MicroCoat Flow Guard. MC480M Series. Operating Manual. IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors

Similar documents
MicroCoat Flow Guard Operating Manual

Premium Desoldering station with Electric Pump Ref. DIS-D

TECHNICAL PRODUCT DATASHEET

Ultimus I II High Precision Fluid Dispensers

Hot Air Station without Extractor desk Ref. JTSE-QA

Q-SERIES DI WATER HEATER

Living Space Sensor Touchscreen Covers SXWSCDXSELXX (Touchscreen Display) SXWSCDPSELXX (Touchscreen Display with Occupancy Sensor)

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

Wideband Optical Couplers

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

YVP110 Advanced Valve Positioner. Please use the attached sheets for the pages listed below in the following manuals. IM 21B04C01-01E (10th)

EJX / EJA-E series. For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2.

Model 685B1001A10. Electronic Vibration Switch. Installation and Operating Manual

ETH1000-MKII. User manual

MultiTemp IV Thermostatic Circulator

Dual SDI Optical to Electrical Converter

Static Pressure Control

ETH1000-D. User manual

Operating Instructions

Owner & Operator s Manual. Table of Contents

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model)

2-Port alarmcharge Hub - Manual

RATIO:GUARD Model E-1S EC Monitor

Safety Enclosure for Automated Dispensing Systems

Micro800 Programmable Controller External AC Power Supply

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Model OP155 Air Dryer

PROCESSING UNIT II V Hz V Hz. Table of Contents

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Tokyo Gas Engineering Solutions Corporation

2 WOW MOP COMPONENTS. Spray Button Power Button Nozzle. Pad Attach (Shadowed Area) Handle. Reservoir. Base

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

Manual DRUM-HEATER DH27

DEMA 830 Laundry Master TM Installation Instructions

Beacon 800 Gas Monitor Operator s Manual

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Operator s Manual. The Quietek

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

Instruction Manual. Bucket Oil Pump

DEB71. Earth Leakage Monitoring Relay. Benefits. Description


1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Installation Manual Premier Elite IXP-W


Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

Premier External TD. Installation Manual INS352-3

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

M7100 Pressure Transducer

Digital Heat Block User Manual

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

flexibility programmed settings.

Cable Actuated Sensor Industrial User Scalable VDC Output

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

DEMA TITAN EP II WAREWASH CONTROL TE.812 & TE.813 SERIES

JDDT1 - Single Stage Digital Thermostat

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Protocol Station Remote Alarm

D3000. Installation & Setup Guide

Cable Actuated Sensor Industrial User Scalable 4 20mA

EXC-450 User s Manual

User Manual. Juice Extractor MODEL: WJE2BSLA

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

SAFETY INFORMATION AND WARNINGS

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

KM300 Carbon Monoxide Detection System Installation Manual

Installation and Owner Man u al

User Manual. OCTAVIUS Detector 729 (T10040) and Detector Interface 4000 (T16039)

STATUS ALARM HISTORY ALARM RESET

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

Heater Installation Kit

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

Reacti-Therm I and III Heating/Stirring Modules

Instruction Manual and Warranty

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

SF100 User Manual Version 1.0

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

CA5000 Liquid CO 2 Freezer Backup System

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

DEMA 832 LAUNDRY MASTER TM INSTALLATION INSTRUCTIONS

Pump-Down Controller MODEL 4052

Instruction Manual Model L2 RF Switch

! "! # Please read these installation and operating instructions completely and carefully before starting.

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

ELECTRIC FIREPLACE OWNER S MANUAL

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

Transcription:

MicroCoat Flow Guard Operating Manual MC480M Series IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors Electronic pdf files of EFD manuals are also available at www.nordsonefd.com

Contents Introduction...3 Specifications...4 Features...5 MC800 System Assembly...6-7 Priming the System...7 System Diagram...8-9 MC4000 System Assembly...10 MC2000 System Assembly...10 Setup...11-13 Making Flow Adjustments...14 Operation...15 Preventive Maintenance...16 Troubleshooting Guide...17 Replacement Part Numbers...18-19 Warranty...Back Cover 2

Introduction The purpose of the Flow Guard system is to signal a high or low flow condition. The MC480M operates on the calorimetric principle. As lubricant flows over the tip of the sensor, it removes thermal energy from the sensor. The amount of power required to maintain the temperature of the sensor is proportional to fluid flow. Coupled with the sensor is a controller that provides a logic interface between the sensor output and the stamping/forming press. The MC480M system provides an alarm signal when lubricant flow varies enough to cross either the low flow or high flow set points. The signal is typically connected to an E-Stop circuit to shut the press down when an alarm condition is present. The set points are determined empirically and are based on an acceptable range of flow determined by the user. The MC480M Flow Guard system is designed to work together with the MicroCoat lubrication system. Control pressure used to operate the MicroCoat System also provides press status input to the MC480M. Upon initiation of control air: 1. The MicroCoat system valves open and lubricant begins to flow. 2. The MC480M alarm system becomes active and a 30-second delay period commences while the sensor completes a start-up sequence. 3. The sensor s green LED settles between the upper and lower control switch points indicating the flow is recognized and being monitored. When flow exceeds an alarm set point: 1. The MC480M stops press operation through the press E-Stop circuit. 2. The system control air is turned off. 3. The alarm indicator illuminates. Once the error condition is corrected, the press is restarted resuming control pressure and flow monitoring. 3

Specifications MC480 Controller Size: 11.9 W x 19.1 H x 8.9 D cm (4.7" x 7.5" x 3.5") Weight: 1.45 kg (3.20 lb) Input voltage: MC480M-120: 120 VAC, 50/60 Hz, 10.4/8.7 VA MC480M-220: 220 VAC, 50/60 Hz, 9.0/8.0 VA Resistive: 0.4A @ 125 VAC, 2.0A @ 30 VDC Inductive: 0.2A @ 125 VAC, 1.0A @ 30 VDC Maximum current: 3.0A Maximum voltage: 250 VAC, 220 VDC Minimum air pressure: 40 psi (2.76 bar) Protection: IP67 MC480-FS Flow Sensor Size: 4.1 W x 10.9 H x 7.1 D cm (1.6" x 4.3" x 2.8") Weight: 0.47 kg (1.03 lb) Operating voltage: 20-36 VDC Current rating: 2 x 125mA, short-circuit protection Reverse polarity protection/overload protection Temperature range: -25 C to 80 C (-13 F to 176 F) Protection: IP67 Sensor material: Type 316 stainless steel Meets CE standards NOTE: Specifications and technical details are subject to engineering changes without prior notification. 4 RoHS 标准相关声明 (China RoHS Hazardous Material Declaration) 产品名称 Part Name 有害物质及元素 Toxic or Hazardous Substances and Elements 铅 汞 镉 六价铬 多溴联苯 多溴联苯醚 Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Chromium Biphenyls Diphenyl Ethers (Pb) (Hg) (Cd) (Cr6) (PBB) (PBDE) 金属转接头 X O O O O O All Brass Fittings O: 表示该产品所含有的危险成分或有害物质含量依照 EIP-A, EIP-B, EIP-C 的标准低于 SJ/T11363-2006 限定要求 Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is below the limit requirement in SJ/T11363-2006. X: 表示该产品所含有的危险成分或有害物质含量依照 EIP-A, EIP-B, EIP-C 的标准高于 SJ/T11363-2006 限定要求. Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is above the limit requirement in SJ/T11363-2006.

Features 1. Power Switch Turns the system on and off. Controller 2. Alarm Delay Switch Starts a 3-minute delay that prevents press shutdown when setting new oil flow rate. Push and hold for 3 seconds to cancel alarm. 3. Alarm Indicator Illuminates when improper flow is detected blinks in override mode. 4. AC Power Flow Guard Power Alarm Delay Alarm Relay AC Line Power Flow Sensor Model No. MC480 Serial No. 5. E-Stop Circuit Connection 6. Control Air Input Activates the system when control air is supplied. Minimum 40 psi (2.76 bar) required. Flow Sensor 7. Flow Sensor Connector 8. Fuse 9. Setting Buttons for Adjustment and Configuration 10. Operation Display Green LEDs indicate the current flow (the LEDs 0-9 represent the range between no flow and maximum flow) Two LEDs indicate the position of the switch points (orange = output closed, red = output open). 5

System Assembly MC800 1. Install the flow sensor with adapter at the MCFILTER outlet using the supplied fittings. The bar graph side of the unit should face the downstream flow direction. 2. Find a suitable location where ambient temperature is fairly constant, then securely mount the controller and flow sensor. The MicroCoat stand is an ideal location if used. Flow direction Flow sensor 1 2 Controller Filter 3. Connect the MC480M E-Stop circuit wire to the MicroCoat E-Stop circuit. 4. Refer to the schematic and connect the controller power cord to an appropriate source. Connects in series with the Black E-Stop wire from the MicroCoat controller 4! Caution! Risk of electric shock Warning! Disconnect power before removing cover AC Line Power L1 1 L2 2 GND GRN/YEL IMPORTANT: Electrical connections must be made by a licensed electrician. 6

5. Install the supplied tee fitting onto the MicroCoat control air coupling, and connect the grey hose from the air tee on the controller to the input on the Flow Guard controller. 6. Secure the connecting cable to the flow sensor. To Control Air 5 To E-Stop Circuit 6 To Fluid Inlet Priming the System IMPORTANT: The system must be primed free of air for proper performance. Refer to the System Setup instructions in the MC800 MicroCoat System manual for detailed explanation on priming the system. 7

System Diagram Lubricant (clear hose) Operating Air Fluid sensor connection 8

9

System Assembly MC4000 A. Refer to the figure to the right for installation assistance. Follow steps 1 through 4 on MC800 System assembly instructions (page 6). B. Install the supplied tee fitting onto the MicroCoat control air coupling and connect the grey hose from the air tee on the controller to the input on the Flow Guard controller. C. Secure the connecting cable to the flow sensor. To E-Stop Circuit To 1 Control Air To Fluid Inlet System Assembly MC2000 A. Refer to the figure to the right and remove the pipe plugs from ports and. B. Install the flow sensor with adapter into the rear hole of the MC2000. The bar graph side of the sensor should face towards the front of the MC2000. 2 1 C. Install the special fitting with O-ring into the side port of the MC2000 and tighten. D. Using the fittings and tubing supplied, connect the side port to the inlet of the flow sensor as shown. 10 NOTE: Complete the MC2000 assembly using steps 4 through 6 on pages 6 and 7.

Set-up and settings for water (For media other than water 7.1: Low flow adjustment). Switch on the supply voltage. All LEDs light and go out again step by step. During this time the outputs are closed (if configured as normally open). The unit is in the operating mode. Let the normal flow circulate in the installation. Check the display and determine further actions. The factory setting is suitable for the application. Adapt the switch points to your application if necessary ( 6.2, 6.3). Your normal flow is below the representation range of the display. Carry out high flow adjustment ( 6.1). Adapt the switch points to your application if necessary ( 6.2, 6.3). Your normal flow exceeds the representation range of the display (LED 9 flashes). Carry out high flow adjustment ( 6.1). Adapt the switch points to your application if necessary ( 6.2, 6.3). You can restore the factory setting any time. ( 7.3). High flow adjustment (optional) The unit determines the existing flow as normal flow and adapts the display representation (all LEDs except the switch point LEDs light green). Let the normal flow circulate in the installation. Press the pushbutton and keep it pressed. > LED 9 lights, after approx. 5 s it flashes. Release the pushbutton. The unit is now adapted to your flow conditions. It passes into the operating mode, the display should now show example 1. NOTE: The adjustment affects the switch points: They are increased proportionally. 11

Change switch point SP1 Briefly press the pushbutton. > The SP1-LED flashes red, the SP2-LED lights red. Press the pushbutton or as often as required. Each press of the pushbutton shifts the LED by one position in the indicated direction. NOTE: If no pushbutton is pressed for 2 s, the unit returns to the operating mode with the newly set value. Change switch point SP2 Briefly press the pushbutton. > The SP2-LED flashes red, the SP1-LED lights red. Press the pushbutton or as often as required. Each press of the pushbutton shifts the LED by one position in the indicated direction. NOTE: If no pushbutton is pressed for 2 s, the unit returns to the operating mode with the newly set value. Additional settings (optional) Low flow adjustment If the unit is used in media other than water, you should additionally adapt the unit to the minimum flow. NOTE: The following adjustment must only be carried out after the high flow adjustment. Let the minimum flow circulate in the installation or ensure flow standstill. Press the pushbutton and keep it pressed. > LED 0 lights, after approx. 5 s it flashes. Release the pushbutton. The unit adopts the new value and passes into the operating mode. 12

Configure the switching outputs The unit is delivered as normally open. In case of need you can change the outputs to normally closed (the changing applies to both outputs): Press the pushbutton for at least 15 s. > LED 0 lights, after approx. 5 s it flashes. > After 10 s the current setting is displayed: LEDs 5...9 light orange (= outputs normally open). > After approx. 15 s LEDs 0...4 flash orange. Release the pushbutton. The outputs are changed to normally closed operation. For a new changeover repeat the operation. Restore the factory setting (reset) Press the pushbutton for at least 15 s. > LED 9 lights, after approx. 5 s it flashes. > After approx. 15 s LEDs 0...9 flash orange. Release the pushbutton. All settings are reset to the factory setting: - operating area: 5...100 cm/s for water - switch point SP1: LED 2 / switch point SP2: LED 7 - output function: NO - unlocked. Lock / unlock the unit The unit can be locked electronically to prevent unintentional settings. Press both setting pushbuttons simultaneously for at least 10 s in the operating mode. > The indication goes out, the unit locks or unlocks. On delivery: unlocked. 13

Making Flow Adjustment Making an adjustment to the flow volume may cause the flow sensor to cross the preset alarm set points. To avoid triggering the E-Stop circuit, the MC480M is equipped with an alarm delay. Initiating this delay provides three minutes to reset the flow and reprogram the sensor. 1. Push the Alarm Delay switch on the controller to initiate the 3-minute delay. The alarm indicator will begin to flash. NOTE: If more time is required, pushing the switch again will restart the 3-minute delay. 2. Establish the new flow setting for the MicroCoat System. 3. Program the sensor as instructed on page 11. 4. Push and hold the Alarm Delay switch for 3 seconds to cancel the delay or just allow the time to run out. The alarm indicator will stop flashing. NOTE: Switch points are factory set to LEDs #2 and #7. These settings should be right for most applications. If you require more or less sensitivity, follow the procedure on page 13 to change the switch points. 14

Operation After every power on all LEDs light and go out again step by step (during this time the outputs are closed if configured as normally open). The unit is then ready for operation. In case of power failure or interruption all settings remain. Operating indicators Green LED bar: Current flow within the representation range. Indication of the switch points (SP1 / SP2): - LED orange: output closed. - LED red: output open. LED 9 flashes: current flow above the representation range. LED 0 flashes: current flow far below the representation range. Interference indicators Short circuit at the switching output S1. The operating indicator and 5 red LEDs on the left hand light alternately. If the short circuit has been rectified, the unit immediately passes into the normal operating state. The current operating state is displayed. Short circuit at the switching output S2. The operating indicator and 5 red LEDs on the right hand light alternately. If the short circuit has been rectified, the unit immediately passes into the normal operating state. The current operating state is displayed. Display OFF (no LED lights): Operating voltage too low (< 19 V) or failed. Ensure a correct voltage supply. 15

Preventive Maintenance The MC480M is designed for long life with minimal maintenance. CAUTION: Before performing any maintenance, set the system pressure to the OFF position and disconnect power. Check the sensor tip after the first month of operation to establish an appropriate cleaning schedule. Clean the sensor probe periodically. 16

Troubleshooting Guide Unstable oil flow causes unit to switch off. Unstable oil flow can be caused by air pressure fluctuations. Make sure the MicroCoat system pressure is stable. The lubricant system may have entrapped air. This air, when it reaches a flow control, can cause a flow surge from the valve. System trips off and indicates an underflow condition even though there is no air pressure fluctuation or air in the lubricant system. Reset the minimum flow level by turning the MicroCoat system off, then push the Learn/Set button and hold until LEDs light step by step from left to right, then step by step from right to left. The low switch point will now be 20% above zero flow. The low switch is slow to respond to an underflow condition. The low switch point can be moved closer to the center of the bar graph. The low switch point is factory set at #2. Changing the setting to #3 will provide a faster response time. Refer to page 13 for this procedure. Sensor is very unstable. Sometimes switching off low and at other times high. Check the sensor probe for contamination and clean if necessary. Check the sensor location. The bar graph display must face downstream. Check to make sure the sensor is installed fully into the adapter. The sensor must be located in an area that is away from air currents that can cause temperature changes. If necessary, wrap the sensor adapter with an insulating blanket. 17

Replacement Part Numbers 1. 8126-W Tubing - 6 mm OD, urethane, white 2. 4070 Sensor to adapter coupler 3. 4069 Low flow adapter 4. 480FS Flow sensor assembly 5. 2024-6mm Tubing - 6 mm OD, urethane, blue 6. 8131 Fitting - 1/8 BSPP x 6 mm OD barb 7. MC7302 Sensor bracket 8. MC7301 MicroCoat controller brackets 9. 8155 Fitting - 8 mm x 6 mm push-in tee 10. 8150 Bleed valve 11. 4084 MC2000 sensor adapter (not shown) 18

8 Connect to MicroCoat controller To AC line power To Control Air To Fluid Inlet 1 9 5 3 10 6 4 2 6 7 Connect to MCFILTER 19

For Nordson EFD LLC sales and service in over 30 countries, contact Nordson EFD or go to www.nordsonefd.com East Providence, RI USA USA & Canada: 800-556-3484 +1-401-431-7000 info@nordsonefd.com Dunstable, Bedfordshire, UK 0800 585733; +44 (0) 1582 666334 Ireland 00800 8272 9444 europe@nordsonefd.com China: +86 (21) 3866 9006 china@nordsonefd.com Singapore: +65 6796 9522 sin-mal@nordsonefd.com The Wave Design is a trademark of Nordson Corporation. 2012 Nordson Corporation 7023835 v071012 This equipment is regulated by the European Union under WEEE Directive (2002/96/EC). See www.nordsonefd.com for information about how to properly dispose of this equipment. NORDSON EFD ONE YEAR LIMITED WARRANTY Nordson EFD products are warranted for one year from date of purchase to be free from defects in material and workmanship (but not against damage caused by misuse, abrasion, corrosion, negligence, accident, faulty installation or by dispensing material incompatible with equipment) when the equipment is installed and operated in accordance with factory recommendations and instructions. Nordson EFD will repair or replace free of charge any part of the equipment thus found to be defective, on authorized return of the part prepaid to our factory during the warranty period. In no event shall any liability or obligation of Nordson EFD arising from this warranty exceed the purchase price of the equipment. This warranty is valid only when oil-free, clean, dry, filtered air is used. Nordson EFD makes no warranty of merchantability or fitness for a particular purpose. In no event shall Nordson EFD be liable for incidental or consequential damages.