Table of Contents PART I: The History and Current Status of the Industrial HMI PART II: Fundamentals of HMI Design and Best Practices

Similar documents
PERFORMANCE HUMAN NEXT-GENERATION SCADA HIGH. MACHINE INTERFACES Configuring HMIs to Display Operator-centric Information

Effective Alarm Management for Dynamic and Vessel Control Systems

Alarm Management. Version Prepared by: Michael Davis- Hannibal. Softcon Software Control Services (Pty) Ltd.

Where Technology Shapes Solutions. Alarm management : Wasn t that problem already solved years ago?

2012 Honeywell Pacific Users Group. Sus tain.ability.

Critical Condition Management on a Corporate Scale. Lyondell Is a Major Global Chemical Company

Pushing Process Limits Without Compromising Safety

ABB Ability System 800xA Alarm Management

02 21st Century Trends Resources 8/24/2017. Trends in Human Machine Interface (HMI) Old School Trends. The Future of HMI

Alarm Management Standards Are You Taking Them Seriously?

The Top 10 Worst Performing Alarm Systems in Industry

The Abnormal Situation Management Consortium: Past and Future of Abnormal Situation Management

Figure 1. Typical console operator work loading. Figure 2. Line of communication and collaboration between console operators.

Q&A Session from Alarm Management Workflow Webinar (Apr.24/2013)

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

excellence in Dependable Automation The Alarm Shelving ebook

Functional Versus Schematic Overview Displays: Impact on Operator Situation Awareness in Process Monitoring

Current Trends in SCADA Systems. Situational Awareness Alarm Management Data Availability System Robustness/Redundancy

SCADA 101 Introduction to SCADA Systems - Sensors, Data and Screens

DIRECTIVE NO: D-B

Alarm Management for SCADA control rooms

Practical Distributed Control Systems (DCS) for Engineers & Technicians. Contents

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

Page 1 of Relevant Provincial Jurisdictional legislation.

Embracing Change: High Performance Graphics to Improve Operations Water/Wastewater Case Study

DON T JUST REPORT ON ALARMS, TAKE

Facility Commander Complete, Integrated Command and Control

Alarm Management Optimization (AMO) at Saudi Aramco

Lata Mishra Bhabha Atomic Research Centre, INDIA

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

Lecturer: Jim Clauston. Course: QAS 515 Human Factors Engineering in Quality. Term Paper Title: Alarm Management on an Oil & Gas Offshore Platform

IEC61511 Standard Overview

Architectural and Engineering Specification for a Security Management System. StarNet 2

SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA

IE Code IE Competency Title Credit OAC Ref.

Alarm Management for Pipelines

DeltaV Live. Introduction. Benefits. Modern, built-for-purpose operations experience

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION DEDICATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK

Economic and Effective Alarm Management

I&C Upgradation and Modernization at CHASNUPP 1 & 2. Presented By: Waseem Uddin Farooqi PAEC, Pakistan

Prereq: FOD 131 or Instructor Permission

Why AC800M High Integrity is used in Burner Management System Applications?

Human Performance Models for Response to Alarm Notifications in the Process Industries: An Industrial Case Study

HMI of the Future with Experion Orion Console and Experion Collaboration Station Andrew Stuart & Annemarie Diepenbroek, Honeywell

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

WW HMI SCADA-04 Discover the new Situational Awareness Library in InTouch 2014

Exaquantum/ARA Alarm Reporting and Analysis

DELOMATIC 400, DM-400 HYDRO

Kevin Brown and Chris Stearns

Stavros Chrysanthou Madrid DynAMo Alarm Management Secrets to unlocking complete Operational Integrity

Because Safety is not found in a Box

Chapter 18. visual merchandising and display. Section 18.1 Display Features. Section 18.2 Artistic Design

Alarm System Performance Metrics

Ridley Terminals Canada. Site HMI Station. In Central Office. Prepared by: Wayne Leung Controls Specialist. QCA Systems Limited

ANALYSIS OF HUMAN FACTORS FOR PROCESS SAFETY: APPLICATION OF LOPA-HF TO A FIRED FURNACE. Paul Baybutt Primatech Inc. and

Diagnostics with fieldbus

Explosion Protection Engineering Principles

BRIDGING THE SAFE AUTOMATION GAP PART 1

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Electronic Emergency Telegraph. TG-1 and TG-1A

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

I/A Series A 2 Software FoxAlert Alarm Manager

DynAMo Alarm & Operations Management

RESOLUTION MSC.86(70) (adopted on 8 December 1998) ADOPTION OF NEW AND AMENDED PERFORMANCE STANDARDS FOR NAVIGATIONAL EQUIPMENT

Alarm Management & Graphics Projects. Ian Nimmo User Centered Design Services LLC

Combi Steamer Read this manual before using. Convotherm 4 easytouch. Operating Instructions USA Original, ENG. Your meal. Our mission.

Imtech Marine Free Technics. Type-approved, user-centered yacht automation

Next Generation Alarm Management With DynAMo Alarm and Operations Management

Product introduction Layers of Protection Layer 3: Safety System Instrumented & Mechanical. Layer 2: Alarms Manual action needed

Intelligent alarm management

Presenter Joe Pittman

Alfa Laval Touch Control

Improved Dryer Control

1. EXPLORE A CAREER PLAN IN DESIGN AND MERCHANDISING

2012 Honeywell Users Group EMEA Tyron Vardy A Guide to Effective Alarm Management

DYNAMO ALARM MANAGEMENT

Increase your awareness with

Intro. of particular standards for IEC : rd edition 14 MARCH 2017

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems

Planning Checklist for new IGSS projects

Dryer Master Inc. Dryer Master AM 3. Product Manual

Ovation Alarm Management System

Dryer Master DM510 Users Guide

Fire Alarm System Fundamentals

GO BEYOND OTDR LEAVE NO FAULTY NETWORK BEHIND. intelligent Optical Link Mapper

Landscape Architecture - LAND

Alarm Management Reflections

ONYXWORKS AND FIRSTVISION. Version 4

Introduction. Introduction

PoS(ICHEP2012)516. The status of the CMS pixel upgrade detector

EXPORTING ALARM SETPOINTS IN SIEMENS PCS7

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

ERGONOMICS STANDARDS AND TEXTS 2

CT398 Heaterstat TM Temperature Controller. Technical User Guide

Information and Project Plan Proposal for Home Depot Renovation Library

Fundamentals of HVAC/R 2010

Incident Symbology Framework, Guideline, and Operational Implementation Guidance Version 2.0

Transcription:

Table of Contents PART I: The History and Current Status of the Industrial HMI We begin with the origin and evolution of the industrial HMI. The positive and negative issues posed by the introduction of the Distributed Control System (DCS) are covered. The current status of industrial HMIs is characterized, along with clear justification for significant improvement. PART II: Fundamentals of HMI Design and Best Practices The concepts and practices of proper HMI design are examined in detail. Good and bad practices are illustrated. Assessment methods for existing systems are provided. Methods for providing proper process overview, graphic hierarchy, and progressive exposure of detail are introduced, along with detailed design principles and examples. Proper physical console layout and other factors are covered in detail. PART III: Design and Implementation of a High Performance HMI A straightforward methodology is provided for the development, implementation, and maintenance of a High Performance HMI. The methodology is useful for either new applications or for the improvement of existing HMIs. PART IV: Control Rooms, Abnormal Situation Management, and the Future of the Industrial HMI The effect of the control room environment on operator effectiveness is detailed. Proper and improper practices and design considerations are covered. The principles of proper Abnormal Situation Management and human performance are explained. The future direction and capabilities of the industrial HMI are predicted.

Detailed Table of Contents Foreword xxi PART I: The History and Current Status of the Industrial HMI Chapter 1: Introduction 1.1 Why This Book Was Written 1.2 Is This Book for You? 1.3 A Word of Warning! Chapter 2: The State of Industrial HMIs and Operator Graphics 2.1 In the Beginning the Control Panel 2.2 The Arrival of the Distributed Control System 2.3 Early and Current HMIs 2.4 HMI-Related Problems Arise 2.5 How Did This Happen? 2.6 The Answer to the Problem 2.7 Conclusion Chapter 3: The Justification for HMI Change Chapter 4: HMI Best Practices A Managerial Overview 4.1 Bring Back the Big Picture 4.2 Create Hierarchical, Scenario-Based Displays to Improve Situation Awareness and Response 4.3 Redesign Displays to Emphasize the Most Important Information 4.4 Employ Proper Control Room and Physical Console Design 4.5 Minimize Distractions in the Control Room 4.6 Seven Steps for Creating a High Performance HMI 3 5 6 6 9 9 10 12 13 14 17 18 19 29 29 30 31 32 33 33 PART II: Fundamentals of HMI Design and Best Practices Chapter 5: Assessing HMI Performance 5.1 HMI Evaluation Methodology 5.2 A Failing Grade: F 5.3 Not Quite Failing a D 5.4 Still Not Good Enough a C 5.5 Finally a B 37 38 38 39 39 40

5.6 All Right! An A 5.7 Periodic Reassessment Chapter 6: The Development of a High Performance HMI Philosophy and Style Guide 6.1 A First Principle: Users of HMIs 6.2 The HMI Philosophy Document and Style Guide Overview 6.3 Purpose and Use of a High Performance HMI Philosophy Document 6.4 Development of a High Performance HMI Philosophy Document 6.5 HMI Style Guides 6.6 HMI Objects and Object Libraries Chapter 7: Basic Principles for High Performance HMIs 7.1 Overview 7.2 The Process Pictorial An Overused, Low-Performance Paradigm 7.3 Recognizing Good and Bad Graphics at a Glance: 7.4 Data is Not Information! 7.5 Analog is Often Better 7.6 Moving Analog Indicators 7.7 Other Analog Depiction 7.8 The Importance of Trends 7.9 Proper Implementation of Trends 7.10 General Considerations for Displays 7.11 Use of Color 7.12 Standards and Color Conflict 7.13 Depicting Lines, Vessels, and Static Equipment 7.14 Depicting Text 7.15 Depicting Values 7.16 Depicting Vessel Levels 7.18 Depicting Alarm Behavior 7.19 Alarm Priorities 7.20 Alarm Indication Methods 7.21 Alarm Access 7.22 Audible Alarm Indication 7.23 Objects and Symbols 7.24 Process Controllers 7.25 Control Valves and Shutoff Valves 7.26 Instrument Lines 7.27 Depicting Dynamic Equipment 7.28 Depicting Equipment Commands 41 41 43 43 44 45 45 45 46 47 47 49 50 53 56 60 61 62 64 67 67 70 70 73 74 75 76 76 77 80 81 85 85 88 90 90 91

7.29 Display Layout 7.30 Navigation 7.31 Yoking 7.32 Shutdown Actuation 7.33 Call-up Speed and Performance Expectations 7.34 Depicting Material Balance Chapter 8: Detailed Design of High Performance Displays 8.1 Display Hierarchy 8.2 Designing Level 1 Process Overview Displays 8.3 Designing Level 2 Process Control Displays 8.4 Startup, Shutdown, and Abnormal Situation Level 2 Displays 8.5 Displaying Interlock Functionality on Level 2 and Level 3 Displays 8.6 Designing Level 3 Process Detail Displays 8.7 Designing Level 4 Process Support and Diagnostic Displays 91 92 92 92 93 94 97 97 98 102 104 109 113 114 PART III: Design and Implementation of a High Performance HMI Chapter 9: The Design and Implementation of High Performance HMI Displays 9.1 Overview 9.2 Determine Specific Performance and Goal Objectives for the Control of the Process, in All Modes of Operation 9.3 Perform Task Analysis to Determine Control Manipulations Needed to Achieve the Performance and Goal Objectives 9.4 Design High Performance Graphics, Using the Design Principles in the HMI Philosophy and Elements From the Style Guide, to Address the Identified Tasks. 9.5 Install, Commission, and Provide Training on the New Displays 9.6 Control, Maintain, and Periodically Reassess the HMI Performance Chapter 10: Physical Screens and Layout of an Operator Console 10.1 Physical Screens 10.2 General Purpose PC 119 119 120 121 124 125 125 127 127 128 128

10.3 Communications Gear 10.4 Multiple Keyboards 10.5 External Video 10.6 Hardwired Switches 10.7 Incorporation of Lightboxes 10.8 Vertically Stacked Displays 10.9 Alternative High Performance Console Layouts 10.9.1 High Performance Console #1: 6 Total Screens in a Horizontal Arrangement 10.9.2 High Performance Console #2: 6 Total Screens in a Semi-Horizontal Arrangement 10.9.3 High Performance Console #3: 6 Total Screens in a 2-Tier arrangement 10.9.4 High Performance Console #4: 8 Total Screens in a Vertically Staggered Arrangement 129 129 129 130 132 133 134 135 135 136 PART IV: Control Rooms, Abnormal Situation Management, and the Future of the Industrial HMI Chapter 11: Control Room Design, Layout, Operating, and Management Practices 11.1 Overview 11.2 Early Control Rooms 11.3 The Introduction of Human Factors Design 11.4 Design of New Control Rooms 11.5 Lighting Levels 11.6 Glare and Reflection 11.7 Acoustics 11.8 Music 11.9 Telephones 11.10 Other Distractions 11.11 Workload Analysis 11.12 Console Adjacency and Arrangement 11.13 Video Walls Chapter 12: Situation Awareness and Abnormal Situation Response 12.1 Stress and Performance 12.2 Performance Shaping Factors 12.3 Abnormal Situation Management Concepts 12.4 Human Problem-Solving Behavior 12.5 Human Errors 12.6 The Distribution of Failure 141 141 142 143 145 147 149 150 150 151 151 152 154 157 159 159 161 162 163 164 165

12.7 The HMI as the Solution Chapter 13: The Future of the Industrial HMI 166 167 Appendices Appendix 1: High Performance HMI Philosophy Document and Style Guides Example Tables of Contents Appendix 2: Assessing HMI Performance A2.1 General Graphic Factors A2.2 Navigation Factors A2.3 Workstation Factors A2.4 Control Room and Work Practice Factors A2.5 Alarm Management Factors A2.6 Operator Questionnaire A2.7 Testing the High Performance HMI vs. the Traditional HMI Appendix 3: The PRO Enhanced Radar Plot a Highly Effective HMI Element Appendix 4: A Brief Overview of Alarm Management References About The Authors 171 175 175 176 177 177 178 178 181 185 189 201 205

Illustrations Figure 2-1: A Typical Pre-DCS Control Panel Figure 2-2: A Typical Pre-Graphic Group Display Figure 2-3: A Typical Vendor Graphic More Appropriate For Selling Systems Than Operating a Process Figure 3-1: Garmin G1000 Dual-Screen Integrated Avionics in a Small Aircraft Figure 3-2: Typical Process Industry Graphic Figure 3-3: Operating By Alarm Figure 3-4: High Performance HMI Benefits Figure 3-5: Commando Cody HMI Figure 4-1: An Over-the-Top Overview Display Figure 7-1: An Example Graphic Violating Many Of The Principles For A High Performance HMI Figure 7-2: Displaying Lots of Data Figure 7-3: Fluffy s Blood Test Figure 7-4 Fluffy s Blood Test View 2 Figure 7-5: Fluffy s Third Blood Test View 3 Figure 7-6: Can You Make the Meeting? Figure 7-7: He s Not Dead, Jim. Figure 7-8: A Process Pictorial View of a Compressor Figure 7-9: A High Performance View of a Compressor Figure 7-10: Moving Analog Indicator Enhancements Figure 7-11 At-A-Glance Indicators Column Temperatures Figure 7-12: Data Needing a Trend Figure 7-13: Trend Showing Slow Increase Figure 7-14: Trend Showing Oscillation Figure 7-15: Trend Showing Prior Upset Figure 7-16: An All-Trend Level 2 Display with Access to the Relevant Process Controllers Figure 7-17: Shades of Gray and Contrast Figure 7-18: 3D vs. 2D Vessels and Lines Figure 7-19: Low-Contrast Blob Graphic Elements Figure 7-20: Values and Faceplate Pop-ups Figure 7-21: Example Practices for Vessel Levels Figure 7-22: Method 1 Solid Color Blocks Behind the Process Value (Not Recommended) Figure 7-23: Method 2 Color Outlines Around the Process Value (Not Recommended) Figure 7-24: Method 3 (Recommended) The Separate Alarm Indicator Element Figure 7-25: Alarm Suppression Indicator Figure 7-26: Method 4 The Separate Alarm Indicator Element with 10 11 15 21 23 25 27 28 30 51 54 54 55 55 56 58 59 59 60 61 62 62 63 63 66 69 72 72 75 76 77 78 78 79 79

Figure 7-27: Figure 7-28: Figure 7-29: Figure 7-30: Figure 7-:31 Figure 7-32: Figure 7-33: Figure 7-34: Figure 7-35: Figure 8-1: Figure 8-2: Figure 8-3: Figure 8-4: Figure 8-5: Figure 8-6: Figure 8-7: Alarm Type (Not Recommended) A Typical DCS Controller With More Than 80 Parameters A Simplified Controller Element for Graphics Progressive Exposure of Controller Detailed Functionality Simple Valve Depiction One Controller With Multiple Valves Pump Run Status Depiction Layers of Confirmation Mass Balance Indicators The ISOM Unit Graphic. This Image is From the CSB s Final Report on the 2005 BP Texas City Explosion and Fire. High Performance HMI Display Hierarchy Logical Arrangement of a Process Overview Display Example Contents of a Process Overview Display A Non-Projection Technology Overview Display Example of a Level 2 Display An Example of a High Performance Display Element Used for Startup Another Example Element of a High Performance Display Element Used for Startup Figure 8-8: Interlock Depiction Part 1 Figure 8-9: Interlock Depiction Part 2 Figure 8-10: Interlock Depiction Part 3 Figure 8-11: Figure 8-12: Figure 8-13: Figure 8-14: Figure 9-1: Figure 9-2: Figure 9-3: Figure 10-1: Figure 10-2: Figure 10-3: Figure 10-4: Figure 10-5: Figure 10-6: Interlock Diagnostic Table Shutdown Initiator Table with First Out Schematic Example of a Level 3 Compressor Display Example of Alarm Rationalization Information Example Modes of Operation Example Performance and Goal Objectives for One Mode Observation and Control Elements for a Level 2 Display What Happens If You Do Not Plan Ahead A Typical Lightbox Alternative Presentations Stacked Displays a Non-Ergonomic DCS Screen Arrangement Vertically Staggered Displays an Improvement High Performance Horizontal 6 Screen Console Layout 86 87 88 89 89 90 93 95 95 98 100 101 102 105 106 107 109 110 110 112 112 115 116 121 121 123 128 130 131 132 133 134

Figure 10-7: Figure 10-8: Figure 10-9: Figure 11-1: Figure 11-2: Figure 11-3: Figure 11-4: Figure 11-5: Figure 11-6: Figure 11-7: Figure 12-1: Figure 12-2: Figure 13-1: Figure A2-1: Figure A3-1: Figure A3-2: Figure A3-3: Figure A3-4: Figure A4-1: Figure A4-2: Figure A4-3: Figure A4-4: Figure A4-5. Figure A4-6: High Performance Semi-Horizontal 6 Screen Console Layout High Performance 2-tier 6 Screen Console Layout High Performance 2-tier 8 Screen Console Layout Control Room Design Factors One of Many Ergonomic Design Guidelines Contained in the SINTEF Report Checklist A Refinery Unit Interactions Diagram A Console Adjacency Matrix Console Triangular Arrangement Possible Control Room with Video Wall Possible Control Room with Circular Stations Relationships of Stress and Performance Human Interaction with a Process Control System Garmin G1000 Showing Highway in the Sky and Terrain Mapping Example Normal and Abnormal Scenarios The Concept of a Time-varying Multivariable Display Mapped Into a 2-D Space A PRO Display Element PRO Display Element with Alarms, Range Bars, and Rate-of-Change Indicators PRO Display Element in Deviation Mode Exponential Growth of Configured Alarm Counts Per Operator Rate of Alarms Per Day far Exceed Manageable Levels Resolving the Top 20 Bad Actor Alarms Often Leads to Significant Improvement Best Practice Recommendation for Alarm Priority Determination Alarm Systems Degrade Over Time Without Proper MOC Alarm Floods Render the Alarm System Useless to the Operator 135 136 137 146 147 154 155 156 158 158 160 163 169 181 185 187 187 188 191 193 194 196 197 199