This is a Maintenance Report generated by Cappsure for the property below. Property Name Creator : CFD 2 - Westport : Joseph Beardshear Date : 10/06/2017 1 INSPECTION RESTROOMS-UNSATIS. RESTROOMS CLEAN AND STOCKED 2 SATIS. NO GRAFITTI-UNSATIS. GRAFFITI NEEDS REMOVAL 3 SATIS. NO GRAFITTI-UNSATIS. GRAFFITI NEEDS REMOVAL 4 SATIS. NO GRAFITTI-UNSATIS. GRAFFITI NEEDS REMOVAL 5 UNSATIS. WEEDS IN TURF-UNSATIS. WEEDS IN TURF 6 INSPECTION RESTROOMS-UNSATIS. RESTROOMS CLEAN AND STOCKED 7 UNSATIS. WEEDS IN TURF-UNSATIS. WEEDS IN TURF 8 UNSATIS. WEEDS IN TURF-UNSATIS. WEEDS IN TURF 9 UNSATIS. POOR COVERAGE-UNSATIS. POOR COVERAGE 10 SATIS. NO GRAFITTI-UNSATIS. GRAFFITI NEEDS REMOVAL 11 UNSATIS. POOR COVERAGE-UNSATIS. POOR COVERAGE 12 UNSATIS. IRRIGATION BREAK/LEAK- UNSATIS. IRRIGATION BREAK/LEAK 13 UNSATIS. GOPHER ISSUES-UNSATIS. GOPHER ISSUES 14 UNSATIS. GOPHER ISSUES-UNSATIS. GOPHER ISSUES 15 UNSATIS. BARE AREA-UNSATIS. BARE AREA Toilet paper through outmrestroom floor. Fixture not thoroughly cleaned and applied with stainless steel cleaner. Ongoing graffiti dating back to May inspections. Heavy infestation of Kikuyu grass in parkway. Also broadleaf weeds present. Pipe chase rooms cluttered. could not walk through to access plumbing or irrigation clocks. Large patch of Kikuyu grass. In general large amounts of Poa annua in park fescue. Also broad leaf weeds through out park in turf. This irrigation station is not getting head to head coverage. Needs to be evaluated and adjusted. Graffiti on drinking fountain. Rotor on parkinglot side overshooting onto sidewalk. Either possible broken pop-up or lateral. Active gopher in middle of park. Bare areas in planter need to be filled in with ground cover. 16 UNSATIS. IRRIGATION BREAK/LEAK- Rotor head damaged. Needs to be Page 1
UNSATIS. IRRIGATION BREAK/LEAK 17 INSPECTION TURF-UNSATIFACTORY POOR TURF HEALTH 18 UNSATIS. GOPHER ISSUES-UNSATIS. GOPHER ISSUES 19 UNSATIS. TREES NEED PRUNING- UNSATIS. TREES NEED PRUNING 20 UNSATIS. WEEDS IN TURF-UNSATIS. WEEDS IN TURF 21 UNSATIS WATERING TOO DRY- UNSATIS WATERING TOO DRY 22 UNSATIS. EXERCISE STATIONS NEED ATTN.-UNSATIS. EXERCISE STATIONS NEED ATTN. 23 SATIS. NO GRAFITTI-UNSATIS. MISSING OR DAMAGED ITEMS 24 SATIS. NO GRAFITTI-UNSATIS. MISSING OR DAMAGED ITEMS 25 UNSATIS. GOPHER ISSUES-UNSATIS. GOPHER ISSUES 26 UNSATIS. BARE AREA-UNSATIS. BARE AREA 27 UNSATIS WATERING TOO DRY- UNSATIS WATERING TOO DRY 28 UNSATIS. STRAP REMOVAL NEEDED- UNSATIS. STRAP REMOVAL NEEDED 29 UNSATIS WEEDS IN PLANTERS- UNSATIS WEEDS IN PLANTERS 30 UNSATIS. STRAP REMOVAL NEEDED- UNSATIS. STRAP REMOVAL NEEDED 31 UNSATIS. BARE AREA-UNSATIS. BARE AREA 32 UNSATIS. BARE AREA-UNSATIS. BARE AREA 33 INSPECTION SHRUBBERY-UNSATIS. POOR HEALTH PLANT MATERIAL 34 UNSATIS. STRAP REMOVAL NEEDED- UNSATIS. STRAP REMOVAL NEEDED 35 UNSATIS. IRRIGATION BREAK/LEAK- UNSATIS. IRRIGATION BREAK/LEAK replaced. Trees along nature trail need sucker growth removed, formed and thinned. Ongoing since May inspections. Ground cover dying due to heat stress and lack of water. In general. Exercise stations need painting service. Multiple benches need painting service and repair. Trash can has fire damage. Needs to be replaced. Station not recieving enough water. Killing ground cover. Tree is mature and no longer needs stakes. All three stakes need to be removed. Large weed mistaken for plant. Needs to be removed. Wires and straps from old stake needs to be removed. Will damage tree if not removed. In general through out planter. Begonias that were in bad health have been removed. Three fortunia shrubs in bad health. Need tratment from a herbicide. Remove stakes from tree in planter. Irrigation popup blocked and flooding turf. Head needs to be cleared. Page 2
36 UNSATIS. POOR COVERAGE-UNSATIS. POOR COVERAGE 37 UNSATIS. WEEDS IN TURF-UNSATIS. WEEDS IN TURF 38 UNSATIS. POOR HEALTH/DEAD- UNSATIS. POOR HEALTH/DEAD 39 UNSATIS. FOUNTAIN NOT WORKING- UNSATIS. FOUNTAIN NOT WORKING 40 UNSATIS WEEDS IN PLANTERS- UNSATIS WEEDS IN PLANTERS 41 INSPECTION TURF-UNSATIFACTORY POOR TURF HEALTH 42 UNSATIS WEEDS IN PLANTERS- UNSATIS WEEDS IN PLANTERS 43 UNSATIS. TREES NEED PRUNING- UNSATIS. TREES NEED PRUNING 44 SATIS. NO GRAFITTI-UNSATIS. MISSING OR DAMAGED ITEMS 45 UNSATIS. POOR COVERAGE-UNSATIS. POOR COVERAGE 46 UNSATIS WEEDS IN PLANTERS- UNSATIS WEEDS IN PLANTERS 47 UNSATIS. VINE NEEDS TRIMMING- UNSATIS. VINE NEEDS TRIMMING 48 UNSATIS WEEDS IN PLANTERS- UNSATIS WEEDS IN PLANTERS 49 UNSATIS. EXCESSIVE LEAF LITTER- UNSATIS. EXCESSIVE LEAF LITTER 50 UNSATIS WATERING TOO DRY- UNSATIS WATERING TOO DRY 51 UNSATIS. VINE NEEDS TRIMMING- UNSATIS. VINE NEEDS TRIMMING Nozzle clogged. Broad leaf and kikuyu weed through out green belt. ongoing since May inspections. Two pine trees in poor health. Grass weed through out planter. Suggest spraying with a selective herbicide. Palm fronds on palm need to be lifted. Missing quick coupler lid. Two popups turned off or clogged causing ground cover to stress. Vine way overgrown. Needs to be trimmed tight to wall and 6" from the top of the wall. Two cactus and failing flax to be removed. Grass clippings need to be cleaned up. Entire median showing signs of drought stress. Vine needs to be trimmed tight to wall. Page 3
Page 4
Picture: 2 Page 5
Picture: 3 Page 6
Picture: 4 1 INSPECTION RESTROOMS-UNSATIS. RESTROOMS CLEAN AND STOCKED Toilet paper through outmrestroom floor. Fixture not thoroughly cleaned and applied with stainless steel cleaner. Page 7
Page 8
Picture: 2 Page 9
Picture: 3 Page 10
Picture: 4 2 SATIS. NO GRAFITTI-UNSATIS. GRAFFITI NEEDS REMOVAL Ongoing graffiti dating back to May inspections. Page 11
3 SATIS. NO GRAFITTI-UNSATIS. GRAFFITI NEEDS REMOVAL Page 12
4 SATIS. NO GRAFITTI-UNSATIS. GRAFFITI NEEDS REMOVAL Page 13
5 UNSATIS. WEEDS IN TURF-UNSATIS. WEEDS IN TURF Heavy infestation of Kikuyu grass in parkway. Also broadleaf weeds present. Page 14
6 INSPECTION RESTROOMS-UNSATIS. RESTROOMS CLEAN AND STOCKED Pipe chase rooms cluttered. could not walk through to access plumbing or irrigation clocks. Page 15
7 UNSATIS. WEEDS IN TURF-UNSATIS. WEEDS IN TURF Large patch of Kikuyu grass. Page 16
8 UNSATIS. WEEDS IN TURF-UNSATIS. WEEDS IN TURF In general large amounts of Poa annua in park fescue. Also broad leaf weeds through out park in turf. Page 17
9 UNSATIS. POOR COVERAGE-UNSATIS. POOR COVERAGE This irrigation station is not getting head to head coverage. Needs to be evaluated and adjusted. Page 18
Page 19
Picture: 2 14 UNSATIS. GOPHER ISSUES-UNSATIS. GOPHER ISSUES Active gopher in middle of park. Page 20
Page 21
Picture: 2 15 UNSATIS. BARE AREA-UNSATIS. BARE AREA Bare areas in planter need to be filled in with ground cover. Page 22
16 UNSATIS. IRRIGATION BREAK/LEAK- UNSATIS. IRRIGATION BREAK/LEAK Rotor head damaged. Needs to be replaced. Page 23
17 INSPECTION TURF-UNSATIFACTORY POOR TURF HEALTH Page 24
18 UNSATIS. GOPHER ISSUES-UNSATIS. GOPHER ISSUES Page 25
19 UNSATIS. TREES NEED PRUNING- UNSATIS. TREES NEED PRUNING Trees along nature trail need sucker growth removed, formed and thinned. Page 26
21 UNSATIS WATERING TOO DRY- UNSATIS WATERING TOO DRY Ground cover dying due to heat stress and lack of water. Page 27
22 UNSATIS. EXERCISE STATIONS NEED ATTN.-UNSATIS. EXERCISE STATIONS NEED ATTN. In general. Exercise stations need painting service. Page 28
Page 29
Picture: 2 Page 30
Picture: 3 Page 31
Picture: 4 23 SATIS. NO GRAFITTI-UNSATIS. MISSING OR DAMAGED ITEMS Multiple benches need painting service and repair. Page 32
24 SATIS. NO GRAFITTI-UNSATIS. MISSING OR DAMAGED ITEMS Trash can has fire damage. Needs to be replaced. Page 33
26 UNSATIS. BARE AREA-UNSATIS. BARE AREA Page 34
27 UNSATIS WATERING TOO DRY- UNSATIS WATERING TOO DRY Station not recieving enough water. Killing ground cover. Page 35
28 UNSATIS. STRAP REMOVAL NEEDED- UNSATIS. STRAP REMOVAL NEEDED Tree is mature and no longer needs stakes. All three stakes need to be removed. Page 36
29 UNSATIS WEEDS IN PLANTERS- UNSATIS WEEDS IN PLANTERS Large weed mistaken for plant. Needs to be removed. Page 37
30 UNSATIS. STRAP REMOVAL NEEDED- UNSATIS. STRAP REMOVAL NEEDED Wires and straps from old stake needs to be removed. Will damage tree if not removed. Page 38
31 UNSATIS. BARE AREA-UNSATIS. BARE AREA In general through out planter. Page 39
32 UNSATIS. BARE AREA-UNSATIS. BARE AREA Begonias that were in bad health have been removed. Page 40
33 INSPECTION SHRUBBERY-UNSATIS. POOR HEALTH PLANT MATERIAL Three fortunia shrubs in bad health. Need tratment from a herbicide. Page 41
34 UNSATIS. STRAP REMOVAL NEEDED- UNSATIS. STRAP REMOVAL NEEDED Remove stakes from tree in planter. Page 42
35 UNSATIS. IRRIGATION BREAK/LEAK- UNSATIS. IRRIGATION BREAK/LEAK Irrigation popup blocked and flooding turf. Head needs to be cleared. Page 43
36 UNSATIS. POOR COVERAGE-UNSATIS. POOR COVERAGE Nozzle clogged. Page 44
37 UNSATIS. WEEDS IN TURF-UNSATIS. WEEDS IN TURF Broad leaf and kikuyu weed through out green belt. ongoing since May inspections. Page 45
38 UNSATIS. POOR HEALTH/DEAD- UNSATIS. POOR HEALTH/DEAD Two pine trees in poor health. Page 46
40 UNSATIS WEEDS IN PLANTERS- UNSATIS WEEDS IN PLANTERS Page 47
41 INSPECTION TURF-UNSATIFACTORY POOR TURF HEALTH Page 48
42 UNSATIS WEEDS IN PLANTERS- UNSATIS WEEDS IN PLANTERS Grass weed through out planter. Suggest spraying with a selective herbicide. Page 49
43 UNSATIS. TREES NEED PRUNING- UNSATIS. TREES NEED PRUNING Palm fronds on palm need to be lifted. Page 50
45 UNSATIS. POOR COVERAGE-UNSATIS. POOR COVERAGE Two popups turned off or clogged causing ground cover to stress. Page 51
46 UNSATIS WEEDS IN PLANTERS- UNSATIS WEEDS IN PLANTERS Page 52
47 UNSATIS. VINE NEEDS TRIMMING- UNSATIS. VINE NEEDS TRIMMING Vine way overgrown. Needs to be trimmed tight to wall and 6" from the top of the wall. Page 53
48 UNSATIS WEEDS IN PLANTERS- UNSATIS WEEDS IN PLANTERS Two cactus and failing flax to be removed. Page 54
49 UNSATIS. EXCESSIVE LEAF LITTER- UNSATIS. EXCESSIVE LEAF LITTER Grass clippings need to be cleaned up. Page 55
Page 56
Picture: 2 50 UNSATIS WATERING TOO DRY- UNSATIS WATERING TOO DRY Entire median showing signs of drought stress. Page 57