YES Mini VRF Series RESIDENTIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST

Similar documents
DC Inverter Smart VRF Products(R410A)

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Product Brochure Smart Power. Low Profile Ducted

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Product Brochure 2017

Ultimate VRF System R410A, 50Hz

A more comfortable, safe and sustainable world

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Ducted inverter reverse cycle air conditioning

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

Just feel well. 2017/2018 Air conditioning

Heat Pump Air Conditioning Systems

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Modular Air Cooled Scroll Chillers

Product Line Introduction. Karl Zhang Technical support engineer

Residential and Light Commercial Ductless Systems Catalog

R410A VRF Indoor Unit 50Hz AC Series

Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Inverter Wall Mounted Series

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Inverter Ducted Air Conditioners

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Inverter Ducted Air Conditioners

3 rd Generation of VRV. The professional solution for your professional project

2017 LINE UP MINI SPLITS CATALOG

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15

Air-cooled modular Chiller. Nick Technical Engineer

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

Air Conditioners Heating & Cooling

VENTILATION. Effective heat exchange and fresh air ventilation

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Air Conditioners Heating & Cooling

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Light commercial range. Passion at work

Innovative air conditioning

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

Inventor of the Inverter Digital Inverter System

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Contents. Introduction. Full DC Inverter VRF 2. Small Capacity Units 5. Advantage 7. Benefits 12. DX-LINE Mini 28. Indoor Units 32

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

DC inverter Outdoor-air Processing unit (GC )

Air Cooled Scroll Chiller

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group

AHU Plus. DX Air Handling Units

All DC Inverter Multi VRF

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Chilled Water Precision Air Conditioner for Critical Application

Integrated VarIable refrigerant flow ahu/pau (r410a)

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Product Catalog. DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h

Compact design & easy maintenance

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

2 &3-4 Head Multi System

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Air Conditioning System

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

Ceiling Mounted Cassette Unit

Inverter console UFV system. Compact design and personalised air flow selection

HVS, Hydro Variable System

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Variable Refrigerant Flow (VRF) Multi-Zone Systems

A single answer for multiple zones.

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

air systems Roomtop RTC-RTH 15 to 30 - L

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Single Fan MiNi VRF Apartment Ready

Transcription:

YES Mini VRF Series RESIDENTIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST

Table of Contents Serving your needs since 1874 1 Product Benefits 3 Product Features 4 Product Functions 6 Product Technologies 9 Smart Control 10 Indoor Units 14 Product Portfolio 21 Product Nomenclature 22 Product Specifications 24

Serving Your Needs Since 1874. A century of innovation Established in 1874 in York, Pennsylvania, YORK has helped our customers meet their temperature control needs for over a century. Now a Johnson Controls brand, YORK continues to benefit customers through research that has gone on to claim several significant firsts in design and innovation. Johnson Controls is able to provide our customers with the best temperature control solutions available around the world today. Pioneer in Inverter technology Our customers can be assured that they will enjoy the benefits of the latest technology when they choose a Johnson Controls product, as YORK has always been at the forefront of adopting new technologies for their offerings. From being the first to offer a low pressure VSD unit in 1979 to introducing the inverter technology in the 21st century, YORK has demonstrated its pioneering spirit. Leader in reliability When constructing products, YORK places our customers needs as the top priority of our design process. Significant Milestones 1935 First to develop a successful single-room air conditioner 1954 First to offer year-round air-conditioning 1979 Launched the first Low Pressure VSD Driven Centrifugal Chiller 2004 Launched the first VSD Driven Air Cooled Screw Chiller 2005 Applied VSD in YORK Industrial Refrigeration Screw Chiller 2011 Launched the YES Mini Residential Inverter VRF, Magnetic VSD Centrifugal Chiller, VSD Driven Water Cooled Screw Chiller 2012 Launched the YES Slim Residential/ Commercial Inverter VRF, YES Super Commercial Inverter VRF Our inverter VRF units are produced using state-ofthe-art lean manufacturing techniques, and rigorous quality testing is implemented at every step of the manufacturing process, before they are shipped to customers. YES Mini VRF Series 1

Endorsed by Iconic Buildings. YORK s HVAC systems have been installed in many of the world s most famous landmarks. YORK makes systems for structures of all sizes that bring innovation, comfort and design wherever people live, work and play. 2 YES Mini VRF Series

Product Benefits YORK Variable Refrigerant Flow (VRF) At Johnson Controls, we always seek to anticipate what customers are looking for and strive to provide the temperature control systems that will meet their myriad of needs. YORK VRF air-conditioners offer customers a range of benefits that is unparalleled in the air-conditioner market. Energy Efficient Customers looking to save money will be delighted to know our air-conditioners can help reduce costs as the highly energy-efficient VRF units will help you decrease the power you use. Wide Ambient Range Customers can take comfort in knowing that our inverter VRF air-conditioners can operate in extreme weather conditions, running safely even when the ambient temperature is up to 52 0 C for cooling or -20 0 C for heating. 48 to 52 0 C cooling or -15 to -20 0 C heating will be running at intervals. Smart Control Customers can take more effective control of their air-conditioners with a variety of technology tools available for our units. Our advanced suite of control solutions include: three types of touch screen controllers, smart home connection and building automation systems using the Metasys software. Versatility We understand that no two customers are the same. That s why we ve designed our air-conditioning systems to be versatile enough to meet our customers differing needs. From product selection to installation to commissioning, YORK YES Series offers impressive flexibility. Greater Comfort We know that enjoying comfort at the right temperature is one of our customers foremost desires. We have the technology to deliver that comfort, including a BLDC (Brushless Direct Current) fan motor with adjustable speeds, anti-vibration and soundinsulation technology. YES Mini VRF Series 3

Product Features Cooling m 5m 70 Part ceiling Narrow corridor installation Heating JCI YES-Mini Outdoor Fin General Louvered Fin Environmental Protection Our highly energy efficient Inverter VRF units provide environmental protection by Night Mode using the eco-friendly Cooling R410A refrigerant. Night Mode Heating Outdoor to be set at night mode Lower fan speed during overnight operation JCI YES-Mini Outdoor Fin General Louvered Fin Wide Ambient Range Indoor EXV 52C -20C Three-row design for models 35/40/50/60 Low-pressure Sensor Capacity-Priority Mode Capacity-Priority Mode High-pressure Sensor With wide ambient temperatures ranging from 52oC in cooling mode to -20oC in Outdoor to be set at capacitypriority mode Load needs priority heating mode, the air-conditioning units can be used in various environments. Time Heating Capacities Inlet/outlet Temperature of the Heat Exchanger Durations Outdoor Temperature 1.8kW~5.3kW 0~30Pa General Air Conditioner YES-mini 15~80Pa 6.6kW~11.5kW 15~100Pa 14kW~17.5kW 3-row Heat Exchanger 1. Diagnostic Kit 2. Outdoor Control Board Indoor EXV Cooling 3. Computer Software Heating Three-row design for models 35/40/50/60 Communication cables Power cables Heating JCI YES-Mini Cooling Outdoor Fin General Louvered Fin Touch Screen Wired Control JCI YES-Mini Outdoor Fin General Louvered Fin Take control of your system with our smart touch screen wired controller, which is Inlet/outlet Temperature available in different colours to suit your own personal taste. It also features a built-in of the Mode Heat Night Exchanger signal receiver. Night Mode Outdoor to be set Ceiling (Unit: Three-row Heat-Exchanger 1. Diagnostic Kit Capacity-Prior Our units are built with a three-row heat-exchanger, improving unit performance even Indoor EXV Three-row design for models 35/40/50/60 Three-row design for models 35/40/50/60 Lower fan speed du operation Low-pressure Sensor Capacity-Priority M High-pressure Sensor Outdoor to be set priority mode under extreme temperatures. Load needs priority Ind 2. Outdoor Control Board Time Heating Capacities Three-row design for models 35/40/50/60 Field Wiring Design Inlet/outlet Temperature of the Heat Exchanger The field wiring design on our outdoor units provides convenience in wiring connection 3. Computer Software Durations General Air Conditioner through the availability of a detachable handle on its side. This also prevents noise YES-mini problems and damage to the exteriror. 1. Diagnostic Kit 2. Outdoor Control Communication Board Power cables Outdoor Temperature Inl Tem of Ex cables 3. Computer Software 1. Diagnostic Kit Communication cables Power cables 4 YES Mini VRF Series 3-row Heat Exchanger 2. Outdoor Control Board 3. Computer Software

Rare-earth Permanent Magnet DC Inverter Compressors The rare-earth permanent magnet DC inverter compressors in our units are capable of forming powerful and permanent magnetic fields, which enables the compressor to operate at high efficiency when switched on. The rotors in these compressors are fixed with slip-rings to seal the cylinder, thereby reducing abrasion and extending the lifespan of the compressor. Noise Reduction Technology The noise reduction technology, made possible by DC scroll inverter compressors, BLDC fan motor with adjustable speeds, anti-vibration and sound-insulation technology, ensures that the air-conditioners operate quietly by cutting down the operational noise levels. YES Mini VRF Series 5

Product Functions Intelligent Piping Length Adaptation This system consists of a high-pressure sensor, low-pressure sensor and real-time temperature monitor, measuring compressor discharge and suction temperatures, indoor Heating evaporator temperatures, as well as tube temperatures in the heat exchanger. This allows the operating pressure and compressor operating frequency to be automatically adjusted under different piping length conditions. eral Louvered Fin Indoor EXV Low-pressure Sensor High-pressure Sensor Two Quiet Operation Modes Part ceiling Part ceiling The availability of Night Mode and Capacity-Priority Mode allows for quiet operations throughout the day. The Night Mode prompts the fan to run at lower speeds during Heating Capacities Time overnight operations, while the Capacity-Priority Mode takes into consideration Inlet/outlet surrounding air Temperature fluctuations to adjust fan speed. of the Heat Exchanger Durations Outdoor Temperature 2. Outdoor Control Board Indoor EXV Low-pressure Sensor High-pressure Sensor Indoor EXV High-pressure Sensor 3-row Heat Exchanger Capacity-Priority Mode Outdoor to be set at capacitypriority mode Outdoor to be set at capacitypriority mode Load needs priority Load needs priority Durations Durations Time Heating Heating Capacities Capacities 6 YES Mini VRF Series Outdoor Temperature Outdoor Temperature Night Mode Outdoor to be set at night mode Capacity-Priority Mode Capacity-Priority Mode Capacity-Priority Mode 3. Computer Software Inlet/outlet Temperature Inlet/outlet of the Heat Temperature Exchanger of the Heat Exchanger General Air Conditioner YES-mini Outdoor to be set at night mode Lower fan speed during overnight operation Lower fan speed during overnight operation 1. Diagnostic Kit Low-pressure Sensor Night Mode Night Mode Night Mode General Air Conditioner General Air YES-mini Conditioner YES-mini Time 15~80Pa 15~80Pa 15~100Pa 15~100Pa 3-row Heat Exchanger 3-row Heat Exchanger 0~30Pa 0~30Pa 6.6kW 6.6kW 14kW~ 14kW~

JCI YES-Mini Outdoor Fin General Louvered Fin Cooling Heating Three External Static Pressure (ESP) Settings JCI YES-Mini General Louvered Fin A 3-4HP outdooroutdoor unit withfina single fan can reach external static pressures as high as 30 Pa, while a 4.5-6HP outdoor unit with two fans can reach 40 Pa. Installing an air duct to redirect airflow is feasible with the ESP setting. Indoor EXV Three-row design for models 35/40/50/60 Inlet/outlet Temperature of the Heat Exchanger Indoor E Three-row design for models 35/40/50/60 1. Diagnostic Kit Three Approaches for Address Setting The system offers three system setting approaches for ease of testing and installation of 2. Outdoor Control Board units: Inlet/outl Temperatu of the He Exchange Auto address setting with diagnostic kit Auto address setting with outdoor unit 3. Computer Software Auto address setting on computer 1. Diagnostic Kit Communication cables Power cables 2. Outdoor Control Board 3. Computer Software Communication cables Maximum Safety Power cables Our units guarantee safety by having in place: m 5m 70 Part ceiling Narrow corridor installation 1. High pressure/low pressure protection Heating 1.8kW~7.1kW 8.0kW 2. Compressor internal overload protection General Louvered Fin 9.0kW~11.2kW 2.8kW 4.5kW 5.6kW/7.1kW 3. Time delay for compressor restart, among other protection systems Night Mode Night Mode Outdoor to be set at night mode Top air outlet Lower fan speed during overnight operation Side air outlet Cooling: good He good Cooling: weak He good B A York air outlet YES Mini VRF Series 7 Cooling: good He weak Capacity-Priority Mode Indoor EXV Low-pressure Sensor Capacity-Priority Mode High-pressure Sensor Outdoor to be set at capacitypriority mode Heating Capacities Load needs priority Inlet/outlet Temperature of the Heat Exchanger Durations Time 0~30Pa 15~80Pa 1.8kW~5.3kW 6.6kW~11.5kW 14kW~17.5kW 60

Heating Automatic Fault Alarm eral Louvered Fin The wired controllers of the indoor and seven-segment LED displays of outdoor units automatically display information of any system failure, which makes trouble-shooting Night Mode Night Mode problems easier. Outdoor to be set at night mode Lower fan speed during overnight operation Intelligent Defrost By monitoring outdoor temperatures, inlet/outlet temperatures of the heat exchanger, as well as the duration for intelligent defrost, the system can efficiently conduct defrost cycles. Heating Indoor EXV Low-pressure Sensor Capacity-Priority Mode High-pressure Sensor This also eliminates the problem of dust affecting the heat exchange capacity and possibly triggering an auto-defrost, which thus enables uninterrupted heating. Inlet/outlet Temperature of the Heat Exchanger Durations Outdoor Temperature Outdoor to be set at capacitypriority mode Load needs priority Time Heating Capacities eneral Louvered Fin Capacity-Priority Mode Night Mode Night Mode Outdoor to be set at night mo Lower fan speed during overni operation General Air Conditioner YES-mini 3-row Heat Exchanger Capacity-Priority Mode 1. Diagnostic Kit Indoor EXV Low-pressure Sensor Capacity-Priority Mode High-pressure Sensor Outdoor to be set at capacitypriority mode 2. Outdoor Control Board Load needs priority Refrigerant Recovery If the indoor or outdoor unit fails in the system, the refrigerant may be recovered to Time Heating Capacities 3. Computer Software reduceinlet/outlet its wastage. Temperature of the Heat Exchanger Outdoor Control Board with Seven-Segment LED Display General Air Durations Conditioner YES-mini Our outdoor units feature three seven-segment LED displays on their control 3-row boards to show the Outdoor Heat Temperature 1. Diagnostic Kit 2. Outdoor Control Board 3. Computer Software 8 YES Mini VRF Series Exchanger system s relevant information for greater diagnosis efficiency during servicing.

Product Technologies 180 DC Inverter Driver We adopted the 180 inverter driver control to reduce motor vibration and noise while enhancing the compressor operating frequency range. Special fresh air intake design for drivers (models 45-60) Our variable speed drivers have incorporated a special fresh air intake design to reduce the temperature of the driver. This enables the variable speed driver to operate at higher speeds and at higher ambient temperatures. Without Fresh Air Intake With Fresh Air Intake Sub-Cooling Design A sub-cooling coil is integrated in the outdoor heat exchanger to enable sub-cooling and reduce the capacity loss in the event of using long piping (length of piping varies according to the apartment size, shape and number of indoor units). Electronic expansion valve and check valve throttling On top of having an outdoor electronic expansion valve for heating purposes, our YES Mini series also comes with a check valve parallel to the electronic valve, so that the refrigerant may enter through it at cooling mode, thereby improving the life of the valve. Pressure and temperature sensors The outdoor units come equipped with high and low pressure sensors, as well as discharge, suction, heat exchanger and ambient temperature sensors. When used in combination, they provide stable and effective system operations. New low resistance fan grille Our specially designed leaf shape fan grille reduces air resistance, adjusts the air discharge direction and avoids short circuit of return and discharge air. This improves the noise data, noise quality and the unit efficiency. YES Mini VRF Series 9

Smart Control Individual & Group control The indoor units in our YES Series can be controlled using wired and wireless controllers. Moreover, the wired controllers include a group control function and can connect up to four indoor units. Wired Controller Wireless Controller Group Control Group Control Individual Control The touch screen wired controllers come in a range of colours to suit your personal taste, and is equipped with TiO 2 control and wireless controller receivers. Gray Sky blue Green Brown 10 YES Mini VRF Series

On/Off Controller Our touch screen controllers can connect up to 256 indoor units or four VRF systems, and can switch those within the same zone on or off simultaneously. ** YDHW/YDCC can't connect to on/off controller. ON/OFF controller which can support Modbus or BACnet protocol for different applications (need to select the protocol mode). Central on/off control at the entrance/exit Central Controller Our seven-inch touch screen central controller can be mounted on the wall easily and connects up to 1,024 indoor units/ 512 groups/ 128 zones/ 16 VRF systems. In addition to having the same control functions as the wired controller, it also has a weekly schedule function. ** YDHW/YDCC can t connect to central controller. Central controller can support Modbus or BACnet protocol for different application (need to select the protocol mode). YES Mini VRF Series 11

Door Card Function The control boards in the YES indoor units come with a door card on/off signal function and feature two selection modes, which may be chosen using the door card and signal interface communication. Mode 1: The system automatically returns to the last operation mode when the card is inserted. Door Card Door Card Insert the door card Pull out the door card Mode 2: The system needs to be switched on manually when the card is inserted, so as to reduce electricity wastage. Door Card Door Card Insert the door card Door Card Pull out the door card 12 YES Mini VRF Series

BAS Connection Our YES Series can be connected to the Building Automation System to allow an integrated smart control solution. ** YDHW/YDCC can t connect to BAS connection. YES Mini VRF Series 13

Indoor Units Compact Ducted Indoor Unit Part ceiling 700mm 450mm Narrow corridor installation Compact design With a height of just 200mm and depth of 450mm, its compact size makes installation ideal for narrow spaces such as corridor of bedrooms or hotel rooms. Flexible air return The detachable air return baffle enables the direction of air return to be adjusted either downwards or backwards. ESP adjustable The adjustable external static pressure of the compact ducted indoor unit supports different installations and generates optimal airflow. 0~30Pa 1.8kW~7.1kW Sleep mode Sleep mode may be selected via a wired controller. Ceiling (Unit: mm) Drainage pump available The compact ducted indoor unit fits in the narrowest of spaces where the drainage pump is not required. However, a drainage pump is available in case there is enough room in the ceiling and the drainage distance is long. 14 YES Mini VRF Series

Low Static Ducted Indoor Unit Part ceiling 700mm Narrow corridor installation Compact design With a height of just 200mm and width of 700mm (018 045), its compact size makes installation ideal for narrow spaces such as corridor of bedrooms or hotel rooms. Flexible air return The air return baffle is detachable. The direction of air return can be adjusted during installation, either downward or backward. 1.8kW~7.1kW 8.0kW 9.0kW~11.2kW ESP adjustable The external static pressure of the low static ducted indoor unit is adjustable, supporting different installations and delivering optimal airflow. Sleep mode Sleep mode can be selected via a wired controller. Ceiling (Unit: mm) Drainage pump available The low static ducted indoor unit fits in the narrowest of spaces where the drainage pump is not required. However, if there is enough room in the ceiling and the drainage distance is long, a drainage pump is available. YES Mini VRF Series 15

Ceiling-concealed (Medium Static Ducted) Indoor Unit ESP Adjustable The external static pressure of our ceiling-concealed indoor units is adjustable, which supports different installations and provides optimal airflow. 15~80Pa 15~100Pa 0~30Pa 2.0kW~5.3kW 6.6kW~11.5kW 14kW~17.5kW Sleep mode Sleep mode may be selected via a wired controller. Medium Static Ducted Indoor Unit Flexible installation By using a spiral duct, it is possible to operate the unit in a special type of room and provide comfortable airflow throughout the room. ESP adjustable The adjustable external static pressure of the medium static ducted indoor unit supports different installations and generates optimal airflow. 40~80Pa 40~90Pa 40~120Pa 5.0kW~9.0kW 10.0kW~14.0kW 16.0kW Ceiling (Unit: mm) Drainage pump available The medium static ducted indoor unit can be installed in places where the drainage distance is long, and a drainage pump is available. 16 YES Mini VRF Series

High Static Ducted Indoor Unit Flexible installation By using a spiral duct, it is possible to operate the unit in a special type of room or even several rooms simultaneously while providing comfortable air-flow throughout the rooms. ESP adjustable The adjustable external static pressure of the high static ducted indoor unit supports different installations and generates optimal airflow. 90~175Pa 80~120Pa 5.0kW~9.0kW 10.0kW~14.0kW Ceiling (Unit: mm) Drainage pump available The high static ducted indoor unit can be installed in places where the drainage distance is long, and a drainage pump is available. 2-Way Cassette Indoor Unit 310mm 520mm Complete product line Seven models ranging from 2.8 kw to 11.2 kw are available for selection. 840~1440mm Compact design A standard, compact design of 520 mm depth and 310 mm height is adopted across all models, making installations easier. Max=500mm Standard drainage pump The unit has a standard drainage pump capable of draining up to 500 mm of water, and is ideal for draining condensation over longer distances. Standard YES Mini VRF Series 17

Round-way Cassette Indoor Unit 360 degree circulation Room temperature, airflow and noise control are regulated and maintained throughout the room. Blind angles of air distribution Minified blind angles 360 good air distribution Oblique view Oblique view Elevation view Elevation view Different height setting Wired controllers can be set to normal ceiling mode or high ceiling mode, providing comfort. Oblique view Elevation view Fresh air intake Fresh air can be introduced directly. Fresh air Intake Fresh air Intake 0 good air distribution Brushless Direct Current (BLDC) fan motor With a spiral multi-blade fan and a large-diameter design, the fan noise can be effectively reduced and air volume can be more precisely controlled. stribution Fresh air Intake High efficiency drainage pump The maximum distance between the cassette unit and drainage pump is as high as 750 mm. 18 YES Mini VRF Series ir distribution

High Wall Indoor Unit Complete product line Five compact and attractive models from 2.2 kw to 7.1 kw are available for selection, which are suitable for residential to light commercial applications. Whole Package Design The Electronic Expansion Valve (EEV) fitted inside the unit chamber eliminates the need for external installations. Low noise High efficiency/ low noise motors and fan impellers are adopted to enable quiet operations down to 28dB(A). There is also a standard filter fitted for healthier use. Floor/ Ceiling Indoor Unit 680mm Complete product line Eight models from 2.8 kw to 11.2 kw are available. Floor and ceiling installations are convertible for job sites. 240mm 1245~1670mm Compact design A standard, compact design of 240 mm depth and 680 mm height is adopted across all models, making installations easier. Max=500mm Optional drainage pump The indoor ceiling unit has an optional drainage pump capable of draining up to 500 mm of water, and is ideal for draining condensation over longer distances. Option YES Mini VRF Series 19

Floor-concealed Indoor Unit Complete product line Top air outlet Side air outlet York air outlet Four models from 2.8 kw to 7.1 kw are available. A B Better air distribution Our air outlets are tilted at a 45-degree angle which helps optimize air distribution for cooling and heating. Compact design A standard, compact design of 230 mm depth and 600 mm height is adopted across all models, and is suitable 600mm for floor-concealed installations in cabinets. 230mm 730~1334mm 20 YES Mini VRF Series

Product Portfolio Indoor Cooling Capacities kw Types 1.8 2.2 2.5 2.8 3.2 3.6 4 4.5 5 5.6 Compact Ducted (YDCD) Y Y Y Y Y Y Y Y Y Y Low Static Ducted (YDCP) Y Y Y Y Y Y Y Y Y Y Ceiling-concealed (Medium Static Ducted) (YDCC)* Y Y Y Y Y High Wall (YDHW) Y Y Y Y Floor/Ceiling (YDEC) Y Y Y Y Floor-Concealed (YDVC) Y Y Y 2-Way Cassette (YDDK) Y Y Y Y Round Way Cassette (YDCK) Y Y Y Y Y Y Cooling Capacities kw Types 6.3 7.1 8 9 10 11.2 12.5 14 16 17.5 Compact Ducted (YDCD) Y Y Low Static Ducted (YDCP) Y Y Y Y Y Y Ceiling-concealed (Medium Static Ducted) (YDCC)* Y Y Y Y Y Y Y Medium Static Ducted (YDCM) Y Y Y Y Y Y Y Y Y High Static Ducted (YDCH) Y Y Y Y Y Y Y Y High Wall (YDHW) Y Floor/Ceiling (YDEC) Y Y Y Y Floor-Concealed (YDVC) Y 2-Way Cassette (YDDK) Y Y Y Round Way Cassette (YDCK) Y Y Y Y Y Y Y Y *approximate data Capacity 3HP 3.5HP 4HP 4HP 5HP 6HP Cooling Capacities 8 kw 10 kw 11.2 kw 12 kw 14 kw 16 kw Heating Capacities 9.5 kw 11.2 kw 12.5 kw 12.5 kw 16 kw 18 kw Models YVOH30 YVOH35 YVOH40 YVOH45 YVOH50 YVOH60 YES Mini VRF Series 21

Product Nomenclature Outdoor Certification, Default: No Special Certificate Conditions, Default: Local T1, 1: Export T1 Design Series Number Design Code Structure, H: Horizontal Discharge Power Supply, A: 220V/1PH-50Hz, K: 220-240V/1PH-50Hz Cooling Capacity Code Mode of Operation, H: Heat Pump Outdoor Unit V: Variable Refrigerant Flow (VRF) Air Conditioner Y: YORK E Series Indoor 0 E 3 Condition, 1: Export T1; 3: Export T3 Design Series Number: E Series(R410A) Design Code Power Supply, A: 220V/1PH-50Hz Expansion Device, N: Internal EXV No Drainage Pump, P: Interal EXV With Drainage Pump Auxiliary Electric Heater 0: No Heater, 2: With 2# Heater, 4: With 4# Heater Mode of Operation, C: Cooling Only, H: Heat Pump Cooling Capacity Code in 100W Indoor Unit Type, CD: Compact Ducted, CP: Low Static Ducted, CK: Round-way Ceiling Cassette, CM: Medium Static Ducted, CH: High Static Ducted, DK: 2-way Ceiling Cassette, EC: Floor/Ceiling, VC: Floor Conceal, HW: High Wall D:Variable Refrigerant Flow(VRF) Air Conditioner Y:YORK 22 YES Mini VRF Series

C Series Indoor Units H F L E 2 C 3 Condition, 3: Export T3 Design Series Number: C Series(R410A) Design Code Power Supply, A: 220V/1PH-50Hz Expansion Device, E: Internal Piping, L:Left, R: Rightl Return Plenum, F: With Back Return Plenum and Filter Auxiliary Electric Heater 0: No Heater, 2: With 2# Heater, 4: With 4# Heater Mode of Operation, C: Cooling Only, H: Heat Pump Cooling Capacity Code in 100W Indoor Unit Type, CC: Ceiling-concealed (Medium Static Ducted) D: Variable Refrigerant Flow(VRF) Air Conditioner Y:YORK YES Mini VRF Series 23

Product Specifications YES Mini Outdoor Outdoor Unit Model YVOH30KH YVOH35KH YVOH40KH YVOH45AH YVOH50AH YVOH60AH HP 3.0 3.5 4.0 4.5 5.0 6.0 Power Supply (V/Ph/Hz) 220/1/50 Capacity (kw) Power (kw) Efficiency (W/W) Cooling 8.0 10.0 11.2 12.0 14.0 16.0 Heating 9.5 11.2 12.5 12.5 16.0 18.0 Cooling 2.13 3.00 3.41 3.00 3.88 4.72 Heating 2.31 3.12 3.47 3.12 3.78 4.50 Cooling EER 3.76 3.33 3.28 4.00 3.61 3.39 Heating COP 4.11 3.59 3.60 4.01 4.23 4.00 IPLV (C) 5.25 5.20 5.35 5.35 5.60 5.30 Air Flow (m3/h) Standard 4100 4100 4700 6500 6500 6500 Dimensions (mm) H W D 882 x 995 x 360 1320 x 995 x 360 Weight (kg) Net Weight 90 93 95 110 115 125 Compressor Type Rotary Rotary Rotary Rotary Rotary Rotary Number of Compressor 1 1 1 1 1 1 Power Output (kw) 1.60 2.20 2.50 2.20 2.80 3.40 Refrigerant Type R410A R410A R410A R410A R410A R410A Charge (kg) 2.7 3.0 3.5 3.7 4.5 5.1 Noise (db(a)) Cooling/Heating 48/50 49/51 51/51 51/53 52/55 52/55 Piping (ømm) Liquid 9.52 Gas 15.88 Max. 16.6 20.0 20.0 20.0 30.0 30.0 Current (A) Circuit Breaker 25 25 25 25 40 40 Nominal Cooling 9.8 13.8 15.7 14.5 17.8 21.7 Nominal Heating 10.6 14.3 15.9 15.1 17.4 20.7 Max. Piping Length 70 70 70 120 120 120 Max. Equivalent Piping Length 100 100 100 150 150 150 Piping Length/Height (m) Max. Height Difference between IU/OU (OU above IU) Max. Height Difference between IU/OU (IU above OU) 30 15 15 15 20 20 20 Max. Height Difference (IUs) 15 Ambient Range Cooling ( CDB) Heating ( CWB) -5 52 (Interval Running at 48 to 52 C) -20 24 (Interval Running at -20 to -15 C) Max. Indoor Unit No. 5 7 8 8 10 11 24 YES Mini VRF Series

Compact Ducted Indoor Unit Indoor Unit Model YDCD 018 H0N(P)A YDCD 022 H0N(P)A YDCD 025 H0N(P)A YDCD 028 H0N(P)A YDCD 032 H0N(P)A YDCD 036 H0N(P)A Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 1.8 2.2 2.5 2.8 3.2 3.6 Heating 2.2 2.5 2.8 3.2 3.6 4.0 Power Input (W) 37 37 46 46 48 50 Current (A) Nominal 0.16 0.16 0.2 0.2 0.21 0.22 Air Flow (m3/h) - 350 350 450 450 480 480 ESP (Pa) Dimensions (mm) Standard (min-max) H W D 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 200X700 X450 200X700 X450 200X700 X450 200X700 X450 200X700 X450 200X700 X450 Weight (kg) Net Weight 23 23 23 23 23 25 Noise (db(a)) H/M/L 29/25/23 29/25/23 31/27/25 31/27/25 32/29/27 32/29/27 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.70 6.35/12.70 Drainage DN25 DN25 DN25 DN25 DN25 DN25 Indoor Unit Model YDCD 040 H0N(P)A YDCD 045 H0N(P)A YDCD 050 H0N(P)A YDCD 056 H0N(P)A YDCD 063 H0N(P)A YDCD 071 H0N(P)A Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 4.0 4.5 5.0 5.6 6.3 7.1 Heating 4.5 5.0 5.6 6.3 7.1 8.0 Power Input (W) 70 70 76 106 106 110 Current (A) Nominal 0.3 0.3 0.33 0.46 0.48 0.48 Air Flow (m3/h) - 560 560 750 900 900 990 ESP (Pa) Dimensions (mm) Standard (min-max) H W D 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 0(0-30) 200X700 X450 200X900 X450 200X900 X450 200X900 X450 200 1100 450 200 1100 450 Weight (kg) Net Weight 25 30 34 34 34 34 Noise (db(a)) H/M/L 38/35/32 35/32/29 35/32/29 39/36/32 37/34/31 37/35/32 Piping (ømm) Liquid/Gas 6.35/12.70 6.35/12.70 6.35/12.70 6.35/12.70 9.52/15.88 9.52/15.88 Drainage DN25 DN25 DN25 DN25 DN25 DN25 YES Mini VRF Series 25

Low Static Ducted Indoor Indoor Unit Model YDCP 018H0N(P)A YDCP 022H0N(P)A YDCP 025H0N(P)A YDCP 028H0N(P)A YDCP 032H0N(P)A YDCP 036H0N(P)A Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 1.8 2.2 2.5 2.8 3.2 3.6 Heating 2.2 2.5 2.8 3.2 3.6 4.0 Power Input (W) - 37 37 46 46 48 50 Current (A) Nominal 0.16 0.16 0.20 0.20 0.21 0.22 Air Flow (m3/h) - 350 350 450 450 480 480 ESP (Pa) Standard (min max) 0 (0 30) Dimensions (mm) H W D 200 700 620 Weight (kg) Net Weight 23 25 Noise (db(a)) H/M/L 27/25/23 27/25/23 28/26/24 28/26/24 30/27/25 30/27/25 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7 6.35/12.7 Drainage Piping (mm) DN25 Indoor Unit Model YDCP 040H0N(P)A YDCP 045H0N(P)A YDCP 050H0N(P)A YDCP 056H0N(P)A YDCP 063H0N(P)A YDCP 071H0N(P)A Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 4.0 4.5 5.0 5.6 6.3 7.1 Heating 4.5 5.0 5.6 6.3 7.1 8.0 Power Input (W) - 70 70 76 106 106 110 Current (A) Nominal 0.30 0.30 0.33 0.46 0.48 0.48 Air Flow (m3/h) - 560 560 750 900 900 990 ESP (Pa) Standard (min max) 0 (0 30) Dimensions (mm) H W D 200 700 620 200 900 620 200 1100 620 Weight (kg) Net Weight 25 25 30 34 Noise (db(a)) H/M/L 35/32/29 35/32/29 33/31/28 37/34/30 35/33/29 36/33/30 Piping (ømm) Liquid/Gas 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88 9.52/15.88 Drainage Piping (mm) DN25 Indoor Unit Model YDCP080H0N(P)A YDCP090H0N(P)A YDCP100H0N(P)A YDCP112H0N(P)A Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 8.0 9.0 10.0 11.2 Heating 9.0 10.0 11.2 12.5 Power Input (W) - 138 206 260 260 Current (A) Nominal 0.60 0.90 1.25 1.25 Air Flow (m3/h) - 1200 1500 1700 1700 ESP (Pa) Standard (min max) 15 (0 40) Dimensions (mm) H W D 200 1100 620 220 1450 620 Weight (kg) Net Weight 34 48 Noise (db(a)) H/M/L 39/36/31 39/36/31 41/37/33 41/37/33 Piping (ømm) Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 Drainage Piping (mm) DN25 26 YES Mini VRF Series

Ceiling Concealed (Medium Static Ducted) Indoor Indoor Unit Model YDCC 020H0FLEA YDCC 025H0FLEA YDCC 034H0FLEA YDCC 045H0FLEA YDCC 053H0FLEA YDCC 066H0FLEA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.0 2.5 3.4 4.5 5.3 6.60 Heating 2.20 3.00 3.90 4.95 5.80 6.80 Power Input (W) - 40 55 75 100 110 185 Current (A) Nominal 0.35 0.35 0.40 0.46 0.52 0.96 Air Flow (m3/h) - 380 450 600 800 930 1200 ESP (Pa) Standard (min max) 15 (0 30) 15 (15 80) Dimensions (mm) H W D 226 855 602 226 1055 602 226 1175 602 245 1475 576 Weight (kg) Net Weight 20 20 23 25 25 32 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88 Drainage Piping (mm) DN25 Indoor Unit Model YDCC 078H0FLEA YDCC 095H0FLEA YDCC 115H0FLEA YDCC 140H0FLEA YDCC 175H0FLEA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 7.80 9.50 11.5 14.0 17.5 Heating 8.20 11.0 13.0 16.5 19.0 Power Input (W) - 215 270 300 420 510 Current (A) Nominal 1.08 1.29 1.30 1.90 2.11 Air Flow (m3/h) - 1360 1600 1900 2200 2700 ESP (Pa) Standard (min max) 15 (15 80) 15 (15 100) Dimensions (mm) H W D 245 1475 576 245 1805 576 430 1563 655 Weight (kg) Net Weight 33 41 41 58 65 Piping (ømm) Liquid/Gas 9.52/15.88 Drainage Piping (mm) DN25 YES Mini VRF Series 27

Medium Static Ducted Indoor Unit Indoor Unit Model YDCM 050H0N(P)A YDCM 056H0N(P)A YDCM 063H0N(P)A YDCM 071H0N(P)A YDCM 080H0N(P)A YDCM 090H0N(P)A Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 5.0 5.6 6.3 7.1 8.0 9.0 Heating 5.6 6.3 7.1 8.0 9.0 10.0 Power Input (W) - 117 117 146 146 178 178 Current (A) Nominal 0.54 0.54 0.68 0.68 0.82 0.82 Air Flow (m3/h) - 900 960 1000 1200 1300 1500 ESP (Pa) Standard (min~max) 40(40-80) 40(40-80) 40(40-80) 40(40-80) 40(40-80) 40(40-80) Dimensions (mm) (H W D) 270x1100x700 270x1100x700 270x1100x700 270x1100x700 270x1100x700 270x1100x700 Weight (kg) Net Weight 43 43 43 43 44 44 Noise (db(a)) H/M/L 35/32/30 35/32/30 37/34/32 37/34/32 41/37/33 41/37/33 Piping (ømm) Liquid/Gas 6.35/12.70 6.35/12.70 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 Drainage Piping (mm) DN25 Indoor Unit Model YDCM 100H0N(P)A YDCM 112H0N(P)A YDCM 125H0N(P)A YDCM 140H0N(P)A YDCM 160H0N(P)A Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 10.0 11.2 12.5 14.0 14.0 Heating 11.2 12.5 14.0 16.0 16.0 Power Input (W) - 280 300 350 400 620 Current (A) Nominal 1.27 1.36 1.68 1.77 2.68 Air Flow (m3/h) - 1700 1900 2200 2400 2500 ESP (Pa) Standard (min~max) 40(40-90) 40(40-90) 40(40-90) 40(40-90) 40(40-90) Dimensions (mm) (H W D) 300 1450 700 300 1450 700 300 1450 700 300 1450 700 300 1450 700 Weight (kg) Net Weight 53 53 54 54 58 Noise (db(a)) H/M/L 41/37/34 41/37/34 43/40/36 43/40/36 48/46/43 Piping (ømm) Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 Drainage Piping (mm) DN25 28 YES Mini VRF Series

High Static Ducted Indoor Unit Indoor Unit Model YDCH 050H0N(P)A YDCH 056H0N(P)A YDCH 063H0N(P)A YDCH 071H0N(P)A YDCH 080H0N(P)A Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 5.0 5.6 6.3 7.1 8.0 Heating 5.6 6.3 7.1 8.0 9.0 Power Input (W) - 133 133 156 156 188 Current (A) Nominal 0.61 0.61 0.72 0.72 0.86 Air Flow (m3/h) - 900 960 1000 1200 1300 ESP (Pa) Standard (min~max) 80(80-120) 80(80-120) 80(80-120) 80(80-120) 80(80-120) Dimensions (mm) (H W D) 270x1100x700 270x1100x700 270x1100x700 270x1100x700 270x1100x700 Weight (kg) Net Weight 43 43 43 43 44 Noise (db(a)) H/M/L 37/34/32 37/34/32 39/36/34 39/36/34 43/40/36 Piping (ømm) Liquid/Gas 6.35/12.70 6.35/12.70 9.52/15.88 9.52/15.88 9.52/15.88 Drainage Piping (mm) DN25 Indoor Unit Model YDCH 090H0N(P)A YDCH 100H0N(P)A YDCH 112H0N(P)A YDCH 125H0N(P)A YDCH 140H0N(P)A Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 9.0 10.0 11.2 12.5 14.0 Heating 10.0 11.2 12.5 14.0 16.0 Power Input (W) - 188 400 420 550 570 Current (A) Nominal 0.86 1.82 1.91 2.50 2.59 Air Flow (m3/h) - 1700 1900 1800 2400 2600 ESP (Pa) Standard (min~max) 80(80-120) 90(90-175) 90(90-175) 90(90-175) 90(90-175) Dimensions (mm) (H W D) 270x1100x700 300 1450 700 300 1450 700 300 1450 700 300 1450 700 Weight (kg) Net Weight 57 57 58 58 52 Noise (db(a)) H/M/L 43/40/37 43/40/37 44/40/37 48/46/43 48/46/43 Piping (ømm) Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 9.52/15.88 Drainage Piping (mm) DN25 YES Mini VRF Series 29

2-way Cassette Indoor Indoor Unit Model YDDK028H0PA YDDK036H0PA YDDK045H0PA YDDK056H0PA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.8 3.6 4.5 5.6 Heating 3.2 4.0 5.0 6.3 Power Input (W) - 60 62 68 85 Current (A) Nominal 0.27 0.28 0.31 0.39 Air Flow (m3/h) - 500 600 770 900 Dimensions (mm) Weight (kg) Unit (H W D) 310 840 520 310 960 520 Panel (H W D) 30 1083 630 30 1203 630 Unit 41 41 47 47 Panel 6 6 7 7 Noise (db(a)) H/M/L 34/28/22 35/32/27 38/33/28 40/36/34 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 Drainage Piping (mm) DN25 Indoor Unit Model YDDK 071H0PA YDDK 090H0PA YDDK 112H0PA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 7.1 9.0 11.2 Heating 8.0 10.0 12.5 Power Input (W) - 94 129 175 Current (A) Nominal 0.43 0.59 0.80 Air Flow (m3/h) - 1160 1500 1700 Dimensions (mm) Weight (kg) Unit (H W D) 310 1200 520 310 1440 520 Panel (H W D) 30 1443 630 30 1683 630 Unit 53 65 65 Panel 8 9 9 Noise (db(a)) H/M/L 42/38/35 42/38/35 46/43/38 Piping (ømm) Liquid/Gas 9.52/15.88 9.52/15.88 9.52/15.88 Drainage Piping (mm) DN25 30 YES Mini VRF Series

Round-way Cassette Indoor Unit Model YDCK 028H0PA YDCK 036H0PA YDCK 040H0PA YDCK 045H0PA YDCK 050H0PA YDCK 056H0PA YDCK 063H0PA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.8 3.6 4.0 4.5 5.0 5.6 6.3 Heating 3.2 4.0 4.5 5.0 5.6 6.3 7.1 Power Input (W) - 17 19 19 19 26 27 42 Current (A) Nominal 0.13 0.15 0.15 0.15 0.22 0.28 0.37 Air Flow (m3/h) - 780 810 810 810 900 960 1100 Dimensions (mm) Weight (kg) Unit (H W D) 246 840 840 Panel (H W D) 50 950 950 Unit 23 26 Panel 5.5 Noise (db(a)) H/M/L 28/27/25 29/28/26 31/29/27 32/31/28 32/31/28 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 6.35/12.7 9.52/15.88 Drainage Piping (mm) DN25 Indoor Unit Model YDCK 071H0PA YDCK 080H0PA YDCK 090H0PA YDCK 100H0PA YDCK 112H0PA YDCK 125H0PA YDCK 140H0PA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 7.1 8.0 9.0 10.0 11.2 12.5 14.0 Heating 8.0 9.0 10.0 11.2 12.5 14.0 16.0 Power Input (W) - 42 63 63 129 129 142 171 Current (A) Nominal 0.37 0.54 0.54 1.07 1.07 1.17 1.39 Air Flow (m3/h) - 1100 1500 1500 1900 1900 2010 2010 Dimensions (mm) Weight (kg) Unit (H W D) 246 840 840 288 840 840 Panel (H W D) 50 950 950 Unit 26 29 29 29 29 29 32 Panel 5.5 Noise (db(a)) H/M/L 35/31/28 38/35/32 45/39/36 47/43/38 48/45/42 Piping (ømm) Liquid/Gas 9.52/15.88 Drainage Piping (mm) DN25 YES Mini VRF Series 31

High Wall Indoor Indoor Unit Model YDHW 022H0NA YDHW 028H0NA YDHW 036H0NA YDHW 056H0NA YDHW 071H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.2 2.8 3.6 5.6 7.1 Heating 2.80 3.20 4.00 6.30 7.15 Power Input (W) - 35 35 40 50 70 Current (A) Nominal 0.18 0.18 0.23 0.25 0.35 Air Flow (m3/h) - 450 450 570 730 1050 Dimensions (mm) H W D 295 890 215 295 890 215 295 890 215 302 1070 220 302 1070 220 Weight (kg) Net Weight 14 14 14 16 16 Noise (db(a)) H/M/L 34/30/26 34/30/26 38/35/31 44/41/39 44/41/39 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/9.52 6.35/12.7 6.35/12.7 9.52/15.88 Drainage Piping (mm) DN20 32 YES Mini VRF Series

Floor/Ceiling Indoor Indoor Unit Model YDEC028H0NA YDEC036H0NA YDEC045H0NA YDEC056H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.8 3.6 4.5 5.6 Heating 3.2 4.0 5.0 6.3 Power Input (W) - 110 110 130 130 Current (A) Nominal 0.55 0.55 0.65 0.65 Air Flow (m3/h) - 600 600 950 950 Dimensions (mm) H W D 680 x 1245 x 240 Weight (kg) Net Weight 36 Noise (db(a)) H/M/L 37/33/30 37/33/30 46/44/41 46/44/42 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 6.35/12.7 Drainage Piping (mm) DN25 Indoor Unit Model YDEC071H0NA YDEC080H0NA YDEC090H0NA YDEC112H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 7.1 8.0 9.0 11.2 Heating 8.0 9.0 10.0 12.5 Power Input (W) - 180 210 210 210 Current (A) Nominal 0.83 0.97 0.97 1.20 Air Flow (m3/h) - 1250 1550 1550 1950 Dimensions (mm) H W D 680 x 1245 x 240 680 x1670 x 240 Weight (kg) Net Weight 36 38 51 Noise (db(a)) H/M/L 47/45/42 52/48/46 52/48/46 52/48/46 Piping (ømm) Liquid/Gas 9.52/15.88 Drainage Piping (mm) DN25 YES Mini VRF Series 33

Floor-concealed Indoor Indoor Unit Model YDVC 028H0NA YDVC 045H0NA YDVC 056H0NA YDVC 071H0NA Power Supply (V/Ph/Hz) 220/1/50 220/1/50 220/1/50 220/1/50 Capacity (kw) Cooling 2.8 4.5 5.6 7.1 Heating 3.2 5.0 6.3 8.0 Power Input (W) - 41 50 60 71 Current (A) Nominal 0.18 0.23 0.27 0.32 Air Flow (m3/h) - 420 680 900 1000 Dimensions (mm) H W D 600 x 730 x 230 600 x 980 x 230 600 x 1334 x 230 600 x 1334 x 230 Weight (kg) Net Weight 20 24 30 31 Noise (db(a)) Standard 35/32/30 35/32/30 36/33/31 37/34/32 Piping (ømm) Liquid/Gas 6.35/9.52 6.35/12.7 6.35/12.7 9.52/15.88 Drainage Piping (mm) DN25 Note: 1. Cooling conditions: indoor 27 CDB/ 19 CWB, outdoor 35 CDB, equivalent length 10m, IU/OU height difference 0m. 2. Heating conditions: indoor 20 CDB, outdoor 7 CDB/6 CWB, equivalent length 10m, IU/OU height difference 0m. 3. Noise data is tested in semi-anechoic chamber and converted to equivalent anechoic chamber data. The actual noise data could vary per different installation and working conditions. Standard Offering & Option List YDCD YDCP YDCC YDCM YDCH YDCK YDHW YDEC YDDK YDVC Water Pump -H0PA: -H0NA: -H0PA: -H0NA: -H0PA: -H0NA: -H0PA: -H0NA: Non-indicative Panel Indicative Panel Filter : Standard : Option : N/A 34 YES Mini VRF Series

Controls Outdoor Units YVOH30-60 Modbus Communication Board BACnet Communication Board YORK-DVR-002 YORK-TRS-003A Indoor Units YDCD YDCP YDCC YDCM YDCH YDCK YDHW YDEC YDDK YDVC Wired Controller WVH-02 2.8kW Simplified Wired Controller WVH-21-E Wireless Controller RVH-01 Hotel Card / Receiver / Top A Coo He On/Off Controller Modbus /BACnet KVH-02 Central Controller Modbus /BACnet CVH-01-02 : Standard : Option : N/A Item Model Description Wired Controller WVH-02 Control 1 or up to 4 indoor units (setting temperature, air flow, mode, timer, swing, sleeping mode, heater, etc.) Set master/auxiliary control in one system Receive wireless controller signal 680mm Modify indoor unit parameter, record and query error message 240mm Distribute and set address Switch between C and F 1245~1670mm Simplified Wired Controller Ceiling WVH-21-E (Unit: mm) Control 1 or up to 4 indoor units (setting temperature, air flow, mode, swing, sleeping mode, heater, etc.) Modify indoor unit parameter, record and query error message O n Wireless Controller RVH-01 Control indoor units (setting temperature, air flow, mode, timer, swing and other expansion functions) Send signal to remote receiver or wired controller On/Off Controller KVH-02 Connect up to 4 sets of YVOH outdoor systems (each outdoor system supporting up to 64 indoor units) Indoor unit can be selected as a group randomly (each group supporting up to 16 indoor units) Can set outdoor unit operation mode and switch indoor unit on or off directly Central Controller CVH-01-02 Connect up to 16 sets of YVOH outdoor systems (each outdoor system supporting up to 64 indoor units) 128 zones & 512 groups can be settled (each group supporting up to 16 indoor units, while zone doesn t have such requirement) Can do operations, such as turn on/off, set temperature, check operation status, etc. YES Mini VRF Series 35

Notes

Notes

2014 Johnson Controls, Inc. www.johnsoncontrols.com PUBL-7347