED DIP Switch Alternate 2-1 1-2 Down Pump Up A L A R M O N O F F 3 3 2 1 DIP Switch Blow Up I D M O D E A B D E.7K 10K 26K 50K 100K 1 2 120 VA 20 VA A MODULE REPLAEMENT 1 Form A & B (N.O.) & N.. Isolated) for each channel 1 Form (N.O., N..) for each channel 0 1 None NEMA 1 NEMA A D A on Probe ircuit D on Probe ircuit Non-Hazardous Area S G S3 HS2 G LS2 HS1 G LS1 2-1 1-2 G SIL If the electronic module needs to be replaced: 1. Turn off power to the control and load devices 2. Remove the metal partition located across the center of the module ( when required). Hazardous Area { { { h h 3 h 2 H1 Silence 3. Remove all field wiring terminal blocks from the electronic module. The field wires do not need to be removed from the terminal blocks. The terminal blocks separate from the board as show in figure 8-1. Sensors Note: For applications that do not require duplex alternation, a jumper wire must be placed from the G to 1-2 terminal. Auto 1-2 2-1. Remove the four () retaining screws from the base of the electronic module. The module can now be removed from the control panel. 5. Install a new module and reinstall all of the terminal blocks. 6. Reinstall the metal partition (when required). 7. Set all DIP switches according to previous instructions. 8 9

Technical Information: Module Replacement Installation: High Voltage ircuits Terminal Strip Removal Diagram 3 A.., Form ontacts and Sensor Terminals A.. SUPPLY: onnect the incoming supply HOT lead to the L1 terminal, NEUTRAL lead to the L2 terminal and EARTH GROUND lead to the G Terminal. Note: the incoming power supply should have the same electrical characteristics as indicated on the control s label. GROUNDING Terminal G on the supply line/load side terminal strip is a redundant system ground terminal and must be connected to the earth ground buss of the panel s A supply line feeder. OUTPUT TATS hannels 1-: Each channel has a dedicated non-powered contacts. These can be either Form or Form A & B depending on the model. These contacts will change state when their respective channel activates. In DIRET mode the relay will energize and the contacts will change state when the probe circuit sensor closes. In INVERSE mode the relay will energize and contacts will change state upon power up. The channel will then de-energize and return the contacts to their shelf state when the probe circuit sensor closes. Form - This contact configuration consists of one (1) Normally Open contact and one (1) Normally losed contact. There are three terminals for electrical connections, N.O., N.. and ommon. Each terminal will accept up to two (2) #1 AWG wires Separation Point Field wiring Form A & B: This contact configuration consists of one (1) Normally Open contact and one (1) Normally losed contact which are electrically isolated from each other. There are two terminals for each contact. Each will accept one (1) # 1 AWG wire. Alarm Bell: The alarm bell contacts are non-powered Form construction. This contact configuration consist of consists of one (1) Normally Open contact and one (1) Normally losed contact. There are three terminals for electrical connections, N.O., N.. and ommon. Each terminal will accept up to two (2) #1 AWG wires When the output contacts are used to drive loads they should be wired in series with the load. This series branch circuit should then be connected across a power source compatible with the load. See figure 1. Form A & B ontacts Terminal Strip Removal ontacts Figure 1 Alarm Bell ontacts Series 67 - Option A ontact Board Series 67 - Option ontact Board See Output Board Options N.. N.O. L1 L2 G hannel 1 hannel 2 hannel 3 hannel N.O. N.. N.O. N.. N.O. N.. N.O. N.. hannel 1 hannel 2 hannel 3 hannel N.. N.O. N.. N.O. N.. N.O. N.. N.O. Separation Point N.O. N.. N.. N.O. lose on Fault Open on Fault Hot Neutral Earth Ground Field wiring 1/8 Hp 120, 20 VA 5A @ 120/20 VA or 5 A @ 30 VD 1/3 Hp 120, 20 VA 10A @ 120/20 VA or 10 A @ 30 VD Open & lose on Fault ontacts Rated 1/3 Hp 120, 20 VA 10 A @ 120/20 VA or 10 A @ 30 VD 10 7

Installation: Intrinsically Safe Sensing ircuits ALARM HANNEL WIRING: SILENE IRUITRY: A normally open pushbutton is required for the Series 67 s alarm silence circuitry. The N.O. pushbutton must be connected to the SIL and G terminals. For more information about the operation of the silence circuitry consult the Alarm Operation section on page 11. NOTE: THE SILENE PUSHBUTT IS NETED TO THE INTRINSIALLY SAFE IRUITRY. THEREFORE THE PUSHBUTT AND ITS ASSOIATED WIRING SHOULD BE SEPARATED FROM THE N-INTRINSIALLY SAFE WIRING AND DEVIES. SULT GENERAL WIRING INFORMATI FOR MORE INFORMATI. ALARM DIP SWITHES: The alarm DIP switches for channels 3 and can be set to enable the bell contacts for one or both alarm channels. However, this does not disable the alarm contact for that channel. Table covers the DIP switch settings for various alarm conditions. Table DIP Switch Settings 3 3 3 3 Off - Down Off - Down On - Up Off - Down On - Up On - Up Off - Down On - Up Bell ontact Status hannel 3 - Off - Disabled hannel - Off - Disabled hannel 3 - On - Enabled hannel - Off - Disabled hannel 3 - On - Enabled hannel - On - Enabled hannel 3 - Off - Disabled hannel - On - Enabled ALTERNATI IRUITRY AUTO OR MANUAL: Series 67 s built-in alternator can be used to automatically alternate between two loads controlled by channels 1 and 2. However, the automatic alternation may be by-passed to become a manual operation. This can be accomplished with the use of jumper wires or a three position switch connected to the 2-1, 1-2 and G terminals. Table 5 covers the jumper connections for manual alternation. Refer to figure 1 for more wiring information on the wiring of the three position selector switch. NOTE: THE MANUAL ALTERNATI IRUITRY IS SIDERED INTRINSIALLY SAFE. THEREFORE THE SELETOR SWTIH, JUMPER WIRES AND THEIR ASSOIATED WIRING SHOULD BE SEPARATED FROM N-INTRINSIALLY SAFE WIRING DEVIES. SULT GENERAL WIRING INFORMATI FOR MORE INFORMATI INTRINSI SAFETY. Table 5 Alternation Status Automatic* Manual 1-2 Manual 2-1* Jumper Required None Terminals 1-2 to G Terminals 2-1 to G LED Status Pump-Down* Either No. 1** No. 2** LED Status Pump-Up* Either No. 1** No. 2** The Series 67 multi-function control can be used for many different applications including: pump control, solenoid valve control and alarm activation. The following instructions cover the most common applications. If your application is not included, contact Gems Sensors or our authorized representative in your area for assistance. The operating instructions are broken up into two general categories: SINGLE and DIFFERENTIAL LEVEL SERVIE. The alarm functions are covered under the SINGLE LEVEL SERVIE heading while the pumping and solenoid valve functions are covered under the DIFFERENTIAL LEVEL SERVIE heading. SINGLE LEVEL SERVIE: TAT OPERATI LOAD TATS: HANNELS 1- The activation of these contacts is dependent upon the type of sensor (normally open or closed) and the mode of operation (direct or inverse). The table 6 gives the sensor activation condition, DIP switch settings, contact status and LED status for various applications and sensors. Application High Level Alarm Normally Open Float High Level Alarm Normally losed Float Low Level Alarm Normally Open Float Low Level Alarm Normally losed Float High Level Alarm onductance Probes Low Level Alarm onductance Probes UNKNOWN SENSOR Normally Open UNKNOWN SENSOR Normally losed Warrick Sensor FE - Reed Switch Float for M Tilt Float FE - Reed Switch Float for M Tilt Float FE - Reed Switch Float for M Tilt Float FE - Reed Switch Float for M Tilt Float 3R, 3T, 3W, 3Y, 3H or 3S 3R, 3T, 3W, 3Y, 3H or 3S Table 6 Sensor Alarm Activation ondition Opens Opens on Falling Level loses on Falling Level Probes in ontact with onductive Liquid Probes not in ontact with onductive Liquid loses on Fault Opens on Fault SINGLE LEVEL SERVIE: ALARM FUNTIS DIP Switch Setting UP I DOWN D DOWN D UP I Invers UP I DOWN D UP I DOWN D Relay Status Upon Alarm LED Status Upon Alarm BELL TATS: Under NORMAL operating conditions the alarm bell relay is held energized. The relay will de-energize to activate an alarm device when an abnormal condition exists on either channels 3 and/or. Either one or both alarm bell circuits can be disabled by adjusting the alarm DIP switches. onsult table for more information on the bell DIP switch settings. 6 Notes * For non-alternation applications jumper 1-2 to G ** The position of the 1-2 and 2-1 indicating LED s is dependent on the application. The position changes for pump-up or pump-down. onsult control diagram figure 6-1 for more information. SILENE IRUITRY: Should an abnormal condition exist on either channels 3 and/or the normally closed (N..) alarm bell relay contacts will close, activating an alarm device. The N.. alarm bell contacts can be returned to their normal state (open) silencing the alarm, by depressing a normally open pushbutton connected to the SIL and G terminals. This will NOT affect the load contacts for channels 3 or as they act independent from the alarm bell contacts. 11

DIFFERENTIAL LEVEL SERVIE: The following operating instructions are based on correct DIP switch settings and sensor types. Any deviation from these requirements may result in incorrect system operations. onsult table 7 for further instructions. Application Simplex Pump-Down or Solenoid Valve Drain Simplex Pump-Up or Solenoid Valve Fill Duplex Pump-Down - ommon Pump Stop Duplex Pump-Up - ommon Pump Stop Duplex Pump-Down - Separate Pump Stop Duplex Pump-Up - Separate Pump Stop Warrick Sensor Table 7 DIP Switch Setting Down Up Down Up Down Up Activation ondition ontact Status N.O. - loses N.. - Opens N.O. - Opens N.. - loses N.O. - loses N.. - Opens N.O. - Opens N.. - loses N.O. - loses N.. - Opens N.O. - Opens N.. - loses LED Status Sensor losed Installation: Intrinsically Safe Sensing ircuits DIFFERENTIAL LEVEL SERVIE: hannels 1 and 2 are designed to provide differential on/off points to control pumps, solenoid valves or other equipment. These channels can also be used in single level service for alarms and cutoffs, however the control s built-in silence circuitry and bell contacts cannot be used. onsult the Alarm section for more information. When channels 1 and 2 are used for differential level service, the associated sensors must be normally open. The / DIP switches must also be set to the proper mode for each channel to achieve the correct operation. Table 3 gives the correct sensor to terminal connections an DIP switch settings for various applications. FOR APPLIATIS THAT DO NOT REQUIRE DUPLEX ALTERNATI, A JUMPER WIRE MUST BE PLAED FROM THE G TO 1-2 TERMINAL. Application Simplex Pump-Down or Solenoid Valve Drain** Simplex Pump-Up or Solenoid Valve FillII Duplex Pump-Down - ommon Pump Stop Duplex Pump-Up - ommon Pump Stop Sensor ontact Style Table 3 Sensor Terminal onnections Start Pump / Open Valve - HS1 & G* Stop Pump / lose Valve - LS1 & G* Start Pump / Open Valve - LS1 & G* Stop Pump / lose Valve - HS1 & G* Duty Pump Start - HS1 & G* Standby Pump Start - HS2 & G* Duty and Standby Pump Stop - LS1 & G* Jumper - LS1 and LS2 Duty Pump Start - LS1 & G* Standby Pump Start - LS2 & G* Duty and Standby Pump Stop - HS1 & G* Jumper - HS1 and HS2 DIP Switch Setting - Down hannels 1 or 2 - Up hannels 1 or 2 - Down hannels 1 or 2 - Up hannels 1 or 2 DIFFERENTIAL LEVEL SERVIE: SIMPLEX Duplex Pump-Down - Separate Pump Stops Duty Pump Start - HS1 & G* Standby Pump Start - HS2 & G* Duty and Standby Pump Stop - LS1 & G* Jumper - LS2 and G* - Down hannels 1 or 2 Simplex Pump Down- Should the level rise to the PUMP START sensor the N.O. load contacts will close starting the pump. The pump will remain running until the level recedes below the PUMP STOP sensor and the load contacts open. Duplex Pump-Up - Separate Pump Stops Duty Pump Start - LS1 & G* Standby Pump Start - LS2 & G* Duty and Standby Pump Stop - HS1 & G* Jumper - HS2 & G* - Up hannels 1 or 2 Simples Pump UP- Should the level recede below the PUMP START sensor the N.O. load contacts will close starting the pump. The pump will remain running until the level rises to the PUMP STOP sensor and the load contacts open. Solenoid Valve Drain- Should the level rise to the VALVE OPEN sensor the N.O. load contacts will close energizing the normally closed valve to open. The valve will remain open until the level recedes below the VALVE LOSE sensor and the load contacts open Solenoid Valve Fill- Should the level recede below the VALVE OPEN sensor, the N.O. load contacts will close energizing the normally closed valve to open. The valve will remain open until the level rises to the VALVE LOSE sensor and load contacts open. * Note 1: If conductance probes are being used, only one G connection is required. Terminal G must be grounded to the vessel if metallic. If the electrode fitting being used has a metallic body and is supported directly upon a metallic vessel, the ground connection is facilitated by securing that end of the ground connector beneath the head of one of the screws which fasten the terminal housing to the body of the fitting. When the vessel is non-metallic, terminal G must be connected to an additional electrode of length equal to or longer than, the longest electrode. If wire suspension electrodes are being used, more than one Ground/ Reference probe may be required. ** Note 2: This setup is based on the use of a Normally losed (N..) solenoid valve that energizes to open when power is applied to the coil circuit. 12 5

Installation: Intrinsically Safe Sensing ircuits GROUNDING: The four mounting holes on the Series 67 provide an electrical connection for earth grounding between the control s internal solid state circuitry and the enclosure chassis. To insure proper grounding, use only metal screws and lock washers when mounting this control. Terminal G on the supply line/load side terminal strip is a redundant system ground terminal and must be connected to earth ground buss of the control s A supply line feeder. Note: 1. Intrinsically safe terminals can be connected to any non-energy generating or storing switch device such as a pushbutton, limit or float type switch or any Warrick electrode and fitting assembly. 2. To prevent electrical shock from supply line/load side powered connections, the Series 67 should be mounted in a tool accessible enclosure of proper NEMA rated integrity. 3. For U.L. 913 Listed panels, a metallic partition may be necessary to provide adequate spacing between non-intrinsically safe and intrinsically safe wiring and /or terminals.. For additional guidance on Hazardous Location Installation and Intrinsically Safe Devices, consult ANSI/ISA standard RP 12-6 or NE articles 500-516 and local codes. SENSOR WIRING The Series 67 control has four independent intrinsically safe channels, which can be connected to different types of sensors including floats, conductance probes, pressure switches and other non-powered contacts or sensors. The connections of the sensors to the terminals will not vary with normally open or closed sensors. However, the / DIP switches must be set to the proper mode for each channel to achieve the correct operation. onsult tables 2 and 3 for the proper DIP switch setting for various sensors and functions. The following sections cover the intrinsically safe sensor connections for single and differential level service. SINGLE LEVEL SERVIE: All four channels can be used for single level service. Each channel is independent and can be used for its own single point function. However, only channels 3 and have the alarm bell and silence capabilities. onsult the alarm sections for more information regarding the installation and operation of the alarm circuitry. Table 2 covers the sensor style to terminal connections for all four channels. Table 2 Sensor Style Normally Open: loses on Alarm ondition Normally Open: Opens on Alarm ondition Terminal onnections hannel 1 - HS1 & G* hannel 2 - HS2 & G* hannel 3 - S3 & G hannel - S & G hannel 1 - HS1 & G* hannel 2 - HS2 & G* hannel 3 - S3 & G hannel - S & G DIP Switch Settings Mode - Up Position Mode - Down Position DIFFERENTIAL LEVEL SERVIE: DUPLEX PUMP DOWN WITH ALTERNATI ommon Pump Stop- The pumps will alternate each cycle with the duty pump starting when the level rises to the DUTY PUMP START sensor and stops when the level recedes below the PUMP(S) STOP sensor. If the duty pump fails or cannot meet the demand of the system and the level rises to the STANDBY PUMP START sensor, the standby pump will be started and will continue in operation until the level recedes below the PUMP(S) STOP sensor. Separate Pump Stops- The pumps will alternate each cycle with the duty pump starting when the level rises to the DUTY PUMP START sensor and stops when the level recedes below the DUTY PUMP STOP sensor. If the duty pump fails or cannot meet the demand on the system and the level rises to the STANDBY PUMP START sensor, the standby pump will be started and will continue in operation until the level recedes below the STANDBY PUMP STOP sensor. DIFFERENTIAL LEVEL SERVIE: DUPLEX PUMP UP WITH ALTERNATI ommon Pump Stop- The pumps will alternate each cycle with the duty pump starting when the level recedes below the DUTY PUMP START sensor and stops when the level rises to the PUMP(S) STOP sensor. If the duty pump fails or cannot meet the demand of the system and the level recedes to the STANDBY PUMP START sensor, the standby pump will be started and will continue in operation until the level rises to the PUMP(S) STOP sensor. Separate Pump Stops- The pumps will alternate each cycle with the duty pump starting when the level recedes to the DUTY PUMP START sensor and stops when the level rises to the DUTY PUMP STOP sensor. If the duty pump fails or cannot meet the demand on the system and the level recedes to the STANDBY PUMP START sensor, the standby pump will be started and will continue in operation until the level rises to the STANDBY PUMP STOP sensor. DIFFERENTIAL LEVEL SERVIE: DUPLEX PUMP DOWN WITHOUT ALTERNATI Same operation as above disregarding the alternation sequence. Use appropriate jumper to determine manual pump start sequence. Refer to table 5 for the manual alternation jumper information. DIFFERENTIAL LEVEL SERVIE: DUPLEX PUMP UP WITHOUT ALTERNATI Same operation as above disregarding the alternation sequence. Use appropriate jumper to determine manual pump start sequence. Refer to table 5 for the manual alternation jumper information. Normally losed: loses on Alarm ondition Normally losed: Opens on Alarm ondition hannel 1 - HS1 & G* hannel 2 - HS2 & G* hannel 3 - S3 & G hannel - S & G hannel 1 - HS1 & G* hannel 2 - HS2 & G* hannel 3 - S3 & G hannel - S & G Mode - Up Position Mode - Down Position * Note: hannels 1 & 2 cannot activate the alarm bell contacts and do not have the silence/acknowledge capabilities 13

General ontrol Information Installation: Intrinsically Safe Sensing ircuits Figure See notes 1, 3 & 5 See notes 1 & 3 Sensor Sensor 3 Sensor 2 Sensor 1 This bulletin should be used by experienced personnel as a guide to the installation of the series 67. Selection or installation of equipment should always be accompanied by competent technical assistance. We encourage you to contact Gems Sensors or its local representative if further information is required. IMPORTANT: BEFORE PROEEDING TO INSTALL AND WIRE THE SERIES 67 TROL, READ AND THROUGHLY UNDERSTAND THESE INSTRUTIS. Series 67 - Option A ontact Board Series 67 - Option ontact Board Seal Off Fitting See note SIL G 1-2 2-1 LS1 G HS1 LS2 G HS2 S3 G S N.. N.O. L1 L2 G When installing according to these instructions, this device provides intrinsically safe sensing circuits for interface into lass I; Groups & D, lass II; Groups E, F, & G and lass III; Hazardous Areas. Electrical equipment connected to associated apparatus should not exceed maximum ratings marked on product. *** WARNING: To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. hannel 1 hannel 2 hannel 3 hannel N.O. N.. N.O. N.. N.O. N.. N.O. N.. Notes: N.O. N.. 1/8 Hp 120, 20 VA 5A @ 120/20 VA or 5 A @ 30 VD hannel 1 hannel 2 hannel 3 hannel N.. N.O. N.. N.O. N.. N.O. N.. N.O. N..N.O. 1. All intrinsically safe wiring must be installed in accordance with article 50 of the National Electric ode, publication ANSI/NFPA 70 or E, Part 1 as applicable. 2. Grounding- The four mounting holes on the Series 67 provide an electrical connection for earth grounding between the controls internal solid state circuitry and the enclosure chassis. To insure proper grounding, use only metal screws and lock washers when mounting the control. Terminal G on the supply line/load side terminal strip is a redundant system ground terminal and must be connected to the earth ground buss of the controls A.. supply line feeder. The resistance between the system ground terminals and the earth ground buss must be less than 1 ohm. To prevent electrical shock from supply line/load side powered connections, the Series 67 should be mounted in a metal enclosure of proper NEMA integrity. 3. The maximum total length of all of the intrinsically safe wiring (of each conductor) shall not exceed an accumulative value of 16,000 feet, excluding any ground wiring.. The intrinsically safe terminals of the Series 67 can be connected to any non-energy generating or storing switch device such as a push button, a limit or float type switch or any of Warrick s electrode fitting assemblies. 1/3 Hp 120, 20 VA 10A @ 120/20 VA or 10 A @ 30 VD 5. When wiring alternation and bell silence switches, the switches and wiring must be separated from nonintrinsically safe circuits and wired in accordance with article 50 of the National Electric ode, publication ANSI/NFPA 70 or E, Part 1 as applicable. lose on Fault Open on Fault Hot Neutral Open & lose on Fault ontacts Rated 1/3 Hp 120, 20 VA 10 A @ 120/20 VA or 10 A @ 30 VD Earth Ground MOUNTING LOATI The control must be situated in a non-hazardous area where an explosive atmosphere will not exist at any time; otherwise, it must be mounted in a suitable U.L. approved explosion-proof enclosure with suitable U.L. approved explosion-proof seals. WIRING: GENERAL INFORMATI 1. Intrinsically safe wiring must be kept separate from non-intrinsically safe wiring. 2. Intrinsically safe and non-intrinsically safe wiring may occupy the same enclosure or raceway if they are at least 2 inches (50mm) apart and separately tied down. Inside panels, field wiring terminals for intrinsically safe circuits must be separated by at least 2 inches (50 mm) from non-intrinsically safe wiring. 3. Wire the control device(s) to the Series 67 relay as shown in figure 1. A separate rigid metallic conduit should be used to enclose the conductors of the intrinsically safe control circuit.. An approved seal should be used at the point where the intrinsically safe control circuit wiring enters the hazardous area. 5. apacitance and inductance of the field wiring from the intrinsically safe equipment to the associated apparatus shall be calculated and must be included in the system calculations as shown in Table 1. able capacitance, cable, plus intrinsically safe equipment capacitance, i must be less than the marked capacitance, a (or o), shown on any associated apparatus used. The same applies for inductance (Lcable, Li and La or Lo, respectively).where the cable capacitance and inductance per foot are not known, the folllowing values shall be used: cable = 60 pf/ft., Lcable = 0.2 µh/ft. For intrinsically safe output wiring use #1 or #16 AWG type MTW or THHN wire. By using these wire types in conjunction with the following distance recommendations, you will not exceed the maximum capacitance for field wiring. Use Table 2 as a guide for maximum wire runs. Table 1 1 3 SIL,G,1-2,2-1 LSI,G,HSI,LS2 S3,G,S HS2,G I.S. Equipment V max (or Ui) I max (or Li) P max, Pi i + cable Li + Lcable Terminals Entity Parameters Voc Isc Po 12.82 Vdc 12.82 Vdc 12.82 Vdc 12.82 Vdc > > > < < 7.2 ma 7.62 ma 2.5 ma 5.08 ma Associated Apparatus Voc or Vt (or Uo) Isc or It (or lo) Po a (or o) La (or Lo) 2.5 mw 2.5 mw 8.2 mw 16.3 mw a 6.5 µf 6.5 µf 6.5 µf 6.5 µf La 100mH 100mH 100mH 100mH Model Number 67AXXXA 67BXXXA 67XXXA 67DXXXA 67EXXXA Table 2 Sensitivity.7K Ohms 10K Ohms 26K Ohms 50K Ohms 100K Ohms Distance,000 Feet 2,00 Feet 1,200 Feet 600 Feet 300 Feet