Section 1. Information before installation

Similar documents
Hydroxynator H A /01. Instructions for installation and use English. More languages on:

WELCOME TO ZODIAC. PRIVATE BAG X127 HALFWAY HOUSE 1685 CUSTOMER CARE HELPLINE 0860 ZODIAC ( )

Instructions for installation and use English. More documents on: H B /09

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Notice d installation et d utilisation Français. Instructions for installation and use English. Montage- und Gebrauchsanleitung Deutsch

Closing procedures for in-ground pools

Closing procedures for above-ground pools

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Instructions for installation and use English. More languages on: H A /11

SWIMMING POOL HEAT PUMP Owners Manual

SALT WATER CHLORINE GENERATOR. Model: SMC20TA & SMC30TA SMC INSTRUCTION MANUAL

MP920 SALT CHLORINATOR

Instructions for installation and use RE/I. Industrial electric heater for swimming pool

Owner s Manual RD432-0 Chemical Controller

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

FloPro e3 H C /01. Instructions for installation and use - English. More documents on:

M770 ph Controller Owner s Manual

SOMMAIRE CONTENTS SUMARIO SOMMARIO SUMARIO INHALTSVERZEICHNIS ENGLISH

M790 ph/orp Controller. Owner s Manual

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Owner s Manual for Swimming Pool Heat Pump

Ozone Generator Systems

EcoMaster - Residential Pools up to 40,000 Gallons

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Owner s Manual PRINTED IN CANADA 05/2009

Ozone Generator Systems

HOT WASHER MODEL NO: KING150

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Clear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual

Instruction Manual Model: IM03A

1. Information before installation General terms of delivery, storage and transport

Leonardo Cell Easy to use with advanced features

Instructions for installation

INSTRUCTION BOOK. BioDoser. Simple, Fully Programmable Dosing System. BioDoser. Version 1.0b, 25-Oct Please read before you call us for advice.

Robot Pool Cleaner by Maytronics. User Instructions. Guide d utilisation. Istruzioni per l uso. Instrucciones para el Usuario DEU

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

Sensor Control Panel

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation & Operating Guide

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

Product waste disposal - Protection of the environment:

MAXI-FLO STAINLESS STEEL AND TITANIUM HEAT EXCHANGER FOR SWIMMING POOLS & SPAS INSTALLATION AND MAINTENANCE MANUAL

HARMSCO INSTALLATION AND OPERATION MANUAL UPFLOW SWIMMING POOL CARTRIDGE FILTER CARTRIDGE CLEANING INSTRUCTIONS HARMSCO CARTRIDGES

Q1 - Q2 - Q3 - Q4 Q2

MODEL ORP/pH Digital Controller

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Installation Instructions & Operating Manual

Swimming Pool Heat Pump

Closing procedures for in-ground pools

Fully Automatic Water Filters

1. Information before installation General terms of delivery, storage and transport

POOL WINTERIZING INSTRUCTIONS

Instructions for installation and use English

CONTENTS. 1.1 General terms of delivery Voltage Water treatment... 2

O P E R A T I N G M A N U A L

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

EcoMaster - Residential Pools up to 40,000 Gallons

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Instructions for installation and use (to be kept in a safe place) English : page...19

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Curved Metal Panel Heater

INSTALLATION MANUAL. G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida

Installation Instructions & Operating Manual. Heat Exchanger PLEASE READ CAREFULLY BEFORE INSTALLING. Incorrect Installation Will Affect Your Warranty

PORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING

WATER HEATER FOR POOL & SPA

CZ51202 Larder fridge

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

Installation, Operation & Maintenance Guide

1850 Series TRIPLE TREAT Operation Manual

THE ULTIMATE NON-CHEMICAL POOL/SPA WATER STERILISATION

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

Solar Pool Ionizer and Purifier

I. Best Management Practices (BMPs) to Prevent Blockages in the Sanitary Sewer System

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

User manual AG-WT10. Indoor unit air/air heat pump UHB GB

Liberty Premium 8. User Instructions

wc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance

MW402 Integrated Dishwasher

AquaRite. Troubleshooting Guide Residential. TSG-AQR159d. Copyright 2017 Hayward Industries Inc.

SAFETY AND OPERATING MANUAL

Clean Water Made Easy

INSTALLATION AND USER'S GUIDE

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

M820 ph/dual ORP Controller. Owner s Manual

OWNER S MANUAL. Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Istruzioni per l uso Questo modello è dotato di telecomando. Le istruzioni per l uso si trovano in un documento separato.

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: AP AQUAS Pool Package

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Autotrol Performa FA Valve

ENERGY RATING A joint government and industry program Viron P300 evo Variable Speed Pool Pump Noise dba. Head. Power W

Quick Start Guide. For product manuals and further installation / operation procedures visit

MultiFix Central unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

PORTABLE AIR CONDITIONER OWNER S MANUAL

Transcription:

2 3

Section 1. Information before installation 1.1 General delivery conditions All equipment, even carriage and packaging paid, is shipped at the recipient s risk. If damaged caused during transport is observed, the recipient should write appropriate comments on the delivery note provided by the carrier (and confirmed in writing to the carrier by registered letter). 1.2 Contents Ei Classic 1 x Power Pack (control box) 1 x Electroytic cell 1 x Owner s manual 1 x Screw kit 1 x Warranty card 1.3 Technical specifications Power supply voltage Electric power Protection index Box size (l x h x d) Cell size (l x h x d) Weight (box + cell) 220-240 Vac-50 Hz Max. 140 W IPX5 28.5 x 40.5 x 12.5 cm 21.5 x 9 x 8 cm 6.0 kg (+/- 500 g depending on model) Minimum Maximum Flow through the cell 5 m 3 /h 18 m 3 /h - 50 mm Pressure in the cell / 2 bar Operating water temperature 5 C 40 C 4 5

Section 2. Installation 2.3 Installing the cell 2.1 Preparing the pool: water balance These appliances are designed to disinfect pool water using its salt water chlorination function. It is essential that the pool water balance is controlled and adjusted before installing the appliance. Making sure that the pool water balance is correct from the very start will reduce the likelihood of encountering problems on the first days of operation or during the season the pool is in use. Even though it is an autonomous system, it is essential to regularly analyse the water to check the water balance parameters and adjust them if necessary. Salt Concentration 4000ppm ph 7.2-7.6* Chlorine Stabiliser (Cyanuric Acid) Total Alkalinity Calcium Hardness Free Chlorine 40-80ppm (up to 100ppm in hotter regions) 80-150ppm* 175-275ppm* 1-3ppm *Values may vary, within their ranges, depending on pool surface i.e. concrete, fibreglass or vinyl ppm: parts per million 2.2 Installing the control box 1. The control box must be installed in a dry ventilated equipment area protected against frost, with no pool maintenance products stored nearby. 2. It must not be installed more than 1.5 metres from the cell (maximum cable length). 3. If the box is fixed to a post, a watertight panel must be fixed behind the control box (350x400 mm minimum). 4. Fix the support solidly to the wall or the watertight panel, and place the control box on it using the screws provided. Figure 1. 1. The cell must be installed on the piping after the filtering, after any measurement sensors, and after eventual heating systems. 2. The position of the cell, relative to other equipment, should be such that gases generated. under normal operation should not accumulate in any receptacles where gases in excess. of 2 litres may accumulate under normal operation. e.g. filter tanks, header tanks, solar systems, bypass pipe loops, heaters, etc. 3. The cell must be horizontal: The water inlet and outlet will be pointed downwards. Water can circulate in both directions. 4. The pipe unions can be glued to the PVC pipes using a suitable PVC glue. 5. Ensure that the surfaces to be glued are cleaned before gluing. After gluing, hold in position for at least 30 seconds. 6. Check that the edges are perfectly smooth and deburred. 7. If a valve is required after the cell it should always be a non-return valve not a manually operated version. The cell must always be the last element placed on the pool return pipe (see Figure 1.). If you installed the cell on a by-pass, it is recommended to fit a check valve downstream from the cell and not a manual valve, to avoid any risk of incorrect handling. 6 7

2.4 Electrical connections 2.4.1 Connecting the control box The salt water chlorinator must be connected in compliance with the applicable standards in the country of installation. Ei Classic: Mandatory connection: Installed directly to the DB timer together with the pump so that the chlorinator is supplied with power when the filtration system is in operation. Ei Classic Connections F E D Section 3. Use 3.1 Description of the Ei Classic User Interface Increase or reduce the chlorine production: 20 % 40 % 60 % 80 % 100 % Activate / deactivate the chlorine production by a short press (Standby). Switch on the device with a short press. Switch off the device with a long press (5 seconds). FLOW SALT Red indicator showing the absence of flow and/or presence of air in the cell. Orange indicator showing a water conductivity problem (not enough salt, water too cold, etc.). 3.1.2 Polarity inversion The choice of polarity inversion cycles may affect the cell lifetime (+/- 15%). Ask your professional reseller for advice in case of doubt. Ei Classic A Mains power supply 220-240 Vac / 50 Hz X B Cell power supply X C Memory battery type CR2032 X D Ribbon cables at the user interface X (1) E Transformer connections X F Fuse 2.5 A time-delayed X Ei Classic is equipped with a polarity inversion system making the cell self-cleaning (default setting = 5 hours). 8 9

Section 4. Maintenance 4.1 Washing the pool filter (backwash) Ei Classic MUST be switched off when washing the filter. When the device is on (filtration on), press the button for 5 seconds (long press) to switch it off. After cleaning the filter, switch the device on again by pressing the (short press). It will resume normal operation. The manufacturer cannot be held liable in case of incorrect handling. 4.2 Cleaning the electrode button The Ei Classic is equipped with a smart polarity inversion system designed to reduce scale formation on the electrode plates. However manual cleaning may be required in regions where the water is very hard. 1. Turn off the chlorinator and the filtration system, close the isolation valves (if installed), remove the protection cover and disconnect the cell power cable. 2. Unscrew the two pipe unions that attach the body of the cell to the piping and carefully remove the assembly. Lay it down flat with the entry/exit openings facing upwards. Pour some cleaning solution into the body of the cell until the electrodes are completely covered. If you do not use a commercially available cleaning solution, you can manufacture it yourself by carefully adding 1 part of hydrochloric acid to 10 parts of water. Always add the acid to the water and never the reverse. 3. Leave the cleaning solution to dissolve the scale deposit for about 15 minutes. Dispose of the cleaning solution at an approved waste recycling site, never pour into the rainwater drainage system or into the sewers. 4. Rinse the electrode in running water. Reassemble the electrode, tighten the pipe unions and make sure that there are no leaks. 5. Open the stop valves. Replace the electrical connections on the electrodes. Open the isolation valves and restart the filtration system and chlorinator. 4.3 Wintering The chlorinator has a protective system to limit chlorine production under bad operating conditions such as cold water (winter) or a lack of salt. Section 5. Troubleshooting PROBLEM POSSIBLE CAUSES SOLUTION FLOW INDICATOR ON SALT INDICATOR ON Stop or failure of the filtration pump Presence of air or gas in the cell By-pass valves set incorrectly Bad or no connection between flow sensor cable and cell Lack of salt (4000ppm) due to water loss or dilution (filter backwash, water renewal, rain, leaks, etc. Pool water temperature too low (<18º C, variable). Cell scaled up or worn If the problem continues contact your installer. Section 6. Product conformity Check the pump and its programming clock, the filter, the skimmer and the by-pass valves. Clean them if necessary Ensure sufficient water flow through the cell Ensure sufficient water flow through the cell Ensure that the blue sensor cable is connected and not corroded Add salt to the pool to keep the level at 4000ppm. If you do not know the salt level or how to test it, consult your installer Basic production limitation signal when the water is too cold. Reduce chlorine production or add salt to compensate Clean or replace the cell This appliance has been designed and built according to the following standards: EN6000-6-1: 2006 EN6000-6-3: 2007 IEC 61558-2-6: 1997 AS/ NZ 3136-2001 (IEC 60065 + IEC 60335-2-60) Relative to which it is compliant. The product has been tested under the normal conditions of use. PLEASE NOTE: Compliance label for this is located on the back of the powerpack. 1. Active wintering = filtering operational in winter: below 10 C it is preferable to switch off the chlorinator. Above this temperature you can leave it running. 2. Passive wintering = lower water level and drain piping: leave the electrode dry in its cell with its isolation valves open. 10 11

12