Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

Similar documents
UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Sprinkler Permit Applications

Environmental Health & Safety

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Fire Sprinkler System Design and Installation Requirements

DIVISION 21 - FIRE SUPPRESSION

PLAN REVIEW CHECKLIST

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

AUTOMATIC FIRE SPRINKLER SYSTEMS

CITY OF PASADENA FIRE DEPARTMENT

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

DIVISION 21 - FIRE SUPPRESSION

SECTION SPRINKLER SYSTEMS

FIRE SPRINKLER SYSTEMS POLICY

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

SECTION WET-PIPE SPRINKLER SYSTEMS

FIRE SPRINKLER SYSTEMS POLICY

2. Welding Materials and Procedures shall conform to the ASME Code.

MONTECITO FIRE PROTECTION DISTRICT

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

APPENDIX H (DESIGN SUBMISSION CRITERIA)

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

Contren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

NFPA Edition Update

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

SECTION : FIRE PROTECTION SYSTEMS

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

FIRE SUPPRESSION SPRINKLER SYSTEM

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

A. This section includes design and performance information for fire protection and suppression systems.

SECTION WET-PIPE FIRE SUPPRESSION SPRINKLERS

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

ADDENDUM NO. 3 March 19, 2018

Sprinkler Standards Proposed Technical Changes

New Construction Fire Inspection Process

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

Gas Station & C Store SECTION CWM Job No

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

SECTION WET-PIPE SPRINKLER SYSTEMS

Deluge/Preaction Systems Annotated Instructor s Guide

Deluge/Preaction Systems Annotated Instructor s Guide

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

Port of St Helens SIA Aircraft Hanger Scappoose, OR

SECTION DRY-PIPE SPRINKLER SYSTEMS

SECTION DRY-PIPE SPRINKLER SYSTEMS

Design & Construction Standards, Revised January

DESIGN & CONSTRUCTION GUIDELINES

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

Fire Prevention Coffee Break Training. May 2017

DIVISION 21 FIRE SUPPRESSION

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

ADDENDUM #1 ITB# Fire Protection Maintenance Services Responses to Clarification Questions 10/06/2015

PLAN REVIEW SUBMITTAL GUIDE

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Fire District Dwelling Construction Requirements

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

City of Vista Fire Department

SECTION SPRINKLER SYSTEMS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Fire Sprinkler Plan Submittal Form

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6

Sprinkler System Installer Level 2

MSC Guidelines for Automatic Sprinkler Systems

Plan Review Check List Fire Alarm System

Fire Sprinkler Submittal Requirements and Acceptance Testing

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

SECTION FIRE-SUPPRESSION STANDPIPES

TECHNICAL DATA MODEL V-HIP SPECIFIC APPLICATION ATTIC SPRINKLER VK660

SPRINKLER PROTECTION OF COMBUSTIBLE CONCEALLED SPACES WITH LESS THAN 6 BETWEEN OPPOSITE FACES IN CAVITY.

UMC El Paso Far East Clinic and Neighborhood Healthcare Center West Issue for Construction Page Project No and April 13, 2015

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

S000 SITE REVIEW APPR NO. FIRE CODE COMPLIANCE ITEM

TECHNICAL DATA OBSOLETE

SECTION FIRE SUPPRESSION SYSTEMS

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

SECTION ADDENDUM NO. 1 FIRE SPRINKLER SYSTEM

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Transcription:

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 SPRINKLER SHOP DRAWINGS 2007 NFPA 13 and 2007 NFPA 24 Project: Listed items require sprinkler system shop drawing revisions and manufacturer product cut sheets verifying listing by a nationally recognized testing laboratory. Answers in letter form are not acceptable. Starting construction before plans approval may be considered as just cause to issue a stop work order. Correction lists are not all inclusive. Submittal Requirements 1. Provide two (2) full size paper copies of plans, one copy of specifications, and one pdf copy on a CD. The documents submitted are to include the responsible managing employee s signature and number, two copy of hydraulic calculations for each design demand area, and two copy of manufacturer s cut sheets verifying fire protection listings for underground and aboveground piping, fittings, valves, devices, sprinkler heads, hangers, etc. [2009 IBC 107.2.2] 2. The automatic sprinkler system shop drawings must be reviewed and approved by the fire protection engineer of record processed with the engineer s shop drawing review stamp prior to the submittal to the Montgomery County Codes Department. Underground 1. Provide a complete site plan showing the following per NFPA 13 Chapter 10 and NFPA 24 Chapter 10. A. Identify the location and size of the city main at the sprinkler system tap. Show the location of the domestic water tap. Work from the Point of Service must be performed by a registered sprinkler contractor. Show the point at which your contract begins. If

your work is aboveground only, approval will be postponed until the underground shop drawings are submitted and approved. B. Provide details of the underground piping from the city main to the building identifying: line size (6" min., unless the requirements of NFPA 13 23.1.3.2 are met), depth of bury (3 ft. min.), sectional valve locations, valve pit, thrust block size and location, and pipe trench detail. [NFPA 24 Chapters 4 &10 and NFPA 13 Chapter 10] C. Provide a cross section of the valve pit. See NFPA 13 Figure A.8.16.2 (b) D. Identify whether a reduced pressure backflow preventer or meter are present. E. The fire department connection must be on the street side of the building and be located and arranged so that hose can be attached without interference from any objects, fences, posts, buildings, etc. [NFPA 24 5.9.5.2 and NFPA 13 A.8.17.2.1] F. The pumper hydrant must be within 100 feet of the fire department connection. [Office policy] G. Show the location of the fire pump and/or tank and if needed, the backup power source. Additional information must be provided see the attached Fire Pump or Tank Shop Drawing check list. [NFPA 22.1.3] 2. A post indicator valve is required for supply lines. [NFPA 24 6.3.1] The PIV must be electronically supervised and should be located not less than 40 feet from the building. [2009 IBC 903.4 and NFPA 13 8.16.1.1.2] 3. Provide tamper switches at all control valves in the fire service main. [NFPA 13 8.16.1.1.2 and 2009 IBC 903.4] 4. Service mains must not run under building(s) unless special precautions are taken (i.e., arched foundation walls, covered trenching, and isolation valves.) Provide details. [NFPA 24 0.6, and NFPA 13 10.6.2] 5. Provide a leadin detail where the underground piping passes through the foundation and attaches to the riser. Provide clearance to prevent breakage of the piping due to building settlement. [NFPA 13 23.1.6.1, and.2] Provide a method for drainage where the leadin terminates at a point lower than grade. [NFPA 13 8.16.2] AboveGround 1. Label each room of the building (classroom, storage, janitor s closet, etc.). Label all covered porches, balconies, covered walkways, and loading docks. 2. Provide a sprinkler system riser schematic with control and check valves, backflow prevention devices, supply and system pressure gauges, water flow switches, tamper supervising switches, local water flow alarm location, and spare sprinkler head cabinet location. [NFPA 13 6.9.2, NFPA 13 22, Tennessee Board of Architects and Engineering Reference Manual Appendix F Standard of Care.

3. Provide a local waterflow alarm. [NFPA 13 6.9.3] 4. Show that the system is supervised per NFPA 13 8.16.1.1.2 and 2009 IBC 903.4: A. Provide tamper switches at all control valves. B. Provide a flow switch or alarm check valve and specify connection to the general building alarm that sounds within 90 seconds of flow. [NFPA 72 5.11.2 and NFPA 13 6.9.1] For systems protecting storage in accordance with NFPA 13 12.3, provide alarm service per NFPA 13 8.17.1.7. C. For highrise buildings, the requirements of NFPA 13 8.17.1.6 must be met. 5. Supply a spare assortment of sprinkler heads with a wrench. [NFPA 13 6.2.9] 6. The fire department connection must be an approved NH standard, internal threaded swivel fitting, with listed plugs or caps. [NFPA 13 6.8] 7. The maximum area limitation for the provided number of risers is exceeded. The maximum area limitation for the provided number of risers is: Light or ordinary hazard 52,000 sq. ft. per riser and extra hazard 40,000 sq. ft. per riser. [NFPA 13 8.2.1] 8. The entire building must be sprinklered. Identify all areas to be sprinklered. A. Elevator shafts must be sprinklered at the bottom of the shaft. [NFPA 13 8.15.5] B. Provide sprinkler protection under an accessible first landing of a noncombustible stair and at the top of the stair shaft. [NFPA 13 8.15.3.2.1] C. Provide sprinklers under all combustible ground floors, exterior docks, and platforms. See reference for exceptions. [NFPA 13 8.15.6] D. Provide sprinklers under combustible exterior roofs or canopies exceeding 4 ft. in width. See reference for exceptions. [NFPA 13 8.15.7] E. Provide sprinklers in every aisle and tier for library stack rooms. See reference for exceptions. [NFPA 13 8.14.9] F. Provide sprinklers for electrical equipment rooms. See reference for exceptions. [NFPA13 8.15.10] A. Provide sprinkler protection for elevator equipment rooms. [NFPA 13 8.15.5.3] The electrical equipment room exception does not apply elevator equipment rooms. B. Provide sprinklers at stages, under the stage (if combustible construction or used for storage), and at all adjacent stage areas. [NFPA 13 8.15.16.1] Where proscenium opening protection is required provide a deluge system with open heads no more than 3

feet from the stage side of the opening, and at a maximum of 6 feet on center. [NFPA 138.15.16.2] C. Combustible concealed spaces must be sprinklered per NFPA 13 8.15.1. This includes floorceilings made with composite wood joists, except where the ceiling is installed directly to the joist or with channels (maximum 1 ), the joist channels are firestopped into 160 ft3 with materials equivalent to the joist construction, and where channels are used, at least 3 ½ of batt insulation is installed at the joist channel. [NFPA 13 8.15.1.2.6] D. For dwelling units, sprinkler bathrooms, closets, and pantries per NFPA 13 8.15.8. 9. Identify the sprinkler types with a legend. Provide the manufacturer, model, discharge (upright, pendent, sidewall, etc.), response (standard or quick), coverage (standard or extended), orifice size, K factor, and the operating temperature. 10. Standard coverage sprinklers must be located per the charts given on Tables 8.6.2.2.1(a), (b), (c), and (d). 11. Extended coverage sprinklers (upright, and pendent) must be installed per their listing. Provide the listing information and identify the coverage used. The proper K Factor must be used in the hydraulic calculations. 12. The maximum coverage for any head is 400 ft2. [NFPA 13 8.5.2.2.2] 13. The minimum spacing for sprinkler heads is 6 feet unless the requirements of 8.6.3.4.2,.3, or.4 are met. [NFPA 13 8.6.3.4.1] 14. Sprinklers in light hazard occupancies must be one of the four types listed in NFPA 13 8.3.3.1. 15. Sidewall sprinklers may only be installed for light hazard where the ceiling is smooth and horizontal or sloped and flat. Maximum coverage for standard light hazard side wall sprinkler heads is 196 sf. Ordinary hazard occupancies must have smooth, flat ceilings and a head specifically listed for this use. [NFPA 13 8.4.2, Table 8.7.2.2.1] 16. Provide a building cross section with sprinkler heads showing clearances and distances from beams, ducts, structural members, etc. Distances from obstructions must be as specified for the type of sprinkler head in NFPA 13 Chapter 8. 17. Where branch lines run near roof structural members, provide a cross section view showing that sprinkler head locations comply with NFPA 13 Chapter 8. 18. Standard and extended coverage pendant and upright heads must be located between 1 to 12 inches from the ceiling. [NFPA 13 8.6.4.1.1, and 8.8.4.1.1] Standard and extended coverage sidewall heads must be located between 4 to 6 inches from the ceiling. [NFPA 13 8.7, and 8.9] 19. Where a water curtain is used to protect glass walls and inoperable windows, specify that specific application window sprinklers are used. Unless otherwise listed: (1) the system must be a wet system for interior use or a deluge system for exterior use;

(2) the glazing must be nonoperable, heat strengthened, tempered, single or double paned, minimum ¼ in. thick; (3) without any horizontal framing members for the glazing frame; (4) the frame must be noncombustible with a standard EPDM rubber gasket seal; (5) the maximum height of the window assembly is 13 ft; (6) heads spacing is a maximum of 6 ft on center or within each glazing segment; and (7) some method must be used to keep combustibles a minimum of 2 in. from the glass. [Office Policy] The sprinkler heads must be arranged so that the entire surface of the glass is wet upon operation of the sprinklers. 20. Provide an inspector s test pipe per NFPA 13 8.17.4.2 and NFPA 13 8.17.4.3. 21. Show the location and type of hanger systems used. [NFPA 13 Chapter 9] 22. Provide earthquake protection sway bracing at locations specified by NFPA 13 9.3.5. Provide straps for C clamps used to attach hangers to the building structure. [NFPA 13 9.3.7] Secure the top of the riser with a 4way sway brace. [See NFPA 13 9.3.5.5.1] Show type and location of branch line restraints. [NFPA 13 9.3.6] Alternative methods are permitted based on a seismic analysis by a registered engineer. [NFPA 13 9.3.1.2] Show pipe sleeve size and location for required clearance around sprinkler piping passing through floors, walls, and foundations (concrete floors/walls or CMU walls). [NFPA 13 9.3.4] 23. Provide flexible couplings at flexure joints and, where required, provide clearance around piping passing through floors, walls, and foundations. [NFPA 13 9.3.2.1 and 9.3.4] 24. The entire system must be drainable. Sprinkler feed pipes must be pitched for drainage (i.e., trapped piping, dry pipe systems, low points, etc.). [NFPA 13 8.16.2.2] Provide auxiliary drains for trapped piping. [NFPA 13 8.16.2.5] All drains must discharge outside or to a drain connection. [NFPA 13 8.16.2.4.4] 25. The following information must be provided for dry pipe systems. A. Provide the capacity of the dry sprinkler system. A maximum capacity of 750 gallon per riser is permitted, see the reference for exceptions. Provide the individual capacities of both systems when connecting to an existing dry system. [NFPA 13 7.2.3.4] B. Provide a quick opening device for dry sprinkler systems with capacities over 500 gallonsper riser. [NFPA 13 7.2.3.3] A check valve must be installed between the quick opening device and the dry valve. [NFPA 13 7.2.4.6] C. Gridded systems are not allowed for dry systems. [NFPA 13 7.2.3.10] D. Combined dry pipe and preaction systems must be equipped with a listed quick opening device at the dry pipe valve. [NFPA 13 7.4.3.8] E. Show the air filling connection, compressor, control, check, and relief valves, etc. [NFPA

13 7.2.6] Furnish specifications for the compressor. Identify whether it will be operated automatically or manually. [NFPA 13 7.2.6.5 and.6] F. Sprinkler heads installed on dry pipe systems must be one of the five types listed in NFPA 13 7.2.2. 26. The proposed sprinkler system solenoid valve used for elevator hoistways and machine rooms would have to be tested and listed for this particular application and be supervised by the fire alarm system to satisfy the code. [NFPA 13 6.1.1 and 8.15.1.1.2] The use of a stand alone solenoid valve serving a dry system branch line for elevator hoistways and machine rooms is not an acceptable alternative to a preaction sprinkler system. Calculations 1. Verify the occupancy classification related to sprinkler installation and their water supply: light hazard; ordinary hazard (Group 1 and 2); extra hazard (Group 1 and 2); and special occupancy hazard. [NFPA 13 5.2 through 5.5] 2. Sprinklers in concealed spaces having no access for storage (unused attics) or other use must be installed in accordance with the requirements of light hazard occupancies, otherwise ordinary hazard. [NFPA 13 8.15.1.3] 3. Laboratories using chemicals must be ordinary hazard Group 1 or 2. [NFPA 21 9.1, NFPA] 4. Commercial kitchens must be protected to ordinary hazard Group 1 requirements. [NFPA 13 A.5.3.1] 5. Large stack rooms in libraries must be protected to ordinary hazard Group 2 requirements. [NFPA A.13 5.3.2] 6. Stage area must be protected to ordinary hazard Group 2 requirements. [NFPA A.13 5.3.2] 7. The water supply for sprinklers only (hydraulic calculation methods) must be determined either from the area/density curves of Figure 11.2.3.1.1 in accordance with the method of 11.2.3.3 or be based upon the room design method in accordance with 11.2.3.4 [NFPA 13 11.2.3] 8. Provide 1 copy of hydraulic calculations referenced from a test hydrant adding the hose stream demand to the water supply for sprinklers. [NFPA 13 11.2.3 and Table 11.2.3.1.2] 9. Provide or clarify any necessary hydraulic reference points on the drawings. 10. The system area of operation must be increased by 30 percent without raising density for dry and double interlock preaction systems. [NFPA 13 11.2.3.2.5] 11. For wet systems with sloped ceilings see NFPA 13 11.2.3.2.4. 12. For atrium and/or glass wall sprinkler requirements see the Sprinkler Design Intent correction list information.

13. Provide a pressure reducing valve where the potential exists for water pressures exceeding 175 psi. [NFPA 13 8.16.1.2] 14. A minimum of two additional sets of calculations must be submitted to demonstrate peaking of the demand area for gridded systems. A single set of calculations may be submitted where a computer program is used. [NFPA 13 122.4.4.4]