FieldServer Driver - Serial FS Notifier NCA

Similar documents
FST DFS Notifier Onyx 640

FieldServer Driver - Serial FS SBT-FSI (Siemens Building Technologies Foreign Systems Interface)

Driver Manual. FS (Notifier NFS-640 NFS-320 NFS2-640)

FS Mircom FX2000 Fire Alarm Panel

FieldServer FS Secutron

FieldServer FS Fike Cheetah

FS Fike Cheetah

FieldServer Driver - Serial FS Grinnell TFX Minerva

EIA-232D Protocol And Data Formats for the AFP-200 Fire Alarm Control Panel

FieldServer Driver - Serial FS McQuay Microtech Open Protocol

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Laptop / PC Programming Manual

Simplex Panel Interface Guide

FS Mircom PRO2000 Fire Alarm Panel

IntesisBox BACnet/IP Server - Notifier ID3000 series

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

Section 9 System Operation

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual

Section 8 System Operation

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

ECO N DATE DESCRIPTION OF CHANGE CHG

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap

Smoke Detector and Siren. Manual

FCD-wire Contents. List of Figures

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

Fire Command Keypad. XR5 User s Guide

TrueAlarm Fire Alarm Systems

The Protec driver connects to the Protec Fire Detection range of digital addressable fire control panels. Available for Commander and ObSys.

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

IRIS Touch Firmware Enhancements and Additions from Version to Version

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

HERCULES 6 GRAPHICS SYSTEM

F Technical Bulletin SC 370 SMART Modbus Interface

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

Modbus RTU RS485 Manual

Liquid Crystal Display LCD-80. Installation Manual. Document /9/02 Rev: D2 PN 15037:D2 ECN

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

COCB_ Circuit Breaker (2 state inputs/ 2 control inputs)

USER MANUAL FOR OPERATING SYSTEM

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

Ademco Vista Alarm Panel

P2267 NETWORK INTERFACE

Software Release M2.7 Summary for the Notifier AM2020/AFP1010 Fire / Security Control Panels, Including NOTI FIRE NET and Peripherals

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

4100 Programming Instructions-Ver. 8.01

FlameGard 5 UV/IR HART

SimpleComTools, LLC 1

Control/Communicator

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17

Ovation Alarm Management System

Advanced FireAlarm Panel 1-4Loop

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators reference guide

R Series Remote Annunciators and Expander Installation and Operation Guide

Addendum to the DVC/DAA Manual (52411) for H Manual Revisions

Operating Instructions MXL Multi-Line Keyboard/Display Panel

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Fire System Objects. Introduction Page *3. Engineering *17. Data Base Generation *43

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

FiRe mobile-2 Operation Manual

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

User manual. KNXgal. version

GPS Evaluation Kit EVA1037/1080

Platform Services BACnet Alarm Management

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

This technical update applies to Pro-Watch Software Release 3.5 and later.

intelligent fire alarm ID60series panels

Intelligent 2 & 4 Loop Fire Alarm Control Panels

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

Introduction. Introduction

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

Carbon Monoxide Transmitter

Alarms and Events. Defining Alarm Conditions. Database-Generated Alarms

VAC PLC. System Description

OJD ITB No Attachment E Duress Alarm Equipment Specifications

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm.

UniNet 2000 Specification Integrated Facilities Management Monitoring and Control Systems Version /12/2002

user manual Document No , Revision 03 November 2015

Configuration and Operation Manual for the Unipos

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

TOTALFLOW Technical Bulletin 139

POP_ Smoke Detector

Manage Alarms. Before You Begin. NTP-E57 Document Existing Provisioning CHAPTER

Intelligent Single Loop Fire Alarm Control Panel

Manage Alarms. Before You Begin CHAPTER

Transcription:

Driver Version: 1.00 Document Revision: 15 Description FieldServer Driver - Serial FS-8700-98 Notifier NCA The NCA (Network Control Annunciator) Serial driver allows the FieldServer to record data from Notifier NCA over RS-232. The FieldServer acts as a Passive Client receiving messages and recording the status of a Notifier NCA Panel. There is no active polling by this driver; the communications are one-way through the panel's printer port, however the driver can generate some system commands like Ack, Reset, Silence and Drill if the FieldServer is connected to the NCA through its CRT port. The panel MUST output messages in English. This driver is not capable of emulating a Notifier NCA panel and the very limited Server functionality has only been implemented to facilitate FieldServer s Quality Assurance program. The NCA controls all the devices (e.g. NFS-3030, NFS-640 panels) connected in NOTI*FIRE*NET 1 architecture. Each Fire Alarm Panel connected in NOTI*FIRE*NET architecture is considered as a Node. 240 Nodes can exist on one network. The main purpose of this driver is to record the status of Fire Alarm System detectors and Modules at every Node in Data Arrays - one Data Array per loop per Node. NCA interacts with other Fire Alarm Panels, records the status of all panels and sends the events to printer and CRT ports. FieldServer captures these events in text form, parses and stores them in Data Arrays. These Data Arrays can be controlled by third party tools. Since the FieldServer does not actively poll for data, the accuracy and timeliness of the data is limited to the frequency of update messages that the Notifier Fire Panel issues. The NCA can connect to additional NOTIFIER Fire Panels (with the proper network software), namely AFP-200, AFP-400, AFP-1010, AM2020, NFS-640, and NFS-3030. Note that when AFP200's and possibly AFP400's are networked they do not send the 'CLEARED' message for latched points via the NCA so it is not possible to detect cleared points unless a system reset is done. Please note that an NCA panel is theoretically capable of being configured with up to 321 180 points. Although the FieldServer is capable of addressing and accessing each of these addresses, the point limits purchased with the FieldServer prevent the entire database from being accessed in any one application. It is therefore strongly advisable to ensure that only the point addresses of interest are configured, and that the FieldServer is purchased with the correct point count. The types of Notifier messages supported by this driver are summarized later in this manual. In addition, a detailed table shows each type of NCA message the FieldServer recognizes and the effect that it has on the status of the points in the Data Array. 1 For more detail about NOTI*FIRE*NET architecture contact Notifier Canada Ltd. Page 1 of 7

Fieldserver Mode Nodes Comments Client 1 Each FieldServer port can connect to only 1 NCA panel Server 0 The NCA driver cannot be used as a Server. Formal Driver Type Serial Passive Client Compatibility Matrix FieldServer Model FS-x2010 FS-x2011 FS-x30 FS-x40 SlotServer Connection Information Connection type: Baud Rates: Data Bits: 8 (Device limitation, driver supports 7,8) Stop Bits: 1 (Device limitation, driver supports 1,2) Compatible with this driver RS-232 9600 (Device limitation, driver supports most standard baud rates) Parity: None (Device limitation, driver supports None, Even, Odd ) Multidrop Capability No Devices tested: Device NCA NFS-3030 NFS-640 Tested (FACTORY, SITE) Factory Factory Factory Page 2 of 7

Connection configurations The FieldServer is connected to the Notifier NCA Fire Panel as shown in the following connection drawing. Configure the Notifier NCA Fire Panel according to manufacturer s instructions. Page 3 of 7

Connection Notes The FieldServer can be connected to EITHER the TB8 (CRT port) or TB9 (Printer Port) If the FieldServer is connected to TB8, the port must be enabled and set to Not Supervised. If it is connected to TB9, then the Printer port must be enabled and set 80 columns, Not Supervised and the following Functions will not work, ACK, Signal Silence, System Reset, and Drill. Page 4 of 7

Communications functions - Supported functions at a glance: Message Types Supported This driver was designed to be connected to the Notifier NCA printer or CRT port, and listen for incoming messages. The panel's default setting for the printer port is off. To utilize this driver, the printer port must be enabled to 80-columns, unsupervised. The driver is capable of generating system commands (Ack, Reset, Silence and Drill) along with listening messages if the FieldServer connected to the CRT port of the NCA Panel. The primary purpose of this driver is to record the status of devices connected to the NCA system by interpreting the text messages sent to the printer or CRT port and to generate some system commands on the CRT port. Not all messages will be interpreted, as many messages do not directly pertain to device status, or are currently supported. The following subset of event messages is recognized: Active Events: FIRE ALARM TROUBLE PREALARM SECURITY ALARM SUPERVISORY DISABLED ACTIVE ON OFF A detailed mapping of message interaction System Trouble messages provided by Notifier at the time this driver was written is tabulated in the NCA Driver Manual. Any changes or additions by Notifier will not be reflected in this driver unless specifically revised. Zone Status: This driver will not record information about zone status that is incorporated with point status messages. A device can belong to multiple zones, however, only the primary zone is listed in the printer output. This severely limits the accuracy of zone data based on event generated messages, and therefore will not be recorded. Page 5 of 7

Panel Status: Data Array Mapping: The status of NCA devices will be recorded into a series of data arrays within the FieldServer, and is available for reading by any other connected device. The data from each loop will be recorded into a separate data array, and a single system array will record system troubles. The structure of the data arrays is provided below. Most of these arrays will only contain binary information to represent an active or inactive state. However, there could be multiple troubles associated with a single device. For each trouble message, the data array register corresponding to a particular device will be incremented as a counter and decremented when a trouble is cleared. Parameter Registers (float) {per loop} Fire Alarm 0-199 detectors 200-399 modules Trouble - Each point will increment/decrement the number of troubles recorded, system normal will reset the counter to zero 500-799 700-899 detectors modules PreAlarm 1000-1199 detectors 1200-1399 modules Security Alarm 1500-1699 detectors 1700-1899 modules Supervisory 2000-2199 detectors 2200-2399 modules Disabled 2500-2699 detectors 2700-2899 modules Active 3000-3199 detectors 3200-3399 modules ON/OFF 3500-3699 detectors 3700-3899 modules {system points only} System Troubles 0-100 Fire Alarm 101-196 Panel 197-200 Bell Trouble - Each point will increment/decrement the number of troubles recorded, system normal will reset the counter to zero 201-296 297-300 Panel Bell PreAlarm 301-396 Panel 397-400 Bell Security Alarm 401-496 Panel 497-500 Bell Supervisory 501-596 Panel 597-600 Bell Disabled 601-696 Panel 697-700 Bell Active 701-796 Panel 797-800 Bell Page 6 of 7

Driver Limitations & Exclusions Zone information will not be recorded. Synchronization between the NCA panel and the FieldServer can only occur if the FieldServer is reset while the panel is in SYSTEM NORMAL mode. The NCA menu function called Read Status will not be recorded as this information is not available at the printer/crt port The printer port must be enabled on the unit and set to 80 columns with NO supervision Any data related to non-event driven reports will not be recorded by the FieldServer This driver was written specifically for the following NCA firmware versions. Any changes or additions by Notifier will not be reflected in this driver unless specifically revised. A002.002.005/B002.002.005 This driver will not record information about zone status that is incorporated with point status messages. This driver is not designed for multi-dropped panels. There can only be one panel connected to any given FieldServer port. This driver records data as presented to the Printer/CRT port by the Notifier NCA, and can only be as accurate as this data. The driver can send Ack, Reset, Silence and Drill messages to the NCA Panel if the FieldServer is connected to the NCA Panel at the CRT port. Successful write message sent for functions such as Ack, Silence, Reset or Drill only mean that the message has been sent. The driver does not record whether the message was received or acted upon. Page 7 of 7