CoolSpot Engineering Guide

Similar documents
VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

CoolSpot. Unique Solutions for All-Indoor HVAC Projects

VariCool VAV Engineering Guide

C13-Series Engineering Guide

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

VertiCool Aurora Engineering Guide

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

C-Series. Unique Solutions for All-Indoor HVAC Projects

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery

C13-Series. Unique Solutions for All-Indoor HVAC Projects

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

VariCool EZ-Fit 12 to 70 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water

SKYPAK II, 3 Ton Series, gives you a

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

technical guide Water-Cooled Self-Contained Units

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

SKYPAK II, 3 Ton Series, gives you a

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Water-Cooled Self-Contained Units

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

VariCool EZ-Fit. Unique Solutions for All-Indoor HVAC Projects

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Advance Release September 2009

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

GUIDE SPECIFICATIONS AQUARIUS ii

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Commercial High-Efficiency Condensing Units

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

MACH N-407 Heat Pump Air-Cooled Chiller

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS

MAC-120HE-03 Air-Cooled Chiller

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Modular Indoor Systems For Effective Environmental Control

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL

Roof Top Packaged Unit (RTU-1) Specification

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

DXair Pool Dehumidifiers

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

SKY-COM HI-CAP SERIES. Precise Environmental Control SKY-COM 15 & 20 TON Series. Suited for Telecommunications, Laboratories and Computer Rooms

MAC N-407 Air-Cooled Chiller

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

50TM COMBINATION HEATING/COOLING UNITS

Commercial High-Efficiency Condensing Units

Air-Cooled Condensing Units with Compact Screw Compressors

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

SKYPAK II Heating & Cooling Self Contained Packages

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data)

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Split System Heat Pumps

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

50TM TFF COMBINATION HEATING/COOLING UNITS

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

Transcription:

Engineering Guide Effective December 2017 Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package

Contents Contents....................................................... 2 Product Features and Options..................................... 3 Physical Data................................................... 4 Common Physical Data.......................................... 4 Air-Cooled Physical Data......................................... 4 Physical Data................................................... 5 Water-Cooled Physical Data...................................... 5 Chilled Water.................................................. 5 Air-Cooled Units................................................. 6 Unit Capacity Ratings............................................ 6 Air-Cooled Electrical Data......................................... 7 Electrical Data................................................. 7 Electrical Data with Magna Cool Package............................ 7 Water-Cooled Units.............................................. 8 Unit Capacity Ratings............................................ 8 Electrical Data................................................. 8 Water-Cooled Units (cont.)........................................ 9 Electrical Data with MagnaCool Package............................ 9 Chilled Water Units............................................... 9 Unit Capacity Ratings............................................ 9 Chilled Water Electrical Data...................................... 10 Electrical Data................................................ 10 Dimensional Data...................................... 11 Draw-Thru, Air-Cooled Units..................................... 11 Draw-Thru, Water-Cooled, Chilled Water or when matched with Remote Condensing Unit............................................... 11 Air-Cooled Unit Configurations.................................... 12 Subject to change without notice. 2

Product Features and Options The is a self contained air conditioning system designed specifically for spot cooling applications. The is mounted above the ceiling with integral supply and return grill that fits a standard 2' x 4' ceiling grid. There are five cooling capacities ranging in size from one to three tons making it ideal for supplementary cooling of existing space or new construction. The standard air-cooled unit comes with a belt-driven condenser fan that has field adjustable external static pressure ranging from.1 to 1.0" to allow for various sizes and lengths of ductwork. A remote air-cooled condenser is also available for exterior installation. Other cooling options include water/glycol cooled and chilled water units. Air-Cooled, Water-Cooled or Chilled Water Configurations R-410A Refrigerant, Factory Charged 1 thru 3 Ton Ceiling Grid Mounted Package Unit Rubber Vibration Isolators Cabinets Constructed of Scratch Resistant Heavy Duty Galvanized Steel Adjustable Supply Grille Return Air Grille w/ Integrated Filter Rack Completely Serviceable at Ceiling Accessible from conditioned space behind filter: 1. Sight Glass/Moisture Indicator 2. High and Low Side Schrader Access Fittings Access Through Both Sides of Unit Fits through 29" doorways Variety of Thermal/Acoustical Insulation In Return/Supply Plenum, Evaporator Section and Condenser Blower Section Stainless Steel Drain Pan in Evaporator Section Drain Pan Overflow Switch Internal Condensate Pump Ball Bearing Motor(s) Belt drive blowers Cast iron pulley and sheaves Inherently Protected Motors and Compressors Loss of Air Safety Switch (when electric heat is used) Reciprocating Compressor Crankcase Heater All internal components are located for easy access through removable side panels, and routine maintenance is accomplished by removing adjacent ceiling tiles. Refrigerant service ports are mounted on a bulkhead easily accessible through the return air grill. Operating pressures can be determined without removing ceiling tiles. The can provide temperature and humidity control for your equipment cooling requirements when ordered with the MagnaCool package which includes the optional microprocessor controller, electronic steam canister humidifier and finned tubular electric reheat. The full featured Marvel J microprocessor allows control of multiple s from one remote location. Rubber-In-Shear Vibration Isolators for all Compressors Refrigerant Line Vibration Eliminator Individual Contactor for each Motor, Compressor and Electric Heat Element Adjustable Expansion Valve with External Equalizer High and Low Pressure Safety Switches Filter Drier 1", MERV 8 Pleated Filter Co-axial Counterflow Heat Exchanger on Water-Cooled Units Condenser Drain Pan on Water-Cooled Units Functionally Run Tested at the Factory One Year Limited Warranty on Parts and Five Year Limited Warranty on Compressor (Labor Not Included) Partial List of Options (items in BOLD are factory installed): 2-way, 150 psig Water Regulating Valve 3-way and 350 psig Water Regulating Valves Condenser Drain Pan on Water-Cooled Units Electric Heat or Reheat (finned tubular) Freezestat Heresite Coated Coils Hot Gas Bypass Low Ambient Controls Microprocessor Controls Non-Fused Disconnects Steam Canister Humidifier Subject to change without notice. 3

Physical Data Common Physical Data Voltage Voltage Filter Evap. Blower Evap. Coil MODELS CS, CSW, CSR 208/230-1-60 Yes Yes Yes Yes Yes 208/230-3-60 No Yes Yes Yes Yes 460-3-60 No Yes Yes Yes Yes MODELS CSRC, CSWRC, CSC 208/230-1-60 Yes Yes Yes Yes Yes 208/230-3-60 Yes Yes Yes Yes Yes 460-3-60 Yes Yes Yes Yes Yes Size (in.) 20 X 20 X 1 Qty 1 Type Pleated Throwaway CFM 400 600 800 1000 1200 Size 10-7 (Qty. 1) Motor HP 1/4 1/2 3/4 Rows Deep 3 3 Face Area (ft 2 ) 2.1 2.6 FPI 10 12 Air-Cooled Physical Data MODEL CS CFM 1100 1200 1250 1400 1700 Cond. Blower Max. ESP 0.5 0.25 0.5 Size 9-9 (Qty. 1) Motor HP 1/2 3/4 1 1-1/2 Rows Deep 4 5 Condenser Coil Face Area (ft 2 ) 2.1 FPI 12 14 Compressor Qty. 1 Charge R410A (Lbs-Ozs) 3-12 4-0 4-4 Weight (Net Operating, Lbs.) 450 500 590 MODEL CSR Compressor Qty. 1 Charge R410A (Lbs-Ozs) 2-12 2-13 3-0 Weight (Net Operating, Lbs.) 300 310 370 410 MODEL CSRC Charge R410A (Lbs-Ozs) 2-12 2-13 3-0 Weight (Net Operating, Lbs.) 260 300 325 Subject to change without notice. 4

Physical Data Water-Cooled Physical Data MODEL CSW Condenser Coil Pressure Drop 5.6 6.5 12.4 10.4 8.9 GPM 3 4.5 6 7.5 9 Compressor Qty. 1 Charge R410A (Lbs-Ozs) 2-0 2-8 Weight (Net Operating, Lbs.) 350 400 480 MODEL CSWRC Charge R410A (Lbs-Ozs) 2-0 2-8 Weight (Net Operating, Lbs.) 260 300 325 Chilled Water MODEL CSC Pressure Drop 5.3 4.8 8.2 7.0 9.9 GPM 3 4.5 6 7.5 9 Chilled Water Coil Rows Deep 3 4 Face Area (Ft 2 ) 1.9 2.4 Valve Size 5/8 (c) 7/8 (c) Weight (Net Operating, Lbs.) 260 330 (c) Valve size listed is for on/off application. Modulating applications will may require a different valve size Subject to change without notice. 5

Air-Cooled Units Unit Capacity Ratings Model No. CS12G*ASTA CS18G*ASTA CS24G*ASTA CS30G*ASTA CS36G*ASTA Entering Air Air Over Condenser 75 95 115 D.B. W.B. Total Sensible Total Sensible Total Sensible 80 67 17725 11378 15268 10281 12565 9105 75 62 16092 11348 13777 10204 11261 9029 72 60 15443 10953 13191 9805 10751 8629 80 67 22605 14831 19342 13361 16011 12050 75 62 20564 14738 17649 13376 14587 12072 72 60 19764 14206 17044 13012 14028 11570 80 67 27293 18124 23509 16377 19644 14836 75 62 24837 17904 21419 16284 17912 14876 72 60 23884 17279 20634 15674 17213 14203 80 67 36915 26278 32179 24148 26443 21750 75 62 33895 26292 29594 24296 24231 21725 72 60 32740 25404 28552 23306 23386 20787 80 67 42106 30448 36564 27945 30246 25139 75 62 38781 30618 33476 28037 27372 24988 72 60 37452 29372 32242 26831 26155 23778 Subject to change without notice. 6

Air-Cooled Electrical Data Electrical Data Model No. Voltage (a) Nom. Comp. Evap. Motor Cond. Motor Tons LRA RLA HP FLA HP FLA MCA MOP CS12G1ASTA 208/230-1-60 1 43 5.9 1/4 2.7 1/2 4.5 14.6 20 CS18G1ASTA 208/230-1-60 43 7.4 1/4 2.7 1/2 4.5 16.5 20 CS18G3ASTA 208/230-3-60 1.5 63 5.9 1/4 0.9 1/2 2 10.3 15 CS18G4ASTA 460-3-60 30 2.9 1/4 0.45 1/2 1 5.1 6 CS24G1ASTA 208/230-1-60 54 9.9 1/4 2.7 3/4 5.8 20.9 30 CS24G3ASTA 208/230-3-60 2 63 6.9 1/4 0.9 3/4 3 12.5 15 CS24G4ASTA 460-3-60 30 3.6 1/4 0.45 3/4 1.5 6.5 10 CS30G1ASTA 208/230-1-60 88 13 1/2 4.5 1 6.7 27.5 40 CS30G3ASTA 208/230-3-60 2.5 68 8.6 1/2 2 1 3.7 16.5 25 CS30G4ASTA 460-3-60 34 4.2 1/2 1 1 1.85 8.1 10 CS36G1ASTA 208/230-1-60 84 14.5 3/4 5.8 1.5 8.6 32.5 45 CS36G3ASTA 208/230-3-60 3 88 10.2 3/4 3 1.5 5 20.8 30 CS36G4ASTA 460-3-60 44 5.1 3/4 1.5 1.5 2.4 10.3 15 Electrical Data with Magna Cool Package Model No. Voltage (a) Nom. Comp. Evap. Motor Cond. Motor Heater Humid. Tons LRA RLA HP FLA HP FLA (b) Amps Amps MCA MOP CS12G1ASTA02 208/230-1-60 1 43 5.9 1/4 2.7 1/2 4.5 9.1 5.4 31.3 35 CS18G1ASTA02 208/230-1-60 43 7.4 1/4 2.7 1/2 4.5 9.1 5.4 33.2 35 CS18G3ASTA02 208/230-3-60 1.5 63 5.9 1/4 0.9 1/2 2 9.1 5.4 27.1 30 CS18G4ASTA02 460-3-60 30 2.9 1/4 0.45 1/2 1 4.3 5.4 15.4 20 CS24G1ASTA05 208/230-1-60 54 9.9 1/4 2.7 3/4 5.8 22.7 5.4 54.7 60 CS24G3ASTA05 208/230-3-60 2 63 6.9 1/4 0.9 3/4 3 22.7 5.4 46.3 50 CS24G4ASTA05 460-3-60 30 3.6 1/4 0.45 3/4 1.5 10.9 5.4 25.9 30 CS30G1ASTA05 208/230-1-60 88 13 1/2 4.5 1 6.7 22.7 5.4 61.3 70 CS30G3ASTA05 208/230-3-60 2.5 68 8.6 1/2 2 1 3.7 22.7 5.4 50.3 60 CS30G4ASTA05 460-3-60 34 4.2 1/2 1 1 1.85 10.9 5.4 27.4 30 CS36G1ASTA05 208/230-1-60 84 14.5 3/4 5.8 1.5 8.6 22.7 5.4 66.3 70 CS36G3ASTA05 208/230-3-60 3 88 10.2 3/4 3 1.5 5 22.7 5.4 54.6 60 CS36G4ASTA05 460-3-60 44 5.1 3/4 1.5 1.5 2.4 10.9 5.4 29.3 30 (a) 277 volt/ single phase available with a buck boost transformer Subject to change without notice. 7

Water-Cooled Units Unit Capacity Ratings Model No. GPM PD (psi) CFM CSW12G*ASTA 3 5.6 400 CSW18G*ASTA 4.5 6.5 600 CSW24G*ASTA 6 12.9 800 CSW30G*ASTA 7.5 10.4 1000 CSW36G*ASTA 9 8.9 1200 Entering Air EWT = 85F D.B. W.B. Total Sensible 80 67 16983 11031 75 62 15213 10933 72 60 14549 10510 80 67 22915 14996 75 62 20661 14906 72 60 19780 14354 80 67 28113 18574 75 62 25490 18431 72 60 25345 15372 80 67 38950 27105 75 62 35331 26978 72 60 33917 25926 80 67 44952 31595 75 62 40953 31604 72 60 39431 30364 Electrical Data Model No. Voltage (a) Nom. Tons Evap. Motor HP FLA MCA MOP CSW12G1ASTA 208/230-1-60 1 1/4 2.7 10.1 15 CSW18G1ASTA 208/230-1-60 1/4 2.7 12 15 CSW18G3ASTA 208/230-3-60 1.5 1/4 0.9 8.3 10 CSW18G4ASTA 460-3-60 1/4 0.45 4.1 5 CSW24G1ASTA 208/230-1-60 1/4 2.7 15.1 25 CSW24G3ASTA 208/230-3-60 2 1/4 0.9 9.5 15 CSW24G4ASTA 460-3-60 1/4 0.45 5 6 CSW30G1ASTA 208/230-1-60 1/2 4.5 20.8 30 CSW30G3ASTA 208/230-3-60 2.5 1/2 2 12.8 20 CSW30G4ASTA 460-3-60 1/2 1 6.3 10 CSW36G1ASTA 208/230-1-60 3/4 5.8 23.9 35 CSW36G3ASTA 208/230-3-60 3 3/4 3 15.8 25 CSW36G4ASTA 460-3-60 3/4 1.5 7.9 10 (a) 277 volt/ single phase available with a buck boost transformer Subject to change without notice. 8

Water-Cooled Units (cont.) Electrical Data with MagnaCool Package Model No. Voltage (d) Nom. Comp. Evap. Motor Heater (b) Humid. Tons LRA RLA HP FLA Amps Amps MCA MOP CSW12G1ASTA02 208-1-60 1 43 5.9 1/4 2.7 9.1 5.4 26.9 30 CSW18G1ASTA02 208-1-60 43 7.4 1/4 2.7 9.1 5.4 28.7 30 CSW18G3ASTA02 208-3-60 1.5 63 5.9 1/4 0.9 9.1 5.4 25.1 30 CSW18G4ASTA02 460-3-60 30 2.9 1/4 0.45 4.3 5.4 14.4 20 CSW24G1ASTA05 208-1-60 54 9.9 1/4 2.7 22.7 5.4 48.9 50 CSW24G3ASTA05 208-3-60 2 63 6.9 1/4 0.9 22.7 5.4 43.3 45 CSW24G4ASTA05 460-3-60 30 3.6 1/4 0.45 10.9 5.4 24.4 25 CSW30G1ASTA05 208-1-60 88 13 1/2 4.5 22.7 5.4 54.5 60 CSW30G3ASTA05 208-3-60 2.5 68 8.6 1/2 2 22.7 5.4 46.5 50 CSW30G4ASTA05 460-3-60 34 4.2 1/2 1 10.9 5.4 25.6 30 CSW36G1ASTA05 208-1-60 84 14.5 3/4 5.8 22.7 5.4 57.7 60 CSW36G3ASTA05 208-3-60 3 88 10.2 3/4 3 22.7 5.4 49.5 60 CSW36G4ASTA05 460-3-60 44 5.1 3/4 1.5 10.9 5.4 27.0 30 (d) 277 volt/single phase available with a buck boost transformer Unit Capacity Ratings Chilled Water Units Model No. CSC12G*-T- CSC18G*-T- CSC24G*-T- CSC30G*-T- CSC36G*-T- Entering Air (of) Ent. Water Temp. = 45oF Evaporator Blower Performance GPM D.B W.B Total Sensible CFM Blower Size HP 80 67 13468 9910 3 75 62 10281 9000 3 400 10-7 1/4 72 60 9031 8202 3 80 67 18792 14028 4.5 75 62 14352 12744 4.5 600 10-7 1/4 72 60 12616 11611 4.5 80 67 23451 17767 6 75 62 17933 16149 6 800 10-7 1/2 72 60 15780 14709 6 80 67 31291 23421 7.5 75 62 23926 21289 7.5 1000 10-7 1/2 72 60 21040 19398 7.5 80 67 35926 27126 9 75 62 27479 24659 9 1200 10-7 3/4 72 60 24177 22464 9 Subject to change without notice. 9

Chilled Water Electrical Data Electrical Data Model No. (d) Voltage Nom. Tons Evap. Motor HP FLA MCA MOP CSC12G102 208-1-60 1 1/4 2.7 3.4 6 CSC18G102 208-1-60 1/4 2.7 3.4 6 CSC18G302 208-3-60 1.5 1/4 0.9 1.1 3 CSC18G402 460-3-60 1/4 0.45 0.6 1 CSC24G105 208-1-60 1/4 2.7 3.4 10 CSC24G305 208-3-60 2 1/4 0.9 1.1 3 CSC24G405 460-3-60 1/4 0.45 0.6 1 CSC30G105 208-1-60 1/2 4.5 5.6 10 CSC30G305 208-3-60 2.5 1/2 2 2.5 3 CSC30G405 460-3-60 1/2 1 1.3 3 CSC36G105 208-1-60 3/4 5.8 7.3 10 CSC36G305 208-3-60 3 3/4 3 3.8 6 CSC36G405 460-3-60 3/4 1.5 1.9 3 Model No. (d) Voltage Nom. Tons Evap. Motor Heater Humid HP FLA Amps (a) Amps MCA MOP CSC12G1-T-2 208-1-60 1 1/4 2.7 9.1 5.4 20.8 25 CSC18G1-T-2 208-1-60 1/4 2.7 9.1 5.4 20.8 25 CSC18G3-T-2 208-3-60 1.5 1/4 0.9 9.1 5.4 19 25 CSC18G4-T-2 460-3-60 1/4 0.45 4.3 5.4 11.5 20 CSC24G1-T-5 208-1-60 1/4 2.7 22.7 5.4 37.9 40 CSC24G3-T-5 208-3-60 2 1/4 0.9 22.7 5.4 36.1 40 CSC24G4-T-5 460-3-60 1/4 0.45 10.9 5.4 20.8 25 CSC30G1-T-5 208-1-60 1/2 4.5 22.7 5.4 39.7 45 CSC30G3-T-5 208-3-60 2.5 1/2 2 22.7 5.4 37.2 40 CSC30G4-T-5 460-3-60 1/2 1 10.9 5.4 21.4 25 CSC36G1-T-5 208-1-60 3/4 5.8 22.7 5.4 41.1 45 CSC36G3-T-5 208-3-60 3 3/4 3 22.7 5.4 38.2 40 CSC36G4-T-5 460-3-60 3/4 1.5 10.9 5.4 21.8 25 277 volt/single phase available with buck boost tranformer (d) * - 2 or 5KW to be decided based off of customer request Subject to change without notice. 10

Dimensional Data Draw-Thru, Air-Cooled Units 1.000 52.500 28.000 22.500 30.250 28.000 20.500 1.000 DUCT CONNECTION SIZE: 10"W X 14"H (RIGHT HAND SHOWN, LEFT HAND OPTIONAL) CONDENSER BLOWER SECTION 54.750 28.000 5.000 14.938 1/4" FLARE CONDENSATE DRAIN CONNECTION 8.094 11.812 21.000 ACCESS PANEL ACCESS PANEL 9.75 CONDENSER AIR INLET DUCT CONNECTION CONDENSER BLOWER ACCESS PANEL 18.000 CONDENSER AIR DISCHARGE 10.250 24.0 5.438 4.813 3.000 GRILLE SKIRT RETURN AIR 2.000 SUPPLY AIR 22.8 ELECT. ENTRANCE 15.375 46.500 HUMIDIFIER/CONDENSATE DRAIN CONNECTION (OPTIONAL) Draw-Thru, Water-Cooled, Chilled Water or when matched with Remote Condensing Unit 1.000 52.500 28.000 30.250 1.000 18.125 54.750 14.125 5.000 1/4" FLARE 10.125 CONDENSATE 14.938 DRAIN CONNECTION 4.000 2.875 ACCESS PANEL ACCESS PANEL 9.75 ACCESS PANEL 6.375 QUICK CONNECT LOCATIONS REMOTE CONDENSING ONLY 21.000 24.0 4.813 7.0 3.000 GRILLE SKIRT RETURN AIR 2.000 SUPPLY AIR WATER IN & OUT CONNECTIONS WATER COOLED UNITS ONLY 22.8 ELECT. ENTRANCE 15.375 46.500 HUMIDIFIER/CONDENSATE DRAIN CONNECTION (OPTIONAL) Subject to change without notice. 11

Air-Cooled Unit Configurations CS Self Contained Air-Cooled (CS) Shown Water-Cooled (CSW) Available Chilled Water (CCW) Available CSR BC* Remote Condenser Section CSRC B* Remote Condensing Section CSRC B (Dual Circuit) * Multiple Evaporators with Single Remote Condensing Section CSRC * Remote condensers or condensing sections can also be water-cooled or propeller type. Subject to change without notice. 12

Unique Solutions for All-Indoor HVAC Projects VertiCool Classic Vertical, 3-30 Ton VertiCool Aurora Vertical, 3-35 Tons VariCool VAV, 9-70 Tons VariCool EZ-Fit VAV, 12-90 Tons Alpha Aire 100 500 CFM Portable Cooling and Heating Units 3-30 Tons C13-Series Horizontal 2-10 Tons C-Series Horizontal 1-15 Tons Special Configuration Engineered to Order OmegaAir Horizontal and Vertical 100% Outside Air 150 3000 CFM Authorized Distributor: LIMITED WARRANTY United CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty. FACTORY TESTED All units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning. Industry proven components are used throughout to enhance system reliability and peace of mind. Scan to learn more about all of our products! 491 East Princess Street, York, PA 17403 Phone: 717-843-4311 Fax: 717-854-4462 email: uca@unitedcoolair.com web: www.unitedcoolair.com Copyright by United CoolAir Corporation 2017. All rights reserved. Manufacturer reserves the right to make changes without notice.