Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Similar documents
Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

LASER SAFETY BARRIER

LASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES

*For inquiries and questions about lasers, see the Yellow-Page.

Cooled Butterfly 980nm Pump Laser Module

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

Important Safety Notice

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

A. Administrative. B. Labeling and Posting. C. Control Measures. Laser Safety Self-Audit Checklist. Building Room Principal Investigator Date

NX7363JB-BC. Data Sheet R08DS0009EJ0200 Rev.2.00 LASER DIODE. Sep 19, 2010 DESCRIPTION FEATURES

Laser Safety Self-Audit Checklist

SYNRAD Laser Safety 101

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Product Specification

NX7535 Series DESCRIPTION NX7535AN-AA FEATURES NX7535BN-AA

NEED FOR LASER SAFETY

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

PENALTIES. All imported products are required to meet the same standards as domestic goods. National Safety Requirements. Customs Requirements

LASER DIODE NX7637BF-AA

Laser Safety Citations

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

CATALOGUE LASER POINTERS

NX8663JB-BC. Data Sheet DESCRIPTION FEATURES R08DS0063EJ0100 LASER DIODE. Rev.1.00

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

INTERNATIONAL STANDARD

Content. Laser physics Laser treatment parameters Laser safety. by Fotona d.o.o., 2017

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

64 Max IR Thermometer

Laser Safety Per Söderberg

safety & regulatory information

OWNERS MANUAL OPERATION GUIDE

Contains Nonbinding Recommendations. Draft Not for Implementation

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

Diode-Pumped Solid-State Blue Lasers

All pulses < 4Hz (>0.25sec) BLUE>400mW. As measured under IEC measurement conditions for classification.

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Copyright 2017 by Lasermate Group, Inc.. All rights reserved.

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

This document is a preview generated by EVS

Product Specification

COMPACTNESS 34.1 PERFORMANCE ANTICIPATION

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

Rice University Laser Safety Manual

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

Wideband Optical Couplers

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

G4 Pulsed Fiber Laser

COMPACTNESS 34.1 PERFORMANCE ANTICIPATION

GPON OLT Optical Transceiver SFP Module RTXM RTXM Features

Clearlite Photonic Fibers

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

American National Standard for Safe Use of Lasers

Laser Safety Management

NLC 210 Air-Cooled Argon-ion Laser

Söderberg, PG Sid. 1(8) Laser Safety. Per Söderberg Gullstrand lab, Ophthalmology, Dept. of Neuroscience Uppsala university Uppsala, Sweden

University of North Florida Laser Safety Manual. Environmental Health and Safety Department

Product Specification

Information for Proper Posting & Laser Area Sign Templates

Why is Laser Safety Important Laser usage is growing rapidly e.g. laser points, CD/DVD, industrial applications Heavy use now in laboratories for

Class 1 laser beam sensor safe for your eyes


Agilent 81662A and Agilent 81663A DFB Laser Source Modules. User s Guide

Laser Use at Subaru Telescope (NAOJ) Laser Safety Policy

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

Rutgers Environmental Health and Safety (REHS)

Four channel video link For low cost video transmission

Laser Safety Program

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

NLC C61 Air-Cooled Argon-ion Laser

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

PONA Rack Mounted Erbium Doped Fiber Amplifier. User s Manual r001 August 30, W. Chestnut St Alhambra, CA 91803

G4 Pulsed Fiber Laser

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

Class 1 laser beam sensor safe for your eyes

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

62 MAX/62 MAX + Infrared Thermometer

Certified Laser Safety Officer. Exam Reference Guide

3kW 6kW, QUBE Fiber Lasers

Recommended Work Area Controls

Inspection Detail. General Questions for Laser Labs

INTERNATIONAL STANDARD

Laser Safety Training

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Electro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC

Set-Up Procedures. Before You Start

1.25G SFP transceiver with DDM function. RTXM191-xxx (DDM) Features

Why is Laser Safety Important Laser usage is growing rapidly Industrial applications Heavy use now in laboratories for research, analysis Many

Transcription:

Description The DFB-1XXX-BF-XX-CW-Fx-Hx-N127 series of Multi-Quantum Well (MQW) Distributed Feedback (DFB) lasers have been designed specifically to satisfy the requirements of the sensor application. The devices feature high output power and wide operating temperature range. Their 14-pin butterfly packages are either pincompatible with standard SONET OC-48 devices or can be floating from the metal house. Features Advanced Multiple Quantum Well (MQW) Distributed Feedback (DFB) Laser Design High-output power Industry-standard 14-pin Butterfly package Option of SMF-28 Fiber Pigtail or PM fiber Applications Sensor development Methane Gas detection External modulation 1

Absolute Maximum Ratings Parameter Symbol Condition Min Max Unit Operating Case Temperature T c I=I op -10 50 C Storage Temperature T stg -- -40 85 C Laser Forward Current I f -- -- 120 ma Laser Reverse Bias V r -- -- 2 V Photodiode Reverse Bias V rpd -- -- 10 V TEC Current I TEC -10 C < T c < 50 C, -- 1.5 A T op=25 C, I f=100 ma Electrical and Optical Characteristics Parameters are tested at 25 C unless otherwise noted. Parameter Symbol Min Typ Max Unit Test Conditions Operating Case T c -10 -- 50 C Temperature Laser Set temperature T L 10 25 40 C Optical Output Power* P o 6 -- -- mw CW, Threshold Current I th -- -- 50 ma T L=25 C Forward Voltage V F -- -- 2 V P o=p L Operating Current Iop -- -- 120 ma P o=p L, T L=25 C Center Wavelength* c Refer to order option nm P o=p L, CW, 10 C T L 40 C Center Wavelength c -0.1 -- 0.1 nm P o=p L, CW, 10 C T L 40 C Tolerance Spectral Linewidth -- -- 10 MHz P o=p L, T L=25 C Side-mode Suppression SMSR 35 -- -- db P o=p L Ratio Monitor Current I mon 10 -- 150 A/mW V rpd=5 V Monitor Dark Current I D -- -- 200 na V rpd=5 V Thermistor Resistance R t 9.5 -- 10.5 k T=25 C Thermistor B Constant B -- 3900 -- K T=25 C TEC Current I C -- -- 1.5 A C TEC Voltage V C -- -- 2.0 V C * See Ordering Options and contact AOI marketing for availability. 2

Outline Diagram Dimensions are in millimeters For ordering option H1 (Floating LD design) 3

For ordering option H2 (Negative Bias Design, Case GRD connected to LD Anode) 4

Ordering Options DFB-1XXX-BF-XX-CW-Fx-Hx-N127 BF House Option : H1 = Floating LD design H2 = Negative Bias Design Fiber Pigtail Option Option Fiber Length (mm) Connector Notes F1 PM 1200+100 FC/APC F2 SMF 1200+100 FC/APC Output Power Option Option Output Power (mw) 06 6 08 8 10 10 15 15 20 20 25 25 Notes Option Wavelength Option Center Wavelength (nm) Max Output Power (mw) Notes 1653 1653.7 12 CH 4 1651 1651.0 8 CH 4 1631 1631.46 8 1630 1630.98 8 1625 1625.0 10 1623 1623.5 8 1578 1578.0 10 CO 2 1531 1531.7 20 NH 3 1512 1512.0 20 NH 3 1392 1392.0 20 H 2O 1312 1312.0 30 HF 1580 1580.0 10 H 2S, CO 1590 1590.0 10 H 2S Note 1: Please check with AOI marketing for the availability of the wavelength before order. Note 2: Other wavelength may be possible for a different absorption line, Please check with AOI market department for the availability. 5

Safety Information All versions of this laser are Class 1M laser products per IEC 1 /EN 2 60825-1:2001-08. Users should observe safety precautions such as those recommended by ANSI 3 Z136.1-2000, ANSI Z36.2-1997 and IEC 60825-1:2001-08. Notes about Laser Safety Class: The Food and Drug Administration's Center for Devices and Radiological Health (FDA/CDRH) in the USA has decided to harmonize their requirements with 21 CFR 1040.10 and 1040.11 with the IEC/EN 60825-1 and IEC/EN 60601-2-22 standards. This process has not yet happened and in the interim, the CDRH agency has released 'Laser Notice No.50' to reduce the regulatory burden. This notice allows IEC/EN classification and labeling of lasers within the USA. IEC 1 /EN 2 60825-1 Laser Class Class 1M: laser is safe for all conditions of use except when passed through magnifying optics such as microscopes and telescopes. Class 1M lasers produce large-diameter beams, or beams that are divergent. The MPE for a Class 1M laser cannot normally be exceeded unless focusing or imaging optics are used to narrow the beam. If the beam is refocused, the hazard of Class 1M lasers may be increased and the product class may be changed. A laser can be classified as Class 1M if the total output power is below (IEC/EN) class 3B but the power that can pass through the pupil of the eye is within Class 1. FDA Laser Class Class IIIB: moderate power lasers (cw: 5-500 mw, pulsed: 10 J/cm 2 or the diffuse reflection limit, whichever is lower). In general Class IIIB lasers will not be a fire hazard, nor are they generally capable of producing a hazardous diffuse reflection. Specific controls are recommended. This product does not conform to 21 CFR 1040.10 and 1040.11. Consequently, this laser module is only intended for use as a component by manufacturers of electronic products and equipment. Wavelength =1270 1610 nm Maximum Power = 75mW Single-mode fiber pigtail Fiber Numerical Aperture = 0.14 Labeling is not affixed to the laser module due to size constraints; rather, labeling is placed on the outside of the shipping box. This product is not shipped with a power supply. Caution: use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. (1) IEC is a registered trademark of the International Electrotechnical Commission (2) Within Europe the IEC standard has been adopted as a European Normative standard known as EN 60825, and each European country will have its own version of this standard, for example, the British Standards version known as BS EN 60825. There can be small differences between the different countries versions of EN 60825, and these are in part caused by the process of translating the standard into the native language of that country. (3) ANSI is a registered trademark of the American National Standards Institute. 6