AKSolutions Data Sheet April 2007 AK882X RF POWER MONITOR. Description: Features:

Similar documents
Carbon Monoxide Transmitter

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

USER MANUAL FOR OPERATING SYSTEM

PTE0705 Electric Fence Monitor

Ethernet General Purpose

HRX Technical Manual. Version 1.2

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Table of Contents SECTION PAGE

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

P2267 NETWORK INTERFACE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Added password for IP setup page : Password must be in IP format!

RS485 MODBUS Module 8AI

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

General Purpose IO Technical Manual

CBI-064. User Manual. Caddx to KNX-BUS Interface

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

wireless. web-based. worthy of the name RACO.

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Long Range Radio Alarm Transmitter

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Mark 25 Ultrapure Water Conductivity Analyzer

Analog Room Pressure Monitor RPC Series

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

Installation and User Instructions

Instruction Manual Model Backup Switch, 1 for 8

Metasys Integrator Airflow Application

HRX3000. Technical Manual

LUDLUM MODEL 52 PORTABLE PORTAL MONITOR. November 2011 Serial No and Succeeding Serial Numbers

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Introduction. OM-THA2

Open Protocol Data Communications

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. DIGITAL CHILLING INCUBATOR MODELS MD5-600, MD5-602, AND MD5-604

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Metasys Integrator Vilter Application

FlameGard 5 UV/IR HART

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

PERMACONN PM1030 Includes DI300. Installation Manual

Frequently asked questions: Intelligent Transmitter Series

PBI Manual. Paradox to KNX-BUS Interface

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Long Range Radio Alarm Transmitter

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

Metasys Integrator TITUS Application

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

Product Manual SZ1144

20 Light Remote Annunciator

FlameGard 5 MSIR HART

ECO N DATE DESCRIPTION OF CHANGE CHG

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Product Manual SZ1145

IF-L/RF Protection Switch

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

WeatherLink for Alarm Output Addendum

REPEATER FS5200R INSTRUCTION MANUAL

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

UNC100 Integra Manual

DTSX200 Communications(Modbus) Guide

DT6500 CONTROLLER. for the ICD PART #: ICD SERIAL #: 1714

User s Guide. CN616 Series 1 4 DIN Economical 6-Zone PID Temperature Controllers. Shop online at omega.com SM

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

21-light Remote Annunciator. Owner s Manual

Independent Zone Control (I.Z.C.)

OVEN INDUSTRIES, INC.

LineGuard 2300 Program User Manual (FloBoss 107)

WM3000 WIRELESS MODULES

Sierra Series 900 Single & Dual Channel System. Instruction Manual

MAMI MULTI BASE STATION

Manual GPRS Data Logger PCE-GPRS 2

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual

User Manual. Dryer Controller M720

Modbus TCP/IP Option Instruction Manual

SyringeHeater.com. Syringe Heater. Thermo-Kinetic Heat Clamping. Model: HEATER-KIT-1LG HEATER-KIT-5SP

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Across-the-Line SERIES MP300 Combined Manual and Automatic

Metasys Integrator Compu-Aire Application

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

Dryer Controller M720

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

EL-OEM-3 OEM Packaged Voltage Data Logger

Wireless Door Alarm System. Installation and Operation Manual

FieldServer Driver - Serial FS Notifier NCA

COCB_ Circuit Breaker (2 state inputs/ 2 control inputs)

Soft Start Series MP700 Solid State, Reduced Voltage

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Fratech Multipath-IP

600 Range Dialer Installation Manual. Version 1.0

Transcription:

AK882X RF POWER MONITOR Features:. > Operates from 9-30VDC power input > Installs inline to simplify mounting > Bidirectional sensor automatically detects forward and reflected power, and calculates VSWR > Small size just 3.8 x3.1 x.1.2. > Very low power less than 1W max > Form-C alarm output contacts C, NO and NC Applications: Paging Systems SMR/Trunked Radio Systems Backup Controller Failure Notification > Backlit, easy to read LCD displays power, VSWR, and alarm status > Simple, intuitive setup stores user-set limits in non-volatile memory > Serial RS485 channel allows multidrop and remote access Description: The AK882X series of monitors are low power microprocessor controlled RF power meters designed to detect or predict equipment failures by monitoring transmit power. The unit calculates VSWR from measured forward and reflected power, and generates alams if outside if user-set limits. The monitor can also alarm on periods of continuous activity (stuck-key) or on no activity, identifying dead transmitters. Setup is simple and intuitive the monitor steps through each setup parameter and stores the desired limit value in non-volatile memory. If a limit is exceeded for more than a user-set delay period the alarm relay will be activated. Alarm delay is adjustable from 0.1 seconds to 10 seconds, helping to eliminate false alarms due to transient conditions. Automatic alarm reset can also be adjusted up to twenty-four hours, but the original cause of the alarm is still stored for later retrieval. The backlit LCD display shows forward and reflected power, VSWR, and monitor status. Front panel buttons are used to adjust setup parameters and clear alarms. A serial RS485 channel is available for remote access to all setup and status functions. Sample VB code is available from AKSolutions. Page 1

Power Supply Voltage Absolute Maximum Ratings: 42VDC RF Power FWD 2X Power Range* Power Supply Current 0.1A RF Power REFL <= FWD Operating Temperature -20C to +70C Storage Temperature -55C to +85C Alarm Relay Current 2.0A @ 60VDC *1KW for 1000 models * Specifications: * PARAMETER MIN TYPICAL MAX UNITS NOTES Input Voltage 9 30 Volts DC Input Current 0.1 Amps Dependent on input voltage Input Power (DC) Relay Off.5 Watts Relay On 1 Watts Operating Temparature -20 +60 DegC LCD readability limitation Storage Temperature -40 +85 DegC RF Power Range -100 Models 0 100 Watts -350 Models 0 350 Watts -1000 Models 0 1000* Watts Peak, 750W average RF Power Resolution -100 Models.025.25 Watts Decreases at higher power levels -350 Models.05.75 Watts Decreases at higher power levels -1000 Models.15 1.5 Watts Decreases at higher power levels RF Frequency Range AK8822- Models 406 1000 MHz AK8825- Models 100 325 MHz AK8828- Models 30 80 MHz VSWR Range 1.0:1 25.5:1 Accuracy 1% After Site Calibration Alarm Relay Current 0 1 Amp Weight 1 LB Connectors RF N Type One male, one female Power & Alarm 8-POS Depluggable terminal block Current Version 7.1 Firmware & Hardware Version Page 2

Operation The AK882X-XXX series of RF power monitors combine RF power sensing, display, monitoring and remote access into one compact package. User-set parameters allow a wide range of configuration without complicated setup procedures. The monitor requires a DC power supply and will draw approximately 50-100mA at 12VDC. If station power is unavailable a 12-volt transistor radio battery eliminator or any DC source from 9-30 volts can be used. Upon installation both forward and reflected power must be calibrated. Connect an inline wattmeter in series with the monitor. The calibration trimmers are located on top of the alarm monitor. With RF power applied, and the wattmeter set to display forward power, adjust trim pot closest to the RF power source (transmitter or combiner) until the display matches the wattmeter. Set the wattmeter to display reflected power and adjust the opposite trimmer to match the reflected power reading. This procedure should be performed before setting alarm parameters. Please note that the monitor can be installed in either direction in the RF line. The monitor will always assume that the higher power level is forward regardless of which way the unit is installed. Setup Setting up the monitor can be accomplished either through the front panel or remotely through the RS485 serial port. Please note that remote programming requires an RS485 level translator and software on a host computer (see Section Serial Communications). Local Setup (Data Menus) The data and parameter displays are arranged in a sequential pattern: -> FWD VSWR REFL ;main display ^ Alarms ;HhLlSsKU ^ Enable Threshold ;threshold for measurement ^ Low Pwr Lim xxx.x watts ;low power limit ^ High Pwr Lim xxx.x watts ;high power limit ^ SWR Lim x.x ;SWR limit ^ Keyed Max xxxxx minutes ;maximum keyed timer ^ Unkey Max xxxxx minutes ;maximum unkeyed timer ^ Alm Delay x.x secs ;alarm verification delay ^ Alm Reset xx.xx ;auto alarm reset time ^ Output Type Nx ;alarm output NO/NC ^ Slave Address xx ;serial data address ^ Key Time xxx.xx.xx ;transmitter key time ^ Unkey Time xxx.xx.xx ;transmitter unkey time <- --Defaults-- ;restore factory setups <- Defaults Set ; factory setups restored Each press of the SELect button will advance the display to the next menu item, eventually returning to the main display. If the unit is left on a setup display for more than five minutes without a key press the display will automatically return to the main display. All monitoring functions continue regardless of the display selection. Page 3

Main Display This shows current values for forward and reflected power, and calculated VSWR. In order to retain the bidirectional use of the sensor the electronics will always assume that the greater power value is forward, allowing the monitor to be installed in either direction. Forward power will appear on the display in the left-most position, reflected power in the right most, and VSWR in the center. All power readings are in watts. Also, alarms are indicated on the display by asterisks, with power-related alarms indicated on the left and SWR alarms indicated on the right. UP and DowN buttons to change to the desired value. Alarms will be generated whenever forward drops below this value for a continuous period equal to or greater than the alarm delay period (see below). High Power Limit To adjust the high power alarm trip point, use the UP and DowN buttons to change to the desired value. Alarms will be generated whenever forward rises above this value for a continuous period equal to or greater than the alarm delay period (see below). Alarms This shows current and stored alarm types. An active low power alarm (in an alarm condition now) is shown by a capital letter L, whereas a previous low power alarm is indicated by a lower case l. Similarly, high power alarms are indicated by H or h, and SWR alarms are shown by S or s. K and U represent Key and Unkey time limit alarms respectively. Pressing the RESet button will clear any active or stored alarms (if the alarm condition still exists it will re-appear after the alarm delay). Enable Threshold In order to determine the keyed or unkeyed status of the transmitter the monitor first checks to see if any RF power is present. This function determines the level at which the monitor can assume that the transmitter is keyed, and when to enable VSWR and power monitoring. Note: For all setup functions the up/down buttons can be held down and after approximately one second will change at a faster rate. Low Power Limit To adjust the low power alarm trip point, use the SWR Limit Use the UP and DowN buttons to adjust the maximum allowable VSWR limit. This can be from 1.1:1 to 9.9:1. Keyed Time Limit This sets the time, in minutes, that the transmitter can remained keyed continuously before generating an alarm. Range is 0 to 9999 minutes. Setting 0 disables this alarm. Unkeyed Time Limit This sets the time, in minutes, that the transmitter can remained unkeyed continuously before generating an alarm. Range is 0 to 9999 minutes. Setting 0 disables this alarm. Alarm Delay This parameter can be adjusted from 0.1 second to 10.0 seconds. Any time that the electronics detects an alarm condition (power or VSWR) an alarm timer begins counting down. If the alarm condition persists continuously for the alarm delay period then an actual alarm will be generated and indicated on the display and output. This can be used to eliminate false alarms caused by noise or Page 4

transient conditions. Alarm Reset Time This value determines how long the monitor will wait after the last valid alarm detection before automatically resetting the alarm output. This can be set in hour increments from 0 to 255 hours. Note that if an alarm recurs before the auto-reset timeout the reset delay will be restarted from that occurrence. Auto-reset will not clear the display alarm indicators (only the output) so that service personnel can see what caused the alarm. Relay Type This defines the alarm output relay to be normally off (NO) or normally on (NC) during a no-alarm condition. The output will complement if an alarm is present. Please note that if it is set to Normally On then the physical relay output pin operation will be reversed. When programmed to the Normally On state this function causes an alarm to be generated for a DC power failure, since the relay will turn off. Slave Address The monitor is capable of remote setup and reporting through an RS485 serial connection. This requires each monitor on the serial connection to have a specific address for polling. This can be set from 1 to 32, thus up to 32 devices can be monitored in parallel. Please note that the serial port baud rate is fixed at 9600/N/8/1. See Section Serial Communications for additional information. Key Time Any time RF power is measured at or above the enable threshold value (see above) the unit assumes transmitter key and increments the key time accumulator. This value is in hours:minutes:seconds format. Total time accumulation is 9999:59:59, or about 416 days. Unkey Time Whenever RF power is measured below the enable threshold the unkey time accumulator is incremented. To clear both key and unkey times press and hold both the UP and DowN buttons simultaneously while displaying unkey time. This value is in hours:minutes:seconds format. Total time accumulation is 9999:59:59, or about 416 days. Restore Defaults This restores all limits and delays to their original factory settings and clears both key and unkey timers. To activate, press both the UP and DowN buttons simultaneously while showing the -- Restore Defaults display. If selected, the display will change to Defaults Set. Alarm Reset Pressing the alarm RESet button at any time will clear all current and stored alarms and indicators, and de-activate the alarm output relay. If an alarm condition still exists the alarm will re-occur after the alarm delay period. Miscellaneous All setup values and key/unkey times are stored in non-volatile memory so that information is preserved even when power is disconnected. This data is saved whenever the SELect button is pressed, and key/unkey timers saved every 15 minutes during operation. To assure that the latest key/unkey times are saved press the SELect button once before disconnecting power. Page 5

Application Examples Please note: if used following a combiner, for best IM performance the monitor should be installed between the combiner and duplexer. Generally the duplexer has minimal effect on the antenna reflected power. Set the alarm delay to.5 sec or as appropriate. This value should be short enough to catch alarms within a reasonable amount of time but long enough to eliminate false alarms due to transient conditions (key-up glitches, power ramping, etc.). To monitor the output of a paging transmitter: Set the enable threshold to something less than the lowest normal transmitter output power but greater than zero. This will enable the unit for monitoring. In some high-density sites the antenna can pick up several watts from adjacent antennas, so the enable threshold should be just high enough to eliminate false key indications. Set the low and high power alarm limits Set the low power limit to something less than the normal output power of a the transmitter and above the enable threshold. If desired, setting it to zero (or below the enable threshold) effectively disables the low power monitoring. The high power limit will need to be set above the highest normal power level with the transmitter keyed. Setting it to max will effectively disable high power alarming. Set the VSWR limit to 1.5:1 or as appropriate. This defines the maximum allowable SWR limit for a properly functioning antenna. Set the alarm reset interval to 24 hours or as appropriate. This should be set to whatever is convenient for automatically resetting the alarm output relay. This interval will be extended, however, as long as an alarm condition actively persists. Set output type to NO or as appropriate Setting normally open will make the relay turn on during an alarm condition. In this case, the physical NO-NC connections will be per the physical pinout description. Set the slave address as appropriate, or ignore if serial access is not required. Note: Key and Unkey times are reference only and can only be cleared. All of this will have the effect of providing an alarm indication if the antenna VSWR goes above the programmed limit, or if power goes outside the programmed limits. Page 6

To monitor the transmitter in a continuously keyed microwave link: Set the enable threshold to zero. This will enable the AK882X for continuous monitoring. Assuming a normal transmit power of 100 watts: Set the low power limit to 50 watts (or as desired) Set the high power limit to 150 watts (or as desired) Set the slave address as appropriate, or ignore if serial access is not required All of this will have the effect of holding the relay on whenever the transmitter is keyed and operating within the power window defined by the low and high power limits, and the antenna system is at or below the allowable VSWR. If the transmitter unkeys or otherwise drops below the low power limit, or if it goes above the high power limit, or if the VSWR goes above the VSWR limit, or if DC power fails, the alarm relay will change to the alarm state. This defines the window for normal transmitter operation. Set the VSWR limit to 1.5:1 or as appropriate. This defines the maximum allowable SWR limit for a properly functioning antenna. Set the alarm delay to.1 sec or as appropriate. If you are trying to follow real-time conditions, set up the minimum delay time. Set the alarm reset interval to min (0). Again, if this will be following real-time conditions this will allow the output to operate in non-latched mode. Set output type to NC or as appropriate Setting normally closed will make the relay turn on during normal operation. In this case, the physical NO-NC connections will be reversed. This allows an alarm to be generated both for monitored limits and for a DC power loss. Page 7

Serial Communications Interface The power monitor is capable of remote setup and alarm reporting through an RS485 2-wire serial interface. This is not a PC compatible interface directly, and damage can occur if connected to a PC serial port. It is possible to communicate wit a PC or other device using a RS232 to RS485 adapter. With an adapter it is possible to exercise the serial channel using Windows HyperTerminal. The RS485 channel within the monitor can be paralleled to connect up to 32 devices. Future development will bring AKSolutions standard equipment to provide remote access via Ethernet, wireless, and PSTN. Command Format All monitors act as slaves only; no unit will send on the RS485 line unless properly (by address) commanded to by a master device. In general the command format is as follows: $aac[m][dd...d]cs<cr> where $ = SOT aa = slave address C = Command [m] = command modifier [dd...d] = data CS = 2 digit ascii hex checksum <cr> = carriage return (0x0d) The communications interface is fixed at 9600 baud, no parity, 8 data bits, and 1 stop bit. For proper operation in a multi-dropped system each unit must be assigned a specific slave address (see Setup Section 1). To connect multiple devices parallel the wiring from each unit (RS485+ to RS485+, RS485- to RS485-). An additional ground has been provided for connecting a shield to minimize noise interference. To ease development the units will accept double question marks (?? ) in place of the calculated checksum. Checksum is normally the lowest 8 bits of a simple addition of each byte in the packet, sent as ascii hexadecimal. For illustration purposes address 01 is assumed in the following command listing: Command Definition Response Definition $01SS??<cr> Send Status (short) <LHSRKU>??<cr> $01SL??<cr> Send Status (long) <*fffff-rrrrr-sssss-lhsr??<cr> An alarm is indicated by the presense of it's corresponding letter: L-Low Power, H-High Power, S-SWR, R- Relay active, K-Keyed time exceeded, U- Unkeyed time exceeded. Where * indicates keyed, fffff = forward power, rrrrr = reflected power, sssss = swr, LHSR same as short status Page 8

$01I??<cr> Send Info <xxxxx-yyyyy-kuphr-kupmnkupse-unkhr-unkmnunkse>??<cr> Where xxxxx = a/d input 0 val, yyyyy = a/d input 1 val, kuphr = key time hours, kupmn = key time minutes, kupse = key time seconds, unkhr = unkey time hours, unkmn = unkey time minutes, unkse = unkey time seconds $01T??<cr> Send Type <SA7.1??>??<cr> Monitor version 7.1 $01DY??<cr> Restore Defaults Ack (<Y><cr>) or Nack (<N><cr>) success or fail $01KC??<cr> Clear Key timers Ack (<Y><cr>) or Nack (<N><cr>) success or fail $01AC??<cr> Clear Alarms Ack (<Y><cr>) or Nack (<N><cr>) success or fail $01PnR??<cr>** Read setup for n see separate definition Current value of parameter n below parameter n $01PnWdd d??<cr> Write setup parameter n for n see separate definition below Repeat new value of parameter n **Parameters are read or set using the following definition for n: Meaning: Low power limit is set to 25.0 watts. 1 Relay NO (00000) or NC (00001) 2 Threshold value (ddddd) x10 power 3 Low Limit (ddddd) x10 power 4 High Limit (ddddd) x10 power 5 SWR Limit (ddddd) x10 value 6 Alm Delay (ddddd) x10 seconds 7 Alm Reset (ddddd) hours 8 Model text (*write is factory use only) 9 Description text a Max TX Key Time (ddddd) minutes b Max TX Unkey Time (ddddd) minutes Command String Examples Write new value for low power limit: Command: $01T3W00250??<cr> Response: <00250>??<cr> Read monitor status (long): Command: $01SL??<cr> Response: <*00703-00011-00013-S>??<cr> Meaning: Transmitter is keyed Fwd Power = 70.3 watts Refl power = 1.3 watts SWR = 1.3:1 SWR alarm is active Write description text Command: $01P9WUser-set text field for general use??<cr> Response: <User-set text field for general use>??<cr> Page 9

Dimensions & Mounting: * Electrical: * Pin one of the terminal block is on the left side when viewed from the front. Pin functions are as follows: PIN 1 Pin Function 1 DC Power in, 9-30VDC 2 Ground 3 RS485+ 4 Ground 5 RS485-6 Relay NC 7 Relay C 8 Relay NO Ordering Info Model Frequency Power Range AK8822-100 406-1000 MHz 0-100W AK8822-350 406-1000 MHz 0-350W AK8822-1000 406-1000 MHz 0-1000W AK8825-100 100-325 MHz 0-100W AK8825-350 100-325 MHz 0-350W AK8825-1000 100-325 MHz 0-1000W Page 10