Radiators: indirect energy metering and components

Similar documents
PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS

Chapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING

Metering systems 0548EN April 2014

R557R EN January 2012

DIRECT AND INDIRECT THERMAL ENERGY METERING

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

Convertible radiator valve for one-pipe systems, centre distance 35 mm

2-way. One source of elements. Many opportunities for greater profits. communication

Thermostatic head with wax sensor

1125 PIR Motion Detector

Systems for central heating

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

Radiator Valve Program

evohome controls evohome consists of a number of quality components manufactured by the UK s leading manufacturer of home heating controls.

Home. evohome WiFi MULTI-ZONE SYSTEM

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Boiler room components 0463EN October 2013

Metering systems 0371EN July 2016 User satellites, GE556 series Versions GE556Y301, GE556Y302

Danfoss ECO. The easy way to Smart Heating

caleffi hydronic valves page 1 of 12

IVR MULTIKLIMA. IVR Multiklima Units for Metering of water and energy consumption and Distribution in central heating and plumbing systems

T. +44 (0) E.

ModuSat TP. Energy. Heat Interface Units

PTG series valves 0490EN June 2018 Valves with thermostatic option for radiators, with presetting

HEATING PRODUCTS P R I C E L I S T

living connect, Electronic Radiator Thermostat

. SMARTHOME B.E.G. The comprehensive solution for home automation. Energy efficiency Fire safety. Comfort

Heating Technology sinc e

evohome multi-zone system evohome

THERMAL RADIATORS STORAGE HEATERS PANEL HEATERS TOWEL RAILS CENTRAL HEATING BOILERS.

Installation & Operating Instructions

Section - A. Radiator Valves

IC60 Sintony 60 Intrusion Control Panel

1126 Series Ceiling Mount PIR Motion Detector

ENERGY EFFICIENT ELECTRIC RADIATORS YOU CAN RELY ON. The professional heating solution

ModuSat TP. Energy. Heat Interface Units

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

your silent and loyal servant

SMARTWALK DEMENTIA WANDERING SYSTEM

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

All Valve Industries. General Product Overview. Distributed by All Valve Industries. Ph: Fax:

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC)

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

Thermostatic heads. For all thermostatic valve bodies and radiators with integrated valves

Sirius SAT. Working towards a cleaner future. Heat Boxes with Wireless Data Transmission. heating specialists

Sentry Freedom Wireless Emergency Call

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

Electronic controllers. Comfort embellishes everyday life

BRINGING GLASS to life. Beauty from within... INNOVATION COMES BUILT-IN


Hyperchill. water chillers

GIACOMINI HEAT INTERFACE UNITS

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

SOLUTIONS GUIDE. For total efficiency

LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET FEATURES

Art-Line. Absolutely Brilliant Temperature control was never so good

Operation and Maintenance Manual

GSM RFID VOICE Alarm System

AMAX Intrusion Alarm Systems System overview

The QUNDIS product world

Valves, controls + systems Flow, pressure and temperature balancing

BUG DETECTOR WITH ANALOG AND DIGITAL OPTIONS SKU: CDRFAD

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

RA2000 Commercial TRVs

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

Long Range Radio Alarm Transmitter

Architectural and Engineering Specification for a. Flash / Flare

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

Innovation + Quality. Product range. Awards:

Home. evohome multi-zone, Lyric T6 programmable thermostat and Single Zone thermostat. Smart Heating Controls THE COMPLETE CONNECTED CHOICE

HEATING AND COOLING UNDERFLOOR SYSTEM

ADPRO PRO Passive Infrared Detector. Webinar November Ben Klösen, PLM

DATAssure. Laboratory wireless alarm & monitoring system

Mercury Mixing Kit (Code: ME1053)

white blue cobalt bordeaux light oak (rovere)

PROGRAMMABLE 7-DAY RF THERMOSTAT

COMFORT IP: Room Control Unit Radio with Display

Floor heating controls, radio connection 1

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

Thermostatic Actuators

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

PRODUCT DIAGRAM PACKAGE CONTENTS

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Detecting Leaks and Reverse Flow with 60 Series Endpoints

B.E.G. PRESS KIT 2013

PRODUCT DIAGRAM PACKAGE CONTENTS

DOW1171 / DCW1151 Radio fire detection system

Wireless Door Detector

Wireless Central Monitoring Unit

E-pro. Time adaptor with E-Pro Stick for thermostatic valves

>WIRELESS> ALARM SYSTEM CR200

Transcription:

ENERGY MANAGEMENT E001EN PRODUCTS Radiators: indirect energy metering and components Heat cost allocators for energy consumption metering, thermostatic heads, valves and lockshield valves, air vent valves, caps and accessories for radiators Electronic heat cost allocator with data transmission via radio frequency signals A wide range of lowinertia thermostatic actuators with liquid sensor Valves with thermostatic option with and without pre-adjustment, for single-pipe and twin-pipe systems. Also available chrome-plated Lockshield valves with iron pipe or adaptor connection. Also available chrome-plated ENERGY MANAGEMENT

ENERGY MANAGEMENT Our passion for energy has been with us right from the start. It even comes out in our corporate colour, energising red, and our motto - WATER E-(energy)-MOTION. For Giacomini, energy management translates into components for energy consumption optimisation and metering, and for the distribution of hot and cold fluids.

ENERGY MANAGEMENT Indirect energy metering Even in buildings where radiators systems operate via old-fashioned risers piping, heating costs can be allocated on the basis of real consumption, to respect European directives and national regulations about energy requalification.. By combining thermoregulation (our thermostatic valves) and metering (our electronic heat cost allocators), even old-fashioned systems can be requalified and brought in line with current requirements in terms of comfort and energy efficiency. The GE700 electronic heat cost allocator produces a reliable estimate of the energy transferred from the radiator to the environment. The detected data are transmitted via radio frequency - safely and harmlessly to health - to the measurement devices located outside the apartment. Thanks to the wide range of support brackets and accessories, these devices can be assembled on all the most common radiators on the market (π5). Complete range of electronic Wireless M-Bus devices for managing the energy consumption data obtained by heat cost allocators. Radio frequency transmission allows consumption data to be obtained outside the apartment in a safe, reliable, continuous manner that respects the residents privacy (π6). Indirect metering works together with individual thermoregulation performed by the thermostatic valves installed on radiators. The thermostatic heads (adjustable to suit the user) guarantee the precise temperature control in each room in a simple, reliable way, ensuring constant optimum comfort and interesting energy savings.

4 5 Radio electronic heat cost allocator GE700 2 1 Manufactured in compliance with Standard UNI EN 834, with 2-sensor technology 1 for detecting radiator temperature and room temperature. Anti-tampering seal and disassembly alarm. 2 6-figure display for direct reading, optic interface for programming/ reading, long-life lithium battery (standard 10 years). 1 Brackets Complete range of support elements for every type of radiator.

ENERGY MANAGEMENT Antennas and concentrator Heat cost allocators and data management devices can transmit the data in Wireless M-Bus mode at 868 MHz (European band ISM - Industrial, Scientific, Medical). The consumption data can be read in two ways: 1 centralised (remote) or 2 Walk-by, via a mobile terminal supplied to the appropriate personnel. 1 Concentrator and transmitter 2 USB wireless receiver

6 7 Advantages of indirect metering G A Compliance with national regulations in terms of the energy requalification of existing buildings 1:1 Energy bill reflects real consumption Residents can manage in a very accurate way different temperature for different rooms, according to their specific needs Accurate billing motivates users to avoid waste by adjusting room temperatures to actual needs, prompting economic savings Comfort and energy savings thanks to individual thermoregulation User-friendly data reading: consumption data can be gathered via radio frequency, right outside the apartment

ENERGY MANAGEMENT Components for radiators The most traditional device for heating a room - the radiator - has always been able to rely on Giacomini components. We are universally recognised as specialists in the manufacture of valves, lockshield valves, thermostatic heads, and all the other accessories involved in the operation of heating elements. Technical skill, production reliability, wide range: these are the characteristics that allow us to easily equip every type of radiator, whether in new installations or in energy requalification projects. A wide range of low-inertia thermostatic actuators with liquid sensor, for automatically adjusting and controlling the radiator temperature. By automatically adjusting the hot fluid inflow to the radiator on the set value basis, optimum comfort and energy savings are guaranteed. Compatible with Giacomini valve bodies and other manufacturers too. The new frontier for Giacomini radiator valve actuators: the electronic chrono-thermostatic head. A technologically advanced device with a long operating life, silent and compact. The function keys, wheel selector and LCD display ensure easy weekly programming, with various daily activation bands and three different temperature set-points: comfort, economy/night and antifreeze.

8 9 1 2 2 1 Valves with thermostatic option (with and without pre-adjustment) 2 manual valves, lockshield valves: all these components are available in various configurations and measurements for installation on the main radiators available on the market. Also available 3 chrome-plated for toweldryers (π15). 3 4 5 4 Vast assortment of manual valves and valves with thermostatic option for 4 single-pipe and 5 twin-pipe applications (π14). In particular, the micrometric valve with thermostatic option, with an adjustable command handwheel, is the universal solution for requalification projects. 4 5 6 7 8 9 Manual and 6 automatic 7 air vents, radiator caps 8, accessories such as hole-cover rosette trims 9 and telescopic tail pieces 10 complete our range (π16). 9 10

ENERGY MANAGEMENT Energy efficiency of the thermostatic heads Thanks to the construction methods that ensure a low degree of hysteresis, quick response times, reduced influence on the temperature of the heating fluid and on the differential pressure, the Giacomini thermostatic heads ensure a high energy efficiency performance. Operation elements designed for every need 1 2 Valves fitted with an elegant handwheel in glossy white ABS 1 for manual valve command, or with 2 worksite protection with the possibility of operation during the installation and testing phase. 3 Internal bonnet anti-blocking-system Inside the operating mechanism of the valve with thermostatic option, there is 3 a single-piece stainless steel operating stem that notably reduces the adhesion of calcareous deposits and therefore the risk of the bonnet itself becoming stuck. 4 If the bonnet gets damaged, it can be replaced without draining the system, via the R400 key. 4

10 11 Self-sealing tail-piece Valves are linked to the heating body via a tail piece with a selfsealing gasket in an elastomeric material. Without the need for hemp, paste or other sealing materials, joints can be made quickly and will prove reliable over time. Valves with pre-adjustment Thanks to the special operating bonnet, the PTG series valves can be pre-adjusted to generate a deliberate pressure loss and hence ensure the effective balancing of the circuit. Universal valve R304T for single-pipe and twin-pipe systems Can be installed in both single-pipe and twin-pipe systems, thereby facilitating the work of the installer. On top of that, the adjustable handwheel ensures the maximum flexibility for the ideal adjustment of the thermostatic head installed.

ENERGY MANAGEMENT Advantages of thermostatic valves Comfort and energy savings thanks to individual temperature regulation Tax incentives for energy requalification projects Attractive design and prime materials

12 13 Catalogue Valves with thermostatic option, and lockshield valves R421TG R14TG R422TG R15TG R401TG R402TG R431TG R29TG R432TG R31TG R411TG R412TG R435TG R403TG

ENERGY MANAGEMENT Valves with thermostatic option, with pre-adjustment R401PTG R402PTG R411PTG R412PTG R415PTG Manual valves and valves with thermostatic option for single and twin-pipe systems R304T R440N R356B1 R357B1 R358B1 R437N R356M1 R357M1 R358M1 R324N

14 15 Valves for toweldryers (with brilliant chrome-plating) T439L T431C T29C T432C T31C T25C T27C T357M T358M Thermostatic heads R470 T470 R468C R462 R463 R462L

ENERGY MANAGEMENT Electrothermal actuators R473 R473M R478 R478M Energy requalification kit for radiators R470F without heat cost allocator R470A without heat cost allocator Other radiator components (air vents, caps) R200 R66A R90 R92 R173

16 17 Heat cost allocators for indirect metering and accessories GE700 GE700-1 GE700-2 Concentrator and wireless data transmitter GE552W Wireless data receiver antenna Wireless signal repeater Software for programming the heat cost allocators and for Wireless data centralisation

ENERGY MANAGEMENT E001EN - June 2014 Radiators: indirect energy metering and components Valves and lockshield valves Thermostatic heads Air vent valves Accessories for radiators Heat cost allocator Data concentrator Data transmitter Data receiver Giacomini S.p.A. Via per Alzo, 39 28017 San Maurizio d Opaglio (NO), Italy Phone (+39) 0322 923111 GIACOMINI.COM