A modern classic. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

Similar documents
panel plus horizontal wall-mounted

DECO louvre horizontal. A modern classic. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

DECO louvre vertical. A modern classic. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

ARISTOCRAT. Elite towel rail for every situation

arco plus Distinctively elegant vertical radiators

IGUANA visio. Radiators that mirror your style

High output, high art. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

IGUANA circo wall-mounted. Distinctively elegant vertical radiators

Linea Plus. Freestanding. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

circo PLUS wall-mounted

Play DBE. Colourful, fun, safe. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

BRISE. Heating and cooling from a single radiator

Basic DBE. Easy installation in less than two hours

FREEDOM 2019.EX CZ - 21/11/18

VeRtiga the new benchmark for design at super-low water temperatures

QUATRO CANAL 2019.EX

CLIMA CANAL Lyngson as

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

MINI CANAL DBE 2015.UK

Units for suspended ceilings

Passive chilled beams

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

new DRAFT This is not the final version of this document! But prices and outputs should be good. play Playful warmth, colourful comfort

IMI Heimeier Kit Hydroca ble

Quatro canal Super-powered climate control for 4-pipe systems

IRONING BOARD CATALOG FOR HOME

CLIMA CANAL. Complete climate control and high power

Zehnder Electric radiators for living rooms

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

VOGEL&NOOT. Convectors & heating panels. heatingthroughinnovation.

Type CODE Speed Heating Cooling

Towel Warmers Electric Rad catalogue

WHE 2.24 / WHE 2.24 FF

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Units for suspended cei lings

PLAN KLASIK LINE KLASIK

Mikrotherm. Manual Radiator Valves With presetting

BRIZA Super slim and powerful heating, cooling

Metering systems 0548EN April 2014

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

3RD GENERATION PANEL RADIATOR

3RD GENERATION PANEL RADIATOR

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

INSTRUCTIONS AND WARRANTY

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

1. Oxygen Master 2. Oxygen Sensor 3. Oxygen Refresh Stand-Alone 4. Touch button controls 4. Oxygen Refresh Built-In 5.

CLIMA CANAL Complete climate control and high power

LST Plus Vertical. Plus Vertical 3 models. Lengths: 560mm, 660mm & 760mm. Outputs: 1335 to 1862 watts, 4555 to 6353 Btu/hr

User Manual. Hob PH601SS

made in Italy Extruded Radiators with Anticorrosion Treatment

EuroPlan/EuroProfil Panel radiators

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

Thermostatic valves with radiator connection systems

Multilux 4-Eclipse-Set

EuroPlan/EuroProfil Panel radiators

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Thermostatic valve bodies

This limited warranty is valid for domestic kitchen use and is subject to the terms and conditions stated in this folder.

Flush individual room control for floor heating systems

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

AHRI Guideline N with Addendum Guideline for Assignment of Refrigerant Container Colors. ARI Standard 1200

BOOST INTO THE FUTURE

INSTRUCTIONS AND WARRANTY

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

BRISE. Super-power for heating, cooling and ventilation.

This guarantee is subject to the terms and conditions stated in this brochure.

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

CLIMA CANAL HYBRID CLIMA CANAL. Low Water Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING LOW TEMPERATURE SYSTEM / HEATING

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Valid from

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Thermostatic valve bodies

Free standing convectors with natural convection. new! 02/18

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

1.5L Fryer v1.0. Model: SD6060N. Helpline. SD6060N_IM.indd 1 07/10/ :58

HERZ Regulating valve 4002

Chilled Ceiling Elements

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

INSTRUCTIONS FOR USE AND INSTALLATION Glass Ceramic Hobs HVK 400-1

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

NOXX. cubicle system

MOD COD REV. 0 del 20/12/2012

Kitchen SAVE THE SALES RECEIPT! It is your proof of purchase and required for the warranty to apply.

Steam Generator Iron

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

INSTRUCTIONS AND WARRANTY MODEL NO. SI70 STEAM, SPRAY & SURGE/BURST IRON

Transcription:

DECO PANEL horizontal A modern classic

1 8 Deco Panel Horizontal Dimensions Panel Horizontal Single Product code wall-mounted: PHSW Product code freestanding: PHSF standard connection variant Panel Horizontal Double Product code wall-mounted: PHDW Product code freestanding: PHDF L-160 80 L-160 80 12 50 L-0 L 7 102 7 1/2" H-60 H 90 12 57 L-0 L 20 15 102 6 60 102 52 1/2" H-60 0 H 20 15 102 6 60 62 min. 100 standard connection variant 102 min. 100 standard connection variant L > 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 000 H > 280 40 400 470 50 590 660 720 780 840 910 970 Connections Standard connection Order code: 18. Connection 18 or 81. Side end connection One-sided: order code 2 or 67 Cross-over: order code 7 or 62 2 6 7 Key: 1 =flow, 2 = return Single point connection Order code: 11 (left) or 88 (right) 1 8 Always use a vertical diffusion tube (Ø 10-12mm) of min. length 100mm and a reduction washer. all fixing Fixing Standard wall fixing All dimensions in mm PHDF

Options Side end fixing 6 B A 20 PHSS PHDS A 20 7 B 40 68 When ordering side end fixings, a side end connection is not possible. Non-standard fixings are welded to the radiator and cannot be changed or reordered afterwards. Please check carefully if the desired options are ordered correctly. Incorrect orders will not be taken back. For positioning of freestanding model PHDS - Single PHDF - Double 6 6 6 2 7 2 7 2 7 Single or Double horizontal radiator Maximum height 470mm PHDF has an option connection set of 1 or Order codes: PHSF = single radiator from 2200mm in length use 2 feet, from 2400 in length use feet PHDF = double radiator from 2200mm in length use 2 feet, from 2400 in length use feet To create the order code begin by using the radiator code PHSF or PHDF, then the height in cm, the width in cm, then the colour code followed by the connection. Example order code: PHSF. 100 028 201/LL or RR

Outputs Outputs in watts at 75/65/20 C & 55/45/20 C, in accordance with EN442 Supplied as Standard Deco Panel Horizontal Single code height length colour connection Order code: PHSW 028 180 2 /18 (Example order code shown is for a 280mm high radiator, 1800mm long) Colours: 001 Sandblast grey metallic 201 white or 2 traffic white Connection 18 underneath Chrome-plated air vent and drain plug Wall fixing Height Length > 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 000 280 75/65/20 270 24 78 42 486 540 594 648 702 756 810 55/45/20 15 162 189 217 244 271 298 25 52 79 406 40 75/65/20 44 41 481 550 619 688 757 825 894 96 102 55/45/20 17 208 242 276 11 46 80 415 449 484 519 400 75/65/20 418 501 585 668 752 85 919 1002 1086 1170 125 55/45/20 210 252 295 6 79 420 46 505 547 589 61 470 75/65/20 491 589 687 786 884 982 1080 1178 1276 175 147 55/45/20 248 297 47 97 446 496 545 595 644 694 744 50 75/65/20 56 676 789 901 1014 1127 129 152 1465 1577 1690 55/45/20 285 42 99 456 51 570 627 684 742 798 855 590 75/65/20 65 762 889 1015 1142 1269 196 152 1650 1777 1904 55/45/20 22 86 451 515 579 644 708 772 87 901 966 660 75/65/20 705 846 987 1128 1268 1409 1550 1691 182 197 2114 55/45/20 58 40 502 574 645 716 788 860 92 100 1075 720 75/65/20 77 928 108 127 192 1547 1701 1856 2011 2165 220 55/45/20 94 47 552 61 710 789 867 946 1025 1104 118 780 75/65/20 841 1009 1177 145 151 1681 1849 2017 2185 254 2522 55/45/20 40 515 601 687 77 859 945 100 1116 1202 1288 840 75/65/20 906 1087 1269 1450 161 1812 1994 2175 256 257 2719 55/45/20 464 557 650 74 85 928 1021 1114 1207 1299 192 910 75/65/20 970 1164 158 1552 1746 1940 214 229 252 2717 2911 55/45/20 498 597 697 796 896 996 1095 1195 1295 194 1494 970 75/65/20 10 129 1446 1652 1859 2065 2272 2478 2685 2891 098 55/45/20 51 67 744 850 956 1062 1169 1275 181 1487 1594 All dimensions are shown in millimetres Output measured in accordance with EN442, at a water temperature of 75/65 C and a room temperature of 20 C (T=50).

Outputs Outputs in watts at 75/65/20 C & 55/45/20 C, in accordance with EN442 Supplied as Standard Deco Panel Horizontal Double code height length colour connection Order code: PHDW 028 180 001 /18 (Example order code shown is for a 2800mm high radiator, 1800mm long.) Colours: 001 Sandblast grey metallic 201 white or 2 traffic white Connection 18 underneath Chrome-plated air vent and drain plug Wall fixing Height Length > 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 000 280 75/65/20 526 62 77 842 948 105 1158 1264 169 1474 1579 55/45/20 270 25 79 4 487 541 595 650 704 758 812 40 75/65/20 644 772 901 100 1158 1287 1416 1544 167 1802 191 55/45/20 1 97 464 50 596 662 729 794 861 927 99 400 75/65/20 757 909 1060 1212 16 1515 1666 1818 1969 2121 2272 55/45/20 90 468 546 624 702 780 858 96 1014 1092 1170 470 75/65/20 869 1042 1216 190 1564 177 1911 2085 2259 242 2606 55/45/20 448 57 626 716 805 895 984 1074 116 125 142 50 75/65/20 978 117 169 1564 1760 1955 2151 246 2542 277 29 55/45/20 504 605 706 806 907 1008 1109 1209 111 1411 1512 590 75/65/20 1084 101 1518 175 1951 2168 285 2602 2819 05 252 55/45/20 559 671 78 895 1006 1118 120 142 1454 1565 1677 660 75/65/20 1189 1426 1664 1902 219 277 2615 2852 090 28 566 55/45/20 614 76 859 982 1104 1227 150 1472 1595 1717 1840 720 75/65/20 1291 1549 1807 2066 224 2582 2840 098 57 615 87 55/45/20 667 800 9 1067 1201 14 1467 1600 174 1867 2001 780 75/65/20 192 1670 1948 2227 2505 278 062 40 618 897 4175 55/45/20 719 86 1007 1151 1295 148 158 1726 1870 2014 2158 840 75/65/20 1490 1789 2087 285 268 2981 279 577 875 417 4471 55/45/20 771 925 1079 12 187 1542 1696 1850 2004 2158 212 910 75/65/20 1588 1905 222 2540 2858 175 49 810 4128 4445 476 55/45/20 822 986 1151 115 1479 1644 1808 1972 217 201 2466 970 75/65/20 168 2020 256 269 00 66 70 409 476 471 5049 55/45/20 872 1046 1220 195 1569 174 1918 2092 2266 2441 2615 All dimensions are shown in millimetres Output measured in accordance with EN442, at a water temperature of 75/65 C and a room temperature of 20 C (ΔT=50).

Connection Sets The order code of the connection set will be completed with the sleeve coupling code Set 1 For connection to the wall Thermostatic head CODE.MW2.MW.1... white CODE.MW2.MC.1... chrome CODE.MW2.MB.1... black Set 2 For connection to the floor Deco angled lockshield Deco straight lockshield Deco angled manual valve Thermostatic heads DW Chrome/ White DC Thermostatic head CODE.MF2.MW.1... CODE.MF2.MC.1... white chrome Deco straight manual valve Chrome CODE.MF2.MB.1... black Set Set 6 For connection to the wall Standard Kv 6 Reduced Kv Deco angled lockshield CODE.JW2.DW.1... CODE.RW2.DW.1... CODE.JW2.DC.1... CODE.RW2.DC.1... Deco angled thermostatic valve Thermostatic head Set 4 Set 7 For connection to the floor 4 Standard Kv 7 Reduced Kv Deco straight lockshield Deco straight thermostatic valve CODE.JF2.DW.1... CODE.JF2.DC.1... CODE.RF2.DW.1... CODE.RF2.DC.1... Thermostatic head Set 5 Set 8 For connection to the wall Thermostatic head 5 Standard Kv 8 Reduced Kv CODE.JH2.DW.1... CODE.RH2.DW.1... CODE.JH2.DC.1... CODE.RH2.DC.1... Double angled lockshield Double angled thermostatic valve

Connection Sets The order code of the connection set will be completed with the sleeve coupling code Set 81 For connection to the wall CODE.OW2.DW.1... Thermostatic head CODE.OW2.DC.1... Set 82 For connection to the floor Thermostatic head CODE.OF2.DW.1... CODE.OF2.DC.1... Deco Single point valve angled Deco Single point valve straight Thermostatic head Thermostatic head Sleeve Couplings Included in the price of the connection sets For Jaga valve - M24 For flexible steel or copper tube For synthetic tube Tube Ø Tube Ø 110 10/1 112 12/1 114 14/1 115 15/1 116 16/1 118 18/1 1/2 1/2 For tube 15/1 only 1/2 For tube 18/1 only 212 12/2 214 14/2 219 16/1.5 216 16/2 217 17/2 218 18/2 1/2 For RPE/ALU tube Steel tube for CH 1/2 Tube Ø 14 14/2 1/2 Tube Ø 501 1/2 16 16/2 50 /8 26 16/2.2 18 18/2 Complete ordering code with sleeve couplings according to the material used and diameter of the tube. The correct type of sleeve coupling is determined by the ordering code of the connection set Example: CODE. JF2.DW. 1. (insert relevant code from above)

Correction factors Average correction factors according to EN442-75/65/20 C TV TL TR_20 25 0 5 40 45 50 55 60 65 70 75 80 85 90 20 0.6 0.69 0.75 0.81 0.87 0.94 1.00 1.07 1.1 1.20 1.27 1.4 1.41 1.48 24 0.54 0.59 0.65 0.71 0.77 0.8 0.90 0.96 1.0 1.09 1.16 1.2 1.29 1.6 85 20 0.57 0.6 0.69 0.75 0.81 0.87 0.94 1.00 1.07 1.1 1.20 1.27 1.14 24 0.48 0.54 0.59 0.65 0.71 0.77 0.8 0.90 0.96 1.0 1.09 1.16 1.2 80 20 0.51 0.57 0.6 0.69 0.75 0.81 0.87 0.94 1.00 1.07 1.1 1.20 24 0.4 0.48 0.54 0.59 0.65 0.71 0.77 0.8 0.90 0.96 1.0 1.09 75 20 0.46 0.51 0.57 0.6 0.69 0.75 0.81 0.87 0.94 1.00 1.07 24 0.7 0.4 0.48 0.54 0.59 0.65 0.71 0.77 0.8 0.90 0.96 70 20 0.41 0.46 0.51 0.57 0.6 0.69 0.75 0.81 0.87 0.94 24 0.2 0.7 0.4 0.48 0.54 0.59 0.65 0.71 0.77 0.8 65 20 0.5 0.41 0.46 0.51 0.57 0.6 0.69 0.75 0.81 24 0.27 0.2 0.7 0.4 0.48 0.54 0.59 0.65 0.71 60 20 0.0 0.5 0.41 0.46 0.51 0.57 0.6 0.69 24 0.2 0.27 0.2 0.7 0.4 0.48 0.54 0.59 55 20 0.26 0.0 0.5 0.41 0.46 0.51 0.57 24 0.18 0.2 0.27 0.2 0.7 0.4 0.48 50 20 0.21 0.26 0.0 0.5 0.41 0.46 24 0.14 0.18 0.2 0.27 0.2 0.7 45 20 0.16 0.21 0.26 0.0 0.5 24 0.1 0.17 0.22 0.26 0.1 40 20 0.10 0.14 0.18 0.2 0.27 24 0.12 0.16 0.21 0.26 5 20 0.06 0.10 0.14 0.18 24 0.08 0.12 0.16 0 20 0.0 0.06 0.10 24 0.05 0.08 KEY Tv = flow temperature Tr = return temperature Tl = desired air temperature The indicated outputs with T 50 c and T 0 c are the exact outputs. T 50 c outputs are measured in accordance with EN442 and T 0 c outputs are calculated according to EN442. An average correction factor is given in this table for outputs at other T and is applicable for all dimensions. How to choose the right radiator? Rapid estimation of heat losses Calculate the volume of the room (L x W x H) and multiply this by the Watts/m³ figure given in the table below. Choose according to the level of insulation and the desired room temperature. Insulation 20 24 excellent 45 55 good 65 75 average 85 95 poor 100 115 Required output in Watts/m³ Example Use the table to determine the relevant correction factor with a water temperature of 80/60 c with a room temperature of 24 C. The correction factor = 0.90 Required output 1000 watts : 1000 divided by 0.90 = 1111 watts therefore search in this leaflet s standard output table for a product with an output of at least 1111 watts. Alternatively use the Radiator Finder search function on www.jaga.co.uk to identify all Jaga heating products with this required output. Output calculated in accordance with EN442, at a water temperature of 75/65 C and a room temperature of 20 C (ΔT=50).

Pressure drop mwk mce mws mwc 1 0.8 0.6 0.5 0.4 0. 0.2 bar 0.1 0.08 0.06 0.05 0.04 0.0 0.02 kpa 10 8 5 6 4 2 Pressure drop 0.1 0.08 0.06 0.05 0.04 0.0 0.02 0.01 0.008 0.006 0.005 0.004 0.00 0.002 1 0.8 0.6 0.5 0.4 0. 0.2 0.01 0.008 0.006 0.005 0.004 0.00 0.002 0.001 0.0008 0.0006 0.0005 0.0004 0.000 0.0002 0.1 0.08 0.06 0.05 0.04 0.0 0.02 0.001 0.0001 10 0.01 2 4 6 8 2 4 6 8 100 1000 Water flow in kg/h Weight & water content Weight in kg/cm Water content in litres/cm H Single Double 280 0.08 0.14 40 0.09 0.18 400 0.11 0.21 470 0.1 0.25 50 0.15 0.28 590 0.17 0.1 660 0.18 0.5 720 0.20 0.8 780 0.22 0.42 840 0.24 0.45 910 0.26 0.49 970 0.27 0.52 H Single Double 280 0.021 0.042 40 0.027 0.05 400 0.02 0.06 470 0.07 0.07 50 0.042 0.08 590 0.047 0.094 660 0.05 0.104 720 0.058 0.114 780 0.06 0.125 840 0.068 0.15 910 0.07 0.145 970 0.079 0.155

Product description Deco Panel Horizontal Material Composed of single or double steel collectors which support the steel radiation tubes. The radiation tubes are welded on the inside of the collector under the protection of gas, and with steel as a sole addition. Therefore no welding seams are visible on the outside of the radiator. Pressure test: 6 bar Working pressure:4.6 bar Composition The oval radiation tubes (60 x 10.4 x 1.5mm) are horizontally and lengthways placed on the vertical collector with an interdistance of mm. Single collector : 50 x 0 x mm Double collector: 90 x 0 xmm Transparency: none All fixing points are welding to the radiator. The supports to fit the wall are supplied with the standard delivery. Finish The radiators are sandblasted, degreased, phosphated, electrostatically lacquered with epoxy-polyester powder and finally stove enameled at 200 C. This high quality finish offers an optimal scratch resistance and is very easy to maintain. Thickness of the lacquer: min80 μ Connections The sockets ½ are integrated in the collectors and hence invisible. The sockets ½ at the top end and bottom end of the collectors stick out mm above the collector. The connections may be ordered at customer choice at top, bottom or at the side end of the radiator. Provided with a chrome plated air vent ½ and drain plug ½ How to install The building services engineer chooses the radiators considering the following conditions: A heat output calculation according to the standard. The heat output and the dimensions of the Deco Linea radiators according to EN 442. The radiators may be wall fitted with the wall fixings supplied, positioned perpendicular to the wall with 2 side end fixings left and 1 foot right or positioned perpendicular to the wall with 2 side end fixings right and 1 foot left. The specially designed thermostatic connection sets/ thermostatic Jaga Deco/ Deco Pro single point/ manual Jaga Deco valves can be connected to plastic central heating service pipes/ RPE/ALU. Tube / copper tube/ steel pipe. Jaga thermostatic heads/jaga Deco thermostatic heads chrome/ White/ Jaga Comap thermostatic heads silver/not to be/ to be fitted.

Jaga colours For Deco Panel Horizontal Standard colours RAL 9010 201 White RAL 9016 2 001 Traffic White Sandblast Grey Metallic Premium colours RAL 9001 RAL 9010 01 White 202 02 Off-white RAL 6009 212 12 Bahama 21 1 English Green 222 22 Capri 22 2 Natural Special colours RAL 705 20 0 Light Grey 214 14 Whisper Rose 224 24 Edelweis 002 Hammerstroke Silver/Black RAL 9005 204 04 Black RAL 5018 215 15 Turquoise 225 25 Jasmine 00 Claret Metallic 205 05 Pergamon 216 16 Bermuda RAL 00 226 26 Ruby Red 005 Smooth Grey Metallic 206 06 Manhattan RAL 8017 217 17 Chocolate Brown 228 28 Classic White RAL 9006 006 Aluminium RAL 500 RAL 7011 RAL 1004 208 08 Sapphire Blue 209 09 Dark Grey 210 10 Golden Yellow RAL 5015 RAL 4008 218 18 Azure 219 19 Violet 220 20 Aegean RAL 6000 RAL 7016 229 29 Patina Green 20 0 Aloa Blue 21 1 Anthracite Grey 007 Anthracite Metallic 008 Anthracite Structure RAL 000 211 11 Flaming Red 221 21 Calypso 22 2 Sunrise RAL 9016 Traffic White As it s impossible to reproduce colours with 100% accuracy, this colour chart is intended as a guide only. Colour swatches are available on request.

Jaga Guarantee Information 1 The guarantee is valid only if the equipment is properly and correctly used, by its first owner and if installed in accordance with the norms and instructions as detailed in the instruction leaflet and current industry standard practices. 2 The guarantee only applies to the equipment and the spare parts supplied by Jaga. Jaga has the choice between repair and replacement of the equipment or the spare parts. If any modifications have been made by Jaga to the standard product design, Jaga reserves the right to replace the guaranteed equipment with equivalent products or spare parts. The period of guarantee is mentioned in this certificate. The guarantee decreases every year on a straight line basis by an equal percentage in order to reach a zero guarantee at the end of the guarantee period (e.g. for a period of 10 years the annual decrease of the guarantees 10% of the invoiced value). Repaired or replaced product is guaranteed through to the end of the original guarantee period. 4 The guarantee is valid only on products displaying the appropriate identification information concerning product type and series. No guarantee is granted on equipment or spare parts lacking this information, on equipment where this information has been removed or altered, or on equipment that has been repaired or modified by persons not authorised by Jaga to carry out this work. 5 The customer is responsible for any damage caused as a result of errors in installation or use of incorrect fittings, or for any damage caused by electrical connections, faulty or damaged electrical installations or appliances, erroneous voltage or hydraulic pressure and all other errors not directly related to the product delivered by Jaga. The guarantee is also revoked when unsuitable parts or components are used. The guarantee for our heat exchangers is not valid if they are regularly drained, or if they are heated by means of industrial water, steam or water saturated by excessive quantities of oxygen. The quality of the system ater has to be in accordance with the VDI 205-2 directives. The guarantee is also not applicable if the heat exchangers are placed in unsuitable atmospheric surroundings, such as but not exclusively ammonia, caustic substances etc. 6 This guarantee excludes damage due to incorrect handling and/or use of the equipment, or due to formation of lime deposits, incorrect use of the safety valve, or to all equipment that is incorporated into the building in a way that means it cannot be accessed normally. 7 Any work undertaken or product supplied as a result of a guarantee claim that proves not to be valid will be charged for. Product supplied will be invoiced at the customer s standard purchasing terms, and labour will be charged at 50 per hour with a minimum labour charge of 200. 8 The guarantee period starts from the date of the invoice for supply of the products covered by the guarantee. If the invoice is not available, the date of production will be used based on the product ID number/series. 9 Only the courts of judicial district Hasselt (Belgium) are authorised to deal with disputes arising from this guarantee. It will apply Belgian law even when sales involved are subjects of EU member states as well as non-eu member countries. Casings and components Valves