M-SERIES SUBMITTAL DATA: SEZ-KD15NA4** & SUZ-KA15NA. Job Name: Location: Date: Submitted to: For Reference Approval Construction

Similar documents
SUBMITTAL DATA: SLZ-KA09NA... 9,000 BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS

Submitted to: For Reference Approval Construction

SUBMITTAL DATA: SLZ-KA09NA & SUZ-KA09NA 9,000 BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS. Cooling 4. Heating

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11

SUBMITTAL DATA: MSY-GL12NA & MUY-GL12NA 12,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: MSY-GL24NA & MUY-GL24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM. System Reference:

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SUBMITTAL DATA: PVA-A36AA7 & PUY-A36NKA7(-BS) 36,000 BTU/H AIR HANDLER AIR-CONDITIONING SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A36NKA7

SUBMITTAL DATA: PLA-A12EA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

SUBMITTAL DATA: PLA-A24EA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUY-A24NHA7

SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A36NKA7

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

INVERTER-driven. Split-ductless and ducted Comfort Systems M Series Full Line Catalog.


M-SERIES PRODUCT CATALOG

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Ductless Split Systems Concealed Duct Heat Pumps

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

The Hyper-Heat Advantage

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

ZONED COMFORT SOLUTIONS

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Ductless Split Systems Wall-mounted, Multizone Heat Pump

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

TECHNICAL & SERVICE MANUAL

Samsung 360 Cassette, Single Zone, Split System

SEZ-KD25VAQ.TH SEZ-KD35VAQ.TH SEZ-KD50VAQ.TH SEZ-KD60VAQ.TH SEZ-KD71VAQ.TH

M-Series RESIDENTIAL AND SELECT COMMERCIAL. MS MSY MSZ MXZ

Ductless Split Systems Ceiling Cassette Heat Pumps

DUCTLESS FULL LINE CATALOG

Residential and Light Commercial Ductless Systems Catalog

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

FBQ. DC Duct Heat Pump or Cooling Only

P-Series Full-line Catalog. Commercial-grade Applications. Smart, Efficient INVERTER-driven Ductless and Ducted Comfort Systems.

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

DESIGN & TECHNICAL MANUAL

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

HEAT PUMPS. Efficient Comfort For Every Season

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

Engineering Data Book

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

Ceiling type. Contents MMC-AP 1H2UL MMC-AP0181H2UL MMC-AP0361H2UL MMC-AP0421H2UL

ELECTRICAL QUANTITY WEIGHT (LB)

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Revision C: Specification has been corrected. The value of "Moisture removal" for MSZ-GE24NA and MSY-GE24NA has been corrected. [2.7 pt.

A single answer for multiple zones.

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

DESIGN & TECHNICAL MANUAL

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

THE WORLD S MOST EFFICIENT HEAT PUMP

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

Variable Refrigerant Flow (VRF), Multi-Zone, Heat Pump & Heat Recovery Systems

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

Product Data INDUSTRY LEADING FEATURES / BENEFITS

LV Series. SEER 15+ Concealed Built in Heat Pump

DESIGN & TECHNICAL MANUAL

4-Way Cassette type. Contents MMU-AP 2H2UL

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

Concealed ceiling unit with medium ESP

Redefining Comfort. Mr. Slim Splitductless

A single answer for multiple zones.

Air Conditioner CONTENTS

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

DUCTLESS SPLIT SYSTEMS

Engineering Data Book

ECOi TM. Variable Refrigerant Flow (VRF), Multi-Zone, Heat Pump & Heat Recovery Systems

DUCTLESS SPLIT SYSTEMS AIR CONDITIONERS HEAT PUMPS

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

DESIGN & TECHNICAL MANUAL

Ductless SPLIT SYSTEMS. cool only HEAT PUMPS

BENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

FTQ. Daikin Inverter Ducted Heat Pump

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

DESIGN & TECHNICAL MANUAL

Lennox Mini-Split Systems Year-Round Comfort and Performance

Transcription:

SUBMITTAL DATA: ** & SUZ-KA15NA 15, BTU/H HORIZONTAL-DUCTED HEAT-PUMP SYSTEMS M-SERIES Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule No.: **APPLIES TO INDOOR UNIT:.TH SEZ-KD15NAR1.TH R1.TH Indoor Unit: ** Outdoor Unit: SUZ-KA15NA GENERAL FEATURES Horizontal-ducted indoor unit for concealed applications Ultra thin body: 7-7/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" Air filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control AUTO fan speed control Automatic restart following a power outage ed warranty: five years parts and seven years compressors ACCESSORIES Indoor Unit Filter Box with MERV 8 Filters (FBL1-2) Bottom Return Plate (BRP-2) Outdoor Unit Drain Socket (MAC-86DS) Drain Pan Heater (MAC-6BH-U) Three-pole Disconnect Switch (TAZ-MS3) Air Outlet Guide (MAC-856SG) Mounting Base (DSD-N) Mounting Pad (ULTRILITE1) Wall-mounting Brackets (CWMB1) Controller Options Wireless Wall-mounted Remote Controller Kit (MHK1)* Portable Central Controller (MCCH1)* Outdoor Air Sensor (MOS1)* Wired Wall-mounted Controller (PAR-31MAA)* Simple MA Remote Controller (PAC-YT53CRAU)* *See Submittal for information on each option. Remote Temperature Sensor (M21-JKO-7) Hand-held Wireless Remote Controller (PAR-FL32MA;req.PAR-F 32MA-E) Wireless Signal Receiver PAR-FA32MA (for PAR-FL32MA-E) Lockdown Bracket for Hand-held Controller (RCMKP1CB) 13 Mitsubishi Electric US, Inc.

SPECIFICATIONS: ** & SUZ-KA15NA Cooling* Rated Capacity....14,1 Btu/h Capacity Range...3,8-17, Btu/h SEER... 15.5 Total Input....1,17 W Heating at 47 F* Rated Capacity....18, Btu/h Capacity Range...4,8-21,1 Btu/h HSPF... 1. Total Input....1,5 W Heating at 17 F* Rated Capacity....11,9 Btu/h Rated Total Input...1, W Maximum Capacity**...11,9 Btu/h Maximum Total Input...1,65 W * Rating Conditions per AHRI Standard Cooling Indoor: 8º F (27º C) DB / 67º F (19º C) WB Cooling Outdoor: 95º F (35º C) DB / 75º F (24º C) WB Heating at 47ºF Indoor: 7º F (21º C) DB / 6º F (16º C) WB Heating at 47ºF Outdoor: 47º F (8º C) DB / 43º F (6º C) WB Heating at 17º F Indoor: 7º F (21º C) DB / 6º F (16º C) WB Heating at 17º F Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB ** Maximum Capacity is at full speed and performance for INVERTER-driven System. Electrical Requirements Power Supply...8 / 2V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size.... 15 A OPERATING CONDITIONS Cooling Heating Maximum Minimum Maximum Minimum Indoor Intake Air Temp. 9 F (32 C) DB 73 F (23 C) WB 67 F (19 C) DB 57 F (14 C) WB 8 F (27 C) DB 67 F (19 C) WB 7 F (21 C) DB 6 F (16 C) WB Outdoor Intake Air Temp. 115 F (46 C) DB 14 F (-1 C) DB 75 F (24 C) DB 65 F (18 C) WB -4 F (- C) DB -5 F (-21 C) WB Voltage Indoor - Outdoor S1-S2...AC 8 / 2V Indoor - Outdoor S2-S3...DC ±24V Indoor Unit MCA...1 A Blower Type x Quantity....Sirocco Fan x 3 Blower Motor Type... Direct-driven DC Brushless Motor Blower Motor Output....96 W Blower Motor (ECM)....74 F.L.A. Airflow (Lo - Med - Hi).... 353-441 - 529 Dry CFM 317-396 - 476 Wet CFM Air Filter...Polypropylene Honeycomb External Static Pressure....2 -.6 -.14 -."WG Sound Pressure Level (Lo - Med - Hi)... - 34-37 db(a) DIMENSIONS UNIT INCHES / MM W 39 / 99 D 27-9/16 / 7 H 7-7/8 / Weight....54 lbs. / 24 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D.....1-1/4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven Twin Rotary MCA...12 A MOCP....15 A Fan Motor (ECM)...5 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...51 db(a) DIMENSIONS INCHES / MM W 31-1/2 / 8 D 11-1/4 / 285 H 21-5/8 / 55 Weight...8 lbs. / 36 kg External Finish... Munsell No. 3Y 7.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...1/2" / 12.7 mm Liquid Side....1/4" / 6.35 mm Max. Refrigerant Pipe Length.... 65' / 19 m Max. Refrigerant Pipe Height Difference... ' / 12 m Connection Method...Flared Notes: 13 Mitsubishi Electric US, Inc.

SEZ-KD15NA** INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW CHARTS (External static pressure.2[in.wg](5pa)) 8/2V 6Hz (External static pressure.6[in.wg](15pa)) 8/2V 6Hz 5 [.] [.8] 1 [.4] [.8] 1 [.4] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [5] [565] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [5] [565] (External static pressure.14[in.wg](35pa)) 8/2V 6Hz 8 [.32] 7 [.28] 6 [.24] 5 [.] [.8] 1 [.4] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [5] [565] (External static pressure.[in.wg](5pa)) 8/2V 6Hz 8 [.32] 7 [.28] 6 [.24] 5 [.] [.8] 1 [.4] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [5] [565] 13 Mitsubishi Electric US, Inc.

DIMENSIONS: ** 159(6-9/32) 15(19/32) 2XE- ø2.9(1/8) 345(13-19/32) (Emergency draining) Suspension bolt hole 4-14X(9/16X1-3/16) Slot L- ø2.9(1/8) (13/16) 12(1/2) 37(1-15/32) 1(3-15/16) 157.5 (6-7/32) 37(1-15/32) Unit : mm(in.) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) Air outlet Air inlet 25(1) A N B (Suspension bolt pitch) C M 88(3-15/32) 88(3-15/32) H 57(2-1/4) 1(3-15/16)XJ=K 1(3-15/16) 15(Duct) (5-29/32) (13/16) (1-3/16) 1 25(1) (3-15/16) 57(2-1/4) 116 (4-19/32) 2X2- ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) 49 625(Suspension bolt pitch) (1-15/16) (24-5/8) 1(13/32) 7 (2-25/32) 27(1-21/32) 2 Refrigerant piping flare connection (liquid) 7(27-9/16) 677(26-21/32) Control box 12(4-1/32) 17(6-23/32) 9 (3-9/16) (7-7/8) Knockout hole ø 27(1-3/32) (Indoor/outdoor connecting line) Knockout hole ø 27(1-3/32) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) (Spontaneous draining) (13/16) 12(1/2) Air filter Note2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) (17-23/32) 45 777 (17-23/32) (-19/32) 175±5(6-29/32 ±7/32) (Actual length) Access door (11-13/16) More than Required space for service and maintenance Less than (11-13/16) Less than 55 (21-21/32) More than 1 (13/32) Drain hose (I.D. ø32(1-1/4)) <accessory> More than (13/16) Ceiling surface Access door Make the access door at the appointed position properly for service maintenance. Model A B C D SEZ-KD9NA4** 7 752 798 66 (27-9/16) (29-5/8) (31-7/16) (26) SEZ-KD12NA4** 9 952 998 86 (35-7/16) (37-1/2) (39-5/16) (33-7/8) ** F G 6 8 (23-5/8) (31-1/2) H 66 (26) 8 1 86 (31-1/2) (39-3/8) (33-7/8) SEZ-KD18NA4** 11 1152 1198 16 1 1 16 (43-5/16) (45-3/8) (47-3/16) (41-3/4) 11 (39-3/8) (47-1/4) (41-3/4) 9 Note1.Use M1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for ** model,which has 3 fans. SEZ-KD9,12NA4** models have 2 fans. SEZ-KD18NA4** models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 7 9 J 5 7 K 5 (19-11/16) 7 (27-9/16) 9 (35-7/16) L 16 24 M 839 (33-1/16) 139 (-29/32) 1239 (48-25/32) N 79 (31-1/8) 99 (39) 119 (46-7/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.7(1/2) 13 Mitsubishi Electric US, Inc.

DIMENSIONS: SUZ-KA15NA FORM# ** & SUZ-KA15NA - 1311 13 Mitsubishi Electric US, Inc. 13 Satellite Boulevard Suwanee, GA 24 Tele: 678-376-29 Fax: 8-889-994 Toll Free: 8-433-4822 www.mehvac.com