Two-Stage Air Conditioners

Similar documents
Ruud Achiever Series Air Conditioners

Ruud Achiever Two-Stage Air Conditioners

Ruud Achiever Plus Series Two-Stage Air Conditioners

Ruud Achiever Plus Series Two-Stage Air Conditioners

Ruud Ultra Series Variable Speed Heat Pumps

Ruud Achiever Series Heat Pump

Rheem Classic Plus Series Two-Stage Air Conditioners

Ruud Ultra Series Variable Speed Air Conditioners

Rheem Commercial High-Efficiency Condensing Units

Rheem Prestige Series Variable Speed Heat Pumps

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

Rheem Prestige Series Variable Speed Air Conditioners

Rheem Prestige Series Variable Speed Heat Pumps

Ruud Ultra Series Variable Speed Heat Pumps

Commercial High-Efficiency Condensing Units

Rheem Prestige Series Variable Speed Air Conditioners

Rheem Prestige Series Variable Speed Heat Pumps

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Ruud Achiever Plus Series Three-Stage Heat Pump

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

14 AC x

PACKAGE AIR CONDITIONER

2 shp 13 lc 1 36 t - 1 a

PAJ3. Product Specifications

N4A6. Product Specifications

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

16 SEER TWO-STAGE AIR CONDITIONERS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

R 410A Ducted Horizontal Air Conditioner

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

MACH N-407 Heat Pump Air-Cooled Chiller

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

T S A 048 S 4 N 4 1 T

Commercial High-Efficiency Condensing Units

MAC N-407 Air-Cooled Chiller

Advance Product Data

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

WCH5**4. Product Specifications

R4H4. Product Specifications

R4H4. Product Specifications

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Advance Product Data

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

T P A 120 S 4 S N 1 Y

Split System Cooling Product Data

Product Data. Fig. 1 - Unit 50VR -A

Split System Cooling Product Data

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

13 SEER CONDENSING UNITS

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

MAC-120HE-03 Air-Cooled Chiller

Rheem High Efficiency Air Handler

N4H4. Product Specifications

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

HIGH EFFICIENCY AIR HANDLER

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Split System Cooling Product Data

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

TECHNICAL SPECIFICATIONS

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Split System Cooling Product Data

Split System Cooling Product & Performance Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Split System Cooling Product Data

50TM COMBINATION HEATING/COOLING UNITS

HIGH-EFFICIENCY CONDENSING UNITS

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

13 GEP A L P - 1 A

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Transcription:

Seasonal Energy Efficiency atio - SEE THIS MODEL 10.0 USES LESS ENEGY 17.00 17.0 MODEL: SA17 Two-Stage Air Conditioners FOM NO. ASC-223 EV. 1 Sure Comfort SA17 Two-Stage Air Conditioners Efficiencies up to 17 SEE/13 EE Nominal Sizes 2, 3, 4 & 5 Ton [7.03, 10.6, 14.06 & 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov. New composite base pan dampens sound, wire grille, eliminates corrosion and reduces number of fasteners needed Powder coat paint system for a long lasting professional finish The Two Stage Copeland Scroll UltraTech Compressor modulates between two capacity settings 67% and 100% providing more precise temperature control, lower humidity and greater efficiency in comparison to single stage compressors. It uses 70% fewer moving parts which also increases efficiency and reliability. Modern cabinet aesthetics increased curb appeal with visually appealing design Wire grille provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity Optimized fan orifice optimizes airflow and reduces unit sound ust resistant screws confirmed through 1500-hour salt spray testing Service valve has between 3"-4"-5" valve space provides a minimum working area of 27-square inches for easier access 15" wide, industry leading corner service access makes repairs easier and faster. External gauge port access allows easy connection of low-loss gauge ports Single-row condenser coil makes unit lighter and allows thorough coil cleaning to maintain out of the box performance Fewer cabinet fasteners allow for faster access to internal components and hassle-free panel removal Service trays hold fasteners or caps during service calls Q code provides technical information on demand for faster service calls Fan motor harness with extra long wires allows unit top to be removed without disconnecting fan wire. High and low pressure standard on all models. www.surecomfort.com

Table of Contents Standard Feature...3 Available SKUs...3 Features & Benefits...4-5 Model Number Identification...6-7 General Data/Electrical Data...8 Accessories...9 Weighted Sound Power...9 Unit Dimensions...10 Clearances...11 Wiring Diagrams...12 Application Guidelines...12 efrigerant Line Size Information...13-14 Performance Data...15-17 Guide Specifications...18 Limited Warranty...19 2 www.surecomfort.com

Standard Feature Table STANDAD FEATUES Feature 24 36 48 60-410A efrigerant Maximum SEE 17 17 17 16 Maximum EE 13 13 13 12.5 Two Stage Copeland Scroll UltraTech Compressor Field Installed Filter Drier Front Seating Service Valves Internal Pressure elief Valve Internal Thermal Overload Long Line capability Low Ambient capability with Kit Expanded Valve Space Composite Basepan 1 Screw Control Box Access 15" Access to Internal Components Optimized Venturi Airflow Single row condenser coil Powder coated paint ust resistant screws Q code External gauge ports Service trays = Standard Available SKUs Available Models SA1724AJ2NB SA1736AJ2NB SA1748AJ2NB SA1760AJ2NB Description Sure Comfort Series 2 ton 17 SEE Two Stage Air Conditioner-208/230/1/60 Sure Comfort Series 3 ton 17 SEE Two Stage Air Conditioner-208/230/1/60 Sure Comfort Series 4 ton 17 SEE Two Stage Air Conditioner-208/230/1/60 Sure Comfort Series 5 ton 17 SEE Two Stage Air Conditioner-208/230/1/60 www.surecomfort.com 3

Introduction to SA17 Air Conditioner The SA17 is our 17 SEE air conditioner and is part of the Sure Comfort air conditioner product line that extends from 13 to 17 SEE. This highly featured and reliable air conditioner is designed for years of reliable, efficient operation when matched with Sure Comfort indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators. Our unique composite base ( 1 ) reduces sound emission, eliminates rattles, reduces fasteners, eliminates corrosion and has integrated brass compressor attachment inserts ( 2 ). Furthermore it has incorporated into the design, water management features, means for hand placement ( 3 ) for unit maneuvering, screw trays ( 4 ) and inserts for lifting off unit pad. ( 5 ) 1 If in the rare event, greater access is needed to internal components, such as the compressor, the top cover can be removed easily. Furthermore with the top cover removed the control panel can be removed ( 12 ). Extra wire length is incorporated into each outdoor fan and compressor so top cover and control panel can be positioned next to the unit. With minimal effort the plug can be removed from the compressor and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit ( 13 ). Outdoor coil heights range from as short as 22" to 32", aiding access to the compressor. Disassembly to this degree and complete reassembly only takes a first time service technician less than 10 minutes. ( 13 ) 14 14 14 Service Valves ( 6 ) are rigidly mounted in the composite base with 3" between suction and discharge valves, 4" clearance below service valves and a minimum of 5" above the service valves, creating industry leading installation ease. 6 2 4 4 3 The minimum 27 square-inches around the service valves allows ample room to remove service valve schrader prior to brazing, plenty of clearance for easy brazing of the suction and discharge lines to service valve outlets, easy access and hookup of low loss refrigerant gauges ( 7 ), and access to the service valve caps for opening. For applications with long-line lengths up to 250 feet total equivalent length, up to 200 feet condenser above evaporator, or up to 80 feet evaporator above condenser, the long-line instructions in the installation manual should be followed. 5 12 All SA17 units utilize single row coils ( 14 ) making cleaning easy and complete, restoring the performance of the air conditioner back to out of the box performance levels year after year. The outdoor fan motor has sleeve bearings and is inherently protected. The motor is totally enclosed for maximum protection from weather, dust and corrosion. Access to the outdoor fan is made by removing four fasteners from the fan grille. The outdoor fan can be removed from the fan grille by removing 4 fasteners in the rare case outdoor fan motor fails. Each cabinet has optimized composite ( 15 ) fan orifice assuring efficient and quiet airflow. 13 15 7 8 11 10 9 Controls are accessed from the corner of the unit by removing only three fasteners from the control access cover, revealing the industry s largest 15" wide and 14" tall control area ( 8 ). With all this room in the control area the high voltage electrical whip ( 9 ) can easily be inserted through the right size opening in the bottom of the control area. outing it leads directly to contractor lugs for connection. The low voltage control wires ( 10 ) are easily connected to units low voltage wiring. If contactor or capacitor ( 11 ) needs to be replaced there is more than adequate space to make the repair. 4 www.surecomfort.com

All cabinet painted parts have powder post paint ( 16 ) achieving 1000 hour salt spray rating, allowing the cabinet to retain its aesthetics throughout its life. 16 Scroll compressors with standard internal pressure relief and internal thermal overload are used on all capacities assuring longevity of high efficient and quiet operation for the life of the product. Each unit is shipped with filter drier for field installation and will trap any moisture or dirt that could contaminate the refrigerant system. 20 18 Cabinets are durable and strong due to the composite base pan ( 17 ), wire grille ( 18 ), and drawn top cover ( 19 ). Each SA17 capacity has undergone rigorous psychometric testing to assure performance ratings of capacity, SEE and EE per AHI Standard 210/240 rating conditions. Also each unit bears the UL mark and each unit is certified to UL 1995 safety standards. Each unit has undergone specific strain and modal testing to assure tubing ( 20 ) is outside the units natural frequency and that the suction and discharge lines connected to the compressor withstand any starting, steady state operation or shut down forces imposed by the compressor. All units have been sound tested in sound chamber to AHI 270 rating conditions, and A-weighted Sound Power Level tables produced, assuring units have acceptable noise qualities (see page 9). Each unit has been ran in cooling operation at 95 F and 82 F and sound ratings for the SA17 range from as low as 74 dba to 77 dba. All units have been ship tested to assure units meet stringent over the road shipping conditions. As manufactured all units in the SA17 family have cooling capability to 55 F. Addition of low ambient control will allow the unit to operate down to 0 F. Factory testing is performed on each unit. All component parts meet well defined specification and continually go through receiving inspections. Each component installed on a unit is scanned, assuring correct component utilization for a given unit capacity and voltage. All condenser coils are leak tested with pressurization test to 550# s and once installed and assembled, each units complete refrigerant system is helium leak tested. All units are fully charged from the factory for up to 15 feet of piping. All units are factory run tested. The SA17 has a 10-year conditional compressor and parts warranty (registration required). 17 19 Optional Accessories (efer to accessory chart for model #) Compressor Crankcase Heater Protects against refrigerant migration that can occur during low ambient operation Compressor Sound Cover einforced vinyl compressor cover containing a 1½ inch thick batt of fiberglass insulation Open edges are sealed with a one-inch wide hook and loop fastening tape Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor, this type of motor normally does not need a potential relay and start capacitor Kit may be required to increase the compressor starting torque, in conditions such as low voltage Low Ambient Kit Air conditioners operate satisfactorily in the cooling mode down to 55 F outdoor air temperature without any additional controls This Kit can be added in the field enabling unit to operate properly down to 0 in the cooling mode Crankcase heater and freezestat should be installed on compressors equipped with a low ambient kit 3"/6"/12" Gray high density polyethylene feet are available to raise unit off of mounting surface away from moisture Low Pressure Can be added in field enabling the unit to shut off compressor on loss of charge NOTE: Unit can be purchased with high and low pressure installed at factory. (efer to SKU list) High Pressure Can be added in field enabling unit to shut off compressor if unit loses outdoor fan operation. NOTE: Unit can be purchased with high and low pressure installed at factory. (efer to SKU list) Decorative Top Can be installed on fan grille www.surecomfort.com 5

Air Conditioners* S A 17 24 A J 2 C B * Brand Product Category Sure Comfort A - Air Conditioners 13-13 SEE 14-14 SEE 16-16 SEE 17-17 SEE *See page 3 for available SKU s. SEE Capacity BTU/H 18-18,000 [5.28 kw] 24-24,000 [7.03 kw] 30-30,000 [8.79 kw] 36-36,000 [10.55 kw] 42-42,000 [12.31 kw] 48-48,000 [14.07 kw] 60-60,000 [17.58 kw] Major Series* Voltage Type Controls Minor Series** Option Code A - 1st Design B - 2nd Design J - 1ph, 208-230/60 C - 3ph, 208-230/60 1 - Single-stage 2 - Two-stage N - Non-Communicating A - 1st Design B - High and low pressure control N/A Heat Pumps (For eference)** S P 16 24 A J V N A * Brand Product Category Sure Comfort P - Heat Pump 13-13 SEE 14-14 SEE 15-15 SEE 16-16 SEE SEE Capacity BTU/H 18-18,000 [5.28 kw] 24-24,000 [7.03 kw] 30-30,000 [8.79 kw] 36-36,000 [10.55 kw] 42-42,000 [12.31 kw] 48-48,000 [14.07 kw] 60-60,000 [17.58 kw] Major Series* Voltage Type Controls Minor Series** Option Code A - 1st Design J - 1ph, 208-230/60 C - 3ph, 208-230/60 D - 3ph, 460/60 1 - Single-stage 2 - Two-stage N - Non-Communicating A - 1st Design N/A Furnace Coils (For eference)** T C F 24 17 S E A M C A * Brand Product Category Tradebrand C - Evap Coil F - Furn Coil H - Air-Handler Coil Type Capacity BTU/H 24-24,000 [7.03 kw] 36-36,000 [10.55 kw] 48-48,000 [14.07 kw] 60-60,000 [17.58 kw] Width Efficiency Metering Device 14-14" 17-17.5" 21-21" 24-24.5" S- Standard Eff. M- Mid Eff. H- High Eff. T-TXV E-EEV P-Piston Major Series* A - 1st Design M - Multipoise V - Vertical only/ convertible H - Ded. Horizontal only Orientation Casing Minor Series** Option Code C - Cased U - Uncased A - 1st Design N/A **Model number ID s are for reference only. See available SKU page of applicable spec sheet for table of available SKU s for a specific model. [ ] Designates Metric Conversions 6 www.surecomfort.com

90%+ AFUE Gas Furnaces (For eference)** S 96 V A 70 2 3 17 M S A Brand Series Motor Major ev Input BTU/H Sure Comfort 90-90 AFUE 92-92 AFUE 95-95 AFUE 96-96 AFUE V - Variable speed T - Constant Torque (X-13) P - PSC A - 1st Design 040-42,000 [12.31 kw] 060-56,000 [16.41 kw] 070-70,000 [20.51 kw] 085-84,000 [24.62 kw] 100-98,000 [28.72 kw] 115-112,000 [32.82 kw] Stages Air Flow Cabinet Width 1 - Single-stage 2 - Two-stage M - Modulating 3 - up to 3 ton 5-3 1/2 up to 5 ton 14-14" 17-17.5" 21-21" 24-24.5" Configuration Nox Minor ev M - Multi X - Low Nox S - Standard A - 1st Design 80% AFUE Gas Furnaces (For eference)** S 80 2 V A 075 3 17 M S A Brand Series Stages Motor Major ev Input BTU/H Sure Comfort 80-80+ AFUE 1 - Single-stage 2 - Two-stage V - Variable speed T - Constant Torque (X-13) P - PSC premium S - PSC standard A - 1st Design 050-50,000 [15 kw] 075-75,000 [22 kw] 100-100,000 [29 kw] 125-125,000 [37 kw] 150-150,000 [44 kw] Air Flow Cabinet Width 3 - up to 3 ton 4-2 1/2 to 4 ton 5-3 1/2 up to 5 ton 14-14" 17-17.5" 21-21" 24-24.5" Configuration Nox Minor ev M - Multi D - Down Z - Down & zero clearance down flow X - Low Nox S - Standard A - 1st Design Air Handlers (For eference)** S H 2 T 36 17 S E A C A A 000 * Brand Product Category Sure Comfort H - Air Handler Stages of Airflow 1 - Single-Stage 2 - Two-Stage M - Modulating Motor Type Capacity BTU/H V - Variable Speed C - Constant Torque P - PSC 24-24,000 [7.03 kw] 36-36,000 [10.55 kw] 48-48,000 [14.07 kw] 60-60,000 [17.58 kw] Width Coil Size Metering Device 14-14" 17-17.5" 21-21" 24-24.5" S - Standard Eff. M -Mid Eff. H - High Eff. T - TEV E - EEV P - Piston Major Series* A - 1st Design C -Communicating N -Non-comm Controls Voltage Minor Series** A - 1ph, 115/60 J - 1ph, 208-240/60 D - 3ph, 480/60 Factory Heat Cap A - 1st Design 00 - no factory heat with option code Option Code *TBD **Model number ID s are for reference only. See available SKU page of applicable spec sheet for table of available SKU s for a specific model. [ ] Designates Metric Conversions www.surecomfort.com 7

Physical Data Model No. SA1724A SA1736A SA1748A SA1760A Nominal Tonnage 2.0 3.0 4.0 5.0 Valve Connections Liquid Line O.D. in. 3/8 3/8 3/8 3/8 Suction Line O.D. in. 3/4 3/4 7/8 7/8 efrigerant (-410A) furnished oz.¹ 128 151 204 223 Compressor Type Scroll Outdoor Coil Net face area Outer Coil 19.8 22.2 32.3 32.3 Net face area Inner Coil Tube diameter in. 0.375 0.375 0.375 0.375 Number of rows 1 1 1 1 Fins per inch 20 22 22 22 Outdoor Fan Diameter in. 24 24 26 26 Number of blades 3 3 3 3 Motor hp 1/5 1/5 1/2 1/2 CFM 3326 3540 4251 5133 PM 850 820 646 825 watts 112 112 132 113 Shipping weight lbs. 200 209 297 298 Operating weight lbs. 193 202 290 291 Electrical Data Line Voltage Data (Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection (amps)² 25 35 50 70 Minimum circuit ampacity³ 16 21 32 42 Compressor ated load amps 11.7 15.3 21.2 28.8 Locked rotor amps 58.3 83 104 152.9 Condenser Fan Motor Full load amps 1.4 1.2 5.3 5.3 Locked rotor amps ¹efrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. ²HAC type circuit breaker of fuse. ³efer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. 8 www.surecomfort.com

Accessories Model No. SA1724 SA1736 SA1748 SA1760 Compressor crankcase heater* 44-17402-49 44-17402-49 44-101884-05 44-101884-05 Low ambient control XAD-A08 XAD-A08 XAD-A08 XAD-A08 Freeze Stat 50313 50313 50313 50313 Compressor sound cover 68-23427-26 68-23427-26 68-25217-10 68-25217-10 Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 Heat pump iser 6 in. 686020 686020 686020 686020 Liquid Line Solenoid Solenoid Valve 200D2T3TVLC 200D2T3TVLC 200D3T3TVLC 200D3T3TVLC (24 VAC, 50/60 Hz) Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid Solenoid Valve 200D2T3TVLC 200D2T3TVLC 200D3T3TVLC 200D3T3TVLC (120/240 VAC, 50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V *Crankcase Heater recommended with Low Ambient Kit. Weighted Sound Power Level (dba) Unit Size - Voltage, Series Standard TYPICAL OCTAVE BAND SPECTUM (dba without tone adjustment) ating (dba) 125 250 500 1000 2000 4000 8000 SA1724A 72.5 48.6 53.7 62.9 63.0 60.5 57.3 54.6 SA1736A 72.3 53.1 52.7 60.9 62.4 61.2 58.4 51.6 SA1748A 73.0 46.1 50.4 59.5 64.6 59.6 55.8 54.6 SA1760A 76.7 58.8 60.5 65.6 65.2 62.9 62.4 55.5 NOTE: Tested in accordance with AHI Standard 270-08 (not listed in AHI) www.surecomfort.com 9

Unit Dimensions OPEATING SHIPPING MODEL NO. H (Height) L (Length) W (Width) H (Height) L (Length) W (Width) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm SA1724 35 889 33.75 857 33.75 857 36.75 933 36.38 924 36.38 924 SA1736 39 990 33.75 857 33.75 857 40.75 1035 36.38 924 36.38 924 SA1748 51 1295 35.75 908 35.75 908 52.75 1339 38.38 974 38.38 974 SA1760 51 1295 35.75 908 35.75 908 52.75 1339 38.38 974 38.38 974 [ ] Designates Metric Conversions ST-A1226-24-00 10 www.surecomfort.com

WALL CLEAANCES WALL 6 (152.4) 6 (152.4) 24 (609.6) Service 12 (304.8) 12 (304.8) 6 (152.4) WALL 24 (609.6) 24 recommended 6 minimum 24 (609.6) Service 12 (304.8) ST-A1225-01-00 24 (609.6) Service 24 (609.6) Service 18 (457.2) 24 (609.6) 24 recommended 6 minimum NOTE: NUMBES IN () = mm IMPOTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re-circulation of discharge air. WALL 24 (609.6) Service www.surecomfort.com 11

Thermostat Wiring Diagrams The following figures show the typical wiring diagrams with (-)HPN air handler and (-)AL condensing unit. Cooling and heat pump airflows may need to be adjusted for homeowner comfort once the system is operational. WIE COLO CODE BK BLACK G GEEN P PUPLE Y YELLOW B BOWN GY GAY ED BL BLUE O OANGE W WHITE FIGUE 3 TYPICAL 2-STAGE THEMOSTAT: CONDENSING UNIT WITH ELECTIC HEAT FIGUE 4 TYPICAL TWO-STAGE THEMOSTAT: CONDENSING UNIT WITH ELECTIC HEAT USING A HUMIDISTAT FO DEHUMIDIFICATION*. Typical Two-Stage Thermostat Y1 Y2 G W1 W2 C Typical Two-Stage Thermostat Y1 Y2 G W1 W2 C Humidistat (-)HPN Air Handler (-)HPN Air Handler W1 * W2 Y1 Y2 C G ODD Y Y/BL B W/ (-)AL Condensing Unit Y1 Y2 C L W1 * W2 Y1 Y2 C G ODD Y Y/BL B W/ (-)AL Condensing Unit Y1 Y2 C L WIING INFOMATION Line Voltage -Field Installed - Factory Standard WIING INFOMATION Line Voltage -Field Installed - Factory Standard *See Section 5.11 for proper DIP switch selection. FIGUE 5 TYPICAL TWO-STAGE THEMOSTAT: CONDENSING UNIT WITH ELECTIC HEAT USING A TWO-STAGE THEMOSTAT WITH DEHUMIDIFICATION* Typical Two-Stage Thermostat Y1 Y2 G W1 W2 C DHM FIGUE 6 CONDENSING UNIT WITH ELECTIC HEAT USING A TWO-STAGE THEMOSTAT WITH DEHUMIDIFICATION* Typical Two-Stage Thermostat Y1 Y2 G W1 W2 C DHM L (-)HPN Air Handler W1 * W2 Y1 Y2 C G ODD Y Y/BL B W/ (-)AL Condensing Unit Y1 Y2 C L (-)HPN Air Handler W1 * W2 Y1 Y2 C G ODD Y Y/BL B W/ (-)AL Condensing Unit Y1 Y2 C L Conventional Thermostat Wiring WIING INFOMATION Line Voltage -Field Installed -Factory Standard WIING INFOMATION Line Voltage -Field Installed -Factory Standard *If maximum outlet temperature rise is desired, it is recommended that W1 and W2 be jumpered together. Application Guidelines 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc. 2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55 F (12.8 C). 3. Maximum outdoor operating air temperature is 125 F (51.7 C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 6. Do not apply capillary tube indoor coils to these units. 7. Factory supplied filter drier must be installed. 12 www.surecomfort.com

efrigerant Line Size Information -410A System Capacity Model Liquid Line Size Connection Size (Inch I.D.) [mm] 24 3/8" [9.53] 36 3/8" [9.53] 48 3/8" [9.53] Liquid Line Size (Inch O.D.) [mm] Liquid Line Selection Chart Elevation (Above or Below) Indoor Coil Total Equivalent Length - Feet [m] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [45.72] 150 [45.72] 175 [53.34] 200 [60.96] 225 [68.58] 250 [76.20] 275 [83.82] 300 [91.44] Maximum Vertical Separation Feet [m] 1/4 [6.35] 25 [7.62] 45 [13.72] 20 [6.1] N/ N/ N/ N/ N/ N/ N/ N/ N/ 5/16 [7.94] 25 [7.62] 50 [15.24] 75 [22.86] 70 [21.34] 65 [19.81] 55 [16.76] 50 [15.24] 45 [13.72] 40 [12.19] 30 [9.14] 25 [7.62] 20 [6.1] 3/8 [9.53] 25 [7.62] 50 [15.24] 75 [22.86] 85 [25.91] 85 [25.91] 80 [24.38] 80 [24.38] 80 [24.38] 75 [22.86] 75 [22.86] 70 [21.34] 70 [21.34] 7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 90 [27.43] 90 [27.43] 90 [27.43] 90 [27.43] 90 [27.43] 85 [25.91] 85 [25.91] 85 [25.91] 85 [25.91] 1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 95 [28.96] 95 [28.96] 95 [28.96] 90 [27.43] 90 [27.43] 90 [27.43] 90 [27.43] 90 [27.43] 90 [27.43] 1/4 [6.35] 25 [7.62] N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 5/16 [7.94] 25 [7.62] 50 [15.24] 45 [13.72] 35 [10.67] 20 [6.1] 5 [1.52] N/ N/ N/ N/ N/ N/ 3/8 [9.53] 25 [7.62] 50 [15.24] 70 [21.34] 65 [19.81] 60 [18.29] 60 [18.29] 55 [16.76] 50 [15.24] 45 [13.72] 40 [12.19] 35 [10.67] 30 [9.14] 7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 75 [22.86] 75 [22.86] 75 [22.86] 70 [21.34] 70 [21.34] 70 [21.34] 65 [19.81] 65 [19.81] 60 [18.29] 1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 80 [24.38] 80 [24.38] 80 [24.38] 80 [24.38] 80 [24.38] 75 [22.86] 75 [22.86] 75 [22.86] 75 [22.86] 1/4 [6.35] N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 5/16 [7.94] 25 [7.62] 50 [15.24] 25 [7.62] N/ N/ N/ N/ N/ N/ N/ N/ N/ 3/8 [9.53] 25 [7.62] 50 [15.24] 70 [21.34] 60 [18.29] 55 [16.76] 45 [13.72] 40 [12.19] 30 [9.14] 25 [7.62] 15 [4.57] 10 [3.05] N/ 7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 80 [24.38] 75 [22.86] 75 [22.86] 70 [21.34] 65 [19.81] 65 [19.81] 60 [18.29] 55 [16.76] 55 [16.76] 1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 85 [25.91] 85 [25.91] 80 [24.38] 80 [24.38] 80 [24.38] 80 [24.38] 75 [22.86] 75 [22.86] 75 [22.86] 1/4 [6.35] N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 5/16 [7.94] 25 [7.62] 30 [9.14] N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 60 3/8" [9.53] 3/8 [9.53] 25 [7.62] 50 [15.24] 55 [16.76] 45 [13.72] 35 [10.67] 25 [7.62] 15 [4.57] 5 [1.52] N/ N/ N/ N/ 7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 70 [21.34] 65 [19.81] 60 [18.29] 55 [16.76] 55 [16.76] 50 [15.24] 45 [13.72] 40 [12.19] 35 [10.67] 1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 80 [24.38] 75 [22.86] 75 [22.86] 70 [21.34] 70 [21.34] 70 [21.34] 65 [19.81] 65 [19.81] 60 [18.29] NOTES: [ ] Designates Metric Conversions N/ = Application not recommended. Grey =This application is acceptable, but the long line guidelines must be followed. eference Long Line Set section in the I&O www.surecomfort.com 13

efrigerant Line Size Information (con t.) -410A System Capacity Model Vapor Line Connection Size (Inch I.D.) [mm] Vapor Line Size (Inch O.D.) [mm] Vapor Line Selection Chart Capacity Multiplier Table Total Equivalent Length - Feet [m] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [45.72] 150 [45.72] 175 [53.34] 200 [60.96] 225 [68.58] 250 [76.20] 275 [83.82] 300 [91.44] 24 3/4" [19.06] 36 3/4" [19.06] 48 3/4" [19.06] 60 3/4" [19.06] NOTES: N/ = Application not recommended. All calculations assume a 3/8" liquid line 5/8 [15.88] 0.99 1.00 0.97 0.98 0.98 0.96 0.96 0.95 0.94 0.95 0.94 0.93 3/4 [19.05] 1.00 1.00 0.99 0.99 0.98 1.00 0.99 0.99 0.99 0.97 0.98 0.98 7/8 [22.23] 1.01 1.01 1.00 1.00 1.00 0.99 0.99 0.99 0.99 0.99 0.99 0.99 1 [25.4] N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 1-1/8 [28.58] N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 5/8 [15.88] 0.99 0.98 0.97 0.95 0.95 0.93 0.91 0.91 0.90 0.88 0.87 0.86 3/4 [19.05] 1.00 0.99 0.99 0.99 0.98 0.98 0.97 0.97 0.96 0.96 0.95 0.95 7/8 [22.23] 1.01 1.00 1.00 1.00 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99 1 [25.4] 1.01 1.01 1.01 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1-1/8 [28.58] N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 5/8 [15.88] 0.97 0.96 0.93 0.91 0.89 0.88 0.87 0.85 0.83 0.82 0.82 N/ 3/4 [19.05] 0.99 0.98 0.98 0.96 0.96 0.95 0.94 0.94 0.93 0.92 0.92 N/ 7/8 [22.23] 1.00 1.00 0.99 0.99 0.98 0.98 0.98 0.97 0.97 0.96 0.96 N/ 1 [25.4] N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 1-1/8 [28.58] N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 5/8 [15.88] 0.96 0.93 0.91 0.88 0.86 0.84 0.83 0.83 N/ N/ N/ N/ 3/4 [19.05] 0.99 0.97 0.96 0.95 0.94 0.93 0.92 0.91 N/ N/ N/ N/ 7/8 [22.23] 1.00 0.99 0.98 0.98 0.97 0.97 0.96 0.96 N/ N/ N/ N/ 1 [25.4] N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ 1-1/8 [28.58] N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ N/ [ ] Designates Metric Conversions 14 www.surecomfort.com

Performance Data @ AHI Standard Conditions Cooling High Sales Volume Tested Combination (HSVTC) Outdoor Unit Indoor Coil or Air Handler Total Capacity Net Sensible Net Latent Sure Comfort SA17 Air Conditioners SEE EE Indoor CFM [L/s] SA1724AJ2 SH2T2421MEA 24000 [7.0] 17100 [5.0] 6900 [2.0] 17.00 13.00 700 [330.4] 9857595 SA1736AJ2 SH2T3621MEA 36000 [10.6] 26000 [7.6] 10000 [2.9] 17.00 13.00 1050 [495.5] 9857596 SA1748AJ2 SH2T4821MEA 47000 [13.8] 34000 [10.0] 13000 [3.8] 17.00 13.00 1400 [660.7] 9857597 SA1760AJ2 SH2T6024SEA 56000 [16.4] 39300 [11.5] 16700 [4.9] 16.00 12.50 1550 [731.5] 9857610 AHI# S802VA atings Outdoor Unit Furnace Indoor Coil Total Capacity Net Sensible Net Latent SEE EE Indoor CFM [L/s] TCF2417SEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 725 [342.2] 9964694 SA1724AJ2 S802VA050317M TCF2421MEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 725 [342.2] 9964703 TCF3621MEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 725 [342.2] 9964712 TCF2417SEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 675 [318.6] 9964695 SA1724AJ2 S802VA075317M TCF2421MEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 675 [318.6] 9964704 TCF3621MEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 675 [318.6] 9964713 SA1724AJ2 S802VA075317Z TCF2417SEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 725 [342.2] 9964696 SA1724AJ2 S802VA075421M TCF2421MEA 24000 [7.0] 12100 [3.5] 6900 [2.0] 16.50 13.00 825 [389.4] 9964705 TCF3621MEA 24000 [7.0] 12200 [3.6] 6900 [2.0] 17.00 13.00 825 [389.4] 9964714 TCF2417SEA 24000 [7.0] 14700 [4.3] 6900 [2.0] 17.00 13.00 875 [413.0] 9964697 SA1724AJ2 S802VA075421Z TCF2421MEA 24000 [7.0] 14700 [4.3] 6900 [2.0] 17.00 13.00 875 [413.0] 9964706 TCF3621MEA 24000 [7.0] 14800 [4.3] 6900 [2.0] 17.00 13.00 875 [413.0] 9964715 TCF2417SEA 24000 [7.0] 12200 [3.6] 6900 [2.0] 16.50 13.00 825 [389.4] 9964698 SA1724AJ2 S802VA100521M TCF2421MEA 24000 [7.0] 12100 [3.5] 6900 [2.0] 16.50 13.00 825 [389.4] 9964707 TCF3621MEA 24000 [7.0] 12200 [3.6] 6900 [2.0] 17.00 13.00 825 [389.4] 9964716 TCF3617SEA 34200 [10.0] 17600 [5.2] 11000 [3.2] 16.00 12.20 975 [460.1] 9964721 SA1736AJ2 S802VA050317M TCF3621MEA 36000 [10.6] 19200 [5.6] 10000 [2.9] 16.50 13.00 1050 [495.5] 9964732 TCF6021SEA 36000 [10.6] 19700 [5.8] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964746 TCF3617SEA 34800 [10.2] 18300 [5.4] 10600 [3.1] 16.00 12.50 1075 [507.3] 9964722 SA1736AJ2 S802VA075317M TCF3621MEA 36000 [10.6] 19600 [5.7] 10000 [2.9] 17.00 13.00 1075 [507.3] 9964733 TCF6021SEA 36000 [10.6] 20100 [5.9] 10000 [2.9] 17.00 13.00 1075 [507.3] 9964747 SA1736AJ2 S802VA075317Z TCF3617SEA 34800 [10.2] 18300 [5.4] 10800 [3.2] 16.00 12.50 1050 [495.5] 9964723 TCF3621MEA 36000 [10.6] 19600 [5.7] 10000 [2.9] 17.00 13.00 1050 [495.5] 9956422 TCF3621MEA 36000 [10.6] 19600 [5.7] 10000 [2.9] 17.00 13.00 1075 [507.3] 9964734 SA1736AJ2 S802VA075421M TCF6021SEA 36000 [10.6] 19900 [5.8] 10000 [2.9] 17.00 13.00 1075 [507.3] 9964748 TCF6024MEA 36000 [10.6] 20200 [5.9] 10000 [2.9] 17.00 13.00 1075 [507.3] 9964759 TCF3617SEA 34800 [10.2] 18300 [5.4] 10600 [3.1] 16.00 12.50 1075 [507.3] 9964724 SA1736AJ2 S802VA075421Z TCF3621MEA 36000 [10.6] 19600 [5.7] 10000 [2.9] 17.00 13.00 1075 [507.3] 9964735 TCF6021SEA 36000 [10.6] 19900 [5.8] 10000 [2.9] 17.00 13.00 1075 [507.3] 9964749 TCF3617SEA 35800 [10.5] 19000 [5.6] 9900 [2.9] 16.00 12.50 1250 [589.9] 9964725 SA1736AJ2 S802VA100521M TCF3621MEA 36000 [10.6] 19100 [5.6] 10000 [2.9] 17.00 13.00 1025 [483.7] 9964736 TCF6021SEA 36000 [10.6] 19400 [5.7] 10000 [2.9] 17.00 13.00 1025 [483.7] 9964750 TCF6024MEA 36000 [10.6] 19700 [5.8] 10000 [2.9] 17.00 13.00 1025 [483.7] 9964760 TCF3617SEA 34800 [10.2] 18800 [5.5] 10800 [3.2] 16.00 12.50 1050 [495.5] 9964726 SA1736AJ2 S802VA100521Z TCF3621MEA 36000 [10.6] 20100 [5.9] 10000 [2.9] 16.50 13.00 1050 [495.5] 9964737 TCF6021SEA 36000 [10.6] 20700 [6.1] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964751 TCF3621MEA 36000 [10.6] 19600 [5.7] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964738 SA1736AJ2 S802VA125524M TCF6021SEA 36000 [10.6] 20100 [5.9] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964752 TCF6024MEA 36000 [10.6] 20200 [5.9] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964761 AHI# [ ] Designates Metric Conversions www.surecomfort.com 15

Performance Data @ AHI Standard Conditions Cooling (con t.) S802VA atings Outdoor Unit Furnace Indoor Coil Total Capacity Net Sensible Net Latent SEE EE Indoor CFM [L/s] TCF3621MEA 36000 [10.6] 19600 [5.7] 10000 [2.9] 17.00 13.00 1075 [507.3] 9964739 SA1736AJ2 S802VA125524Z TCF6021SEA 36000 [10.6] 19900 [5.8] 10000 [2.9] 17.00 13.00 1075 [507.3] 9964753 TCF6024MEA 36000 [10.6] 20200 [5.9] 10000 [2.9] 17.00 13.00 1075 [507.3] 9964762 SA1748AJ2 S802VA075421M TCF6021SEA 47000 [13.8] 25500 [7.5] 13000 [3.8] 17.00 13.00 1425 [672.5] 9964764 TCF6024MEA 48000 [14.1] 25300 [7.4] 14500 [4.2] 17.00 13.00 1425 [672.5] 9964773 SA1748AJ2 S802VA075421Z TCF6021SEA 47500 [13.9] 26400 [7.7] 12100 [3.5] 17.00 12.50 1550 [731.5] 9964765 SA1748AJ2 S802VA100521M TCF6021SEA 48000 [14.1] 26600 [7.8] 12200 [3.6] 17.00 13.00 1525 [719.7] 9964766 TCF6024MEA 48000 [14.1] 25300 [7.4] 13300 [3.9] 17.00 13.00 1400 [660.7] 9964774 SA1748AJ2 S802VA100521Z TCF6021SEA 47000 [13.8] 25600 [7.5] 13100 [3.8] 17.00 13.00 1400 [660.7] 9964767 SA1748AJ2 S802VA125524M TCF6021SEA 48000 [14.1] 26600 [7.8] 12200 [3.6] 17.00 13.00 1525 [719.7] 9964768 TCF6024MEA 48000 [14.1] 25300 [7.4] 13300 [3.9] 17.00 13.00 1400 [660.7] 9964775 SA1748AJ2 S802VA125524Z TCF6021SEA 47500 [13.9] 25600 [7.5] 12700 [3.7] 17.00 13.00 1450 [684.3] 9964769 TCF6024MEA 48000 [14.1] 25500 [7.5] 14500 [4.2] 17.00 13.00 1400 [660.7] 9964776 SA1760AJ2 S802VA075421M TCF6021SEA 54000 [15.8] 28300 [8.3] 17100 [5.0] 15.50 12.00 1550 [731.5] 9964778 TCF6024MEA 55000 [16.1] 28400 [8.3] 17700 [5.2] 16.00 12.50 1425 [672.5] 9964787 SA1760AJ2 S802VA075421Z TCF6021SEA 54000 [15.8] 28600 [8.4] 16800 [4.9] 15.50 11.70 1600 [755.1] 9964779 SA1760AJ2 S802VA100521M TCF6021SEA 55000 [16.1] 30300 [8.9] 15800 [4.6] 16.00 12.00 1725 [814.1] 9964780 TCF6024MEA 55500 [16.3] 30300 [8.9] 16700 [4.9] 16.00 12.50 1575 [743.3] 9964788 SA1760AJ2 S802VA100521Z TCF6021SEA 54000 [15.8] 28400 [8.3] 17100 [5.0] 15.50 12.00 1550 [731.5] 9964781 SA1760AJ2 S802VA125524M TCF6021SEA 55000 [16.1] 30300 [8.9] 15800 [4.6] 16.00 12.00 1725 [814.1] 9964782 TCF6024MEA 55500 [16.3] 30700 [9.0] 16700 [4.9] 16.00 12.50 1575 [743.3] 9964789 SA1760AJ2 S802VA125524Z TCF6021SEA 54000 [15.8] 28400 [8.3] 17400 [5.1] 15.50 12.00 1525 [719.7] 9964783 TCF6024MEA 55500 [16.3] 30300 [8.9] 16700 [4.9] 16.00 12.00 1575 [743.3] 9964790 AHI# [ ] Designates Metric Conversions 16 www.surecomfort.com

Performance Data @ AHI Standard Conditions Cooling S96VA atings Outdoor Unit Furnace Indoor Coil Total Capacity Net Sensible Sure Comfort SA17 Air Conditioners Net Latent SEE EE Indoor CFM [L/s] TCF2417SEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 675 [318.6] 9964699 SA1724AJ2 S96VA0402317M TCF2421MEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 675 [318.6] 9964708 TCF3621MEA 24000 [7.0] 13900 [4.1] 6900 [2.0] 17.00 13.00 675 [318.6] 9964717 TCF2417SEA 24000 [7.0] 13700 [4.0] 6900 [2.0] 17.00 13.00 700 [330.4] 9964700 SA1724AJ2 S96VA0602317M TCF2421MEA 24000 [7.0] 14100 [4.1] 6900 [2.0] 17.00 13.00 775 [365.8] 9964709 TCF3621MEA 24000 [7.0] 13700 [4.0] 6900 [2.0] 17.00 13.00 700 [330.4] 9964718 TCF2417SEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 700 [330.4] 9964701 SA1724AJ2 S96VA0702317M TCF2421MEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 700 [330.4] 9964710 TCF3621MEA 24000 [7.0] 13800 [4.0] 6900 [2.0] 17.00 13.00 700 [330.4] 9964719 TCF2417SEA 24000 [7.0] 12500 [3.7] 6900 [2.0] 16.50 13.00 825 [389.4] 9964702 SA1724AJ2 S96VA0852521M TCF2421MEA 24000 [7.0] 12500 [3.7] 6900 [2.0] 16.50 13.00 825 [389.4] 9964711 TCF3621MEA 24000 [7.0] 12500 [3.7] 6900 [2.0] 17.00 13.00 825 [389.4] 9964720 SA1736AJ2 S96VA0402317M TCF3617SEA 34200 [10.0] 17200 [5.0] 11100 [3.3] 16.00 12.50 950 [448.4] 9964727 TCF3621MEA 36000 [10.6] 19100 [5.6] 10000 [2.9] 16.50 13.00 1025 [483.7] 9964740 TCF3617SEA 34600 [10.1] 17900 [5.2] 10800 [3.2] 15.50 12.20 1050 [495.5] 9964728 SA1736AJ2 S96VA0602317M TCF3621MEA 36000 [10.6] 19200 [5.6] 10000 [2.9] 16.50 13.00 1050 [495.5] 9964741 TCF6021SEA 36000 [10.6] 19500 [5.7] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964754 TCF3617SEA 34200 [10.0] 17500 [5.1] 11100 [3.3] 16.00 12.50 950 [448.4] 9964729 SA1736AJ2 S96VA0702317M TCF3621MEA 36000 [10.6] 19400 [5.7] 10000 [2.9] 16.50 13.00 1050 [495.5] 9964742 TCF6021SEA 36000 [10.6] 19900 [5.8] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964755 TCF3617SEA 34800 [10.2] 18100 [5.3] 10600 [3.1] 16.00 12.50 1075 [507.3] 9964730 SA1736AJ2 S96VA0852521M TCF3621MEA 36000 [10.6] 19400 [5.7] 10000 [2.9] 16.50 13.00 1075 [507.3] 9964743 TCF6021SEA 36000 [10.6] 19900 [5.8] 10000 [2.9] 17.00 13.00 1075 [507.3] 9964756 TCF3617SEA 34800 [10.2] 18300 [5.4] 10800 [3.2] 16.00 12.50 1050 [495.5] 9964731 SA1736AJ2 S96VA1002521M TCF3621MEA 36000 [10.6] 19600 [5.7] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964744 TCF6021SEA 36000 [10.6] 19900 [5.8] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964757 TCF3621MEA 36000 [10.6] 19400 [5.7] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964745 SA1736AJ2 S96VA1152524M TCF6021SEA 36000 [10.6] 19700 [5.8] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964758 TCF6024MEA 36000 [10.6] 20000 [5.9] 10000 [2.9] 17.00 13.00 1050 [495.5] 9964763 SA1748AJ2 S96VA0852521M TCF6021SEA 47500 [13.9] 26400 [7.7] 12100 [3.5] 17.00 12.50 1550 [731.5] 9964770 SA1748AJ2 S96VA1002521M TCF6021SEA 47500 [13.9] 26500 [7.8] 12100 [3.5] 17.00 12.50 1550 [731.5] 9964771 SA1748AJ2 S96VA1152524M TCF6021SEA 47000 [13.8] 25800 [7.6] 13100 [3.8] 17.00 13.00 1400 [660.7] 9964772 TCF6024MEA 48000 [14.1] 25500 [7.5] 13300 [3.9] 17.00 13.00 1400 [660.7] 9964777 SA1760AJ2 S96VA0852521M TCF6021SEA 53500 [15.7] 27800 [8.1] 17100 [5.0] 15.50 11.70 1550 [731.5] 9964784 SA1760AJ2 S96VA1002521M TCF6021SEA 53000 [15.5] 27400 [8.0] 18200 [5.3] 15.50 12.00 1400 [660.7] 9964785 SA1760AJ2 S96VA1152524M TCF6021SEA 54000 [15.8] 29000 [8.5] 17100 [5.0] 16.00 12.00 1575 [743.3] 9964786 TCF6024MEA 54500 [16.0] 29000 [8.5] 17800 [5.2] 16.00 12.50 1400 [660.7] 9964791 AHI# [ ] Designates Metric Conversions www.surecomfort.com 17

GUIDE SPECIFICATIONS General System Description Outdoor-mounted, air-cooled, split-system air conditioner composite base pan unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller-type condenser fan, suction and legend line service valve, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a coil unit. Quality Assurance Unit will be rated in accordance with the latest edition of AHI Standard 210. Unit will be certified for capacity and efficiency, and listed in the latest AHI directory. Unit construction will comply with latest edition of ANSI/ ASHAE and with NEC. Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-ul-us approval. Unit cabinet will be capable of withstanding ASTM B117 1000- hr salt spray test. Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 550 psig. Unit constructed in ISO9001 approved facility. Delivery, Storage, and Handling Unit will be shipped as single package only and is stored and handled per unit manufacturer s recommendations. Warranty (for inclusion by specifying engineer) U.S. and Canada only. Products Equipment Factory assembled, single piece, air-cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge -410A, and special features required prior to field start-up. Unit Cabinet Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint. All units constructed with louver coil protection and corner post. Louver can be removed by removing one fastener per louver panel. AI-COOLED, SPLIT-SYSTEM AI CONDITIONE SA17 1-1/2 TO 5 NOMINAL TONS Fans Condenser fan will be direct-drive propeller type, discharging air upward. Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. Fan blades will be statically and dynamically balanced. Condenser fan openings will be equipped with coated steel wire safety guards. Compressor Compressor will be hermetically sealed. Compressor will be mounted on rubber vibration isolators. Condenser Coil Condenser coil will be air cooled. Coil will be constructed of aluminum fins mechanically bonded to copper tubes. efrigeration Components efrigeration circuit components will include liquid-line shutoff valve with sweat connections, vapor-line shutoff valve with sweat connections, system charge of -410A refrigerant, and compressor oil. Unit will be equipped with filter drier for -410A refrigerant for field installation. Operating Characteristics The capacity of the unit will meet or exceed Btuh at a suction temperature of F/ C. The power consumption at full load will not exceed kw. Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at conditions of CFM entering air temperature at the evaporator at F/ C wet bulb and F/ C dry bulb, and air entering the unit at F/ C. The system will have a SEE of Btuh/watt or greater at DOE conditions. Electrical equirements Nominal unit electrical characteristics will be v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to v. Nominal unit electrical characteristics will be v, three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to v. Unit electrical power will be single point connection. Control circuit will be 24v. Special Features efer to section of this literature identifying accessories and descriptions for specific features and available enhancements. 18 www.surecomfort.com

GENEAL TEMS OF LIMITED WAANTY* Sure Comfort will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Unit eplacement (egistration equired)...ten (10) Years Parts...Ten (10) Years www.surecomfort.com 19

Sure Comfort P.O. Box 17010, Fort Smith, A 72917 Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. 12/16 QG FOM NO. ASC-223 EV. 1