Electric Process Heaters & Engineered Systems

Similar documents
Company Info. Quality. Personnel. Cartridge Heaters Strip Heaters. Screw Plugs Heated Tanks. Duct Heaters Flanged Heat. Blower Packages Pump Systems

Nuclear Electric Heating

TEMPERATURE CONTROL POWER COMPRESSED AIR EMERGENCY OR PLANNED, SHUT DOWN OR TURN AROUND. 24/7/ / ers-cat.com

Process Systems. Line Heaters. Heat Transfer Systems. Specialized Water Treatment Systems. Fuel Gas Conditioning Systems.

Circulation Heaters Selection Guidelines

COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS / AIR COOLERS

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

INTEGRATED FLOW SOLUTIONS TECHNICAL SPECIFICATION. IFS-607A rev.7 FOR INDUSTRIAL GRADE ELECTRIC PROCESS HEATERS

Tankless On Demand Electric Water Heater

Circulation Heaters Selection Guidelines

CAST-X Circulation Heater. CAST-X 2000 is a very versatile heater, with multiple housing, standoff, control and enclosure options.

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

TEMPERED WATER. Solutions for Safety Showers

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

Hazardous Area Portable Fan Heater The Bulldog

PROCESS HEAT PROCESS HEAT.

Hazardous Area Portable Fan Heater The Bulldog

INDUSTRIAL WATERTUBE BOILERS

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

First Line of Safety: Farris Engineering

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

Rental Boiler Specifications (Nebraska Boiler)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Hazardous Area Portable Fan Heater The Bulldog

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Burner Comparisons. Typical Competitor s Burner

Immersion Heaters. Screw Plug Immersion Heater

Industrielle Elektrowärme GmbH. OhmEx. Company Presentation. Dipl.-Ing. Wolfgang Vogler (GM)

CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

CNG. PSB Industries. NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R

SECTION HEATING BOILERS

Comfort. Description. Applications

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

VIEW. Matters. Magnetic Level Indicators Series. with. indicator. The. 200º viewing angle. 200º viewing angle

Our. Heaters. for your Projects

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Tube skin temperature sensors for surface measurement

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

Company History. In 2013 Eemax merges with the retail manufacturer Ecosmart.

470 Series Stamped Stainless Steel Pumps

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Capacity: 1.5 to 6.0 Ton

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Capacity: 1.5 to 6.0 Ton

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Cata-Dyne LH Line Heater & Micro Line Heater

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

ue short form catalog Leaders in Safety, Alarm & emergency Shutdown

SECTION DOMESTIC WATER HEATERS

SECTION PLUMBING EQUIPMENT

Section 4. ThermalEx - Certified Hazardous Area Heaters

EXPERIENCE UNMATCHED UNMATCHED EXPERIENCE. Precision Electric Heat and Control Systems for the Wastewater Industry

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

MODELS B1PA024, 030 AND 036

Oil & Gas Oil & Gas. Control. every move. Directional Control Valves & Regulators Pressure Switches Temperature Switches Level Switches

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

Circulating Water Temperature Controller

RTXP2 Series - Division 1 OR 2 / Zone 0, 1,OR 2

Revitalize Building Mechanical Systems (4619)

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

BUDERUS. Superior Equipment by Design. Comfortable. Efficient. Intelligent Heating. BUDERUS. G Cast Iron Commercial Boilers

your source for electric heating and controls

GENERAL CAPABILITIES

Environmentally Safe No Emissions

T urnk urnk y fabrica tion y fabrica Opera per tions and main tions and main enanc enanc services vic Subsea componen Subsea c

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

Oil & Gas Oil & Gas. Control Control. every move. Directional Control Valves & Regulators Pressure Controls Temperature Switches Level Controls

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

AND NATURAL GAS DRILLING AND PRODUCTION

HIGH EFFICIENCY COMMERCIAL BOILERS

ENERGY, OIL & GAS. astsensors.com macrosensors.com. Transducer & Transmitter Capabilities. Your sensor business partner...

Biomass Pellet Boilers

The Real Time Suppliers...

Explosion-Proof Forced Air Unit Heater - XGB

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Tubular Industrial Process

Cr.22 WIRE PROCESSING MACHINE FEATURES. Convenient Tool Cart Solution reduces set-up time and improves throughput

A2S s Company Profile

Instrumentation and Controls Group

VACPB1 Series - 60 Hz Models

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

The world s standard in efficiency. CBEX FIRETUBE

Products for. Nuclear Power Applications

Commercial Heating Products. Our products do more in a wide range of applications. Expect More.

Laser Level Measurement Products. Introducing the New LLT100

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

TM Series. Induced Draft, Counter Flow Optional Accessories

AAF International. Power & Industrial Overview. Presenter: TBC Date: 16 th November 2015

Tubular Industrial Process

Indirect Fired Water Heater

Explosion-Proof Forced Air Unit Heater - XGB

PETROCHEMICAL PROCESSING

Transcription:

Celebrating 50 Years Electric Process Heaters & Engineered Systems

Company Info aumer Process is a world leader in the design and manufacturing of electric heaters, controls and engineered Gsystems, since 1962. Solutions are provided according to all international rules and regulations. Engineering Optimized solutions CFD & FEA (mechanical & thermal) analysis Hysys process simulation 3D plant modeling Flow modeling Extensive material testing Dedicated R&D group Registered professional engineers Innovation Industry firsts 1975 safety contactor for heater control 1978 manual reset for heater OTC 1982 buffer tank for hot oil system longevity 1983 control panel external heat sink Patents Infi-seal heater moisture protection 7,554,064 Renewable heater standoff housing 7,318,745 4160 volt electric resistance heaters 7,372,007 Fuel gas conditioning multiple Optimized heat transfer (AT technology) pending Subsea hydrate remediation & prevention pending Low flow gas heater - pending 2

Quality ASME VIII Div 1 CSA ASME IX GOST ATEX IECex AWS D1.1 ISO 9001 CRN UL Service Facility State of the art campus in Houston, Texas USA 14,000 sq ft heater fabrication & test, two 7 ton cranes 10,000 sq ft control panel fabrication & test, air conditioned 16,000 sq ft precision machine shop two 5 ton cranes 24 ft. hook 46,000 sq ft systems fabrication two 20 ton & four 5 ton cranes 30 ft hook 20,000 sq ft office space 4160 volt heater test bed Expedited design and manufacturing Repair all manufacturersʼ electric heaters Experienced project management Dedicated field start-up & commissioning assistance Large spare parts inventory for immediate shipment Export crating and delivery 3

Flanged Heaters Renewable, high temp standoff housing 4160 volt, 1 MW heaters in electric boiler Subsea heater - 4160 volt, 5000 psi Submersible asphalt heater 4

Flanged Heaters Fuel gas heater with snow roof 36 heater for oxygen service Angled turbulators - optimum heat transfer 4160 volt housing with radiant shield 5

Circulation Heaters ASME certified for non-hazardous NACE compliant for sour service NEMA 7, 1MW, CRN ATEX certified for Middle East Offshore production platform 415 volt with oversized housing 6

Hot Oil Systems Multi-zone for Class 1 Div 1 Single zone, 100% SCR for extruder plant Dual zone, canned motor pump, hazardous location Dual zone, mag drive pump for petrochemical Rental fleet for immediate delivery 7

Fuel Gas Conditioning Mobile, trailer mounted FGCs - 13MW turbines Upgrade to satisfy California emission standards Nigerian compressor station Designed and delivered in 6 weeks 8

Fuel Gas Conditioning Onshore oil production - 45MW turbine Australian power plant - 100MW turbine Major U.S. medical center - 43MW turbine Peaking power generation - 60MW turbine 9

Control Panels SCR control NEMA 4X purge with sun shield UL certified 10

Control Panels Russian oil production - built to international standards Hazardous location Custom for hydrotest chamber Power plant - multi-mw with air conditioning 11

Engineered Systems Liquid fuel forwarding Seal gas conditioning U.S. Coast Guard 400 gallon shipboard use Liquid fuel conditioning 12

Engineered Systems Multi zone hot air Band heaters - hydrotest chamber Dowtherm vaporizer Fuel gas, double block & bleed 13

Specialty Heaters Screw plug heaters Duct heater Over-the-side heater Low flow gas heater Cartridge, band, enclosure, strip, finned strip, formed tubulars 14

Controls / Wire High temp wire, heat trace, thermocouple, thermowell, heat detector, thermostat, temperature controller 15

Cat. No. 600 Since 1962 www.gaumer.com sales@gaumer.com Ph: 713-460-5200 13616 Hempstead Road Houston, Texas 77040 Copyright 2012 Gaumer Company, Inc. All rights reserved. Specifications and information to change without notice. Printed in U.S.A.