S F IT 6" / 8"HES. Quick Installation Guide. franklinwater.eu

Similar documents
EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Engineering Guideline. pac- Carriers Type Universal

Instructions for the fan motor control system, SILVER C

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

GRUNDFOS INSTRUCTIONS. Dedicated Controls. Service instructions

Intelligent Security & Fire Ltd

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Sequence of operation

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

Insulation fault evaluator EDS460-DG

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Tri-Stack Smart System

RES-210 (-211, -220, -221) / RES-420

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Instructions for the fan motor control system with integrated wiring terminals SILVER C

FIL-SPL Flow-through heater for central heating USER MANUAL

1.7. Insulation fault evaluators EDS460/490 EDS461/491

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

User Manual. Dryer Controller M720

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Multi-Gas-Controller MGC2

FC700A Fire detection control unit

M2500 Engine Controller Installation Manual

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

EasyTronic III MANUAL SERVICE

Dryer Controller M720

PowerLogic ION Setup Meter Configuration Software Configuration Guide

GLOBAL. InstallatIon & operation manual

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Micro-VPAC IIT LSC - Lift Station Controller. User Manual. Version 1.0.2

ACS-30-EU-VIA-DU-20-MOD

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

N M AirControl AHU. Control manual

Installation, Operating and Maintenance Manual

RESISTRON. Replacing RES-102/RES-420. Replacement Instructions. Comparison of RES-102 / RES-420. Dimensions. Temperature indication (actual value)

QS941A Controller User Interface

Operation Manual. Programmable Logic Controller

Dryer Master DM510 Commissioning Guide

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

eed quality electronic design USER s MANUAL

S/601 Controller Installation Manual

DC 60 & DM 60 displays

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

PLW PLW TOP LOAD. PV Hot Water Controller. PV Solar Hot Water Controller PLASMATRONICS. Manual. Read this before installing. Rev. U3.

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Gas Controller Module GC-06

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

INSTALLATION INSTRUCTIONS

Installation manual Washer extractor

Two-Channel Gas Controller

REPEATER FS5200R INSTRUCTION MANUAL

Danfoss gas detection Controller unit

Danfoss gas detection units

Rev 7 06-APR MultiFlex Condensing Unit Board (CUB-II and CUB-TD) Installation and Operation Manual

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

UniPOS Wireless Fire Alarm Control Panel VIT 01 WIRELESS FIRE ALARM CONTROL PANEL VIT01 INSTRUCTION MANUAL

Humidity Controller Specification and Installation Instructions. Model HRO20

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Inverter scroll compressors VZH

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Fire control panels FC360

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

DEIF A/S. Operator s Manual. Multi-line 2/version 2-GS E (UK) SW version 2.4X.X. Display readings. Push-button functions.

Fire control panels FC726 FC726-XA

Remote alarm indicator and test combination MK2430

Built-on speed controller for GMPM plug fan with permanent magnet motor

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Memcom Emergency Telephone

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Carbon Monoxide Transmitter

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

FLÄkT WOOdS BuILT-ON FrEQuENCY CONVErTEr CENTRIFLOW 3D PLUG FAN WITH PERMANENT MAGNET AND ASYNCHRONOUS MOTOR

M1000 Alarm Annunciator

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

Instructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013

Pioneer-R16 Gas Monitor Operator s Manual

Manual & Technical Documentation V1.1

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

XC1008D -XC1011D- XC1015D and VGC810

Transcription:

GB D S F IT 6" / 8"HES Quick Installation Guide franklinwater.eu

Summary Page English 5-19 Deutsch 25-39 Svenska 44-60 French 63-81 Italian 84-101

GB 6" / 8"HES Quick Installation Guide franklinwater.eu

Summary Page Control modes and necessary sensor technologies 5 Battery Installation Procedure IP66 / IP21 5 Connection Description 6"/ 8" HES Sytem Standard 6 System and Connection Description 6" HES solar 7 Connections Motor and Option cards 8 6"/8" System Performance Data 400V-50Hz 9 Keypad button Overview 10 Start-Up-Wizard 10 Basic Con guration 11 / 12 Con guration 13 / 14 Con guration h 15 Con guration P 16 Direct Mode (DM) 17 Manual Mode (MM) 17 Display Messages 18 Con guration S (Solar) 19 Additional safety instructions System can automatically restart (Solar) - the appropiate safety precautions should be taken. See page 19 DANGER 4

Control modes and necessary sensor technologies Process reference Control reference Flow meter Pressure sensor Level sensor PT100 sensor & Drive slot card Flow switch (digital) - Flow No (Optional) mandatory Optional P mandatory mandatory H mandatory mandatory P - pressure No (Optional) Yes* mandatory Optional Q mandatory mandatory H mandatory mandatory H - level No (Optional) Yes* mandatory Optional Q mandatory mandatory P mandatory mandatory Direct Mode No Yes** No No Optional No Manual Mode No Yes* Solar No Yes* mandatory *please consult Franklin Electric ** need to be evaluated to PLC Battery Installation Procedure IP66 2 1 1 2 Battery Installation Procedure IP21 5

Connections 6" / 8" HES Standard System Standard I/O Terminal Signal 1 +10 Vref Reference output Analogue input, 2 AI1+ voltage or current Control Reference: AI1, Terminals 2(+), 3(GND) 3 AI1- Analogue input (Connection depending Default setting [V] common on settings) Analogue input, 4 AI2+ voltage or current Analogue input 5 AI2- common 6 24V out 24V aux. voltage 7 GND I/O ground Fig. 1: Input/Output Terminals Process Reference: AI2, Terminals 4(+), 5(GND) Default setting [ma] 8 DI1 Digital input 1 Start/Stop: DI1, Terminals 6(+24V), 8(DI1) 9 DI2 Digital input 2 External Fault: DI2, Terminals 6(+24V), 9(DI2) 10 DI3 Digital input 3 Manual Operation: DI3, Terminals 6(+24V), 10(DI3) 11 CM Common for DI1 - DI6* 12 24V out 24V aux. voltage 13 GND I/O ground 14 DI4 Digital input 4 Set Point - : DI4, Terminals 6(+24V), 14(DI4) 15 DI5 Digital input 5 Set Point + : DI5, Terminals 6(+24V), 15(DI5) 16 DI6 Digital input 6 Reset: DI6, Terminals 6(+24V), 16(DI6) 17 CM Common for DI1 - DI6* Analogue output, 18 AO1+ voltage or current Analogue output 19 AO-/GND common 30 +24V in 24V aux. input voltage A RS485 Serial bus, negative B RS485 Serial bus, positive * Can be isolated from ground, see chapter 5.1.6. 2- wire Sensor Supply + 24V (Terminal 6) Common - AI+ (Terminal 2/4*) 3- wire Sensor Common - Common(Terminal 7) AI- (Terminal 3/5*) 4- wire Sensor Fig. 1.1 : Sensor connection * depending on Reference AI - (Terminal 3/5*) Common(Terminal 7) Supply + 24V (Terminal 6) 0/4-20mA AI+ (Terminal 2/4*) Supply + 24V (Terminal 6) Common Common(Terminal 7) 0/4-20mA+ AI + (Terminal 2/4*) 0/4-20mA - AI- (Terminal 3/5*) Form standard I/O Relays From term. #6 RUN From term. #13 Terminal 21 RO1/1 22 RO1/2 23 RO1/3 24 RO2/1 25 RO2/2 26 RO2/3 Signal Relay output 1 Relay output 2 Operation: RO1, Terminals 22(+24V), 23 Warning/Fault: RO2, Terminals 25(+24V), 24 Fig. 2: Relais Output Connection IP21 IP66 AI1 AI2 A0 AI1 AI2 A0 Fig. 3: Analog Input/Output Signal Selection IP21 IP66 Fig. 4: Digital Input Selection 6

6" HES Solar System DC Power Solar PV Array G IP 66 HES Drive Solar B B Heat Sink Flow Switch (required for operation): 226 019 101 D Filter C Derating 40 C - 100% 50 C - 75% 60 C - 50% DC Disconnect optional part A Control Switch Full F Pump/Motor Control Switch Empty E H Alternate AC Power (Optional) 2 Level Control Switch Operation optional parts: 308 170 209 Connections 6" HES Solar System Standard I/O Terminal Signal 1 +10 Vref Reference output Analogue input, 2 AI1+ voltage or current Analogue input 3 AI1- common Analogue input, 4 AI2+ voltage or current Analogue input 5 AI2- common 6 24V out 24V aux. voltage 7 GND I/O ground 8 DI1 Digital input 1 Start/Stop: DI1, Terminals 6(+24V), 8(DI1) 9 DI2 Digital input 2 Flow Switch: DI2, Terminals 6(+24V), 9(DI2) 10 DI3 Digital input 3 Manual Operation: DI3, Terminals 6(+24V), 10(DI3) 11 CM Common for DI1 - DI6* 12 24V out 24V aux. voltage 13 GND I/O ground 14 DI4 Digital input 4 Control Switch Empty DI4, Terminals 6(+24V), 14(DI4) 15 DI5 Digital input 5 Control Switch Full DI5, Terminals 6(+24V), 15(DI5) 16 DI6 Digital input 6 Reset: DI6, Terminals 6(+24V), 16(DI6) 17 CM Common for DI1 - DI6* Analogue output, 18 AO1+ voltage or current Analogue output 19 AO-/GND common 30 +24V in 24V aux. input voltage A RS485 Serial bus, negative B RS485 Serial bus, positive * Can be isolated from ground, see chapter 5.1.6. Fig. 5: Input/Output Terminals 7

Connections Motor and Option cards L1 U/T1 U1 U2 U ~ _ du L2 V1 dt V/T2 V2 V M L3 W/T3 W1 W2 W 3~ PE PE PE PE PE ~ _ Color code FE Motor Short Lead: U - brown V - grey W - black Fig. 6: Supply and motor connection Color code FE PT100 Lead: 1 2 3 1 - black 2 - blue 3 - brown Fig. 7: PT100 card (left slot) Fig. 8: PT100 connection Jumper X2 Jumper X4 Fig. 9: OPTB1, 6 DI/DO card Fig. 10: OPT-B4, 1AI/2AO card 9 8 7 6 Red Yellow Green X6 X1 Bus Connector Jumper Interface Board - Connector word 1: motor current word 2: process value word 3: control value word 4: PT100 temperature word 5: motor speed (RPM) word 6: process reference word 7: relay output word 8: output frequency Fig. 11: OPTE5, Pro bus card (right slot) 8

6" HES System Performance Data 400V-50Hz 400V/50Hz 308 010 X16 P N [kw] Thrust F [kn] n N [min -1 ] I N [A] I A / I * N [A] [%] cos [%] T N [Nm] 4 15,5 3000 8 1 88 0,95 12,9 1 5,5 15,5 3000 10 1 89 0,95 17,5 1 T A / T N * [Nm] 7,5 15,5 3000 13 1 89,5 0,95 23,8 1 308 014 X23 9,3 15,5 3000 18 1 91,5 0,95 29,6 1 11 15,5 3000 20 1 92 0,95 35 1 13 15,5 3000 23 1 92,5 0,95 41,5 1 308 014 X38 15 15,5 3000 26 1 92,5 0,95 46,1 1 18,5 15,5 3000 32 1 92 0,95 59 1 22 27,5 3000 39 1 93 0,95 70 1 308 016 X61 26 27,5 3000 46 1 92,5 0,95 82,6 1 30 27,5 3000 54 1 91,5 0,95 95,5 1 308 016 X87 37 27,5 3000 72 1 90 0,95 117,8 1 8" HES System Performance Data 400V-50Hz 400V/50Hz 308 014 X01 P [kw] Thrust F [kn] n N [min -1 ] I N [A] I A / I * N [A] [%] cos [%] T N [Nm] 45 45 3000 74 1 93,3 0,96 143 1 55 45 3000 91 1 93,3 0,96 175 1 67 45 3000 112 1 93 0,96 213 1 T A / T N * [Nm] 75 45 3000 128 1 92,5 0,96 239 1 75 45 3000 129 1 93,5 0,95 239 1 308 016 X01 83 45 3000 143 1 93,3 0,95 264 1 93 45 3000 162 1 93 0,95 296 1 100 45 3000 178 1 92,7 0,95 319 1 100 45 3000 176 1 94,2 0,94 319 1 308 017 X01 110 45 3000 193 1 94,2 0,94 350 1 130 45 3000 229 1 94 0,94 413 1 150 45 3000 270 1 93,4 0,94 477 1 Performance data are based on measurements with Franklin Electric original equipment! 9

Keypad buttons Overview Move backward in menu Exit edit mode Reset faults with long press Scroll menu up Increase value Move cursor left Move cursor right Stop button Scroll menu down Decrease value Start button Enter active level/item Start-Up-Wizard RUN READY I / O Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT100 50.0m3h 49.5m3h 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 0.0[-] 0.0[-] 0.0[-] Monitor M 2.1 Multimonitor Trend Curve (12) Basic (12) Monitor M 2.1 Fieldbus Data (20) Trend Curve (4) Basic (1) WIZARD 1171 M 2.10.1 Startup wizard Startup wizard M 2.10.1 Activate Help Add to Favorites 10

Language Selection 802 English Daylight saving 2204 Russia US EU OFF Time 2201 09:14:11 Min: Max: Year 2203 2017 Min: Max: Date 2202 7.2. Min: Max: During the next steps please enter System Data. Output Filter 1810 du/dt Filter * * PT100 installed 1834 Yes No STOP Not RDY I / O Please note, a PT100 sensor has to be used to measure Motor- Temperature, connected to OPT- BH, terminals 1, 2 and 3. Refere to Quick Installation Guide. next steps please enter Motor Nameplate Data. Motor Nom. Voltage 1812 500 V 400 V 230 V 220 V Nominal Amps 113 Min: 0.26A Max: 5.20A 1.90 A Motor Nom. Frequency 1813 100 Hz 120 Hz During the next steps please enter Duty Point Data. Duty Point Flow 1828 Min: 1.0m³/h Max: 500.0m³/h 75.0 m³/h * for other languages please contact Franklin Electric Europa GmbH ** is only shown and selectable if PT100 Option card is installed 11

Basic Con guration Duty Point Head 1829 Pump Install. Depth 1815 Casing Diameter 1816 90.0 m 50.0 m 300.0 mm Min: 1.0m Max: 1000m Min: 1.0m Max: 1000.0m See Fig.12 Min: 100.0mm Max: 1000.0mm Min. Water Colum 1818 Min: 0.5m Max: 200.0m 10.0 m See Fig.12 During the next steps please enter Process Data. Process Reference 1819 Q [m³/h] Page 13 h [m] P [bar] h P Page 14 Page 16 Direct Mode DM Page 17 Manual Mode MM Page 17 Solar S Page 19 Process Reference has to be connected to AI2, terminals 4(+) and 5(-). Control reference 1 has to be connected to AI1, terminals 2(+) and 3(-). Q, H Flow Inducer SLEEVE PUMP INSTALL. DEPTH Min. Water Column Level Probe Installation Depth Ø D Fig. 12 12

Process Reference 1830 Voltage 4...20mA 0...20mA Voltage Proc. Ref. End Scale 1034 Min: 0.00m3h Max: 600.0m3h 150.0 m3h ProcRefSetPntSource 332 Fieldbus Standard Please note, if AI2 is used as Voltage input, you have to set DIP- Switch AI2 to U. Refere to Quick Installation Guide. Control Reference 1831 2...10V 0...10V ProcRefSetPntSource 332 Fieldbus Standard Proc. Ref. Set Point 167 Min: 31.12m3h Max: 1000.0m3h 73.0 m3h Control Reference 1820 On Control Reference 1820 On Please note, an analog level meter or analog pressure sensor has to be used as Control Reference 1, connected to AI1, terminals 2(+) and 3(-). See Fig. 1, 1.1 without rotation will start. You can Stop-Button at any time. Having ready to start. RUN READY I / O Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT100 50.0m3h 49.5m3h 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 0.0[-] 0.0[-] 0.0 [-] 13

Con guration h[m] Ctrl. Ref. Signal 1822 h [m] P [bar] Control Reference 1832 2...10V 0...10V Current LPP Install. Depht 1888 Min: 0.1 m Max: 1000.0 m 20.0m Current If Control Reference Signal is ma, you have to set. DIP- Switch AI1 to I. Refer to Quick Installation Guide. Control Reference 1833 4...20mA 0...20mA Voltage See Fig. 3 LPP Max. Range 1887 Min: 0.1 m Max: 1000.0 m 10.0m Ctrl. Ref. Set Point 1823 Min: 0.0 m Max: 1000.0 m 0.0 m without rotating will start. You can Stop-Button at any time. Having ready to start. Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT100 50.0m3h 49.5m3h 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 10.0m 10.5m 25.0 m P[bar] Ctrl. Ref. Signal 1822 h [m] P [bar] Control Reference 1832 2...10V 0...10V Current Ctrl. Ref. End Scale 1836 Min: 1.0bar Max: 1000.0bar 25.0 bar Current If Control Reference Signal is ma, you have to set. DIP- Switch AI1 to I. Refer to Quick Installation Guide. Control Reference 1833 4...20mA 0...20mA Voltage See Fig. 3 Ctrl. Ref. Set Point 1823 Min: 0.5bar Max: 100.0bar 6.0 bar without rotating will start. You can Stop-Button at any time. Having ready to start. Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT100 50.0m3h 49.5m3h 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 6.0bar 4.5bar 25.0bar 14

Con guration h Process Ref. Signal 1830 LPP Install. Depth 1888 LPP Max. Range 1887 ProcRefSetPntSource 332 4...20mA 0...20mA Voltage 20.0m Min: 0.1 m Max: 1000.0m Min: 0.1 m Max: 1000.0 m 10.0m Fieldbus Standard Voltage Please note, if AI2 is used as Voltage input, you have to set DIP- Switch AI2 to U. Refere to Quick Installation Guide. Process Ref. Signal 1830 2...10V 0...10V ProcRefSetPntSource 332 Fieldbus Standard See Fig. 3 Proc.Ref.Set Point 167 Min: 0.00m Max: 40.00m See Fig. 1, 1.1 15.00 m be used as Control Reference, connected to AI1, terminals 2(+) and 3(-). Current Control Reference 1832 2...10V 0...10V Current Ctrl. Ref. End Scale 1836 150.0 m3h Min: 1.0 m3h Max: 1000.0 m3h is ma, you have to set. DIP- Switch AI1 to I. Refer to Quick Installation Guide. Control Reference 1833 4...20mA 0...20mA See Fig. 3 Ctrl. Ref. Set Point 1823 Min: 31.1m3h Max: 150.0m3h 31.1m3h without rotating will start. You can Stop-Button at any time. Having ready to start. RUN READY I / O Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2100rpm Setpoint Feedback PT100 15.0m 9.0m 23.5 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 31.1m3h 45.0m3h 150.0m3h 15

Process Ref. Signal 1830 Proc. Ref. End Scale 1034 ProcRefSetPntSource 332 4...20mA 0...20mA Voltage Min: 0.0 bar Max: 600.0 bar 16.0 bar Fieldbus Standard Voltage Please note, if AI2 is used as Voltage input, you have to set DIP- Switch AI2 to U. Refere to Quick Installation Guide. Process Ref. Signal 1831 2...10V 0...10V ProcRefSetPntSource 332 Fieldbus Standard See Fig. 3 Proc.Ref.Set Point 167 Min: 0.0 bar Max: 40.0 bar 8.0 bar be used as Control Reference 1, connected to AI1, terminals 2(+) and 3(-). Control Reference 1832 2...10V 0...10V Current Ctrl. Ref. End Scale 1836 100.0 m3h Min: 1.0 m3h Max: 1000.0 m3h See Fig. 1, 1.1 Current is ma, you have to set. DIP- Switch AI1 to C. Refer to Quick Installation Guide. Cotrol Reference 1833 4...20mA 0...20mA See Fig. 3 Ctrl. Ref. Set Point 1823 Min: 31.1 m3h Max: 100.0 m3h 31.1 m3h without rotating will start. You can Stop-Button at any time. Having ready to start. RUN READY I / O Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT100 8.0bar 6.5bar 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 31.1m3h 45.0m3h 100.0m3h 16

ProcRefSetPntSource 332 Fieldbus Standard without rotating will start. You can Stop-Button at any time. Having ready to start. RUN READY I / O Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT100 89.0 % 88.9 % 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 0.0 [-] 0.0 [-] 0.0 [-] ProcRefSetPntSource 332 Fieldbus Standard If Process Reference has to be connected to AI2, terminals 4 (+) and 5(-). Process Ref. Signal 1830 4...20mA 0...20mA Voltage Voltage Please note, if AI2 is used as Voltage input, you have to set DIP- Switch AI2 to U. Refere to Quick Installation Guide. Process Ref. Signal 1831 2...10V 0...10V See Fig. 3 Start/Stop has to be connected to terminal 6 (24V+) and DI1, terminal 8 or can be used by keypad (green/red push buttom). during operation by using DI4 (frequency DOWN) and DI5 (frequency UP) without rotating will start. You can Stop-Button at any time. Having ready to start. Frequency 105 Nominal Amps Output frequency 80.00 Hz Amps 23.0A 20.0A 89.80Hz PT100 23.7 C 17

Display Messages Failure Messages RUN READY ALARM I / O STOP READY ALARM I / O RUN READY ALARM I / O RUN READY ALARM I / O Sleep Alarm Active Code: 81 Alarm Hold Code: 57 PT100 Temperature Alarm Active Code: 70 PT100 Temperature Alarm Active Code: 70 Control Reference Signal out of range. Device is sleeping. Remedy: Check that motor is connected to frequency converter and Run command will not be removed befor completion of Motor temperature critical. Device sleep imminent. Motor temperature critical. Device is sleeping. STOP READY ALARM I / O READY ALARM I / O STOP READY ALARM I / O READY ALARM I / O Sleep Alarm Active Code: 81 Sleep Alarm Active Code: 81 Sleep Alarm Active Code: 81 Sleep Alarm Active Code: 81 Process Reference Signal too low. Device is sleeping. Process Reference Set Point not reached for a period of time. Device is sleeping. Process Reference Signal not reached during a period of time. Control Reference Signal out of range. Device is sleeping. STOP READY ALARM I / O READY ALARM I / O Sleep Alarm Active Code: 81 Sleep Alarm Active Code: 81 Control Reference Signal out of range for several times. Level switch Empty and Full have not plausible switch settings. Warning Faults READY I / O READY I / O Current Limit 1081 Fault: Hold Code: 82 Next Start-Delay active. Please wait, drive will start automatically. Too high Process Refence at low speed for a period of time. Motorcurrent reached Current-Limit. Check Setting and Pump. 18

(Attention: During the next steps please enter Solar Panel Data. Panel Voc 1870 Min: 10.0V Max: 100.0V 37.0V Panels per Row 1871 Min: 1 Max: 50 21 During the next steps please enter control data. On Time 1464 09:00 1465 20:00 ProcRefSetPntSource 332 Fieldbus Min: 00:00 Max: 20:00 Min: 09:00 Max: 23:59 Standard DI 3 Bypass Solar 1894 Automatic Restart 1896 Yes Yes No No DI 3 Bypass Solar 1894 Yes No Automatic Restart 1896 Yes No Warning: By setting Automatic Restart to yes the motor will start automatically after sun is coming back. Please refer QIG for safety information. Level Switch 1892 One Level Switch Two Level Switches No Level Switch Level Switch 1893 Normal Open (NO) Normal Closed (NC) The Level Switch (Full) has to be connected to terminal 6 (24V+) and DI 5, terminal 15. See Fig. 5, page 7 Level Switch 1892 One Level Switch Two Level Switches No Level Switch Level Switch 1893 Normal Open (NO) Normal Closed (NC) The Level Switch (Full) has to be connected to terminal 6 (24V+) and DI 5, terminal 15. The Level Switch (Empty) has to be connected to terminal 6 (24V+) and DI 4, terminal 14. See Fig. 5, page 7 Level Switch 1892 One Level Switch Two Level Switches No Level Switch Warning: Without Level Switch there is risk to over flood the tank! A Flow Switch has to be connected to DI 2, terminal 6(24V+) and terminal 9. Refer to Quick Installation Guide. See Fig. 5, page 7 without rotating will start. You can Stop-Button at any time. Having ready to start. Frequency 105 Nominal Amps 100.00 Hz Amps 23.0A 21.9A Motor speed DC- link Voltage 2856 rpm 679 V 19

Notes 20

Notes 21

Franklin Electric Europa GmbH Rudolf-Diesel-Strasse 20 54516 Wittlich/Germany Tel.:+49 (0) 6571 / 105-0 Fax:+49 (0) 6571 / 105-520 info@franklinwater.eu 22