Large Family Daycare Guideline

Similar documents
Residential-based Care Facility R-4 Guideline

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

For additional information regarding R-3.1 residential care facilities please contact (951)

Residential Based Care Facility Guidelines

Residential-based Care Facility R2.1 Guideline

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Residential Care Facilities Requirements

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Residential Large Family Daycare Facilities

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

FIRE PREVENTION STANDARDS

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

Residential Alcohol & Drug Rehabilitation Facilities

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

APPLICATION FOR Large Family Day Care Permit

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Photovoltaic (Solar) Array Installation Guide

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

For additional information regarding Group I occupancies please call (951)

THE TOWNSHIP OF CRANBURY

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Residential Care Facilities

Certificate of Inspection CHECKLIST

Rental Housing Inspection Guide

Township of Maplewood

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

Smoke Alarms and Carbon Monoxide Alarms

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Defend In Place 2012 IFC Overview of Institutional Occupancies

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

GUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU TENANT IMPROVEMENT GROUP A FIRE PLAN REVIEW CHECKLIST

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

Agency for Health Care Administration

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Requirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

HIGH-RISE RETROFIT ORDINANCES - NO and NO

Temporary Haunted Houses

Requirements for Smoke Detector / Carbon Monoxide/ Fire Extinguisher Certification

Flemington Borough Fire Safety 38 Park Ave Flemington, NJ 08822

Florida Building Code 2010

CHAPTER 7 ALTERATIONS LEVEL

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Denver Fire Department Fire Prevention Division

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

C I T Y O F B A N N I N G BANNING FIRE SERVICES 3900 W. WILSON STREET (951) PHONE (951) FAX

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

BUTTE COUNTY PERMIT NO: DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION* APN: Property Address. Policy Number. Carrier.

Agency for Health Care Administration

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

Family Foster Home Fire Safety Evaluation Checklist Instructions

Carbon Monoxide Detectors in New and Existing Buildings

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

Conversion to Vacation Home Permit Life Safety Survey

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

Chapter Nursing Homes

Building and Safety Division Civic Center Dr, Bellflower, CA, (562) x

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

REQUIREMENTS & GUIDELINES

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act

CITY OF HEALDSBURG SENIOR CENTER IMPROVEMENT PROJECT

OCFEC Fire Marshal Summary Report

BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE

Short Term Accommodations Fire Code Requirements

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

[NOTE: Proposed additions to existing code language are highlighted in yellow.]

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Johnson County, Kansas. Home Daycare Handbook 2013 Edition

SAF-BCF SECOND REVISIONS WITH STATEMENTS

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS 780 CMR: MASSACHUSETTS AMENDMENTS TO AND THE INTERNATIONAL BUILDING CODE 2009

Bold items are particular to the City of Euless

Apartment Fire & Safety Inspection. City of Guadalupe

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

California Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19

2012 NC Building Code Chapter 2, 602.4, , , Chapter 35 Cross-Laminated Timber. ( Item B-1)

SECTION 915 CARBON MONOXIDE DETECTION

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

FIRE PLAN CHECK CORRECTION List for Commercial Occupancies

FIRE APPARATUS ACCESS AND WATER SUPPLY GUIDELINE

Fire Alarm, Water Flow Alarm & Signaling Systems

Short-Term & Accessory Short-Term Rental Safety Certification

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Transcription:

Moreno Valley Fire Department Fire Prevention Bureau Large Family Daycare Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: April 10, 2017

Large Family Daycare Guideline Purpose This information bulletin has been developed to assist applicants, architects, and contractors in determining the minimum requirements for a large family day care. Scope This bulletin is intended to ensure compliance with the appropriate requirements for a large family day care which are found in the California Code of Regulations CCR, Title 19, as well as the 2016 California Fire Code (CFC) and 2016 California Building Code (CBC). Plans not conforming to the requirements listed herein will be returned as incomplete. Occupancy Classifications Every large-family day care home shall comply with the provisions for Group R-3 occupancies. CBC 455. Submittal Requirements Site and floor plans shall be submitted to the Moreno Valley Fire Prevention Bureau for review, along with the Form 850 from Community Care Licensing, at the time of final fire inspection request. The plans must include the building address, occupancy classification of large family day care, and the location of smoke detectors, fire alarms, exit doors and gates. Provide a detailed letter identifying all intended use and operations of the facility. Include room locations for children. Provide a current copy of the city or county home occupancy business license/permit at the time of requesting a fire safety inspection. Use this guideline to ensure that your plans have at least the minimum amount of information required for a review. It may be necessary to provide additional information beyond what is requested in this guideline depending on the project. Codes and Standards 1) Addressing: a) Address numbers shall be posted on the building and shall be visible from the street. Said numbers shall contrast with their background. CFC 505.1 2) Electrical: a) Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the code official responsible for enforcement of the California Electrical Code. Electrical 2

wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. CFC 605.1 3) Fire Alarms: a) Every large family day-care home shall be provided with at least one manual fire alarm box at a location approved by the enforcing agency. Such device shall actuate a fire alarm signal, which shall be audible throughout the facility at a minimum level of 15 db above ambient noise level. These devices need not be interconnected to any other fire alarm device, have a control panel or be electrically supervised or provided with emergency power. Such device or devices shall be attached to the structure and must be a device that is listed and approved by the Office of the State Fire Marshal. CFC 907.2.6.4 4) Smoke Alarms: a) Large-family day care homes shall be equipped with State Fire Marshal approved and listed single-station residential-type smoke alarms. CBC 455.3 b) Where more than one smoke alarm is required, the smoke alarms shall be interconnected in such a manner that the activation of one alarm will activate all of the alarms. CFC 907.2.11.5 c) Locations: CFC 907.2.11.2 1. On ceilings or walls outside of each separate sleeping area in the immediate vicinity of bedrooms. 2. In each room used for sleeping purposes. 3. In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. 5) Carbon Monoxide Alarms a) CFC 907.2.11 requires Group R occupancies located in a building containing a fuel-burning appliance or a building that has an attached garage shall be equipped with single station carbon monoxide alarms. The carbon monoxide alarms shall be listed as complying with UL 2034 and shall be installed and maintained in accordance with NFPA 720 and the manufacturer's instructions. Exception: Sleeping units or dwelling units that do not themselves contain a fuel-burning appliance or have an attached garage, but that are located in a building with a fuel-burning appliance or an attached garage, need not be provided with single station carbon monoxide alarms provided that: 3

1. The sleeping unit or dwelling unit is located more than one story above or below any story that contains a fuel-burning appliance or an attached garage; and 2. The sleeping unit or dwelling unit is not connected by duct work or ventilation shafts to any room containing a fuel-burning appliance or to an attached garage; and 3. The building is equipped with a common area carbon monoxide detection system that includes all enclosed common area spaces. 6) Fire Extinguisher: a) Large-family day care homes shall be equipped with a portable fire extinguisher having a minimum 2-A 10-BC rating. CBC 455.4 b) Portable fire extinguishers having a gross weight not exceeding 40-pounds shall be installed so that its top is not more than 5-feet above the floor. CFC 906.9.1 c) Fire extinguishers shall be serviced on an annual basis. CCR, Title 19, Sec 575.1 7) Room Locations: a) Rooms used for day care purposes shall not be located above the first story. CBC 1006.2.2.7 Exception: Buildings equipped with an automatic sprinkler system throughout and which have at least one of the required exits providing access directly to the exterior. NFPA 13R may be used in large-family day care homes. The sprinkler omissions of NFPA 13R shall not apply unless approved by the authority having jurisdiction. b) The garage of a home is not part of the Dwelling Unit, therefore, shall not be used for day care purposes. CBC Definitions and occupancy use/classification. 8) Garage Separation: a) Door openings between a private garage and the dwelling unit shall be equipped with either solid wood doors or solid or honeycomb core steel doors not less than 1 3/8 inches in thickness or doors in compliance with CBC 716.5.3 with a fire protection rating of not less than 20 minutes. The integrity of the wall between the dwelling and the garage shall be maintained and be free of penetrations. Doors shall be self-closing and self-latching. CBC 406.3.4 9) Exiting: a) Every story or basement of a large-family day care home shall be provided with two exits which are remotely located from each other. Every required exit shall be of a size to permit the installation of a door not less than 32-inches in 4

clear width and not less than 6-feet, 8-inches in height. A manually operated horizontal sliding door may be used as one of the two required exits. Where basements are used for day-care purposes, one of the two required exits shall provide access directly to the exterior without entering the first story. The second exit from the basement may either pass through the story above or exit directly to the exterior. CBC 1006.2.2.7 Exception: Buildings equipped with an automatic sprinkler system throughout and which have at least one of the required exits providing access directly to the exterior. NFPA 13R may be used in large family day-care homes. The sprinkler omissions of NFPA 13R shall not apply unless approved by the enforcing agency. Egress doors, including manually operated horizontal sliding doors, shall be readily openable from the inside without use of a key or special knowledge or effort. CBC 1010.1.9 10) Special Hazards: a) Every unenclosed gas-fired water heater or furnace which is within the area used for child care in a large-family day care home shall be protected in such a way as to prevent children from making contact with those appliances. CBC 455.7 Exception: This does not apply to kitchen stoves or ovens. 11) Ignition Sources: a) Clearance between ignition sources, such as luminaries, heaters, flameproducing devices and combustible materials shall be maintained in an approved manner. CFC 305.1 5