Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Similar documents
ANALOX 3000 Carbon Monoxide Monitor

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

10yr O2NE & Safe-Ox. User Manual

Commercial in Confidence

Analox Safe-Ox/Safe-Ox He

Ax60+ Multi-Gas. Service Manual

Installation and user manual for the BiWire / Conventional Repeater Panel

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Flopurge TS. Operation Manual

SDA. User Manual. Analox Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Flostop TS D7E and A8E. Operation Manual

Installation, Operating and Maintenance Manual

RE-PR3-E-27 3-Phase Panel Mount 27kW

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

aspida User Manual T: +44 (0) F: +44 (0) W: E:

Pump-Up Controller MODEL 4062

SIL725 Safety Annunciator

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Two-Channel Gas Controller

Analog Room Pressure Monitor RPC Series

Oxygen (O2) Single-Point Gas Detection System

WIO200 Water In Oil measuring instrument

Pump-Down Controller MODEL 4052

Multi-Gas-Controller MGC2

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

Loadstar AC/DC Systems

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Aspida. User Manual. Commercial in Confidence

PTE0705 Electric Fence Monitor

GL-CO-RFG Channel Gas Leak Alarm System

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Carbon Monoxide Transmitter

ST Wiring diagram. Product description. Standard temperature controller. Order number

REGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS)

Beacon 800 Gas Monitor Operator s Manual

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

TEMPERATURE CONTROLLER (STANDARD MODEL)

Danfoss gas detection units

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Pioneer-R16 Gas Monitor Operator s Manual

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Model 1062 Environment Monitor

Beacon 110 Gas Monitor Operator s Manual

Software Version 2.01 LEVEL MONITOR MODEL 220

G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors

Ax60+ Multi-Gas, Quick Connect Option

Installation Manual Tracker 221

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Environmental Monitoring & Control Units Types MCU 3 & 4 Installation and Hardware

System 9000TS Event Recorder

Model 4001 Series Single Channel Controller

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Intelligent Security & Fire Ltd

Operation and Maintenance Manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

USER MANUAL Digital CO Monitor Model CO30

1 4 DIN Dissolved Oxygen Controller

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

Superdew 3. Hygrometer. Operating Instructions

ESSEX ENGINEERING CORPORATION

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

WIO 200B and WIOI200B Water in oil sensor

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

CO2 & Oxygen Monitor Operating Instructions Model: RAD

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Mark 25 Ultrapure Water Conductivity Analyzer

Ax60+ Kiosk Option. Quick Start Guide

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

KANE-ALERT-CO 2 Monitor with Temperature

IGD.CO.UK

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

RF Programmable Room Thermostat Installation Instructions

Introduction. OM-THA2

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

S/601 Controller Installation Manual

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Instruction Manual Model A

Interscan Corporation. Instruction Manual Series Compact Portable Analyzer

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

Transcription:

Analox 1000 Series User Manual Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net

Contents Package Contents Checklist... 2 About the product... 3 User Controls and I/O Connections... 4 User Controls... 4 I/O Connections... 5 Power supply... 6 Battery Back-up... 7 Alarm Setting and Operation... 7 Calibration... 8 ZERO Adjustment... 8 SPAN Adjustment... 8 Installation... 10 Signal Inputs and Outputs... 11 Sensor connections... 11 Analogue Output... 12 Relay Outputs... 12 Specifications... 13 Analox 1000 Series Range Electrical Specification... 13 Analox 1000 Series Mechanical Specification... 14 Approvals... 15 Disposal... 16 Page 1

Package Contents Checklist I A C H D F E G B A) Analox 1000 O2 Monitor B) 9212-2 Oxygen Sensor C) IEC mains Lead D) 2 Spigot Universal Flow Adaptor E) 2.1mm DC Jack Socket F) 2 Way Screw Terminal Socket Block G) Trimming Tool H) User Manual I) Test Certificate Page 2

About the product The Analox 1000 Series Oxygen (O2) provides continuous digital display of the measured parameter on a 4 ½ Digit red LED display and may be configured to read any value in the range 0000 19999, where a decimal point can be set in position between any two digits to allow the instrument to be configured for the particular version and scale of the instrument. The following range of 1000 Series versions are available: 0.00-00.00% O2 0 2000 mbar pp O2 The Analox 1000 series is easy to use and no additional training is required to operate all versions due to a commonality of user functions. In operation the instrument is easy to calibrate, using just a ZERO and CAL adjustments on the front panel of the instrument. The Analox 1000 range has two user adjustable audio/visual alarms, configurable as HI/HI or HI/LO going (Factory set). Alarms are fitted as standard and these may be adjusted over the full range of the instrument. The audible alarm can then be silenced by pressing the MUTE button. The 1000 Series 100% O2 version also has a HI/LO resolution switch allowing the accuracy of the display to be switched between one and two decimal places (i.e. 100.0% O2 and 100.00% O2). Page 3

User Controls and I/O Connections User Controls Figure 1 below shows the user controls for the 1000 Series instrument on the front panel: 4 ½ Digit LCD SPAN calibration adjust MUTE button Power status HI alarm LED HI Alarm adjust Horn LED LO alarm LED LO Alarm adjust ON/OFF switch SET HI/SET LO alarm switch HI/LO RES switch (Only fitted to 100.00% O2 instrument) ZERO calibration adjust Figure 1 Page 4

I/O Connections Figure 2 below shows the I/O connection for the 1000 Series instrument on the rear panel: AC power fuse IEC socket I/O Terminal block connectors DC Input Figure 2 Page 5

Power supply Power for the instrument may be derived from 1 of 2 options: NOTE: THIS EQUIPMENT MUST BE EARTHED 1 AC power in the range 85 to 264VAC, 47 to 63 Hz and connected via a standard IEC 3 pin plug/socket in the instrument rear panel (see figure 2). A suitable lead is supplied with the instrument. A plug clip is used to hold the IEC connector in place. Note that NO voltage selection is required when using this input the instrument will operate from any voltage within the stated range. The fuse for this AC power input is mounted in the instrument rear panel (see figure 2) and is rated at 1 Amp T type. Plug clip 2 Low voltage DC in the range 12 to 32 VDC with a ripple not exceeding 1 volt and connected via the battery charger type connector or the 2 way screw terminal type connector in the instrument rear panel (see figure 2). THE LOW VOLTAGE DC SUPPLY SHOULD BE EXTERNALLY FUSED at a rating of 1 Amp using a T type delay fuse. Note the correct polarity when using the DC input. Battery charger type connector Screw terminal type connector Page 6

Battery Back-up An optional Battery Back-up option is available (factory fitted) that will power the instrument for approximately 1 hour in the event that the external power supply to the instrument fails. The instrument will automatically change over to the internal battery supply when the external power fails, no user intervention is required. When the instrument is being driven by its internal battery the green STANDBY LED on the front panel (see Figure 1) will be lit and will remain on until external power is restored. When the battery has been discharged to such a level that instrument operation below this level would not be reliable, then a trip circuit will turn off the complete instrument and indicate this state by flashing the green STANDBY LED at approximately 1 second intervals. Alarm Setting and Operation Before any adjustments are made to the HI/LO Alarm adjust controls, the operator should release the locks on the knobs. This is done by moving the small lever located at the edge of the control until the knob turns freely. After adjustment, the locks should be reset in order to prevent accidental movement. The SET HI / SET LO toggle switch (see Figure 1) is normally biased to its central position to read the measured oxygen level. The high alarm trip point is set by moving this switch upward and adjusting the HI Alarm adjust control knob until the desired high alarm trip level is displayed. The low alarm trip point is set by moving the switch downward and adjusting the LO Alarm adjust control knob until the desired level is displayed. The alarm trip levels are adjustable over the full-scale range of the instrument. If the operator only requires to check the current alarm set-points this may be done by just pressing the SET HI / SET LO toggle switch to the appropriate position and the alarm set-point will be shown on the LED display. NOTE: The mechanical locking action may move the set point very slightly and will result in the set point being moved slightly lower than the desired value. If necessary, this can be overcome by observing the error when locking the control and then resetting the adjustment to the desired point PLUS the error before locking. E.g. If the desired setpoint is 23.00 and the observed error on locking is 0.03 then adjust the control to read 23.03 and on locking, the setpoint will be moved to 23.00. If an alarm condition occurs, the internal audible buzzer will sound intermittently and the yellow HORN LED (see Figure 1) will flash, thereby identifying which instrument is causing the alarm. The appropriate red HI or LO LED (see Figure 1) will indicate the alarm level. The audible alarm can then be silenced by pressing the MUTE button (see Figure 1); this action will also turn off the yellow HORN LED. If the reading is still in an alarm condition, the red HI or LO LED will continue to flash until the parameter being measured returns to a non-alarm value. The red LED will then turn off. If an alarm condition occurs and the parameter being measured then returns to normal before the MUTE button is pressed, then the audible and visual alarms will continue to be active until the MUTE button is pressed. This facility allows the operator to be aware of any alarm occurrence whilst the instrument was unattended. The alarms have a built-in hysteresis (The amount of this varies according to the full-scale of the instrument) to overcome nuisance triggering when measuring near the set points. This means that if a high alarm occurs with a set point of 23%, then having been acknowledged by pressing the MUTE button, the alarm will not clear until the oxygen level drops below 22.96%. Page 7

Calibration To calibrate the Analox 1000 instrument the supplied calibration adaptor should be used with 6mmOD x 4mmID Flexible Polyurethane tubing to pass the calibration gas over the Oxygen sensor. The flow adaptor should be connected to the sensor as shown below: Gas out Gas in ZERO Adjustment The instrument sensor should be exposed to the appropriate ZERO gas as shown in the table below: Instrument version Measurement Parameter Range Zero gas Zero Display Adjust 1000 Oxygen 0.00-100.00% Nitrogen 0.00 Oxygen 0-2000mBar pp Nitrogen 0 NOTE: During the zero calibration procedure the LO alarm may trip depending on the alarm set-point level. The gas should be passed across at a flow rate of approximately 0.5 litre/min for a minimum of 3 minutes. When the reading is steady, adjust the ZERO calibration adjust (see Figure 1) control on the instrument front panel until the display reads the required value. SPAN Adjustment The instrument sensor should be exposed to the appropriate SPAN gas as shown in the table below: Instrument version Measurement Parameter Range Span Span Display Adjust 1000 Oxygen 0.00-100.00% A known concentration of Concentration Oxygen* value of gas Oxygen 0-2000mBar A known concentration of Oxygen* Concentration value of gas * Expose the sensor to normal ambient atmosphere (i.e. typically 20.90% or 209 mbar pp) or use a known accurate oxygen concentration gas supply NOTE: During the Span calibration procedure the HI alarm may trip depending on the alarm set-point level. Page 8

The gas should be passed across at a flow rate of approximately 0.5 litre/min for a minimum of 3 minutes. When the reading is steady, adjust the CAL calibration adjust (see Figure 1) control on the instrument front panel until the display reads the required value. Page 9

Installation The Analox 1000 Series range are available in two forms: 1 Suitable for insertion in a 19 inch Rack Frame, occupying ¼ of a standard 3U Frame 2 Suitable for direct mounting in an existing instrument panel For details of dimensions, cut-outs and mounting centres, refer to the Specifications on Page 14 of this handbook. The frame mounting version should be inserted in a suitable rack and secured by the 4 corner screws and bushes supplied with the instrument. When fitting the panel mounted version, the bushes should be left attached to the instrument, as supplied and the whole assembly inserted into the panel, easing the bushes into the 10mm holes. Tightening the 4 screws will expand the bushes, locking them into the panel. If the instrument is subsequently removed from the panel, it is only necessary to remove the screws the bushes should remain captive in the panel. Page 10

Signal Inputs and Outputs All signal inputs and outputs are made to removable, screw terminal plugs. The main connector is located down the right side of the rear panel, when viewed form the rear (see figure 2). The function of each terminal connection is indicated by the table, a copy shown below, on the rear panel (see figure 2). Sensor connections The Analox 1000 Series is designed to accept a Voltage input signal from the O2 sensor. Therefore, the sensor must be connected to the appropriate input terminals to ensure correct operation. The table below list the correct terminal connections for the range of sensors available within the Analox 1000 Series range: Instrument version Wire Function Terminal connection 1000 RED Sensor Signal 11 BLACK Sensor Gnd 10 The instrument MUST have terminals 15 and 16 linked together. Page 11

Analogue Output The Analox 1000 Series range provides 2 analogue output signals that are proportional to the displayed value of the instruments full scale: Analogue Output Terminal Function Terminal Connection 4-20mA Analogue Output Common 7 Analogue Output 4-20mA 9 0-1V Analogue Output Common 7 Analogue Output Volts 8 The current output is powered from an internal nominal 24 volt supply and can operate into a load from 50 Ohms to 500 Ohms. The voltage output should NOT be connected to a load less than 10,000 Ohms. Relay Outputs All instruments in the ANALOX 1000 range are fitted with two single pole change-over relays which operate in conjunction with the HI and LO alarms. The relays contact specification is as follows: Contact Arrangement : 1 Form A, 1 Form C Contact Rating : 10A 120V ac/24v dc (C) 15A 120V ac/24v dc (A) Relay contact Terminal connection LO Alarm Normally Closed (N.C.) 1 LO Alarm Common (COM) 2 LO Alarm Normally Closed (N.O.) 3 HI Alarm Normally Closed (N.O.) 4 HI Alarm Common (COM) 5 HI Alarm Normally Closed (N.C.) 6 The relays may be configured to be energised or de-energised when the instrument is in a non-alarm state. If the relays are configured to be in a normally energised state, this will provide a Fail-Safe facility in that a total power failure will cause the relays to release and signal an alarm condition. However, the extra power drawn by the relays being energised for most of the time will reduce the time for which the instrument will operate on Battery Back-up. Contact arrangement is shown on the rear panel. Instruments normally leave the factory with the relays configured to ENERGISE IN ALARM conditions. Page 12

Specifications Analox 1000 Series Range Electrical Specification Power Supply Options: Display: Analogue Outputs: Alarms: Alarm Relay Outputs: Optional Extras Internal Battery Back-up Range: Accuracy: 85 to 264 VAC 47 to 63 Hz Without switching MAX POWER: 264V 20Watts 85V 15Watts 12v to 32v DC Max Ripple 1v MAX POWER: 6 Watts 4 ½ Digit red LED 0 1 Volt over FS range 4 20 ma over FS range 2 audio/visual alarms, configurable as HI/HI or HI/LO Alarms fully adjustable over FS range of instrument 2 x Single Pole changeover 1 Form A, 1 Form C 10A 120V ac/24v dc (C) 15A 120V ac/24v dc (A) Configurable to be energised or De-energised when in Non-Alarm Condition 5 Volt 1.4 AH Nickel Cadmium Backup time Approx 1 Hour minimum 0.00% - 100.00% at Atmospheric Pressure or 0mBar pp - 2000mBar pp Analox 9212-2 cell 0-100%: The greater of ±1% of reading or ±0.035%O2 at constant temperature and Pressure (CPT) C3 cell 0-100%: ±1% of FS at CTP B1 cell 0-25%: ±1% of FS at CTP 0-100%: ±5.5% of FS at CTP Paramagnetic Sensor 0-100%: ±0.1% of FS at CTP All accuracies assume regular calibration (e.g. at start of each 8 hour operating period). Temperature Effect: +/- 0.1% of Readout per C Page 13

Analox 1000 Series Mechanical Specification Dimensions: Rack Mounted Version Depth: Height: Width: Weight: Overall 245mm Overall 129mm Overall 107mm 2 Kgs Panel Mounted Version Depth: Height: Width: Weight: Overall 245mm Overall 133mm Overall 120mm 2 Kgs Panel cut-out Aperture Height: Width: 112mm 102mm Mounting Centres Holes: Height: Width: Centred: 4 x 10mm 122.5mm 91.4mm on cut-out Environmental Operating Temp: 0-60oC Storage Temp: 40 to +85oC Relative Humidity: 95% at 40oC Non. Condensing Page 14

Approvals Conforms to all applicable requirements of: EN 61000-6-3:2007 EN 50270:2006 EN 61010-1: 2001 This product complies with the requirements of the Electromagnetic Compatibility (EMC) Directive 2004/108/EC This product complies with the requirements of the Low Voltage Directive (LVD) - Directive 2006/95/EC Page 15

Disposal According to WEEE regulation this electronic product can not be placed in household waste bins. Please check local regulations for information on the disposal of electronic products in your area. Page 16