MEGATRON MODEL 2, 3, 4, and 5

Similar documents
OUTLET HOT INLET COLD INLET INSTALLATION

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

TA-300, TA-300-LF, TA-350, TA-350-LF

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

OUTLET LEONARDH THERMOSTATIC INSTALLATION

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

HOT INLET COLD INLET INSTALLATION

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS

OUTLET LEONARD THERMOSTATIC INSTALLATION

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

LEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, , " Maximum Operating Pressure 125PSI (8.6 Bar).

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

MODEL 210, 210-LF THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING INSTRUCTIONS

MEGATRON MODEL TA, TA-LF

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

Installation S

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Installation S

Installation S

Installation S

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Installation Instructions / Warranty

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Installation Instructions / Warranty. Metris 31060XX XX XX1

CLASSIC HIGH LOW MANIFOLD SYSTEMS

Installation S

Installation Instructions / Warranty

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Installation Manual. Models 99168, 99169, 99170

Instruction Manual. Cheese Warmer with Pump

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

Installation & Operation Manual

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installation Instructions / Warranty. Starck 10111XX XX XX1

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

PALARRE, ROCHELLE WATER-GUARD VITREOUS CHINA SIPHON JET TOILET

Installation Instructions / Warranty. Massaud

Installation & Operation Manual

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

Installation Instructions / Warranty. PuraVida 15775XX1

1. Connect Hose Attach a garden hose to the swivel nut hose fitting.

Instruction Manual. Nacho Cheese Dispenser and Warmer

TUB AND SHOWER FAUCET

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET

Installation Instructions / Warranty

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

SuperKlean Washdown Products

52 SAN LUCAS CEILING FAN

Installation & Operation Manual

Installation Instructions / Warranty

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

Installation Instructions / Warranty

ST. KITTS CEILING FAN

Installation Instructions

WATER TEMPERATURE CONTROL SYSTEMS

RK/ RK Oxygen Detector Operator s Manual

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Transcription:

MEGATRON MODEL 2, 3, 4, and 5 BULLETIN M-1020A 2/02 INSTALLATION ADJUSTMENT SERVICE COMPLETE WATER TEMPERATURE CONTROL STATION DOMESTIC OUTLET TEST/SETUP CONNETION RETURN LINE FROM BUILDING RETURN LINE TO HOT WATER SOURCE HOT SUPPLY COLD SUPPLY 1. Type TM manifold systems are factory preassembled and tested and include large and small thermostatic water mixing valves which function as a system to meet both high and low demand for tempered water. 2. System should be installed at a location where it can easily be cleaned, adjusted or repaired. INSTALLATION 3. System supplies must be connected as shown (Hot-left, Cold-right). Connect return piping as shown. Exercise caution when soldering 4. Flush pipes thoroughly after system has been connected. 5. Refer to page 4 of this bulletin for correct Setup Instructions. Maximum Operating Pressure 125PSI (860kpa) for Hot and Cold Water CAUTION All thermostatic water mixing valves have limitations. They will not provide the desired accuracy outside their flow capacity range. Consult the capacity chart on page 8. Minimum flow must be no less than as shown. REMEMBER! THIS IS A CONTROL SYSTEM WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANCE GUIDE AND RECORD MGR-1000). 1360 Elmwood Avenue, Cranston, R. I. 02910 USA Phone: 401.461.1200 Fax: 401.941.5310 Email: info@leonardvalve.com Toll free technical support number 1.888.797.4456 1

ADJUSTMENT AND SERVICE Leonard Thermostatic Water Mixing Valves are simple in design and may be easily cleaned, adjusted and repaired. If installation is accessible, servicing may be completed without disconnecting the valves. NOTE: High Low Manifold Systems include Thermostatic Water Mixing Valves which must be regularly maintained to provide best performance. Frequency of cleaning depends on quality of local water conditions and usage. See Maintenance Guide and Record MGR-1000 WARNING These mixing valves are equipped with an adjustable high temperature limit stop factory set at approximately 120ºF (49ºC) with an incoming hot water supply temperature of 150ºF (65.5ºC). If the hot water supply temperature of the job is greater than 150ºF (65.5ºC), the valves when turned to full HOT will deliver water in excess of 120ºF (49ºC) and the limit stops MUST BE RESET BY THE INSTALLER! TO RESET ADJUSTABLE HIGH TEMPERATURE LIMIT STOP: LARGE MIXING VALVE (TM-50, 80, 125 OR 150) FINE ADJUSTMENT SCREW SMALL MIXING VALVE (M20) STOP WEB POINTER STOP SCREW SNAP CAP 1. Remove SNAP CAP, SCREW & WASHER. Remove POINTER. 2. Temporarily place POINTER on the spline rod, turn RIGHT for warmer temperature, turn LEFT for cooler temperature. When valve is delivering warmest temperature desired, remove the pointer. 3. Replace POINTER on the spline rod so that its RIGHT edge is resting against the STOP SCREW located on the RIGHT SIDE OF THE COVER. 4. The new maximum temperature has now been set. Test this temperature by holding a thermometer under the flow of water to be certain it is as desired. RETAINING RING 1. Remove HANDLE, RETAINING RING and STOP 2. Temporarily place POINTER on the spline rod. Turn LEFT for warmer temperature, turn RIGHT for cooler temperature. When valve is delivering warmest temperature desired, remove the pointer. 3. Push stop on rod so that its LEFT edge is resting against the fine adjustment screw on cover. 4. Turn fine adjustment screw if necessary, (clockwise for slightly higher temperature, counter clockwise for slightly lower temperature). 5. The new maximum temperature has now been set. Test this temperature by holding a thermometer under the flow of water to be certain it is as desired. IMPORTANT! BOTH MIXING VALVES MUST BE SET AT THE SAME OPERATING TEMPERATURE Check for significant variations in outlet flow. Thermostatic valves will NOT provide the desired accuracy outside their flow capacity range. Minimum flows must be no less than shown (see Flow Capacities, page 8). If installed on a recirculated hot water system, make certain the valve is piped according to Leonard Required Piping Method #2 PRV (see page 3). 2

REQUIRED METHOD OF PIPING (RECIRCULATED DOMESTIC WATER SYSTEMS) METHOD #4/PRV DOMESTIC WATER RETURN LINE FROM BUILDING HOT WATER SOURCE HEAT TRAP BALANCING VALVE #2 BALANCING VALVE #1 RETURN LINE TO HOT WATER SOURCE COLD SUPPLY SEE BULLETIN TB-120 FOR ADDITIONAL PIPING METHODS DESIGNED FOR SPECIAL INSTALLATIONS. THIS PIPING METHOD IS NOT TO BE USED FOR MORE THAN ONE BUILDING PROCEDURE TO BALANCE RECIRCULATION SYSTEM 1. MAKE SURE NO WATER IS BEING DRAWN IN THE BUILDING. OPEN BALANCING VALVE #1 AND BALANCING VALVE #2 APPROXIMATELY HALF WAY AND START CIRCULATOR. 2. OBSERVE TEMPERATURE UNTIL IT STABILIZES. 3. CLOSE BALANCING VALVE #1 SLIGHTLY IF TEMPERATURE IS TOO HOT, OR OPEN IT SLIGHTLY IF TEMPERATURE IS TOO COLD AND ALLOW TEMPERATURE TO STABILIZE. REPEAT UNTIL DESIRED RECIRCULATED TEMPERATURE IS SET. 4. IF UNABLE TO REACH DESIRED TEMPERATURE OPEN BALLVALVE #2 FULL, REPEAT STEPS 2 & 3. REMEMBER! THIS IS A CONTROL DEVICE WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANCE GUIDE AND RECORD, MGR-1000). 3

SETUP INSTRUCTIONS PRESSURE GAUGE S1 DOMESTIC WATER V2 LARGE TM VALVE BALL VALVE THERMOMETER T1 V1 SMALL TM VALVE HOT SUPPLY COLD SUPPLY 1. TM-186 High-Low Unit MUST be piped according to Method #2 PRV (see page 3). To balance recirculated domestic water systems, see page 3. 2. Make sure full hot and cold supplies to this assembly are operating. The temperature of the hot water source must be properly set and maintained. 3. The circulator (if used) must be turned OFF before setup. 4. Turn on enough fixtures for a flow of at least * downstream from this system. Make sure each fixture is set to deliver full "HOT" water. 9. Turn off enough fixtures downstream from this unit to reduce flow to approximately 4 GPM (15 l/min.) 10. After reducing flow observe the temperature at Thermometer T1. Note: the temperature should drop 15 to 20ºF (8 to 11ºC) from step 7. 11. If the temperature dropped MORE THAN 20ºF (11ºC), turn nut S1 clockwise until it has dropped 15 to 20ºF (8 to 11ºC). 12. If the temperature has dropped LESS THAN 15ºF (8ºC), turn nut S1 counterclockwise until it has dropped 15 to 20ºF (8 to 11ºC). * 8 GPM (30 l/min.) if large TM valve is a TM-50 *12 GPM (45 l/min.) if large TM valve is a TM-80 *18 GPM (68 l/min.) if large TM valve is a TM-125 *18 GPM (68 l/min.) if large TM valve is a TM-150 5. Close outlet Valve V1 at the smaller Type TM Valve and set the smaller TM valve to full "COLD". 6. Make sure Valve V2 at the large Type TM Valve is in the full open position. 7. Set outlet temperature of the large Type TM Valve to the required level. 8. Open outlet Valve V1 at the small TM Valve. 13. Shut outlet Valve V2 at the large TM valve. 14. Set outlet temperature of the small TM valve to the same temperature as the large TM Valve. 15. Open outlet Valve V2. System is operational. NOTE! FOR OUTLET SETUP PIPING ARRANGEMENT, SEE PAGE 8. 4

INSTRUCTIONS FOR SERVICING LARGER TM VALVE INSTRUCTIONS FOR SERVICING SMALLER TM VALVE 1. Remove snap cap, screw and washer, friction spring and pointer. Shut off hot and cold supplies to this valve. 2. Remove cover screws and cover, to which the thermostat group is attached. 1. Remove handle. Turn off hot and cold supplies at screwdriver checkstops. Remove M20-2C cover screws to release cover and thermostatic control assembly. 3. To clean port sleeve assembly (the thimble must slide freely on the port sleeve): unscrew the check nut as far as it will go, then screw the port sleeve nut into the base. The port sleeve and thimble may then be lifted out. 4. Clean with a non-corrosive cleaning solution. DO NOT USE ABRASIVES! The port sleeve should be reassembled in the valve with the shoulder to the left. 5. When reassembling, make sure driving ball of thermostat group engages the ball socket of the port sleeve assembly. 2. To remove bridge assembly, M20-1-8B, remove pointer rod nut (M20-10B) and pull bridge assembly off control rod. Do not misplace M20-14B driving stud. 3. To clean submerge bridge assembly in clean water or noncorrosive cleaning solution. DO NOT USE ABRASIVES! Be certain thimble moves freely on port sleeve. Note! Driving stud (M20-14B) must engage slot in thimble when reassembling. 4. To disassemble bridge assembly, see drawing page 7 (remove M20-5B holder nuts with screwdriver in slots provided). TROUBLESHOOTING INSTRUCTIONS Note: Provide valve serial number when ordering parts for either valve! Large Valve: Small Valve: PACKING & GASKETS PORT SLEEVE/BRIDGE ASSEMBLY 1. Leaks at stem. 2. Leak between valve cover and base. 3. Valve delivers either all hot or all cold water, or will not mix consistently. Kit # 1/ ("50" If large valve is a TM50 or TM80, "125" for TM-125 or 150) Kit # R ("50" for TM50 or 80,"125",for TM- 125 or 150) or TGM- 1/ ("50" or "125") Kit #1/M20 (Packings & Gaskets Kit #R/M20 (Rebuilding Kit) Or M20-1-8B Bridge Assembly THERMOSTAT GROUP 4. After cleaning or replacing port sleeve assembly valve performance is not consistent. Kit # R/ ("50" or "125") or TGM-2 ("50"or"125") Kit #R/M20 (Rebuilding Kit) Or M20-G2 Thermostat Group CHECKSTOPS 5. Hot water by-pass into cold line (or cold into hot). 6. Supplies cannot be shut off completely. Supplies leak at checkstop bonnets. Kit #2/ ("50" for TM-50 or 80,"125" for TM-125 or 150) Kit #4/M20 (Checkstop Kit) See pages 6 & 7 for Parts Breakdowns 5

LARGE TM VALVE PARTS CHECKSTOP PARTS TO CLEAN THERMOSTAT GROUP IF A DEPOSIT HAS COLLECTED ON THE THERMOSTAT GROUP (TGM-2) BRUSH IN A NON-CORROSIVE CLEANING SOLUTION. REPAIR KITS Lock Type Pointer (Suffix LTR) Some TM valves are furnished with lockable pointers. See part noted. REMEMBER! THIS IS A CONTROL DEVICE WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANCE GUIDE AND RECORD, MGR-1000) NOTE: AFTER INSTALLING NEW PARTS IT WILL BE NECESSARY TO RESET THE ADJUSTABLE HIGH TEMPERATURE LIMIT STOP ON EACH VALVE (SEE PAGE 2). * 50 for TM-50/80 125 for TM-125/150 6

SMALL TM VALVE PARTS CHECKSTOP PARTS TO CLEAN THERMOSTAT GROUP IF A DEPOSIT HAS COLLECTED ON THE THERMOSTAT GROUP (TGM-2) BRUSH IN A NON-CORROSIVE CLEANING SOLUTION. REPAIR KITS Lock Type Pointer (Suffix LTR) Some TM valves are furnished with lockable pointers. See part noted. REMEMBER! THIS IS A CONTROL DEVICE WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANCE GUIDE AND RECORD, MGR-1000) NOTE: AFTER INSTALLING NEW PARTS IT WILL BE NECESSARY TO RESET THE ADJUSTABLE HIGH TEMPERATURE LIMIT STOP ON EACH VALVE (SEE PAGE 2). 7

OUTLET SETUP PIPING BALL VALVE TEMPERED WATER TO BUILDING This station is equipped with the test/setup connection to aid the installer. When setting up the station, shut off the outlet ball valve and open ball valve A to the required flow and follow instructions on page 4. When station has been setup, close ball valve A and open outlet ball valve to set the recirculation temperature as described on page 3. 3/4" HOSE FTG. WITH CAP BALL VALVE (A) OUTLET OF HIGH-LOW SYSTEM CAUTION! ALL THERMOSTATIC WATER MIXING VALVES AND SYSTEMS HAVE LIMITATIONS! THEY WILL NOT PROVIDE THE DESIRED PERFORMANCE OUTSIDE OF THEIR FLOW CAPACITY RANGE! CONSULT THE CAPACITY CHART BELOW AND OBSERVE MINIMUM FLOWS SHOWN. FLOW CAPACITIES TROUBLESHOOTING PRESSURE REGULATING VALVE When replacement parts are required for the pressure regulating valve, the following information must be given: SYMPTOM: Manufacturer of PRV: Type: Serial number: 1. If PRV leaks by adjusting screw or if no pressure adjustment is possible. (This information is found on the tag attached to the adjusting screw). Repair Kit: Kit R/PRV 2. If low pressure in building Low Pressure Spring LP/PRV 3.If outlet pressure has to be 70 to 100 PSI High Pressure Spring HP/PRV LIMITED WARRANTY Leonard Valve Company warrants the original purchaser that products manufactured by them (not by others) will be free from defects in materials and workmanship under normal conditions of use, when properly installed and maintained in accordance with Leonard Valve Company's instructions, for a period of one year from date of shipment. During this period the Leonard Valve Company will at its option repair or replace any product, or part thereof, which shall be returned, freight prepaid, to the Leonard factory and determined by Leonard to be defective in materials or workmanship. There are no warranties, express or implied, which extend beyond the description contained herein. There are no implied warranties of merchantability or of fitness for a particular purpose. In no event will Leonard be liable for labor or incidental or consequential damages. Any alteration or improper installation or use of the product will void this limited warranty. 8