Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Fluke-Direct.com

Similar documents
Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance.

Compliance without compromise Safety without sacrifice

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

CAP Series ,,,,, The Clear Choice. CAP Series Features: Who Says Infrared Windows Have to be Round? Certifications:

INFRARED WINDOW SERIES

Safety requirements for voltage testing instruments

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

INSPECT & MONITOR 24/7 SOLUTIONS FOR ELECTRICAL CABINETS. IR Windows & AX8 Thermal Imaging Temperature Sensor

How to spot and address potential process problems using thermal imaging

MT4 MAX/MT4 MAX + Infrared Thermometer

62 MAX/62 MAX + Infrared Thermometer

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

62 MAX/62 MAX + Infrared Thermometer

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

Infrared Thermometer. Getting Started

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

Infrared Thermometer

Spotting and addressing potential process problems using thermal imagery Application Note

SEL Arc-Flash Solutions

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?

SEL Arc-Flash Solutions

infrared inspections efficient solutions. focused results.

Arc Flash Protection Training - NFPA 70e Electrical Safety

Common Misconceptions Relating to Infrared Inspection Ports

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

VPFR. cma. Product Brochure. Industrial-Grade Infrared Inspection Viewing Panes

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com

700G Series. Pressure Gauge. Safety Information

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

Users Manual. Air Velocity Meter

IR Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows

White Paper. OSHA and NFPA 70 Understanding NFPA 70 and its. Implications in Electrical Inspections Abstract: iriss.com

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

Electrical Preventive Maintenance (EPM) Program

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

Predictive Maintenance Training

Enhancing Current Maintenance Practices 04. Managing the Risk 06. Constant Monitoring of Electrical Enclosures 08

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

LUXEON Rebel. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON Rebel Photobiological Safety Report

Hazardous Area Ringdown Telephone

White paper. OSHA and NFPA 70 Safer by Design The History of IRISS. Infrared Windows. Abstract: iriss.com

Delta T Alert: Wireless Temperature Monitoring of Electrical Enclosures

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

ENCLOSURE COOLING. Glossary

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

White Paper. Maintenance Inspection Windows on Transformers. Maintenance Inspection Windows on Transformers. Abstract: iriss.com

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Installation, Operation & Service Manual

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

Quality. Trust. Value. Safety.

Electrical Safety Compliance: NFPA 70E

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

GARN WHS 3200 Addendum to the Owner s Manual

Cabinet Cooler Systems

How to reduce exposure to arc flash hazards

Operator s Manual. IP-100 Immersion Probe Cooler

Infrared Windows and Arc Ratings: Dispelling the Myth of Arc-Resistant IR Windows

Flame Simulator User Manual. Publication Rev. A

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

Product Specifications MaxLumen MRI LED Diffused Lighting

Precision Infrared Thermometer. Users Manual

Design Manual Installation Operation Maintenance

Non Ionizing Radiation Audit checklist

Electric Submersible Pumps

SECTION INTERIOR LIGHTING

Lloyd s Register Type Approval System Test Specification Number 3

Adam Equipment. NCSA 20plus. (P.N Revision B - September 2012)

Open-area Smoke Imaging Detection (OSID)

A WORLD WITHOUT DOWNTIME

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

Webinar November 12, 2014

64 Max IR Thermometer

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

Declaration of Conformity

SSL Light Engines. SSL Light Engines Chuck Berghoff, President & CEO

C1N & C2N SERIES Fluid heating for light industrial applications

The Signal Is Clear TM

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

Vibratone Horns. Models 350 and 450

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Securitron. Switching Power Supplies

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Rutgers Environmental Health and Safety (REHS)

Eseta. Architectural LED Wall Sconce. Area lighting for outdoor wall-mounted applications.

Transcription:

ndustr Proce Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Electric Outdoor/indoor any voltage, arc-tested Indoor medium voltage Indoor low voltage info@ Available in three models

IR windows engineered to live up to the Fluke name Fluke Infrared (IR) Windows make it easier to comply with the NFPA 70E safety standard. Their arc-resistant crystal optics are engineered and tested to withstand the extreme pressures and temperatures of an electric arc-fault event up to 50 ka. Their unique Kwik Twist magnetic security cover further protects the viewing pane from accidental external impact, and is locked in place with a security access key. For added convenience, the Kwik Twist cover magnetically sticks to the metal panel. Even more remarkable is their AutoGround feature, exclusive to Fluke, that automatically grounds the Fluke IR Window upon installation, without any additional steps or testing. The Auto- Ground feature enhances worker safety and eliminates the need to separately ground each metal component of the window. The clear advantage for thermal imaging Fluke offers three IR windows, all of which are UL and CSA certified. The CLKT is certified for use both outdoor and indoor. CLKTO and CLV are certified for indoor use. All models feature the exclusive Fluke ClirVu coating that seals the entire crystal optic including the edges making it impervious to moisture and vibration and protecting it from the aging effects of UV exposure. ClirVu optics are insoluble and guaranteed never to degrade even when exposed to mild acids or alkalis. Of the thousands of Fluke CLKT IR Windows installed many in very challenging environments not one has been returned due to moisture or transmission degradation. The antistatic properties of the ClirVu coating also help repel dust and grime to keep both sides of the window clean for better IR transmission. As a result, Fluke IR Windows transmit up to 96 percent of the energy emitted, producing a more detailed image. Not only do Fluke IR Windows deliver a clearer view of the equipment being inspected, they also present a larger viewing area than other windows on the market. Since the entire area of the crystal optic is available for infrared transmission, it provides optimum repeatable results. It also provides a better view for visible light inspections. Industrial, mechanical, electro-mechanical and general building maintenance. ndustr Proce Process, refractory insulation, tank and vessel levels, steam systems and traps, pipes and valves, etc. Electrical, unbalanced loads, overloaded systems, wiring mistakes-or component failure, etc. 4 info@ lectric

Maximum inspection flexibility Fluke is the only IR Window with Quadraband multispectral optics that support most popular camera brands and IR, UV, and visual inspection modes. That means you can change your camera without having to change your IR Windows. Quadraband optics transmit electromagnetic radiation in: Longwave infrared Midwave infrared Visual UVA and UVB ultraviolet So whether you use longwave thermal imagers, midwave thermal imagers, corona/uv cameras, or traditional visual cameras, you can take full advantage of the state-ofthe-art Fluke IR Window features. Increased efficiency, decreased costs Fluke IR Windows can save costs every step of the way. It takes just one person about 10 minutes to install a Fluke IR Window. This helps to minimize installation labor costs and system downtime. Just power down, remove the panel cover, position the window using the included template, drill the hole, and affix the window with three self-tapping screws. Because all the mounting hardware attaches to the outside of the panel there are no parts inside that can work loose and cause a short. Once installed, Fluke IR Windows increase efficiency because maintenance professionals can perform inspections quickly without requiring electricians to reduce the power and remove the panel cover. Inspections through IR Windows are conducted at full power, so you don t lose any production time. The decreased arc-flash risk provided by Fluke arc-resistant, ClirVu coated optics also may reduce insurance costs. Enhance the indoors and Fluke CLKT IR Window for outdoor/indoor applications 50 ka arc-tested Backed by the first name in preventive maintenance With Fluke IR Windows you get more than a premium quality product guaranteed for the life of the equipment. You also get a strong support network to work with you before, during, and after the sale. Whether you need help starting an IR inspection program, planning your IR Window installation, or installing your IR windows, Fluke expertise is just a phone call away. Fluke CLKTO IR Window for indoor medium voltage applications up to 38 kv 5 info@ Fluke CLV IR Window for indoor low voltage applications up to 600 V

safety and speed of IR inspections outdoors Quick installation Fluke CLKT IR Windows for outdoor/indoor high voltage applications Whether your electrical inspection program takes you to the temperature extremes of a northern Canadian winter or the California desert, the corrosive conditions of offshore oil rigs, or anywhere in between, you can count on Fluke CLKT IR Windows to stand up to the challenge. With their heavy-duty aluminum housing and arc-flash resistant design you ll find they perform their best under even the worst conditions to increase the speed and safety of your IR inspections. Here s why: Engineered and tested to withstand an electric-arc up to 50 ka for 30 cycles. Certified by UL and CSA for Type 3/12 outdoor environments in North America Certified by SIRA IP65 for outdoor environments in Europe Tested to withstand long term aging effects of UV exposure Available in 2, 3, or 4 inch diameters Equipped with an identification plate to provide unique onsite numbering for rapid location and faster repairs. Includes a security access key, installation instructions, and selfadhesive drilling template Fluke CLKTO IR Windows for indoor medium voltage applications The Fluke CLKTO IR Window was designed specifically for installation on indoor equipment. It includes the exclusive Fluke ClirVu coating, Quadraband optic technology, and AutoGround installation of our outdoor IR Window, along with specific features appropriate for indoor applications. Features a 3 inch diameter impact-resistant viewing pane that complies to ANSI C37.20.2 for indoor switchgear up to 38 kv Holds environmental certification that meets and exceeds UL50/ NEMA Type 1 certification for use in indoor environments in North America Tested to withstand the long term aging effects of UV exposure Includes an identification plate for unique, onsite numbering for rapid location and faster repairs Comes complete with a security access key, installation instructions, and self-adhesive drilling template. Fluke CLV IR Windows for indoor low voltage applications For equipment up to 600 V Industry s first IR Window tested to UL1558 Standard for Low Voltage Switchgear Available in 3 in diameter Certified by UL and CSA for Type 1 indoor use only Position with template Drill hole Peel to expose self adhesive Affix the window 6 info@ For detailed installation see the UL validated installation instructions supplied with each IR Window.

Why open enclosures and expose yourself to arc flash hazards when you don t have to? Infrared (IR) thermography is a critical technology in successful preventive maintenance programs for electrical systems. By measuring the amount of heat emitted from electrical components, maintenance professionals can detect malfunctions before they cause a major failure. However, by inspecting live equipment, technicians expose themselves to the potential danger of an arc flash, electric shock, or explosion every time they open a panel cover. To address that hazard, in 2012 the NFPA 70E Standard for Electrical Safety in the Workplace, (the leading internationally recognized workplace standard) was revised by the National Fire Protection Association (NFPA) to reduce the risk to workers in arc-flash hazard zones. Installing properly certified IR windows to inspect switchgear and motors can make it easier for companies to comply with NFPA 70E because IR windows allow a technician to inspect the equipment without removing the panel cover reducing the exposure risk. This reduced exposure risk may also reduce the amount of personal protective equipment (PPE) that the inspector must wear. Please consult PPE regulations to obtain accurate requirements for your environment. Make the safer choice with Fluke IR Windows Before choosing an IR Window you need to consider several factors: where it will be installed; what conditions it will be exposed to; how many people are required to install it; and any certifications it holds. When you choose a Fluke IR Window you re making a safer choice related to all of those concerns. For more than 60 years Fluke has led the way in engineering durable, reliable, and accurate tools for industrial troubleshooting and preventive maintenance. In 2009 Fluke extended that commitment to IR windows when it acquired Hawk IR International the world leader in infrared windows and other safety products. Hawk IR Windows set the standard for safety, performance, and dependability with several innovations, including, the first supplier to offer a 50 ka arc-resistant IR Window. Fluke is still the only supplier that offers: UL- and CSA-recognized window with ClirVu technology Totally insoluble ClirVu crystal optic IR window Revolutionary AutoGround safety system Now part of the Fluke family, these IR Windows provide a clear view of motors and switchgear through infrared, ultraviolet (UV), and visible light inspections. You ll find Fluke IR Windows in a broad range of applications from industrial plants to commercial buildings, from hospitals to electric and water utilities. These windows provide a combination of exclusive features that deliver a higher level of safety, performance, and efficiency than any IR Window on the market. 1 info@

General specifications Outdoor/indoor, any voltage, arc tested Indoor, medium voltage Indoor, low voltage FLK-50-CLKT FLK-075-CLKT FLK-100-CLKT FLK-075-CLKTO FLK-075-CLV Crystal insert diameter 50 mm (1.97 in) 75 mm (2.96 in) 100 mm (3.94 in) 75 mm (2.96 in) Viewing aperture diameter 43 mm (1.7 in) 68 mm (2.7 in) 89 mm (3.5 in) 68 mm (2.7 in) Viewing aperture area 1452 mm2 (2.25 sq in) 3632 mm2 (5.63 sq in) 6322 mm2 (9.79 sq in) 3632 mm2 (5.63 sq in) Thickness 2 mm (0.08 in) 4 mm (.16 in) 2 mm (0.08 in) ClirVu Coating Yes Arc-tested 50 ka for 30 cycles @ 60Hz (IEEE C37.20.7) Voltage limit Any 38 kv 600 V Shortwave IR, Midwave IR, Longwave IR, Ultraviolet (UV) capable Yes Visual and fusion capable Yes Maximum Gaskets 250 C (482 F) Temperature Body 659 C (1218 F) 200 C (392 F) Optic 1400 C (2552 F) Viewing pane 150 C (392 F) UL rating UL 50 environmental Type 3/12 Type 1 UL746C N/A polymer free Yes UL94 N/A polymer free Yes UL1558 Yes CSA rating Environmental Type 3/12 Type 1 IP Rating IP65 Lloyd s Register Up to 11 kv marine switchgear, indoor or outdoor (offshore only) Pull out strength Up to 1388 lb (630 kg) Warranty Lifetime replacement against manufacturing defects For more detailed specifications download datasheets at www.fluke.com\irwindows Frequently asked questions about IR windows Q. Aren t IR windows that are made of polymeric materials more durable than those made of crystal? A. No. Polymer IR Windows can t withstand the high temperatures and pressure of an arc-flash and therefore could become a molten projectile. In addition, polymeric materials can degrade over time due to UV exposure, making them brittle and easily broken. Fluke IR Windows feature arc-resistant crystal optics designed to withstand an electric arc flash up to 50 ka for 30 cycles. Q. Won t a crystal optic absorb moisture and degrade over time? A. Not if the crystal optic is protected. Fluke ClirVu coating seals the entire optic even the edges making it insoluble and guaranteeing it never to degrade from moisture, or exposure to mild acids, alkalis, or UV rays. Q. Why do I need an IR window for my low voltage equipment? A. Arc-flash is not based only on the voltage level of your equipment. After conducting an arc-flash hazard analysis, as called for by the NFPA 70E safety standard, you may find that the available fault current on your low-voltage equipment is as high, or higher, than on your medium and high-voltage equipment. Q. If all IR windows meet safety standards why shouldn t I pick the one with the lowest cost? info@ A. All IR windows do not have the same certification, which means that they offer different levels of risk reduction. Some are certified for indoor use only and so do not offer the same degree of risk reduction for outdoor applications. One of the most widely accepted testing laboratories for electrical equipment is Underwriters Laboratories (UL), which has standards and codes that apply to all types of electrical components, including IR windows. All Fluke IR Windows hold the UL50 environmental rating CLKTO and CLV meet the UL50 Type 1 rating (indoor) and the CLKT has the UL50 Type 3/12 rating (outdoor). These ratings recognize Fluke IR Windows for maintaining their integrity in the environment for which they are designed. Q. Will installing an IR window in my electrical panel derate the environmental integrity of my equipment? A. As long as you match the NEMA/UL50 rating of the equipment with the NEMA/UL50 rating of the IR window and install according to the instructions included with the product, you will not derate the environmental integrity of the cabinet. Fluke IR Windows are UL Recognized for installation in indoor (CLKTO and CLV) and indoor and outdoor (CLKT) equipment. Q. Where do I install IR windows in a panel? A. The IR window s field of view varies based on window size and distance to target. For detailed information on field of view, please visit, www.fluke.com/irwfov Fluke. Not just infrared. Infrared you can use. TM Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com 2010-2012 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 4/2012 3839848E_EN Modification of this document is not permitted without written permission from Fluke Corporation.