anti-condensation valve

Similar documents
CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

TS RD 7761 RD, 7761 RD

DISCALDIRT deaerator-dirt separator

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

Systems for central heating

heat interface units A BOILER WITHOUT A FLAME

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

geothermal march 2011

Mercury Mixing Kit (Code: ME1053)

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

SATK 30 heat interface unit

100% IRISH...make yours a Brightfire.

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Cast Iron Boilers. G Series ( kW)

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

INSTALLATION AND SERVICING

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

STREBEL S-CB + Cascade Kits

Wood Boiler Plumbing Schematics

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

FireFlexmaster. A Multi Fuel Flexible Chimney Liner 10 year Manufacturer Guarantee. 172 Ferry Lane, Stanley Wakefield, West Yorkshire, WF3 4LT

Thermostatic mixing valves with replaceable cartridge for centralized systems

INSTALLATION AND OPERATING INSTRUCTIONS

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

Product overview. the optimum components for every application

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Operating Instructions

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2

Installation and Servicing Instructions. Alpha FlowSmart

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

GESTRA. Product Overview. The optimum components for every application

MULBERRY STOVES. cast a warm eye on life

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS

High quality boiler stoves and fireplace inserts

GESTRA. Product Overview. The optimum components for every application

Hoval Cosmo Combination boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 100 to 1450kW.

FOR INSTALLING AND USING

BIOMASS BOILER DUAL THERM

THE MUCH WENLOCK. Installation Instructions for Freestanding Much Wenlock Stove with Boiler

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Installation, operation and care Firewood boiler Vedolux 40 UB

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

FLUIDIZED BED BOILERS

HIGHLANDER Wood and Multi-fuel Stoves

Stored Water District Heating Interface Units. Heat Interface Units

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

Table 1: Hot water energy requirements

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

Providing sustainable energy solutions worldwide. CTC heating boilers modern technology, efficient heating

VAILLANT SPARE PART CATALOGUE

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

INSTALLATION AND OPERATING INSTRUCTIONS

charnwood I S L A N D Operating & Installation Instructions

CHARNWOOD COUNTRY 6 FT

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

gas condensing combi boiler

User Manual. PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) Fax +44. (0)

WGO, WTGO and SGO-W. Maintenance and Service Guide. eference, ence, leave this manual with other boiler instructions. For future e refer

Aquaflam Wood boiler stoves and fireplace inserts

Combustion hot flew gases passing chamber

Fire Chief Wood/Coal Burning Furnaces

HYBRID SERIES FURNACES. napoleonheatingandcooling.com

Thermostatic mixing valves with interchangeable cartridges

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

Transcription:

anti-condensation valve

Dimensions B C B Function The ltecnic anti-condensation valve connects between a biomass burning boiler and a direct or indirect heating system or domestic hot water system. It automatically controls the return temperature to the boiler to avoid condensation, by means of an integral thermostatic sensor. Keeping the boiler at a high temperature prevents condensation forming from the water vapour contained in the flue gases. It can be used on central biomass boilers or residential biomass burners such as fireplace heating systems and solid fuel stoves and cookers The anti-condensation valve gives the boiler a longer life and ensures greater efficiency. Design ulti-functional Body The compact brass single body casting houses the thermostatic sensor and temperature gauge pockets enables immediate installation of the unit, either on the right or left of the biomass boiler, respecting the flow directions as shown. The brass body prevents the formation of ferrous residues in the system, thereby helping to prolong the life of the boiler. nti-condensation valve nti-condensation valve incorporates a thermostatic sensor to control the temperature of water returning to the boiler, preventing the formation of condensation. The sensor has been specifically designed to be removed from the valve body for maintenance, re-setting or replacement if necessary. Pockets for Temperature Gauges The body of the anti-condensation valve in sizes DN25 (1 ) and DN32 (1¼ ) have pockets for temperature gauges on the front and rear sides. The pockets allow the installation of suitable temperatures gauges for measuring the three water temperatures and re-setting the thermostat if required. Code DN B C D E F kg 28005 20 R¾ 67.5 135 105.5 29 76.5 0.75 28026 20 R1 67.5 135 105.5 29 76.5 0.83 28006 25 R1 88.5 177 153.5 42 111.5 1.65 28007 32 R1¼ 97 194 157 40 117 2.05 Code 6 th Digit D E F Setting 45 C 55 C 60 C 70 C 4 5 6 7 Technical Specification Component aterial Specification Body: DN20 Brass BS EN 12165 CW617N DN25 & DN32 Brass BS EN 1982 CB753S Cap: Brass BS EN 12164 CW614N Obturator: PSU Polymer Spring: Stainless steel Swing check valve: PPS Polymer Sealing elements: EPD Union sealing washers: Non-asbestos fibre Wax thermostatic sensor Performance edium: water glycol solution ax. glycol percentage: 50% ax. working pressure: 10 bar ax. operating temperature: 5 C to 100 C Connections Pipe connections: nti-condensation valve Setting temperature: Setting accuracy: Bypass complete closing temperature: male taper with union BS EN 10226 45 C, 55 C, 60 C & 70 C ±2 C + 10 C

Components The Wooden biomass and condensation build-up Flow bypass Wooden solid fuel contains a variable moisture percentage depending on the type (logs, pellets, woodchips etc.) and seasoning. Water vapour is released during the solid fuel drying phase inside the combustion chamber. 5 7 The presence of cold zones in the boiler or flue gas chimney can lower the temperature of the flue gas down to the dew point, causing condensation to occur. Return to boiler 3 1 6 2 System return Water vapour condenses onto the boiler surfaces, together with soot and part of the unburnt hydrocarbons contained in the flue gas, producing deposits and tar. These substances stick to the walls of the boiler, covering most of the inner surfaces. In addition to being dangerous due to its flammability, tar is damaging to the integrity of the boiler and limits the efficiency of the flue gas-system water exchanger. 1 nti- condensation thermostatic sensor 2 Obturator 3 Spring 4 Cap 5 Valve body 6 Temperature gauge pocket Kv Values and Flowrates 4 8 By keeping the boiler walls at the highest possible temperature, the anti-condensation recirculation and unit limits the formation of these substances, thereby increasing the combustion efficiency, controlling the emissions into the environment and prolonging the life of the boiler. Flue gas and emission control SF 100 80 DN20 DN25 DN32 50 pressure loss - kpa 30 20 10 8 5 3 10 20 30 50 80 100 200 flowrate - l/m ccumulation of ash and residues Primary and secondary air: Combustion efficiency SR NTI-CONDENSTION VLVE Zone ofcondensation forming: Deposits and tar Corrosion Reduction inheat exchanger efficiency Flammability Size DN20 DN20 DN25 DN32 Connection ¾ 1 1 1¼ Kv m 3 /h 3.2 3.2 9 12

Operating Principle The thermostat (1), which is completely immersed in the medium, controls the obturator (2) that regulates the flow through the bypass port (7) and back towards boiler. s the boiler starts up from cold the anti-condensation valve re-circulates the water so that it brings the boiler up to temperature as quickly as possible. Operating Principle Continued > +10 C SYSTE LODING by-pass closed > > +10 C, = SYSTE STRTUPTRNSIENT system returnclosed, = = ixed water temperature returning to boiler = Return water temperature from storage cylinder = Flow temperature = nti-condensation set temperature When the flow temperature exceeds the set temperature of the anti-condensation valve, the units cold port (8) starts to open to produce mixed water, in this phase the system loading begins. > STRT OF SYSTE LODING >, <, = Schematic Symbols When the return temperature to the boiler is greater than the set temperature of the anti-condensation valve by 10 C, the bypass port (7) closes and water returns to the boiler at the same temperature as the water returning from the storage cylinder. > +10 C SYSTE LODING > > +10 C, = Deaerator Dirt separator Pump Shut-off valve Expansion vessel Check valve otorised mixing valve Pressure reducing valve Filling unit Backflow preventer Safety reliefvalve Dirt separator for vertical pipes Deaerator for vertical pipes Y-strainer

Typical pplications Biomass Boiler with Calorifier for Indirect Heating Biomass Boiler with Direct Heating and Calorifier E & O.E ltecnic Ltd ustang Drive, Stafford, Staffordshire ST16 1GW T: +44 (0)1785 218200 E: sales@altecnic.co.uk Registered in England No: 2095101 altecnic.co.uk L 178 19-03-14