PCD110X - Premium Choice with DC Motor (Ceiling Mounted Ventilation Fans)

Similar documents
Energy Efficiency (CFM/Watts)* Watts PC /31 0.1/ / / / /63 <0.3

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Ventilation Solutions

Featuring Vent Lights and Premium Grilles

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

PA 500/1100V Ultra Quiet Ventilation Fan

Bathroom Ventilation

OLC(T) 100 FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

APPLICATION DATA SHEET

SP-220. Features. Combustible handheld gas leakage detector

ENVIRON INTERNATIONAL CORPORATION THE USE OF A GAS-IMAGING DEVICE FOR DETECTING FUGITIVE EMISSIONS IN ETHYLENE FACILITIES

Ultra SERIES. BroanUltra.ca. Broan-NuTone Canada Inc Tristar Drive Mississauga, Ontario L5T 1H /12

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Lodging/Hotel. Panasonic Ventilation Fans

Ultra SERIES. We ve Revolutionized the Ventilation Fan

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

3M Oldham OLCT 100. Description. Fixed Gas Detector

Vacuum and Compressor Systems for the Chemical Process Industry

TM-802 Formaldehyde Meter User s Manual

FV-08VKML1, FV-08VKSL1, FV-08VKM1, FV-08VKS1, FV-08VKL1, FV-08VK1, FV-05VK1

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

AT-G-SENSE Gas Sensing System

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

ESD3000 ESD200 Combustible / Toxic Gas Detector

Air-Quality Detection Module. User s Manual

Outside Air Requirements... SOLVED!

Ventilation and Indoor Air Quality

Reduces common odors. 685mm tall x 140mm width x 226mm dia. Base 4.5kgs. Living room, Bedroom, Hospital recovery room, ICU / OT

Air-Quality Detection Module. User s Manual

ESD500. ESD500 Combustible / Toxic Gas Detector

Multifunction IAQ Monitor

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Low mg/m

Residential Balanced Ventilation Systems

Vacuum Pumps America Inc. Dry Screw Vacuum Pump VSS Series

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

IAQ_100 C Package

Ultra SERIES. A revolution in ventilation fan technology

3 Box Inline Fans...4 Super Slimline Series...5 Universal DC Plus Series...6 Universal Fans...7 Universal Dual Speed Fans...

Tradition & Technology

Sensor Suite Sensors. Sensor Suite Sensors: Overview. Ordering Guide. Overview FEATURES

NGD8800 USER S MANUAL

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

Frequently Asked Questions

OXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning

UV Sentry. Cost Effective Perimeter & LDAR Monitoring. ...Precise, Species Specific Fugitive Emissions Quantification

AT-G-SENSE Gas Sensing System

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

IOA/PAG AIR TREATMENT TASK FORCE USER SUCCESS REPORT

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

Monitoring for Toxic VOCs in Oil Industry Applications

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

Learn which 19 houseplants clean the air

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Blowing Up Will Ruin Your Whole Day. Understanding and using the Combustible Gas Sensors used in portable handheld detectors

The 2018 Ventilation Extravaganza. Rick Karg Residential Energy Dynamics 2018

SBS-H2 Hydrogen Gas Detector Kit

Fired Heaters Key to Efficient Operation of Refineries and Petrochemicals

SENTRY-MS Mono-static Multi-gas Open Path Analyzer

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Gas detector tubes are most effective as a reference device for conducting spot checks, which gives an idea of present gas at that moment in time.

The MiCS-6814 is a compact MOS sensor with three fully independent sensing elements on one package.

Silicon-Lined Canister Cleaning Practices and Blank VOC Concentrations. Jason S. Herrington, Gary Stidsen, Trent Sprenkle, Steve Kozel

ASHRAE Safety Standards. Mechanical Rooms and Gas Detection in Commercial Applications

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Indoor Environmental Quality

Macurco HD-11 Hydrogen Gas Detector

FirstEnergy Program Overview

Put the V back in HVAC

MODELS HS 1500-OWO HS-1500-OTR INFRARED ELECTRICAL HEATER SAFETY INSTRUCTIONS & OPERATION MANUAL

MGS-350 Gas Detector Installation and Operation Manual Instruction Revision 1 February 2013 Product Leadership Training Service

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Explosion-proof Duct Heaters

INSTALLATION INSTRUCTIONS

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

PURIFICATION DRYING SYSTEMS

Integrated Area Monitor and Optional 16-Channel Controller Installation and Operation Manual Instruction Rev 1 March 2014

IGD.CO.UK

TUBE ARCHITECTURAL DS-PD05

The MiCS-6814 is a compact MOS sensor with three fully independent sensing elements on one package.

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

Turbo Inline Fan, White - Non Illuminated Art no.33500

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

FV0511VQ1 (Fan Only) FV1115VQ1 (Fan Only) FV0511VQL1 (Fan/Light) FV1115VQL1 (Fan/Light) Yes Yes Yes Yes

CD100A COMBUSTIBLE GAS DETECTOR

MGD - Murco Gas detector / Monitor. Installation & Operation* 08 ASH (1)

Fire Alarm System Accessories

White - Non Illuminated Art no White - Cool White LED Art no.32600

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

Xgard. Fixed detectors For flammable, toxic or oxygen gases

PT0E Portable Gas Leak Detector. SP-220 Series. Operating Manual (PT0E-139)

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

1. GENERAL TECHNICAL INFORMATION

Transcription:

PCD110X - Premium Choice with DC Motor Performance & Ventilating fan shall be S&P PCD110X mounted in the ceiling. The fan shall have a 6-year warranty. The fan shall be HVI Certified at 0.1 inch water gauge for CFM performance above. The fan shall be ENERGY STAR qualified. The motor shall be ETL and cetl Listed with impedance protection plus additional thermal protection. PCD110X-Submittal_2-14-2017

PCD110XM - Premium Choice with DC Motor Performance & Built-in Motion Motion Sensing Lighted Grille (CFL) Installation Distance: 7 to 9 feet Sensing range is within the cone of angle of 90 Adjustable continuous speed or intermittent reduced speed up to 50% Ventilating fan shall be S&P fan mounted in the ceiling. PCD110XM shall come with a built-in motion sensor, timer delay, and speed control. The fan shall have a 6-year warranty The fan shall be HVI Certified at 0.1 inch water gauge for CFM performance above. The fan shall be ENERGY STAR qualified. The motor shall be ETL and cetl Listed with impedance protection plus additional thermal protection. PCD110XM-Submittal_2-14-2017

PCD110XH - Premium Choice with DC Motor Performance & CFM @ 0.25 SP 64 77 89 100 Sones @ 0.1 SP 0.3 0.5 0.8 1.1 Watts @ 0.1 SP 5.5 10 11.5 14.5 16.4 11 10.4 9.7 Built-in Humidity Detects rapid rise in humidity Field adjustable humidity sensitivity with 50-100% range. Factory setting is 75% Ventilating fan shall be S&P fan shall be mounted in the ceiling. PCD110XH shall come with a built-in humidity sensor and speed delay timer. The fan shall have a 6-year warranty. The fan shall be HVI Certified at 0.1 inch water gauge for CFM performance above. The motor shall be ETL and cetl Listed with impedance protection plus additional thermal protection. PCD110XH-Submittal_2-14-2017

PCD110XMH - Premium Choice with DC Motor Performance & Built-in Motion and Humidity Motion Sensing Lighted Grille (CFL) Installation Distance: 7 to 9 feet Sensing range is within the cone of angle of 90 Adjustable continuous speed or intermittent reduced speed up to 50% Detects rapid rise in humidity Field adjustable humidity sensitivity with 50-100% range. Factory setting is 75% Ventilating fan shall be S&P fan mounted in the ceiling. PCD110XMH shall come with a built-in motion sensor, humidity sensor, timer delay, and speed control. The fan shall have a 6-year warranty The fan shall be HVI Certified at 0.1 inch water gauge for CFM performance above. The fan shall be ENERGY STAR qualified. The motor shall be ETL and cetl Listed with impedance protection plus additional thermal protection. PCD110XMH-Submittal_2-14-2017

PCD110XIAQS - Premium Choice with DC Motor Performance & Built-in VOC and Humidity Detects VOCs and/or rapid rise in humidity Semiconductor gas sensor, detecting a wide range of VOCs Monitoring range is 400-2000 ppm equivalent CO2 Field adjustable humidity sensitivity with 50-100% range. Factory setting is 75% Continuous speed control to run fan continuously Integrated control switch to turn features on and off Ventilating fan shall be S&P PCD110XIAQS mounted in the ceiling with built-in VOC and humidity sensors. The fan shall have a 6-year limited warranty. The fan shall be HVI Certified at 0.1 inch water gauge for CFM performance above. The fan shall be ENERGY STAR qualified. The motor shall be ETL and cetl Listed with impedance protection plus additional thermal protection. Detectable gases*: Ammonia Acetone Benzene Carbon Monoxide Ethylene glycol Formaldehyde Methylene chloride Perchloroethylene Toluene Xylene 1,3-butadiene and others Equivalent Carbon Dioxide CO2(equiv) 0V 400ppm CO2(equiv) 1V 720ppm CO2(equiv) 2V 1040ppm CO2(equiv) 3V 1360ppm CO2(equiv) 4V 1680ppm CO2(equiv) 5V 2000ppm CO2(equiv) *The sensor must not be exposed to high concentrations of organic solvents, ammonia, silicone vapor or cigarettesmoke in order void poisoning the sensitive layer. PCD110XIAQS-Submittal_2-14-2017