HEATING & COOLING COIL PRODUCTS

Similar documents
Engineered efficiency - no matter where or what. KMe Coolers Fresh ideas from Searle. GEA Searle

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

TEC Coolers. GEA Heat Exchangers. GEA Searle

Fincoil FMP and FMPG. Air coolers and liquid circulated air coolers

Center Mount Unit Coolers

Air cooler BC50 Blast freezer

GEA Searle Cooler and Condensing Unit Ranges Top-level engineering solutions. engineering for a better world. GEA Heat Exchangers

Blow through unit coolers LEX. Standard coolers for cooling & freezing rooms

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Evaporators 60HZ version

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Küba SG commercial

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

MACH N-407 Heat Pump Air-Cooled Chiller

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Air cooler VNS Agricultural

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

POWERPLUS SPP Product Brochure

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

Industrial Unit Coolers

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Goedhart VNS. Air coolers for agricultural applications Cu/Al R404A - CO 2. engineering for a better world. GEA Heat Exchangers

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

LOW PROFILE UNIT COOLER

Technical Data Ducted Three Phase Split System Air Conditioner

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

Remote Air Cooled Condensers C2 Series

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Low Flow Unit Coolers

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

LOW PROFILE UNIT COOLER

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

Centeral Station Air Handling Unit

MAC N-407 Air-Cooled Chiller

SECTION AIR COILS

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

Service Step by Step Trouble-Shooting Check-List

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

High Profile Evaporator

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

MAC-120HE-03 Air-Cooled Chiller

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

EHH SERIES DRAW THROUGH FAN COILS CFM

LOW PROFILE EVAPORATORS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

COOLING / HEATING COILS

Super-Flo Low Profile Unit Cooler

When You Need a Replacement Coil, Precision Matters.

TOPAZ ADIABATIC COOLER

CHAPTER 6 CONDENSING UNITS

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).


Aegean Range. A new range of fan coils for heating and cooling commercial applications

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

VariCool VAV Engineering Guide

EMI ENGINEERING SUBMITTAL

Process glycol chillers

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

SMALL AIR COOLED CONDENSERS

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

R Series Cooling Manual

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Transcription:

HEATING & COOLING COIL PRODUCTS FV & FVH FLOOR MOUNTED COOLERS Capacities 28-150kW White powder coated casing Aerofoil fans 4, 6 or 8mm fin spacing Vertical or horizontal air discharge

HEATING & COOLING COIL PRODUCTS The FV & FVH range of floor mounted coolers are designed to suit a wide range of cold storage, blast freezing, blast chilling, and food processing applications. The units are rigidly constructed with drawthrough aerofoil fans for efficient air throw and reliable performance. The coils can be offered for DX refrigeration or secondary refrigerants. SPECIFICATION Coil Manufactured from 5/8 o.d. copper tube mechanically expanded into heavy gauge aluminium plate fins will fully collared holes to ensure an efficient and permanent bond. Fin spacings 4 mm, 6 mm or 8 mm. Copper tube suction headers and distributors are individually sized to suit the exact operating conditions. Brazed joints are made with silver bearing copper alloy. Coils are pressure tested to 26 bar g, vacuum dehydrated and sealed with a dry nitrogen charge. Casing Galvanised sheet steel white polyester powder coated. Fans Axial flow, non overloading aerofoil fans with aluminium variable pitch blades secured into diecast aluminium hubs, keyed and locked onto the motor shaft. The fans run in a formed bell mouth orifice for efficiency and low noise. Motors Totally enclosed class F insulated metric frame, 380/420/3/50 Hz IP55.

DEFROST OPTIONS Electric For efficient defrosting low power density 200/250V 1 ph stainless steel sheathed elements are provided in the coil and draintray. Heaters are wired to a terminal box for 3 phase + neutral supply. ED 1 Light duty defrost for marginal room temperatures. ED 2 Normal duty defrost for low temperature applications. FP Fan Peripheral Heaters - for horizontal air discharge applications with room temperature below zero. Reverse Cycle / Hot gas OPTIONAL FEATURES Ducted Axial Fans Plain Galvanised Casing NS4 Marine Grade Aluminium Casing. Stainless Steel Casing Insulated Drain Pans Coils circuited for chilled water / glycol Coils may be circuited for reverse cycle or hot gas defrost with electric elements or hot gas tubes in the drain pan. HGE Hot gas coil, electric drain tray HGD Hot gas coil and tray RCE Reverse cycle coil, electric tray RCD Reverse cycle coil and tray NOISE LEVELS The noise levels stated are at a distance of 3 m from the unit at an angle of 45 to the horizontal in free field conditions with no reflections. These are intended to be used as a guide for comparison purposes. In practice the noise generated will be reflected off the enclosure surfaces and may be absorbed by the product within the room. For applications where noise levels are critical lower speed fans can be offered and the advice of an acoustic specialist is recommended. AIR THROW Cooler air throw is dependant upon coldstore design, product loading and positioning of coolers. Generally one metre space above product with no obstructions allows the air to travel considerable distances, providing that the room is tall and adequate space is allowed to return air at low level and velocity. Low head rooms need careful cooler siting and some means of separating discharge and return air. Cooler fans suck air back as well as blow. SELECTION Capacity tables are rated at - 8 C saturated suction temperature R22, O C air on temperature. Capacities are net heat extracted by the coil not including fan heat. Selection Example A cooler is required to do 56 kw with R22 evaporating @ -30 C, room temperature - 23 C with 6 mm fin spacing and horizontal air discharge into a false ceiling for blast freezing. Heavy Duty Electric Defrost is required. 1. Select correction factor from table for 7 K TD and - 30 C evaporating. 2. Factor = 0.74 3. Correct required duty to catalogue rated capacity. 56 / 0.74 = 75.67 kw 4. Select Model from capacity table. Model FVH1606 ED2.

FV & FVH CAPACITIES Coil Data Coil Data Fan Data Model Capacity 4 mm 6 mm Capacity 8 mm Air Vol 120 Pa ESP Air Noise Surface Internal Surface Internal Surface Internal Throw Level KW Area Volume Area Volume KW Area Volume Nom Nom dba@ 8K TD m2 dm3 m2 dm3 8K TD m2 dm3 m3/s No Dia rpm kw FLC M 3m 60 28.7 182 51.9 167 69.2 21.8 128 5.38 69.2 2 630 1400 1.1 2.9 30 80 70 33.5 212 60.5 194 80.7 25.4 150 6.28 80.7 2 630 1400 1.5 3.9 32 81 80 38.2 243 69.2 222 92.2 29.1 171 7.18 92.2 2 710 1400 1.5 3.9 35 82 90 43.0 273 77.8 250 103.8 32.7 192 8.07 103.8 2 710 1400 1.5 3.9 37 83 100 47.8 304 86.5 278 115.3 36.3 214 8.97 115.3 2 710 1400 2.2 5.3 40 83 120 57.3 364 103.8 333 138.4 43.6 257 10.77 138.4 3 710 1400 1.5 3.9 42 84 140 67.3 427 121.7 391 162.3 51.1 301 12.63 162.3 3 710 1400 2.2 5.3 45 85 160 76.5 486 138.3 444 184.4 58.1 342 14.35 184.4 3 710 1400 2.2 5.3 50 85 180 85.6 544 154.9 497 206.6 65.1 383 16.07 206.6 3 800 1400 3 6.9 55 86 200 97.9 622 177.1 569 236.1 74.4 438 18.37 236.1 3 800 1400 4 9.2 55 88 240 116.2 738 210.3 675 280.4 88.3 520 21.81 280.4 3 800 1400 4 9.2 60 88 280 133.9 851 242.3 778 323.1 101.8 599 25.14 323.1 4 800 1400 4 9.2 60 90 320 151.5 963 274.2 881 365.6 115.2 678 28.45 365.6 4 800 1400 4 9.2 60 90 Electric Defrost Coil & Drain Pan kw Fan 4mm 4mm 6&8mm 6&8mm Periphery Model ED1 ED2 ED1 ED2 kw 60 12.3 15.7 13.4 17.4 1.1 70 12.9 16.2 15.1 19.0 1.1 80 14.3 18.0 18.0 21.0 1.3 90 16.5 21.0 18.8 24.0 1.3 100 17.3 21.8 20.3 25.5 1.3 120 20.3 25.5 22.5 30.0 2.0 140 19.6 24.5 22.0 27.7 2.0 160 22.0 27.7 24.5 32.6 2.0 180 24.5 31.0 26.9 35.9 1.7 200 26.9 34.2 29.3 39.1 1.7 240 29.3 37.5 32.6 42.4 1.7 280 33.48 42.78 37.2 48.36 2.2 320 37.2 48.36 40.92 53.94 2.2 Total Fan Heat Intput Model kw 60 2.8 70 3.8 80 3.8 90 3.8 100 5.2 120 5.7 140 7.8 160 7.8 180 10.5 200 13.8 240 13.8 280 18.4 320 18.4 Capacity Correction Factors TD R22 Evaporating Temperature C DT1-40 -35-30 -23-18 -12-8 -7-1 + 5 6 0.57 0.60 0.64 0.66 0.70 0.72 0.75 0.76 0.79 0.8 7 0.67 0.70 0.74 0.77 0.81 0.84 0.88 0.88 0.92 0.9 8 0.76 0.80 0.85 0.88 0.93 0.96 1.00 1.01 1.05 1.1 9 0.86 0.90 0.96 0.99 1.05 1.08 1.13 1.14 1.18 1.2 10 0.95 1.00 1.06 1.10 1.16 1.20 1.25 1.26 1.31 1.4

FV & FVH DIMENSIONS AND WEIGHTS Dimensions Weights kg E 8 & 6 mm 4 mm E Ducted Model H1 H2 W D G FH FL Aerofoil Axial F Al Fins Cu Fins Al Fins Cu Fins 60 1615 2053 2390 1035 838 915 1930 100 360 920 430 523 412 517 70 1767 2285 2390 1035 918 1067 1930 100 435 1000 465 574 445 568 80 1513 2030 3355 1035 918 812 2895 100 435 1000 564 689 543 683 90 1615 2133 3355 1035 918 915 2895 100 435 1000 594 733 569 726 100 1716 2234 3355 1035 918 1016 2895 100 435 1000 620 776 594 769 120 1920 2438 3355 1035 918 1220 2895 100 435 1000 723 910 694 904 140 1818 2336 4165 1035 918 1117 3705 100 435 1090 824 1043 790 1036 160 1970 2578 4165 1135 1008 1270 3705 100 435 1090 901 1150 864 1144 180 2122 2730 4165 1135 1008 1422 3705 100 435 1090 929 1208 889 1202 200 2326 2934 4165 1135 1008 1626 3705 100 435 1090 995 1313 950 1308 240 2630 3238 4165 1135 1008 1930 3705 100 435 1090 1146 1524 1094 1519 280 2630 3238 4730 1135 1008 1930 4270 100 435 1090 1338 1774 1280 1770 320 2885 3483 4730 1135 1008 2185 4270 100 435 1090 1440 1932 1374 1928 Dimensions E Model FVH Model FV W FL W G FH 100 H2 50 FH 250 H1 625 Fan Section Detatchable AIR FLOW CL Models 140-320 1 1/ 2" FL 250 BSP'M' drain F AIR FLOW CL Models 140-320 1 1/ 2" BSP'M' drain D D

HOW TO ORDER. FVH 160 4 ED2 PH AE CU/AL WP Model FV or FVH When ordering we need to know the following: No Fin spacing Defrost ED 1 ED 2 HGE HGD RCE RCD PH Evaporator Duty Refrigerant Evaporating Temperature Room Temperature Liquid temperature before TEV. Connection Handing - looking at coil face (LACF) Fans AE Standard Aerofoils DA Shortcase Axial Tube / Fin Material Cu/Al Cu/Al Cu/Cu Cu/Cu/Et Copper Tubes with Aluminium Fins Copper Tubes with Polyester Coated Aluminum Fins Copper Tubes with Copper Fins Copper Tubes with Copper Fins Electrotinned Casing WP White Powder Coated Galvanised Sheet Steel PG Plain Galvanised Sheet Steel ST T304 Watch Case Stainless Steel AL NS4 Marine Grade Aluminium Cowls Fan Cowls Dampers Butterfly Duct Dampers Ducts Ducts to x m o/a height HEATING & COOLING COIL PRODUCTS LTD. Unit 21 Wingate Road, Fort Brockhurst Ind Estate, Gosport, Hampshire, PO12 4DR Tel: 02392 501431. Fax: 02392 529272 E-mail: sales@handccoils.co.uk WEB: www.handccoils.co.uk Bulletin FV,FVH 1/3/07 We reserve the right to change in whole, or in part, the specification detailed in this brochure without prior notice, and when necessary, to achieve continuous production, to use alternative competitive designs of sub contract components made by various manufactures.