THE SUMMARY OF COMPANY 1- Company Name : Sepand Tahvieh. 2- Established: Address:

Similar documents
50A KP 70A KP 90A KP 120A KP 150A KP 210A

Product Line Introduction. Karl Zhang Technical support engineer

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

CHAPTER 6 CONDENSING UNITS

ACMVTECH HIGH EFFICIENCY UNITARY AHU

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

Modular Air Cooled Scroll Chillers

Hyperchill. water chillers

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98


PRODUCT GUIDE

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

MovinCool Classic and Classic Plus Series. The Portable Spot Cooling Solution

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Motor-driven condensing units MTE MTE R-410A

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Mechanical Systems Mechanical Systems

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

KDIR TROUBLESHOOTING. Middle Static Pressure Duct Type SERIES

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. HEAD OFFICE-GROUND FLOOR RAHEJA CHAMBERS, FREE PRESS JOURNAL MARG, NARIMAN POINT, MUMBAI-21

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

AIR COOLED CONDENSERS

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Chapter 10. HVAC System


AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Direct Drive Truck Units. A complete line of refrigeration units for a wide variety of vehicle chassis and applications.

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Introduction of Panasonic CO2 refrigeration system. Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Hi-Pres Cooling Products Catalogue. Product Catalogue

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

VariCool VAV Engineering Guide

ShuttleAIRE Systems. A complete range of HVAC systems for small and medium sized vehicles.

Industrial cooling systems LT

Condensing Units CUS 15-60

Roof top SPACE RPC 450Z R407C M011

H4T R410A. refrigerant

Advance Split

AQUAHEAT ADVANCE SPLIT

RIGID DC LIQUID CHILLER

commercial refrigeration products

SARAVEL Minichill PACKAGED LIQUID CHILLERS

Table of Contents. 2 aermec.us

Air-Cooled Condensing Units with Compact Screw Compressors

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

COOLPLUS KENYA LIMITED. The "Only Manufacturer" of Uninterrupted Cold Stores & Trough Cooling Systems for post Harvest solution Recycling.

Advance Release September 2009

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Condensing Units w/ Screw Compressors

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

CENTRAL SPLIT UNIT UNIC

Roof top SPACE RPC 315Z R407C MA00

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Energy saving refrigeration dryers SCFM. Purifying your compressed air, increasing your efficiency.

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H. Horizontal packaged air conditioners kw FLATAIR AGU-MSL E. lennoxemeia.

MULTIPLE COMPRESSOR SYSTEMS COMPRESSOR PACKAGES ORIGINAL MANUFACTURED EQUIPMENT. Multiple Compressor Systems BA AUS

Microchannel Solutions by ThermoKey. Core Remote Condenser Liquid Cooler

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Modular Air-cooled Chillers

Air Cooled Packaged Systems AIRAH Back to Basics

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

COMPANY PROFILE 2016

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Classic 10. Self-contained and portable, the Classic 10 requires little or no installation, simply roll it in, plug it in and turn it on.


DEi COMPRESSED AIR & GAS TREATMENT. Purifying your compressed air, increasing your efficiency.

SUSTAINABILITY WITH HIGH DANISH QUALITY

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ

AIR COOLED CONDENSING UNIT

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

Air-Cooled Water Chiller Air-Cooled Water Chiller with Heat Pump Option 3~30 Tons

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

High temperature air-to-water heat pumps

EN-CV: LHCb SciFi Common chiller. Martin Doubek September 25, 2017

HERO SERIES-DC INVERTER HEAT PUMPS

C13-Series. Unique Solutions for All-Indoor HVAC Projects

GENERAL INFORMATIONS

Transcription:

Rolling Stocks Air conditioning i Systems

THE SUMMARY OF COMPANY 1- Company Name : Sepand Tahvieh 2- Established: 1997 2- Address: Factory: Factory: No.71, Shemshad 6 Alley, Shemshad Ave, Shaghayegh SQ, Nasir Abad Industrial Zone, Saveh Road, Tehran/Iran Tel: +98 21 56393695 Fax: +98 21 56393698 Email: info@sepandtahvieh.com www.sepandtahvieh.com 3- President: Vahid Balouti 4- Type of industry: Manufacturing of Rolling Stock Air-conditioning systems and equipments Th li f b i 5-The line of business: - Under Frame Air- conditioning System - Roof mounted Air- conditioning System - Locomotive Driver's Cab Air- conditioning System - Locomotive Static Inverter Air- conditioning System - Diesel Generator Air- conditioning System - Automatic Shut On-Off Toilet System - Electrical Cabinet

Roof packaged Air conditioning Modules With the continuing development in hermetic compressor technology and the introduction of environmentally friendly refrigerants, roof packaged air conditioning is increasingly becoming the choice of both coach builder and train operator as the most convenient and cost effective method of providing air conditioning to passengers. Sepand Tahvieh range of roof package units is considerable with cooling capacities ranging from 15kw to a massive 42kw. RMP units can be used individually or in pairs to cover virtually all cooling requirements likely to be necessary to provide luxurious air conditioning to passenger saloon areas. All Modules are ideal for both new vehicles and for retrofit to existing cars. Their fully stainless steel construction combined with all copper heat exchanger coils makes them suitable for the most arduous of climates. The use of fully hermetic compressors makes the unit virtually it maintenance-free between major overhauls. Twin compressors employed within individual refrigeration circuits allows independent compressor operation under thermostatic control or in the unlikely event of compressor failure or refrigerant leakage. Air filters are easily accessible from within the car and can be changed in seconds.

We offer another Sepand Tahvieh Co roof mounted A/C model which is so suitable for train set and LRV and any other passenger wagon which weight of A/C package is so important. TRS roof mounted unit is considerable with cooling capacities ranging from 28kw to amassive 42kw. Advantages of TRS A/C unit: - High reliability - Totally self-contained, hermetically sealed system - Environmentally friendly refrigerant - A wide range of capacities offered within one low profile design - Easy installation and low maintenance - Ideal solution for retrofit applications as well as new cars Standard Features: - Hermetic refrigeration circuits maximize reliability. - Efficient scroll compressors offer greater reliability, reduced power consumption and lower noise levels. - Features latest microprocessor control system. Readily adaptable to customer s preferred refrigerant. - KW for KW, the lightest air conditioning unit in the industry.

There is the other model which the air handling units with their fans, evaporators, heating batteries, and filters, are located in the roof area. The compressor and condenser can be installed underneath the car. The air handling unit for roof installation has a particularly low profile in order to lose as little ceiling height as possible. The fan (a silenced version) with 2 radial impellers, evacuates the air and passes it via an evaporator and an electric heating battery into the roof ducts. The compressor unit forms the core of the refrigeration circuit. The compressor can be semi-hermetical or open, depending on the type of power supply. We only use proven series production units from well-known compressor manufactures, or in accordance with customer s particular requirements. Under normal circumstances, the compressor unit is fitted with a capacity control. The driving motor is supplied according to existing power supply and usually incorporates overload protection. The condenser robust axial fans refrigerant collecting vessels and filter dryers, complete with the special finned heat exchangers. To facilitate cleaning of the heat exchangers, the fans and bottom plates can be swung aside with a few easy hand movements.

Under FRAME Air Conditioning System This system is formed of three individual sections which consist of Compressor section, Condenser section and Air handling section and connection of units is by units is by special pipes and flanges, therefore installation and dismounting of the system are easily possible. All of the sections are under frame mounted.

This system operates in high ambient temperature up to +50 C with high condense temperature up to +65 C. At this system has been used of refrigerant R 134a (recommended by international associations and for environmental protection) and using of this refrigerant is one of the advantages of this system in comparison of its foreign analogous (which has used of refrigerant R 12)

By using of very perfect and exact control system Sepand Tahvieh Air conditioning systems have ability of adjusting temperature in each of compartments individually and by selecting of passengers between 22 C to 26 C. also the unit can operate in all seasons of year in temperature range between -25 C to +50 C for outside air. According to customer order Sepand Tahvieh control system could be delivered as microprocessor systems and PLC.

Driver s Cab Air Conditioning Systems With locomotive operators increasing efforts to improve drivers environmental conditions and, in consequence, reduce fatigue symptoms, Air Conditioning of Drivers Cabs has become a normal factor to ensure both clean, fresh air at the right temperature. Sepand Tahvieh range of Cab Air Conditioners have been designed to meet a wide range of operators requirements and environmental conditions.

Locomotive Static ti Inverter Air conditioning i System : This Air conditioning System is designed and manufactured for producing of standard and suitable temperature of Locomotive static inverter.

This system consist two main unit one out door unit which is installed on the roof of locomotive and the other indoor unit which is installed in the locomotive and on the inverter.

In manufacturing of all systems we use special equipments for security of passenger s and units in cooling and heating modes. Sepand Tahvieh uses of good quality equipments with high credit brands from well-known European and Western sources. For example compressor from Bitzer (Germany) and Maneurope (France) and Valves from Danfoss (Denmark) and Alco (U.S.A). Sepand Tahvieh Co. as up to 10 years study, design and manufacturing Rolling stock A/C systems is up to date of knowledge of designing and manufacturing. We use the suitable software for calculation of heating and cooling loads and designs of equipments and also designs of structure, FEA modeling, sheet metal design, thermal system performance and balancing.

AUTOMATIC SHUT ON-OFF TOILET SYSTEM Also Sepand Tahvieh has good activities in Environmental Engineering and also it can deliver suitable and economic toilet system for passenger coaches. Not only AUTOMATIC SHUT ON-OFF TOILET SYSTEM is according Rolling Stock Standard and with good technical specifications but also it is so economic and suitable for any passenger wagon without toilet system.

Resume Here is some activities of Sepand Tahvieh Co. in the field of air-conditioning systems in railway Industry: Designing and fabricating the first Air-conditioning system for passenger coaches in Iran, according to Wagon Pars Co. order. suitable for climate conditions in Iran, by using R134a and with confirmation of Wagon Pars Co. and RAJA Co.(Iranian Railway) and registration in Industrial Ownership Administration after performing all the tests in accordance with standards. Designing and fabricating Air-conditioning system for locomotive driver's cab in, according to the contract with Research center of Railway of Islamic Republic of Iran, suitable for using in GM and GE locomotives and other similar locomotives, compatible with climate conditions in Iran. Mass production of Under Frame Air-conditioning system- 25 set passenger coaches project for W.P.Co. (First Phase).

Designing Air-conditioning system suitable for roof installation and compatible with operation in Bangladesh climate conditions according to the order of R&D department of Wagon Pars Co. Designing Air-conditioning system for train sets according to the order of Siemens Co. Designing Air-conditioning system for 200 Cuba Project according to the order of W.P. Co. Designing Air-conditioning system for Passenger Coach according to the order of GPIG Co. Designing Air-conditioning system for Diesel Generator wagon. Designing Air-conditioning system for Locomotive Driver Cab to the order of Syrian Railway (110 V /DC). Negotiation with Yugoslavian Gosa Co. in the field of Air-conditioning systems passenger coaches and visiting the manufacturer and productions of our company.

Installation and operation of 23 units Air conditioning system on S.G.P wagons of W.P.Co. Mass production of Under Frame Air-conditioning system- 50 set passenger coaches project for W.P.Co. (Second Phase) Fabricating of Under Frame Air-conditioning system and other equipments - 50 set passenger coaches project for W.P.Co. (Second Phase) Design,Manufacturing and fabricating of locomotive static inverter Air conditioning system for Tehran Metro Co. Manufacturing of many parts of Air Handlings,Condensers, Compressors, Fresh Air units, to the order of RAJA Co.

Design,Manufacturing and fabricating of split rooftop Air conditioning system for joupar Co. Design,Manufacturing and fabricating of Air conditioning system for IRICo. Design,Manufacturing and fabricating of Air conditioning system for Mahtab Seir Jam Co. Design,Manufacturing of Air conditioning system for Noandishan Rail Iranian Co. Design,Manufacturing and of Air conditioning system for Rail Seir Kosar Co. Design,Manufacturing and fabricating of Air conditioning system for Rahsaz Gostar Mehr Co. Procurements of parts and equipments of Air conditioning units for Ehia Sanat Co and Joupar Co. In addition, this company is in the stage of local manufacturing of sanitary systems for passenger coaches,

Companies in contract IRICo. Taw Co. Raja Co. Joupar Co. Ehia Sanat Co. Wagon Pars Co. Rail Seir Kosar Co. Metro of Tehran Co. Mahtab Seire Jam Co. Rahsaz Gostar Mehr Co. Noandishan Rail Iranian Co Iranian Railway Traction Power Co. Research center of Railway of Islamic Republic of Iran.,

Under Frame Mounted First Phase of manufacturing Customer: Wagon pars Co. Spec: 36 Kw

End Users: 1- Raja Co. 2- Joupar Co.

Under Frame Mounted Second Phase of manufacturing Customer: Taw Co. Spec: 43 Kw End user: Raja Co.

Factory: No.71, Shemshad 6 Alley, Shemshad Ave, Shaghayegh SQ, Nasir Abad Industrial Zone, Saveh Road, Tehran/Iran Tel: +98 21 56393695 Fax: +98 21 56393698 Email: info@sepandtahvieh.com www.sepandtahvieh.com